User Manual
Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 1 / 13 Written by Checked by Approved by Dongle PL Test Manual 결 작 성 검 토 승 인 재 2016. 11. 21. KN-연-062 (13.10.18)-0 Company Confidential Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 2 / 13 Written by Checked by Approved by Document Revision History No Description -. initial KN-연-062 (13.10.18)-0 Author BJ KIM Page REV. NO 1.0 Revised Date 2016.11.20 Company Confidential Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 3 / 13 Written by Checked by Approved by INDEX DOCUMENT REVISION HISTORY ........................................................................................................................ 2 1. DONGLE-PL TEST USING THE POWER SUPPLY .................................................................................... 4 2. IQ NXN SETTING.................................................................................................................................................. 5 3. TX TEST ................................................................................................................................................................. 6 4. RX TEST ................................................................................................................................................................ 10 KN-연-062 (13.10.18)-0 Company Confidential Document NO. Project Code Project Name Subject 1. KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 4 / 13 Written by Checked by Approved by Dongle-PL Test using the Power Supply 1-1. Dongle-PL Test using the Power Supply Dongle PL Board is powered by a Power Supply. current consumption check using the Power Supply Power Supply settings DC15V, 1A Dongle-PLs average power consumption is under 0.3W. Current consumption 15~25mA @ 15V 1-2. Change into ISP mode. 1-3. Connect Debug Cable to Z_Deg port(J2). (Use Pogo Pin) 1-4. Execute Device-Programmer MD 2.60 Program. < Device-Programmer MD 2.60 Execution screen 1-5. Select the MG2450/2455. < Device-Programmer's Device Setting> KN-연-062 (13.10.18)-0 Company Confidential Document NO. Project Code Project Name Subject 1-6. KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 5 / 13 Written by Checked by Approved by Open the RF Test Program to download to Dongle PL. MG245X-KMW_IQVIEWER_V22_PA_Rev02.H00 MG245X-KMW_IQVIEWER_V22_PA_Rev02.H01 1-7. Download only choose H00 file extension. Download to LCS Node. < Download complete message > 1-8. Change into Operating Mode 2. IQ NxN Test Setting 2-1. Connect Ethernet cable to Ethernet socket at IQ NXN device rear. Then Check communication to PC to IQ NXN. < IQ NXN rear> 2-2. Setting PC's IP as under figure. KN-연-062 (13.10.18)-0 Company Confidential KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Document NO. Project Code Project Name Subject Revision NO. P1.0 Revised Date 2016.11.21 Page 6 / 13 Written by Checked by Approved by < PC’s IP > 2-3. Execute IQsignal for Zigbee. And Setting Parameter as under figure. < IQsignal for Zigbee Program Parameter Setting > 2-4. 3. Connect USB to Serial Cable to Z_Deg port(J2). TX Test 3-1. Connect IQ NXN's RF1 channel to RF output(MCX) using the RF Cable.Execute Tera Term Setting serial port as under figure. : The Top bar ‘Setup’ -> ‘Serial Port ...’ selection KN-연-062 (13.10.18)-0 Company Confidential Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 7 / 13 Written by Checked by Approved by < Tera Term’s Serial Port setting > Press 'H' key on the keyboard to display the test menu as below.. < KMW TEST MENU > Press 'C' key on the keyboard and select channel. < For example selected 11 channel.> if press 'M' on the keyboard, Tx will be sent Modulation with IFS. KN-연-062 (13.10.18)-0 Company Confidential Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 8 / 13 Written by Checked by Approved by 3-2. Implement Tx test using the IQsignal for Zigbee Program. - Measure Antenna: HW-2450D-MSMA2 HANWOOL TECH ( SEGA Antenna ) -Trigger type : signal trigger -.Triger level : -25dBm - External Atten : 10dBm < Dongle-PL Position (Use SEGA Antenna) > KN-연-062 (13.10.18)-0 Company Confidential Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Page Revised Date 2016.11.21 9 / 13 Written by Checked by Approved by < Tx test measure > Compare with the following items to check for defects Req'd Spec Remark Transmit Power ≥3dBm [6.9.5]IEEE802.15.4-2006 Spectrum PSD mask 확인 Transmit Center Frequency Tolerance ±40ppm [6.9.4]IEEE802.15.4-2006 Error Vector Magnitude ≤35% [6.9.3]IEEE802.15.4-2006 [6.5.3.1]IEEE802.15.4-2006 < Zigbee Rx Test ChecK List> KN-연-062 (13.10.18)-0 Company Confidential Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 10 / 13 Written by Checked by Approved by RX Test 4-1. Execute 'vector signal analyzer' as under figure. 4-2. Connect IQnxn's RF2 Channel to device's output. 4-3. Open the 'zigbee_psdu20.mod' file. 4-4. Execute ‘Tera Term’ And then Setting port. ( 3-2. Reference setting Teraterm) 4-5. Select RF ON/OFF button as under figure, select 'Start' button. then number 1000's Tx data is transmitted to the Dongle PL Board. KN-연-062 (13.10.18)-0 Company Confidential Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 11 / 13 Written by Checked by Approved by 4-6. If press '2' on the keyboard, can be check transmitted result. < Tera Term Rx count Output Screen > Compare with the following items to check for defects Req'd Spec Receiver Sensitivity ≥-75dBm Remark [6.5.3.3]IEEE802.15.4-2006 (≥85dBm) Packet Error Rate(1000) ≤1% Receiver maximum input level -20dBm [6.5.3.3]IEEE802.15.4-2006 [6.9.6]IEEE802.15.4-2006 Specified as ≥-85dBm on IEEE802.15.4-2006, Changed to ≥-75dBm considering that the test environment is wireless. KN-연-062 (13.10.18)-0 Company Confidential Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 12 / 13 Written by Checked by Approved by FCC compliance Information FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution Modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Compliance Information : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Including interference that may cause undesired operation. Modifications not expressly approved by the manufacturer could void the user’s authority To operated the equipment under FCC rules. To satisfy FCC exterior labeling requirements, the following text must be placed on the exterior of the end product. Contains Transmitter Module FCC ID : ORI-DONGLE-PL CAUTION : This device and its antenna(s) must not be co-located or operated in conjunction with any other antenna or transmitter. End users cannot modify this transmitter device. Any unauthorized modification could void the user’s authority to operate this device. This module is limited to installation in fixed applications, and only installed Lighting Fixture. This module can not be attached to other device without Lighting device. IMPORTANT NOTE: FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. KN-연-062 (13.10.18)-0 Company Confidential Document NO. Project Code Project Name Subject KMWI-A61-E199 KMWI-A61-E202 L15LT028Z Dongle PL Dongle PL Manual Revision NO. P1.0 Revised Date 2016.11.21 Page 13 / 13 Written by Checked by Approved by This device is intended only for OEM integrators under the following conditions: 1)The transmitter module may not be co-located with any other transmitter or antenna, 2)OEM shall not supply any tool or info to the end-user regarding to Regulatory Domain change. As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.). IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual. KN-연-062 (13.10.18)-0 Company Confidential
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Author : kmwm71 Create Date : 2016:12:16 13:44:00+09:00 Modify Date : 2016:12:16 13:52:08+09:00 Language : ko-KR XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Microsoft® Office Word 2007 Format : application/pdf Creator : kmwm71 Creator Tool : Microsoft® Office Word 2007 Metadata Date : 2016:12:16 13:52:08+09:00 Document ID : uuid:3C42D99E-4A0D-4438-A3CF-61F4EA1C9D9A Instance ID : uuid:2fbc455f-23b5-492d-b143-b196954517e2 Part : 1 Conformance : B Page Count : 13EXIF Metadata provided by EXIF.tools