KMW H-FEM-L-A DAS Head-End User Manual PDO

KMW U.S.A., INC. DAS Head-End PDO

Contents

POD User Manual_v0.9_Revised_Part1

     USER MANUAL FOR POD SYSTEM (Version 0.9)                       Document No.: MUN0630-2015 Date: November 31, 2016
           User Manual for POD Systems                                                     Revision: 0.9    2  Revision History   Change List Version Change list Contents                    Version Author Descriptions Date 0.1 KMW Initial Release 5/14/2015 0.2 KMW Update FCC Regulation Statement 12/23/2015 0.3 KMW Update RF specification on 2.2 and 5 1/12/2016 0.4 KMW Update FCC RF Exposure information 1/15/2016 0.5 KMW Make typo correct 1/18/2016 0.6 KMW Change the RF Radiation Exposure 2/4/2016 0.7 KMW Update RF Exposure statement and HAAT information 2/24/2016 0.8 KMW Update AWS band 10/31/2016 0.9 KMW Update  SAFETY AND REGUALTION WARNING NOTICE 11/1/2016
           User Manual for POD Systems                                                     Revision: 0.9    3  List for Acronyms  AGC  Automatic Gain Control ALC  Automatic Level Control BDA  Bi-Directional Amplifier BOM  Bill of Material BTS  Base Transceiver Station DAS  Distributed Antenna System DL  Downlink Downlink  Path covered from the Base Transceiver Station (BTS) to the subscribers’ service area via the repeater HEU  Head-end Unit IF  Intermediate Frequency LNA   Low Noise Amplifier LTE  Long Term Evolution MS  Mobile Station NMS  Network Management System PA  Power Amplifier PSU  Power Supply Unit RF  Radio Frequency RU  Remote Unit UL  Uplink Uplink  Path covered from the subscribers’ service area to the Base Transceiver Station (BTS) via the repeater  Uptime  Time during which a Unit or Module is in operation VSWR  Voltage Standing Wave Ratio
           User Manual for POD Systems                                                     Revision: 0.9    4  Table of Contents 1. POD System Overview ...................................................................................................................................... 14 1.1 Features of POD System ............................................................................................................................ 14 1.2 POD System Architecture .......................................................................................................................... 15 1.3 POD System Configuration ........................................................................................................................ 17 1.3.1 SISO Configuration .............................................................................................................................. 17 1.3.2 MIMO Configuration .......................................................................................................................... 18 1.4 POD System Scalability & Limitation .......................................................................................................... 19 2. POD system Components ................................................................................................................................. 21 2.1 Head-end Unit............................................................................................................................................ 21 2.1.1 POD-H-DMCU (DAS Main Control Unit) .............................................................................................. 23 2.1.1.1 Functions and features ............................................................................................................. 23 2.1.1.2 Specifications ............................................................................................................................ 23 2.1.1.3 LED, LCD & Key PAD, Reset ....................................................................................................... 23 2.1.1.4 Ethernet Ports ........................................................................................................................... 24 2.1.1.5 DC power input port & power switch ....................................................................................... 24 2.1.1.6 External Alarm Port .................................................................................................................. 24 2.1.1.7 Ground port .............................................................................................................................. 25 2.1.1.8 Alarms ....................................................................................................................................... 25 2.1.2 POD-H-SRU ......................................................................................................................................... 26 2.1.2.1 Functions and features ............................................................................................................. 26 2.1.2.2 Specifications ............................................................................................................................ 26 2.1.2.3 DC input port & Fuse ................................................................................................................ 26 2.1.2.4 FAN port .................................................................................................................................... 27 2.1.2.5 Ground port .............................................................................................................................. 27 2.1.3 POD-H-SCM ........................................................................................................................................ 28 2.1.3.1 Functions and features ............................................................................................................. 28 2.1.3.2 Specifications ............................................................................................................................ 28 2.1.3.3 LED, LCD & Key PAD, Reset ....................................................................................................... 28 2.1.3.4 Ethernet Port ............................................................................................................................ 29 2.1.3.5 Communication port ................................................................................................................. 29 2.1.3.6 Alarms ....................................................................................................................................... 29 2.1.4 POD-H-MCM ....................................................................................................................................... 30 2.1.4.1 Functions and features ............................................................................................................. 30 2.1.4.2 Specifications ............................................................................................................................ 30 2.1.4.3 LED, LCD & Key PAD, Reset ....................................................................................................... 30 2.1.4.4 Ethernet Ports ........................................................................................................................... 31
           User Manual for POD Systems                                                     Revision: 0.9    5  2.1.4.5 External Alarm Ports ................................................................................................................. 32 2.1.4.6 Communication port ................................................................................................................. 32 2.1.4.7 Alarms ....................................................................................................................................... 32 2.1.5 POD-H-FEM-L-x ................................................................................................................................... 33 2.1.5.1 Functions and features ............................................................................................................. 34 2.1.5.2 Specifications ............................................................................................................................ 34 2.1.5.3 RF Port and LED ........................................................................................................................ 35 2.1.5.4 Communication port ................................................................................................................. 36 2.1.5.5 Alarms ....................................................................................................................................... 36 2.1.6 POD-H-FEM-H-x .................................................................................................................................. 37 2.1.6.1 Functions and features ............................................................................................................. 38 2.1.6.2 Specifications ............................................................................................................................ 38 2.1.6.3 RF port and LED ........................................................................................................................ 39 2.1.6.4 Communication port ................................................................................................................. 40 2.1.6.5 Alarms ....................................................................................................................................... 40 2.1.7 POD-H-COM-8 .................................................................................................................................... 41 2.1.7.1 Functions and features ............................................................................................................. 41 2.1.7.2 Specifications ............................................................................................................................ 41 2.1.7.3 RF port and LED ........................................................................................................................ 41 2.1.7.4 Communication port ................................................................................................................. 42 2.1.7.5 Alarms ....................................................................................................................................... 42 2.1.8 POD-H-DTM-8x8 ................................................................................................................................. 43 2.1.8.1 Functions and features ............................................................................................................. 43 2.1.8.2 Specifications ............................................................................................................................ 43 2.1.8.3 RF port and LED ........................................................................................................................ 43 2.1.8.4 Communication port ................................................................................................................. 44 2.1.8.5 Alarms ....................................................................................................................................... 44 2.1.9 POD-H-HOM-L .................................................................................................................................... 45 2.1.9.1 Functions and features ............................................................................................................. 45 2.1.9.2 Specifications ............................................................................................................................ 45 2.1.9.3 RF port and LED ........................................................................................................................ 45 2.1.9.4 Optic port .................................................................................................................................. 46 2.1.9.5 Communication port ................................................................................................................. 46 2.1.9.6 Alarms ....................................................................................................................................... 46 2.1.10 POD-H-HOM-H .................................................................................................................................... 48 2.1.10.1 Functions and features ............................................................................................................ 48 2.1.10.2 Specifications .......................................................................................................................... 48
           User Manual for POD Systems                                                     Revision: 0.9    6  2.1.10.3 RF port and LED ....................................................................................................................... 48 2.1.10.4 Optic port ................................................................................................................................ 49 2.1.10.5 Communication port ............................................................................................................... 49 2.1.10.6 Alarms ..................................................................................................................................... 49 2.1.11 POD-H-STM-8x4 .................................................................................................................................. 51 2.1.11.1 Functions and features ............................................................................................................ 51 2.1.11.2 Specifications .......................................................................................................................... 51 2.1.11.3 RF port and LED ....................................................................................................................... 52 2.1.11.4 Communication port ............................................................................................................... 53 2.1.11.5 Alarms ..................................................................................................................................... 53 2.1.12 POD-H-PSU-x ...................................................................................................................................... 54 2.1.12.1 Functions and features ............................................................................................................ 54 2.1.12.2 Specifications .......................................................................................................................... 54 2.1.12.3 LED .......................................................................................................................................... 54 2.1.12.4 Ethernet Port ........................................................................................................................... 54 2.1.12.5 AC input on/off Switch & DC output on/off switch ................................................................. 54 2.1.12.6 AC input port & DC output port .............................................................................................. 55 2.1.12.7 Rack ID ..................................................................................................................................... 55 2.1.12.8 Ground port ............................................................................................................................ 56 2.1.12.9 Alarms ..................................................................................................................................... 56 2.1.13 POD-H-CDU ......................................................................................................................................... 57 2.1.13.1 Functions and features ............................................................................................................ 57 2.1.14 POD-H-FAU ......................................................................................................................................... 57 2.1.14.1 Functions and features ............................................................................................................ 57 2.1.14.2 The rules for installing FAN unit .............................................................................................. 57 2.1.14.3 Port .......................................................................................................................................... 57 2.1.14.4 Alarms ..................................................................................................................................... 58 2.2 Remote Unit ............................................................................................................................................... 59 2.2.1 7/5/3 band RU for commercial band service (POD-R-7S8CPAWB-2730-AC/DC)................................ 59 2.2.1.1 Functions and features ............................................................................................................. 59 2.2.1.2 Specifications ............................................................................................................................ 59 2.2.1.3 RF ports and LED ....................................................................................................................... 62 2.2.1.4 Debug Window ......................................................................................................................... 63 2.2.1.5 Alarms ....................................................................................................................................... 65 2.2.1.6 Grounding ................................................................................................................................. 65 2.2.2 PS700/800 RU for public safety 700/800 frequency band service (POD-R-P78-27-AC/DC) ............... 66 2.2.2.1 Functions and features ............................................................................................................. 66
           User Manual for POD Systems                                                     Revision: 0.9    7  2.2.2.2 Specifications ............................................................................................................................ 66 2.2.2.3 RF ports and LED ....................................................................................................................... 67 2.2.2.4 Debug Window ......................................................................................................................... 68 2.2.2.5 Battery Backup Port .................................................................................................................. 69 2.2.2.6 Alarms ....................................................................................................................................... 70 2.2.2.7 Grounding ................................................................................................................................. 71 3. Equipment Installation ...................................................................................................................................... 72 3.1 Inspection before equipment installation ................................................................................................. 72 3.1.1 The Part list for each unit ................................................................................................................... 72 3.1.1.1 Head-end Unit .......................................................................................................................... 72 3.1.1.2 Remote Unit .............................................................................................................................. 73 3.2 Head-end Unit Equipment Installation ...................................................................................................... 74 3.2.1 Installation Head-end Unit in a 19” rack ............................................................................................ 74 3.2.1.1 The sequence for mounting head-end unit .............................................................................. 75 3.2.2 Grounding ........................................................................................................................................... 76 3.2.3 Optic port Cleaning ............................................................................................................................. 76 3.3 Remote Unit ............................................................................................................................................... 77 3.3.1 Wall Mount for 3/5/7 band RU and PS700/800 RU............................................................................ 77 3.3.2 Grounding ........................................................................................................................................... 78 3.3.2.1 3/5/7 band RU, PS700/800 RU ................................................................................................. 78 4. Cable Connection .............................................................................................................................................. 79 4.1 Head-end Unit Cable Connection .............................................................................................................. 79 4.1.1 Cable ................................................................................................................................................... 79 4.1.2 Cable Connection Example for frequency bands with FDD type ........................................................ 80 4.1.3 Cable Connection for TDD 2.6G frequency band................................................................................ 82 4.1.4 Cable Connection Example for Public Safety 700/800 band .............................................................. 84 4.1.5 Cable Connection Example for MIMO configuration ......................................................................... 85 4.1.6 Cable connection between multiple Racks ........................................................................................ 87 4.2 Remote Unit Cable Connection ................................................................................................................. 88 4.2.1 7/5/3 band & PS700/800 RU .............................................................................................................. 88 4.2.1.1 Cable ......................................................................................................................................... 88 4.2.1.2 Optic cable connection ............................................................................................................. 89 4.2.1.3 AC or DC power cable connection ............................................................................................ 90 4.2.1.4 Ethernet cable connection for connecting with Expansion RU ................................................ 91 5. Specification ...................................................................................................................................................... 92 5.1 Electrical Specifications (Low power HFM – Low power RU) .................................................................... 92 5.2 Additional Model Names ........................................................................................................................... 94
           User Manual for POD Systems                                                     Revision: 0.9    8   Figures Figure 1-1 DAS Overall Block Diagram ................................................................................................................. 15 Figure 1-2 How it works ....................................................................................................................................... 16 Figure 1-3 SISO Configuration .............................................................................................................................. 17 Figure 1-4 MIMO Configuration ........................................................................................................................... 18 Figure 1-5 POD System Scalability ....................................................................................................................... 19 Figure 2-1 Head-end Unit Front View .................................................................................................................. 21 Figure 2-2 Head-end Unit Rear View ................................................................................................................... 21 Figure 2-3 POD-H-DMCU ..................................................................................................................................... 23 Figure 2-4 LED, LCD & Key PAD, Reset ................................................................................................................. 23 Figure 2-5 Ethernet Ports ..................................................................................................................................... 24 Figure 2-6 DC power input port & power switch ................................................................................................. 24 Figure 2-7 External Alarm Ports ........................................................................................................................... 25 Figure 2-8 POD-H-SRU Front View ....................................................................................................................... 26 Figure 2-9 POD-H-SRU Rear View ........................................................................................................................ 26 Figure 2-10 DC input port & Fuse .......................................................................................................................... 27 Figure 2-11 FAN port ............................................................................................................................................. 27 Figure 2-12 POD-H-SCM ......................................................................................................................................... 28 Figure 2-13 LED, LCD & Key PAD ............................................................................................................................ 28 Figure 2-14 Ethernet Port ...................................................................................................................................... 29 Figure 2-15 Communication Port ........................................................................................................................... 29 Figure 2-16 POD-H-MCM ....................................................................................................................................... 30 Figure 2-17 LED, LCD & Key PAD, Reset ................................................................................................................. 31 Figure 2-18 Ethernet ports..................................................................................................................................... 31 Figure 2-19 External Alarm Ports ........................................................................................................................... 32 Figure 2-20 Communication Port ........................................................................................................................... 32 Figure 2-21 POD-H-FEM-L-x Front & Rear View ..................................................................................................... 33 Figure 2-22 POD-H-FEM-L-x RF port and LED ........................................................................................................ 35 Figure 2-23 Communication Port ........................................................................................................................... 36 Figure 2-24 POD-H-FEM-H-x Front & Rear View .................................................................................................... 37 Figure 2-25 POD-H-FEM-H-x RF port and LED ........................................................................................................ 39 Figure 2-26 Communication Port ........................................................................................................................... 40 Figure 2-27 POD-H-COM-8 ..................................................................................................................................... 41 Figure 2-28 POD-H-COM-8 RF port and LED .......................................................................................................... 41 Figure 2-29 Communication Port ........................................................................................................................... 42 Figure 2-30 POD-H-COM-8 ..................................................................................................................................... 43 Figure 2-31 POD-H-DTM-8x8 RF port and LED ....................................................................................................... 43 Figure 2-32 Communication Port ........................................................................................................................... 44 Figure 2-33 POD-H-HOM-L ..................................................................................................................................... 45 Figure 2-34 POD-H-HOM-L RF port and LED .......................................................................................................... 45 Figure 2-35 optic port ............................................................................................................................................ 46 Figure 2-36 Communication Port ........................................................................................................................... 46 Figure 2-37 POD-H-HOM-H .................................................................................................................................... 48 Figure 2-38 POD-H-HOM-H RF port and LED ......................................................................................................... 48 Figure 2-39 optic port ............................................................................................................................................ 49 Figure 2-40 Communication Port ........................................................................................................................... 49 Figure 2-41 POD-H-STM-8x4-DL ............................................................................................................................ 51 Figure 2-42 POD-H-STM-8x4-UL ............................................................................................................................ 51
           User Manual for POD Systems                                                     Revision: 0.9    9  Figure 2-43 POD-H-STM-8x4-DL RF port and LED .................................................................................................. 52 Figure 2-44 POD-H-STM-8x4-UL RF port and LED .................................................................................................. 52 Figure 2-45 Communication Port ........................................................................................................................... 53 Figure 2-46 POD-H-PSU-x ....................................................................................................................................... 54 Figure 2-47 POD-H-PSU-x LED ................................................................................................................................ 54 Figure 2-48 Ethernet Port ...................................................................................................................................... 54 Figure 2-49 AC input on/off Switch & DC output on/off switch .................................................................................. 55 Figure 2-50 AC input port & DC output port .......................................................................................................... 55 Figure 2-51 Rack ID ................................................................................................................................................ 55 Figure 2-52 POD-H-CDU ......................................................................................................................................... 57 Figure 2-53 POD-H-FAU ......................................................................................................................................... 57 Figure 2-54 Remote Unit – 7/5/3 band .................................................................................................................. 59 Figure 2-55 Remote Unit External Interfaces ........................................................................................................ 62 Figure 2-56 Debug Window ................................................................................................................................... 63 Figure 2-57 Port name for each RU type ............................................................................................................... 64 Figure 2-58 Remote Unit – PS700/800 .................................................................................................................. 66 Figure 2-59 Remote Unit - PS700/800 External Interfaces .................................................................................... 67 Figure 2-60 Debug Window ................................................................................................................................... 68 Figure 2-61 Port name for each RU type ............................................................................................................... 69 Figure 2-62 Battery backup port ............................................................................................................................ 70 Figure 3-1 Head-end Unit Rack Mount (Front & Rear view) ................................................................................ 74 Figure 3-2 Head-end Unit - Rack Mount Sequence ............................................................................................. 75 Figure 3-3 Optic Connector Cleaning (left) and Optic Port Cleaning (right) ........................................................ 76 Figure 3-4 LC/APC Optic Connector Dust Cap ...................................................................................................... 76 Figure 3-5 3/5/7 band RU, PS700/800 RU – wall mount bracket ........................................................................ 77 Figure 3-6 3/5/7 band RU, PS700/800 RU – Install RU into wall mount bracket ................................................. 77 Figure 3-7 3/5/7 band RU, PS700/800 RU – RU installed on the wall ................................................................. 78 Figure 3-8 3/5/7 band RU grounding ................................................................................................................... 78 Figure 4-1 Head-end - cables ............................................................................................................................... 79 Figure 4-2 Cable Connection Example for frequency bands with FDD type ........................................................ 80 Figure 4-3 Cable Connection Example #1 for TDD 2.6G frequency band ............................................................ 82 Figure 4-4 Cable Connection Example for Public Safety 700/800 band .............................................................. 84 Figure 4-5 Cable Connection for FDD frequency band (MIMO) support ............................................................. 85 Figure 4-6 Connection Diagram for Rack Inter Connection ................................................................................. 87
           User Manual for POD Systems                                                     Revision: 0.9    10  Tables Table 1-1 POD System Scalability & Limitations ................................................................................................. 20 Table 2-1 Size, weight, and power consumption (Head-end Unit) ..................................................................... 22 Table 2-2 POD-H-DMCU LED Operation ............................................................................................................. 23 Table 2-3 Pin map - External Alarm Port ............................................................................................................ 25 Table 2-4 POD-H-DMCU - Alarms ....................................................................................................................... 25 Table 2-5 POD-H-SCM LED Operation ................................................................................................................ 28 Table 2-6 POD-H-SCM - Alarms .......................................................................................................................... 29 Table 2-7 POD-H-MCM LED Operation ............................................................................................................... 31 Table 2-8 POD-H-MCM - Alarms ......................................................................................................................... 32 Table 2-9 POD-H-FEM-L-x frequency range ........................................................................................................ 34 Table 2-10 POD-H-FEM-L-x Size, weight, and power consumption ...................................................................... 34 Table 2-11 POD-H-FEM-L-x LED Operation ........................................................................................................... 36 Table 2-12 POD-H-FEM-L-x - Alarms ..................................................................................................................... 36 Table 2-13 POD-H-FEM-H-x frequency range ....................................................................................................... 38 Table 2-14 POD-H-FEM-H-x Size, weight, and power consumption ..................................................................... 38 Table 2-15 POD-H-FEM-H-x LED Operation .......................................................................................................... 40 Table 2-16 POD-H-FEM-H-x - Alarms .................................................................................................................... 40 Table 2-17 POD-H-COM-8 LED Operation ............................................................................................................ 42 Table 2-18 POD-H-COM-8 - Alarms ...................................................................................................................... 42 Table 2-19 POD-H-DTM-8x8 LED Operation ......................................................................................................... 44 Table 2-20 POD-H-DTM-8x8 - Alarms ................................................................................................................... 44 Table 2-21 POD-H-HOM-L LED Operation ............................................................................................................ 45 Table 2-22 POD-H-HOM-L - Alarms ...................................................................................................................... 46 Table 2-23 POD-H-HOM-L LED Operation ............................................................................................................ 49 Table 2-24 POD-H-HOM-H - Alarms...................................................................................................................... 49 Table 2-25 POD-H-STM-8x4 LED Operation .......................................................................................................... 53 Table 2-26 POD-H-STM-8x8 - Alarms .................................................................................................................... 53 Table 2-27 POD-H-PSU-x LED Operation .............................................................................................................. 54 Table 2-28 Rack ID ................................................................................................................................................ 56 Table 2-29 POD-H-PSU - Alarms ........................................................................................................................... 56 Table 2-30 POD-H-FAU - Alarms ........................................................................................................................... 58 Table 2-31 3/5/7 band RU - 700M, SMR800 + 850M Specifications .................................................................... 60 Table 2-32 3/5/7 band RU – PCS, AWS Specifications .......................................................................................... 60 Table 2-33 3/5/7 band RU – WCS, 2.6G Specifications ........................................................................................ 61 Table 2-34 7/5/3 band RU LED Operation ............................................................................................................ 62 Table 2-35 3/5/7 band RU – Alarms ..................................................................................................................... 65 Table 2-36 PS700/800 RU - Specifications ............................................................................................................ 67 Table 2-37 7/5/3 band RU LED Operation ............................................................................................................ 68 Table 2-38 Pin map - Battery Backup Port ............................................................................................................ 70 Table 2-39 PS700/800 band RU – Alarms ............................................................................................................. 70 Table 5-1 POD DAS 2-Band RU Electrical Specifications (POD-R-P78-27-AC/DC) ............................................... 92 Table 5-2 POD DAS 7-Band RU Electrical Specifications (POD-R-7S8CPAWB-2730-AC/DC) ............................... 93 Table 5-3 Basic Model and Additional Models on 2-Band Remote Unit ............................................................ 94 Table 5-4 Basic Model and Additional Models on 7-Band Remote Unit ............................................................ 94
           User Manual for POD Systems                                                     Revision: 0.9    11  SAFETY AND REGUALTION WARNING NOTICE Only qualified personnel should handle the POD equipment. Any person involved in installation or operation of the POD should understand and follow these safety guidelines.  REGULATION Obey all general and regional installation and safety regulations to prevent any kinds of safety accidents such as potential electric shock, or RF exposure while installation, maintenance, or operation.   FCC REGULATION  Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor‐only restrictions is prohibited.   FCC Part 15.19 Statements - This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any  interference received, including interference that may cause undesired operation.   FCC Part 15.105 statement  - This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses,  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the instruction  manual,  may  cause  harmful  interference  to  radio  communications.  Operation  of  this equipment in a residential area is likely to  cause harmful interference in which case the user will be required to correct the interference at his own expense.   FCC Part 15.21 statement - Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.   RF Exposure Statement - The antenna(s) must be installed such that a minimum separation distance of at least 60 cm with 3dBi antenna gain or 300 cm with 11dBi antenna gain or  is maintained between the radiator (antenna) and all persons at all times. This device must not be co-located or operating in conjunction with any other antenna or transmitter.   FCC part 20 Industrial Booster statement (FCC ID: ZUQR7S8CPAWB-2730 & ZUQR-P78-27) - WARNING.  This  is  NOT a  CONSUMER  device.  It  is  designed  for  installation  by  FCC LICENSEES  and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation.   FCC part 90 Industrial Booster statement - THIS IS A 90.219 CLASS B DEVICE (FCC ID: ZUQR-P78-27) - WARNING.  This  is  NOT a  CONSUMER  device.  It  is  designed  for  installation  by  FCC LICENSEES  and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of FCC Licensee to operate this  device.  You  MUST  register  Class  B  signal  boosters  (as  defined  in  47  CFR  90.219)  online  at
           User Manual for POD Systems                                                     Revision: 0.9    12  www.fcc.gov/signal-boosters/registration.  Unauthorized  use  may  result  in  significant  forfeiture penalties, including penalties in excess of $100,000 for each continuing violation.   FCC part 27.5 / SRSP 518 (FCC ID: ZUQR7S8CPAWB-2730) - Antennas must be installed in accordance with FCC 27.50 and SRSP 518.  With 11dBi gain antennas the height of the antenna above average terrain (HAAT) must not exceed 4777m for IC.  For different gain antennas refer to the relevant rules.   FCC part 90.635 requirement (FCC ID: ZUQR-P78-27) - Antennas must be installed in accordance with FCC 90.635. With 11dBi gain antennas the height of the antenna above average terrain (HAAT) is permitted over 1372m. For different gain antennas refer to the relevant rules.   Fixed stations operating in the 1710-1755 MHz band are limited to a maximum antenna height of 10 meters above ground.  IC REGULATION  RSS-131 Section 5.3 – (The input and output impedances) - The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple  carrier signals are present,  the rating  would have  to be  reduced by 3.5 dB,  especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device.  RSS-GEN, Sec. 7.1.2 – (transmitters) - Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference  to  other users,  the  antenna  type  and  its  gain  should  be  so  chosen  that  the  equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. - Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionneravec une  antenne  d’un  type  et  d’un  gain  maximal  (ou  inférieur)  approuvé  pour  l’émetteur  par  Industrie Canada.  Dans  le  but  de  réduire  les  risques  de  brouillage  radioélectrique  à  l’intention  desautres utilisateurs, il  faut  choisir le type  d’antenne  et son  gain de sorte  que la  puissance  isotroperayonnée quivalente  (p.i.r.e.)  ne  dépassepas  l’intensité  nécessaire  à  l’établissement  d’une  communication satisfaisante.  RSS-GEN, Sec. 7.1.2 – (detachable antennas) - This radio transmitter (identify the device by certification number, or model number if Category II)has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. - Le présent émetteur radio (identifier le dispositif par son numéro de certification  ou son numéro de modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner avec  les  types  d’antenne  énumérés  ci-dessous  et  ayant  un  gain  admissible  maximal  et  l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste,ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
           User Manual for POD Systems                                                     Revision: 0.9    13   RF Radiation Exposure  - This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 60 cm with 3dBi antenna gain or 300 cm with 11dBi antenna gain between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF exposure will be addressed at time of installation and the use of higher gain antennas require larger separation distances. - L’antenne (ou les antennes) doit être installée de façon à maintenir à tout instant une distance minimum de au moins 60 cm avec le gain d'antenne 3dBi ou 300 cm avec 11dBi gain d'antenne entre la source de radiation  (l’antenne) et  toute personne  physique.  Cet  appareil ne  doit  pas  être installé ou utilisé en conjonction avec une autre antenne ou émetteur.  ELECTRIC SHOCK The POD System uses the AC or DC power with high voltage level which could result in electric shock and may cause severe injury.  LASER SAFETY To avoid eye injury, do not look directly into the optical ports, patch cords or optical cables. Always assume that optical output is on. To avoid the potential of radiation exposure, do not leave optic connectors uncovered when not connected. To check fiber cable connection, use an optical power meter and this should be performed by only technicians familiar with fiber optic safety practices and procedures. This equipment uses a Class 1 LASER according to FDA/CDRH Rules. This product conforms to all applicable standards of 21 CFR Chapter 1, Subchapter J, Part 1040  SAFETY The POD system should not be modified or used for any other purposes without authority’s permission in any cases. This could cause fires, electric shock or other injuries.  Be careful not to touch the heat sink part to prevent any degree of burns from high temperature of the heat sink. Do not place the DAS equipments close to flammable materials which could reach high temperatures due to heat dissipation of the DAS equipments. While working with outdoor DAS equipment with door, make sure to securely fasten the door to prevent any kinds of damages from slamming shut due to abrupt wind.  UL REGULATION This equipment complies with UL Standard for safety.
           User Manual for POD Systems                                                     Revision: 0.9    14  1. POD SYSTEM OVERVIEW POD System  is a  compact and  flexible platform  which  is  designed to provide  effective  service  coverage  for various indoor and outdoor applications. POD system supports multiple wireless standards currently being used such as CDMA/EVDO, WCDMA and LTE, as well as high traffic capacity and flexible distribution by sectorization and various flexibilities for future expansions. POD  system  supports  effectively  DAS  Network  Management  system  by  using  Ethernet  communications connected to between Head-end Unit and Remote Unit.  1.1 Features of POD System  A unified platform - A single head-end unit supports low & high power RU, indoor & outdoor RU. - A  single  head-end  supports  all  commercial  frequencies  bands  from  700M  to  2.6G  and  public  safety frequencies bands including UHF/VHF, PS700 and PS800.  ALL IP structure - All modules and units have its unique IP address which is assigned automatically when installed.  Supported capacity per a DMCU - A DMCU supports up to 4 racks. (a rack can support up to 7 H-SRUs) - A DMCU supports up to 4 H-OIMs and 6 H-OEMs.   The User-friendly Web based GUI - Web based GUI interface at head-end unit and Remote Unit. - Firmware download for all connected active modules at remote site and right at the head-end - Sectorization/commissioning at remote site and right at the head-end  Easy installation, commissioning and optimization - Auto system commissioning - DAS tree/Inter-connection diagram/rack diagram - System configuration backup/restore   Monitoring functions for DAS system - Downlink spectrum monitoring which is built in H-FEM - SNMP/Remote monitoring & control - Uptime - Save log @H-DMCU, save alarm history @each module  Monitoring interface for other equipments connected to DAS - Ethernet port forward function - Input/output ports for external alarm monitoring  Hot Swap - All  modules installed in  H-SRU support  hot  swap function,  so  all the modules  can  be  replaced  without powering down H-SRU.   Documentation - Auto BOM Generation - System Information Generation - Provide external memory for saving documents such as closeout package, user manual  SMB-L connector (SMB with lock) - SMB-L connector makes RF cable connections between RF ports easier, comparing to SMA connector.
           User Manual for POD Systems                                                     Revision: 0.9    15  - The cable with SMB-L connector provides more stable tight connection because SMB-L connector has lock function, comparing to SMB connector. The cable with SMB connector might be untied or loosened easily by vibration or unintentional cable pulling. - The RF cable with SMB connector can be used instead of the RF cable with SMB-L connector because SMB-L connector has compatibility with SMB connector. 1.2 POD System Architecture Figure 1-1 represents the overall DAS block diagram of KMW DAS system, POD. POD consists of HEU (head-end Unit), and RU (Remote unit). HEU provides the interface between plurality of BTS and plurality of RUs, and RUs are deployed over multiple shadow regions to provide wireless service coverage to mobile users in shadow regions.   Figure 1-1  DAS Overall Block Diagram   Figure 1-1 shows general signal flow and module composition of POD DAS system. POD DAS System supports various methods to connect with BTS such as direct connection to BTS through RF coaxial cable, connection to BTS via antenna through BDA, and connection to BTS by CPRI digital interface over optic. If user wants air interface with BTS, it is necessary for user to select proper BDA product separately because POD DAS system does not include any kinds of BDA. H-FEM provides the interface between various base station having different frequency band/technology and POD DAS system, and H-COM combines downlink signal received from H-FEM and distributes uplink signals received from DTM to FEM. H-DTM combines downlink signals from H-COM and then distributes to H-HOM, also combines uplink signals from several H-HOM and then distributes to H-COM. H-HOM converts downlink RF signal received from H-DTM to optic signal and then transfers to RU, also converts uplink optic signal received from RU to RF signal and then transfers to H-DTM. RU provides wireless service coverage to users by transmitting downlink signal received from H-HOM through the antenna. Also, it transfers to HOM after converting uplink signal received from mobile stations through the antenna to optic signal.    Remote Sites Building #2Building #1IDF #3IDF #2IDF #1MDFRemote Site #2Remote Site #1RemoteeNB OIM-B OIM-SOptic(RF)FEMFEMeNB RFOptic(CPRI)FEMRFBDAeNB Air InterfaceFEMeNB RFFEMeNB RFRemote Site #3FEMRFBDAeNB Air InterfaceCOM-8 DTM 8x8STM 8x4COM-8 DTM 8x8DTM 8x8OEM-SRUOpticOpticOEM-BHOMRUOpticHOMRUOpticHOMIDF #3IDF #2IDF #1RURURUOpticIDF #4RUHead-endMDF: Main Distribution FrameIDF: Intermediate Distribution FrameCOAXOPTICCPRI
           User Manual for POD Systems                                                     Revision: 0.9    16   Figure 1-2  How it works Figure 1-2 is a practical example of POD DAS system. It shows how to distribute various BTS signals from Head-end Unit to multiple Remote Units. Especially, in case of buildings away from Head-end location which needs multiple remote units, it is composed by the structure which distributes to multiple remote units after transmitting signal to other building through only one optic line using H-OEM, not transmits the signal by individual optic line according to required the number of remote units.  Also, it supports the connection between Head-end and base station through optic line using H-OIM when base station is away from head-end location.    CoaxBTSBi-directional Amplifier or RepeaterCoaxOEM-SEquipment RoomOEM-SOIM_BOptic    BTSOIM-BBTSAir InterfaceServer AntennaBUILDING #1 BUILDING #2COAXOPTICCPRIHead-endRemote UnitBDAHOMDTMHOMDTMOEM-BOIM-SFEMSCMOpticDonor Antenna
           User Manual for POD Systems                                                     Revision: 0.9    17  1.3 POD System Configuration 1.3.1 SISO Configuration  Assumption - Supported frequency Band: 700M, SMR800, 850M, PCS, AWS, WCS, 2.6G - # of RU: 2  System Configuration Module or Unit Q’ty Comments H-DMCU or H-MCM 1 Main Controller H-PSU or H-PSM 1 Power Supply Unit H-FEM-L-7 1 700M H-FEM-L-S8 1 SMR800 H-FEM-L-C 1 850M H-FEM-L-P 1 PCS H-FEM-L-A 1 AWS H-FEM-L-W 1 WCS H-FEM-L-B 1 2.6G H-COM-8 1  H-HOM-L 1  7 band RU 2   Figure 1-3  SISO Configuration   FEM-L-WUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-AUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-7UL MONDL MONDL OutUL InUL MonDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-S8UL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-CUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-BUL MONDL  MONDLOutUL InUL MONDL MONDL OutUL InPWRALMPath APath B#1#2#3#4T-SyncKMWFEM-L-PDL OutUL MONUL InDL MONPWRALMPCSKMWRun Link ALM ResetENT Up Down ESCDMCU Web GUISCMKMWCOM-8PWRALMDLCOM#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8ULCOMDL ULKMWHOM-LPWRALMUL OutDL InT_SyncDLULDLULDLULDLULKMW# 1# 2# 3# 4ENTUpDownESCResetRunDMCUAlarmLinkHEAlarmRUAlarm12345 76 89 11 13 1510 12 14 1617 19 21 2318 20 22 2425 27 29 3126 28 30 32ModemWeb GUIKMWDMCUHPSUPowerAlarm#1             #2             #3             #4#5             #6             #7             #8DMCU   #1     #2     #3     #41 2  1 2Group  RackKMWBLANKKMW700MeNBSMR800850MPCSAWSWCS2.6GHeadend RUBLANKKMW
           User Manual for POD Systems                                                     Revision: 0.9    18  1.3.2 MIMO Configuration  Assumption - Supported frequency Band   SISO: 700M, SMR800, 850M, PCS, AWS, WCS, 2.6G  MIMO: 700M, PCS, AWS, 2.6G - # of RU: 2  System Configuration Module or Unit Q’ty Comments H-DMCU or H-MCM 1 Main Controller H-PSU or H-PSM 1 Power Supply Unit H-FEM-L-7 1 700M H-FEM-L-S8 1 SMR800 H-FEM-L-C 1 850M H-FEM-L-P 2 PCS H-FEM-L-A 1 AWS H-FEM-L-W 1 WCS H-FEM-L-B 1 2.6G H-COM-8 2  H-HOM-L 2  7 band RU 4    Figure 1-4  MIMO Configuration   FEM-L-WUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-AUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-7UL MONDL MONDL OutUL InUL MonDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-S8UL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-CUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-BUL MONDL  MONDLOutUL InUL MONDL MONDL OutUL InPWRALMPath APath B#1#2#3#4T-SyncKMWFEM-L-PDL OutUL MONUL InDL MONPWRALMPCSKMWRun Link ALM ResetENT Up Down ESCDMCU Web GUISCMKMWCOM-8PWRALMDLCOM#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8ULCOMDL ULKMWHOM-LPWRALMUL OutDL InT_SyncDLULDLULDLULDLULKMW# 1# 2# 3# 4ENTUpDownESCResetRunDMCUAlarmLinkHEAlarmRUAlarm12345 76 89 11 13 1510 12 14 1617 19 21 2318 20 22 2425 27 29 3126 28 30 32ModemWeb GUIKMWDMCUHPSUPowerAlarm#1             #2             #3             #4#5             #6             #7             #8DMCU   #1     #2     #3     #41 2  1 2Group  RackKMW700MMIMO #2eNBPCSMIMO #2AWSMIMO #22.6GMIMO #2HeadendRUFEM-L-PDL OutUL MONUL InDL MONPWRALMPCSKMW700MMIMO #1SMR800850MPCSMIMO #1AWSMIMO #1WCS2.6GMIMO #1 HOM-LPWRALMUL OutDL InT_SyncDLULDLULDLULDLULKMW# 1# 2# 3# 4MIMO #1 MIMO #2COM-8PWRALMDLCOM#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8ULCOMDL ULKMW
           User Manual for POD Systems                                                     Revision: 0.9    19  1.4 POD System Scalability & Limitation Figure 1-5 shows maximum capacity of POD system composed by one DMCU  Figure 1-5  POD System Scalability    SDENTUpDownESCResetRunDMCUAlarmLinkHEAlarmRUAlarm12345 76 89 11 13 1510 12 14 1617 19 21 2318 20 22 2425 27 29 3126 28 30 32ModemWeb GUIKMWSD SD SDRack #1 Rack #2 Rack #3 Rack #4SRU#01SRU#02SRU#03SRU#04SRU#05SRU#06SRU#07SRU#08SRU#09SRU#10SRU#11SRU#12SRU#13SRU#14SRU#15SRU#16SRU#17SRU#18SRU#19SRU#20SRU#21SRU#22SRU#23SRU#24SRU#25SRU#26DMCUPSU#1 PSU#2 PSU#3 PSU#4
           User Manual for POD Systems                                                     Revision: 0.9    20  Table 1-1  POD System Scalability & Limitations   Supported maximum number # of path/Module POD System1) /Rack /H-SRU H-DMCU 1       RACK 4       H-PSU 4 12)     H-SRU 26 7     H-FEM H-FEM-L 208 843) 124) 29) H-FEM-H 1 H-COM-8 26 26 124)   H-DTM 8x8 26 26 64)   HOM 32 28 45)   RU 2566) 2247) 328)   H-OIM-B 4 4 4   H-OEM-S 6 6 6   1) Table 1-1 shows hardware capacity of one POD system. 2) One H-PSU supports one rack with 7 H-SRU which is fully filled with modules. 3) The number of supported H-FEM/rack = 7 H-SRU x 12 H-FEM/H-SRU = 84 4) One H-SRU consists of 12 slots. So, it supports up to 12 modules with 1 slot size (H-FEM & H-COM-8) and 6 modules with 2 slot size (H-DTM 8x8). 5) The number of supported HOM/H-SRU is limited up to four (4). 6) The number of supported RU in POD system is limited up to 256. 7) The number of supported RU/rack = 7 SRU/rack x the number of supported RU/SRU = 224 8) The number of supported RU/H-SRU = 4 HOM/SRU x 4 path/HOM x 2 RU/path = 32 9) H-FEM-L-P (PCS) supports only one path.
           User Manual for POD Systems                                                     Revision: 0.9    21  2. POD SYSTEM COMPONENTS 2.1 Head-end Unit  Figure 2-1  Head-end Unit Front View   Figure 2-2  Head-end Unit Rear View    H-SRUFEM-L-WUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-AUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-7UL MONDL MONDL OutUL InUL MonDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-S8UL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-P7/P8UL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPS700PS800KMWFEM-L-CUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-BUL MONDL  MONDLOutUL InUL MONDL MONDL OutUL InPWRALMPath APath B#1#2#3#4T-SyncKMWFEM-L-PDL OutUL MONUL InDL MONPWRALMPCSKMWRun Link ALM ResetENT Up Down ESCDMCU Web GUISCMKMWCOM-8PWRALMDLCOM#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8ULCOMDL ULKMWDTM-8x8PWRALMKMWVHFUHF#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8DLMONDL ULVHFUHF#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8ULMONIN OUT IN OUTHOM-LPWRALMUL OutDL InT_SyncDLULDLULDLULDLULKMW# 1# 2# 3# 4SCM [                                                        FEM                                                   ] COM-8 DTM-8x8 HOM1 2 3 4 5 6 7 8 9 10 11 12KMWENTUpDownESCResetRunDMCUAlarmLinkHEAlarmRUAlarm12345 76 89 11 13 1510 12 14 1617 19 21 2318 20 22 2425 27 29 3126 28 30 32ModemWeb GUIKMWDMCUHPSUPowerAlarm#1             #2             #3             #4#5             #6             #7             #8DMCU   #1     #2     #3     #41 2  1 2Group  RackKMWDMCUH-PSUDMCUH-PSUH-SRUSCM[                                                        FEM                                                   ]COM-8DTM-8x8HOMDL / UL (A)UL Div (A)DL / UL (B)UL Div (B)700M┌┌└└DL / UL (A)UL Div (A)DL / UL (B)UL Div (B)P7/P8┌┌└└DL / UL (A)UL Div (A)DL / UL (B)UL Div (B)S8┌┌└└DL / UL (A)UL Div (A)DL / UL (B)UL Div (B)850M┌┌└└DL / UL (A)UL Div (A)PCS┌┌DL / UL (A)UL Div (A)DL / UL (B)UL Div (B)AWS┌┌└└DL / UL (A)UL Div (A)DL / UL (B)UL Div (B)WCS┌┌└└DL / UL (A)DL / UL (B)BRS┌└- 30 -- 30 -#12 #11 #10 #9 #8 #7 #6 #5 #4 #3 #2 #1HPSUFUSESpare FuseFANHPSUPower SWDMCU1 2 3External AlarmInput Output1 2 3 4 5 6 7 8#1 #2  #3  #4  #5   #6  #7 #8   DMCU HSRU
           User Manual for POD Systems                                                     Revision: 0.9    22   Head-end Unit consists of - H-DMCU (Head-end DAS Main Control Unit) - H-PSU(Head-end Power Supply Unit) - H-SRU(Head-end Subrack Unit) - H-SCM(Head-end Subrack Control Module) - H-FEM(Head-end Front End Module) - H-COM(Head-end Combing Module) - H-DTM(Head-end Distribution Module) - HOM(Head-end Optic Module) - H-STM(Head-end Sectorization Module) - H-OEM(Head-end Optic Expansion Module) - H-OIM(Head-end Optic Interface Module)  Specification - Size, weight, and power consumption Table 2-1  Size, weight, and power consumption (Head-end Unit)  Size(H x W x D) Weight Power consumption (W) inch mm lb Kg POD-H-DMCU 2.1 x 19.0 x 19.7 52.4 x 482.6 x 499.5 6.6 3.0 28.5 POD-H-SRU 7.0 x 19.0 x 19.7 177 x 482.6 x 499.5 16.3 7.4  POD-H-SCM 7.0 x 1.8 x 17.8 177 x 46.5 x 452.5 2.9 1.3 16.2 POD-H-MCM 7.0 x 3.1 x 17.8 177 x 79 x 452.5   24.0 POD-H-FEM-L Refer to Table 2-10 POD-H-FEM-H Refer to Table 2-14 POD-H-COM-8 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.5 2.5 4.8 POD-H-DTM-8x8 7.0 x 2.5 x 17.8 177 x 64.1 x 452.5 11.5 5.2 12 POD-H-HOM-L 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.5 2.5 30 POD-H-HOM-H 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 9 4.1 30 POD-H-STM-DL-8x4 7.0 x 2.5 x 17.8 177 x 64.1 x 452.5 11 5  POD-H-STM-UL-8x4 7.0 x 2.5 x 17.8 177 x 64.1 x 452.5 11 5  POD-H-OEM-B 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.3 2.4 30 POD-H-OEM-S 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.5 2.5 30 POD-H-OIM-B 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.3 2.4 30 POD-H-OIM-S 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.5 2.5 30 POD-H-PSU 1.7 x 19.0  x 19.7 44 x 482.6 x 499.5 13.9 6.3 85 @no load POD-H-PSM 7.0 x 2.5 x 17.8 177 x 64.1 x 452.5    POD-H-CDU 1.4 x 19.0 x 12.0 35.2 x 482.6 x 304.2 2.4 1.1  POD-H-FAU 1.4 x 17.3 x 10.6 36 x 440 x 270 3.5 1.6 12 - Operating temperature: 14 ~ 122F (-10 ~ 50C) - Power input  H-FEM,H-COM, H-STM, H-DTM, H-HOM, H-OIM, H-FAU: DC 24V  POD-H-PSU-AC/POD-H-PSM-AC: AC 100~240V (47~63Hz)  POD-H-PSU-DC/POD-H-PSM-DC: DC -48V
           User Manual for POD Systems                                                     Revision: 0.9    23  2.1.1 POD-H-DMCU (DAS Main Control Unit)   Figure 2-3  POD-H-DMCU 2.1.1.1 Functions and features - Controls,  monitors, and generates alarms for all connected modules and units in a POD DAS system - Supports up to 4 racks. - Supports up to 4 H-OIMs and up to 6 H-OEMs. - Provides web-based GUI interface to user - Provides the user interface to control and monitor using LCD window and key pad. - Send alarms to O&M system by SNMP. - Ethernet port forward function - Provides external input/output ports for external alarm monitoring 2.1.1.2 Specifications - Size, weight, and power consumption: refer to Table 2-1 2.1.1.3 LED, LCD & Key PAD, Reset  Figure 2-4  LED, LCD & Key PAD, Reset  LCD window and key pad - H-DMCU provides the user interface to control and monitor using LCD window and key pad.  Reset - Used for H-DMCU reset.  LED Table 2-2  POD-H-DMCU LED Operation  Specifications Run Solid Green When power is on. OFF When power is off. Link Solid Yellow When H-DMCU cannot communicate with at least one module among modules which are directly connected to H-DMCU such as H-SCM or H-PSU. ENTUpDownESCResetRunDMCUAlarmLinkHEAlarmRUAlarm12345 76 89 11 13 1510 12 14 1617 19 21 2318 20 22 2425 27 29 3126 28 30 32ModemWeb GUIKMWHPSUPower SWDMCU1 2 3External AlarmInput Output1 2 3 4 5 6 7 8ENTUpDownESCResetRunDMCUAlarmLinkHEAlarmRUAlarm
           User Manual for POD Systems                                                     Revision: 0.9    24  OFF When H-DMCU communicates with all modules which are directly connected with H-DMCU such as H-SCM or H-PSU. DMCU Alarm Solid Yellow When H-DMCU has minor alarm. OFF When H-DMCU has no alarm. HE Alarm Solid Yellow When at least one module or unit in the head-end has minor alarm. Solid Red When at least one module or unit in the head-end has major alarm. OFF When all modules and units in the head-end have no alarm. RU Alarm Solid Yellow When at least one RU has minor alarm. Solid Red When at least one RU has major alarm. OFF When all RUs have no alarm. 2.1.1.4 Ethernet Ports  Figure 2-5  Ethernet Ports  Modem port - Connected to wireless modem which provides connection with O&M center.  Web GUI port - Used to access to web-based GUI using notebook or desktop PC.  1~32 Ethernet Port - Connected to H-SRU  or H-PSU so that H-DMCU can monitor and  control  the connected  H-PSUs and all modules installed in H-SRU. - Connected to external device to provide port forwarding function. 2.1.1.5 DC power input port & power switch 24V DC power for DMCU is fed from POD-H-PSU and can be turned on or off by power switch.    Figure 2-6  DC power input port & power switch 2.1.1.6 External Alarm Port H-DMCU provides 4 alarm inputs to get the alarm statuses of  the connected any external devices. Then, the input conditions are reported to the O&M system. H-DMCU also provides 4 alarm outputs to control the external devices or to signal any alarm condition or status information to the external devices.  HPSUPower SW
           User Manual for POD Systems                                                     Revision: 0.9    25   Figure 2-7  External Alarm Ports Table 2-3  Pin map - External Alarm Port Pin Assign Specifications 1 External Input #1 External Alarm input #1 pin 2 External Input #2 External Alarm input #2 pin 3 External Input #3 External Alarm input #3 pin 4 External Input #4 External Alarm input #4 pin 5 External Output #1 External Alarm output #1 pin 6 External Output #2 External Alarm output #2 pin 7 External Output #3 External Alarm output #3 pin 8 External Output #4 External Alarm output #4 pin 2.1.1.7 Ground port - Refer to section 3.2.2 2.1.1.8 Alarms Table 2-4  POD-H-DMCU - Alarms Alarm Name Description Remedy Alarm Severity LED color High Temperature Temperature high Check environment Minor Yellow Low Temperature Temperature too low Minor Yellow Head-end Composite Head-end composite alarms Check Head-end unit Major/Minor Red/ Yellow RU Composite RU composite alarms Check RU Major/Minor Red/ Yellow External Input (1~4) External input signal Check connected external unit Minor Yellow AC Fail H-PSU AC Fail Check H-PSU Major Red DC Fail H-PSU DC Fail Check H-PSU Major Red PSU Comm. Fail H-PSU Communication Fail Check UDP cable connection Minor Yellow SCM Comm. Fail H-SCM Communication Fail Check UDP cable connection Minor Yellow    External AlarmInput Output1 2 3 4 5 6 7 8
           User Manual for POD Systems                                                     Revision: 0.9    26  2.1.2 POD-H-SRU  Figure 2-8  POD-H-SRU Front View  Figure 2-9  POD-H-SRU Rear View 2.1.2.1 Functions and features - One H-SRU supports 12 slot including one SCM and other modules such as H-FEM, H-COM, H-DTM, HOM. - Supplies 24V DC power received from H-PSU to each individual module through the backboard. - Supplies 24V DC power to H-FAU (Fan Unit) for dissipating heat comes from the modules installed in POD-H-SRU. - Provides communication path between installed modules and SCM through backboard. 2.1.2.2 Specifications - Size, weight, and power consumption : refer to Table 2-1 2.1.2.3 DC input port & Fuse - 30 -- 30 -#12 #11 #10 #9 #8 #7 #6 #5 #4 #3 #2 #1HPSUFUSESpare FuseFAN
           User Manual for POD Systems                                                     Revision: 0.9    27   Figure 2-10  DC input port & Fuse  DC Input port - The 24V DC power is supplied from H-PSU through this port, and this port includes H-SRU ID, rack ID which is set by ‘Rack ID’ dip switch in H-PSU.  FUSE - Current capacity: 15A - The fuse protects the damages of all modules installed in H-SRU due to high current. - H-SRU provides spare fuse for just in case fuse is broken. 2.1.2.4 FAN port  Figure 2-11  FAN port - DC Power is supplied into the FAN Unit through this port. - FAN fail alarm is transferred to H-SCM through this port. 2.1.2.5 Ground port - Refer to section 3.2.2   - 30 -HPSUFUSE- 30 -Spare FuseFAN
           User Manual for POD Systems                                                     Revision: 0.9    28  2.1.3 POD-H-SCM  Figure 2-12 POD-H-SCM 2.1.3.1 Functions and features - One H-SCM can be installed in one H-SRU. - Provides web-based GUI interface to user - Provides the user interface to control and monitor using LCD window and key pad. - Provides physical path between H-DMCU and all modules in H-SRU - Controls FAN on/off and FAN speed and monitors FAN alarm. - Periodically, gather the data from all modules in H-SRU and send it to H-DMCU through DMCU port. - Periodically, gather the data from RUs connected to H-HOM in H-SRU and send it to H-DMCU through DMCU port. 2.1.3.2 Specifications - Size, weight, and power consumption : refer to Table 2-1 2.1.3.3 LED, LCD & Key PAD, Reset  Figure 2-13  LED, LCD & Key PAD  LCD window and key pad - H-SCM provides the user interface to control and monitor using LCD window and key pad.  Reset - Used for H-SCM reset. Table 2-5  POD-H-SCM LED Operation  Specifications RUN Solid Green When power is on. OFF When power is off. Link Solid Yellow When H-SCM cannot communicate with at least one module among modules installed in H-SRU. OFF When H-SCM communicates with all modules installed in H-SRU. Alarm Solid Red When H-SCM has major alarm. Run Link ALM ResetENT Up Down ESCDMCU Web GUISCMKMWRun Link ALM ResetENT Up Down ESC
           User Manual for POD Systems                                                     Revision: 0.9    29  Solid Yellow When H-SCM has minor alarm. OFF When H-SCM has no alarm. 2.1.3.4 Ethernet Port  Figure 2-14  Ethernet Port  DMCU port - Provides physical communication path between H-DMCU and all modules in H-SRU by connecting DMCU port of H-SCM to available one port among Ethernet port #1~#32 of H-DMCU.  Web GUI port - Used to access to web-based GUI using notebook or desktop PC. 2.1.3.5 Communication port  Figure 2-15  Communication Port - This port provides communication path between H-FEM-H-x,  H-COM, H-DTM,  H-STM, HOM-x or H-SCM installed in H-SRU through backboard of H-SRU. - +24V DC is provided through this communication port from backboard of H-SRU. - H-SCM acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-SCM is assigned automatically using the acquired ID information. 2.1.3.6 Alarms Table 2-6  POD-H-SCM - Alarms Alarm Name Description Remedy Alarm Severity LED color High Temperature Temperature high Check environment Minor Yellow Low Temperature Temperature too low Minor Yellow FAN FAN Fail Check FAN Minor Yellow Module Comm. Fail Module Communication  Fail Check Module connection Minor Yellow
           User Manual for POD Systems                                                     Revision: 0.9    30  2.1.4 POD-H-MCM                 Figure 2-16 POD-H-MCM 2.1.4.1 Functions and features - In case of small size DAS system, H-MCM can replace H-DMCU. - Controls, monitors, and generates alarms for all modules and units connected to H-MCM via Ethernet cable, backboard of H-SCM, or optic cable. - Provides web-based GUI interface to user - Provides the user interface to control and monitor using LCD window and key pad. - Send alarms to O&M system by SNMP. - Input/output ports for external alarm monitoring 2.1.4.2 Specifications - Size, weight, and power consumption : refer to Table 2-1 2.1.4.3 LED, LCD & Key PAD, Reset External AlarmInputOutput1234
           User Manual for POD Systems                                                     Revision: 0.9    31   Figure 2-17  LED, LCD & Key PAD, Reset  LCD window and key pad - H-MCM provides the user interface to control and monitor using LCD window and key pad.  Reset - Used for H-MCM reset.  LED Table 2-7  POD-H-MCM LED Operation  Specifications Run Solid Green When power is on. OFF When power is off. Link Blink Green When H-MCM cannot communicate with at least one module or units connected to H-MCM. OFF When H-MCM communicates all modules and units connected to H-MCM. MCM Alarm Blink Green When H- MCM itself has minor alarm. OFF When H- MCM itself has no alarm. HE Alarm Blink Green When at least one module or unit connected to H-MCM has minor alarm. Solid Red When at least one module or unit connected to H-MCM has major alarm. OFF When all modules and units connected to H-MCM have no alarm. RU Alarm Blink Green When at least one RU connected to H-MCM has minor alarm. Solid Red When at least one RU connected to H-MCM has major alarm. OFF When all RUs connected to H-MCM have no alarm.  2.1.4.4 Ethernet Ports  Figure 2-18  Ethernet ports  Modem port - Connected to wireless modem which provides connection with O&M center.  Web GUI port - Used to access to web-based GUI using notebook or desktop PC.  HSRU1~HSRU3 Ethernet Port - Connected to H-SRU so that H-MCM can monitor and control the connected all modules installed in H-SRU. HSRU 1HSRU 2HSRU 3ModemWeb GUI
           User Manual for POD Systems                                                     Revision: 0.9    32  2.1.4.5 External Alarm Ports POD-H-MCM provides 2 alarm inputs to get the alarm statuses of the connected any external devices. Then, the input conditions are reported to the O&M system. POD-H-MCM also provides 2 alarm outputs to control the external devices or to signal any alarm condition or status information to the external devices.    Figure 2-19  External Alarm Ports 2.1.4.6 Communication port  Figure 2-20  Communication Port - This port provides communication path between H-FEM-H-x,  H-COM, H-DTM,  H-STM, HOM-x or H-SCM installed in H-SRU through backboard of H-SRU. - +24V DC is provided through this communication port from backboard of H-SRU. - H-MCM acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-MCM is assigned automatically using the acquired ID information. 2.1.4.7 Alarms Table 2-8  POD-H-MCM - Alarms Alarm Name Description Remedy Alarm Severity LED color High Temperature Temperature high Check environment Minor Yellow Low Temperature Temperature too low Minor Yellow Head-end Composite Head-end composite alarms Check Head-end unit Major/Minor Red/ Yellow RU Composite RU composite alarms Check RU Major/Minor Red/ Yellow External Input (1~2) External input signal Check connected External unit Minor Yellow AC Fail H-PSU AC Fail Check H-PSU Major Red DC Fail H-PSU DC Fail Check H-PSU Major Red SCM Comm. Fail H-SCM Communication  Fail Check UDP cable connection Minor Yellow   External AlarmInput12Output34
           User Manual for POD Systems                                                     Revision: 0.9    33  2.1.5 POD-H-FEM-L-x FEM-L-7 FEM-L-P7/P8 FEM-L-S8 FEM-L-C FEM-L-P FEM-L-A FEM-L-W FEM-L-B                 Figure 2-21 POD-H-FEM-L-x Front & Rear View    FEM-L-7UL MONDL MONDL OutUL InUL MonDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-P7/P8UL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPS700PS800KMWFEM-L-S8UL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-CUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-PDL OutUL MONUL InDL MONPWRALMPCSKMWFEM-L-AUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-WUL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BKMWFEM-L-BUL MONDL  MONDLOutUL InUL MONDL MONDL OutUL InPWRALMPath APath B#1#2#3#4T-SyncKMWDL / UL (A)UL Div (A)DL / UL (B)UL Div (B)700M┌┌└└DL / UL (A)UL Div (A)DL / UL (B)UL Div (B)P7/P8┌┌└└DL / UL (A)UL Div (A)DL / UL (B)UL Div (B)S8┌┌└└DL / UL (A)UL Div (A)DL / UL (B)UL Div (B)850M┌┌└└DL / UL (A)UL Div (A)PCS┌┌DL / UL (A)UL Div (A)DL / UL (B)UL Div (B)AWS┌┌└└DL / UL (A)UL Div (A)DL / UL (B)UL Div (B)WCS┌┌└└DL / UL (A)DL / UL (B)BRS┌└
           User Manual for POD Systems                                                     Revision: 0.9    34  2.1.5.1 Functions and features - Provides the interface between DAS and Base station - Provides independent two RF path except H-FEM-L-P - ALC function for DL/UL Path - Spectrum monitoring function for DL Input - TDD Switching for TD-LTE (POD-H-FEM-L-B only) -  Acquisition and transmission of synchronization signal  (POD-H-FEM-L-B only) 2.1.5.2 Specifications - Frequency range Table 2-9  POD-H-FEM-L-x frequency range  Downlink Uplink Comments POD-H-FEM-L-7 728~756 MHz 698~716 MHz (Lower ABC)  777~787 MHz (Upper C)  POD-H-FEM-L-P7P8 758~775 MHz (PS700) 851~869 MHz (PS800) 788~805 MHz (PS700)  806~824 MHz (PS800)  POD-H-FEM-L-S8 851~869 MHz 806~824 MHz  POD-H-FEM-L-C 869~894 MHz 824~849 MHz  POD-H-FEM-L-P 1930~1995 MHz 1850~1915 MHz  POD-H-FEM-L-A 2110~2180 MHz 1710~1780 MHz (1710~1755 MHz for BDA application)  POD-H-FEM-L-W 2350~2360 MHz 2305~2315 MHz  POD-H-FEM-L-B 2496~2690 MHz TDD - Input range   -15~20dBm Table 2-10 POD-H-FEM-L-x Size, weight, and power consumption  Size(H x W x D) Weight Power consumption (W) inch mm lb Kg POD-H-FEM-L-7 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 4.9 2.2 22 POD-H-FEM-L-P7P8 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 4.9 2.2 16 POD-H-FEM-L-S8 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 4.9 2.2 16 POD-H-FEM-L-C 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 4.9 2.2 15 POD-H-FEM-L-P 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 4.9 2.2 9 POD-H-FEM-L-A 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 4.9 2.2 12 POD-H-FEM-L-W 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 4.9 2.2 12 POD-H-FEM-L-B 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 4.9 2.2 13
           User Manual for POD Systems                                                     Revision: 0.9    35  2.1.5.3 RF Port and LED  H-FEM-L-7/P7P8/S8/C/A/W H-FEM-L-P H-FEM-L-B Front Panel    Rear Panel    Figure 2-22 POD-H-FEM-L-x RF port and LED  RF Ports - DL/UL-A(B), UL-Div A(B)  Linked  to BTS RF ports  When the RF port linked to BTS is duplex port, connect to DL/UL-A(B)  When the RF ports linked to BTS are TX/RX port, connect DL/UL-A(B) to TX port and UL Div A(B) to RX port.  Connector Type: SMA Female - Connector Type: SMA DL MON-A(B), UL MON-A(B)  Used to monitor DL input or UL output for path A or B  Connector Type: SMB-L Female - DL OUT-A(B), UL IN-A(B)  DL OUT- A(B): DL output port for path A or B, Linked to H-COM or H-DTM  UL IN- A(B): UL input port for path A or B, Linked to H-COM or H-DTM  Connector Type: SMB-L Female    UL MONDL MONDL OutUL InUL MONDL MONDL OutUL InPWRALMPath APath BDL OutUL MONUL InDL MONPWRALMUL MONDL  MONDLOutUL InUL MONDL MONDL OutUL InPWRALMPath APath B#1#2#3#4T-SyncDL / UL (A)UL Div (A)DL / UL (B)UL Div (B)DL / UL (A)UL Div (A)DL / UL (A)DL / UL (B)
           User Manual for POD Systems                                                     Revision: 0.9    36   LED Table 2-11 POD-H-FEM-L-x LED Operation  Specifications PWR Solid Green When power is on. Off When power is off. ALM Off When H-FEM-L-x has no alarms. Solid Yellow When H-FEM-L-x has minor alarm. Solid Red When H-FEM-L-x has major alarm. DL Out Blink Green At the cable connection guide, green led blinks to indicate which RF ports should be connected to. UL In Blink Green T-sync #1~#4 Blink Green 2.1.5.4 Communication port  Figure 2-23  Communication Port - This port provides communication path between H-FEM-L-x and H-SCM through backboard of H-SRU. - +24V DC is provided through this communication port from backboard of H-SRU. - H-FEM-L-x acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-FEM-L-x is assigned automatically using the acquired ID information. 2.1.5.5 Alarms Table 2-12 POD-H-FEM-L-x - Alarms Alarm Name Description Remedy Alarm Severity LED color High Temperature Temperature too high Check environment Major Red Temperature high Minor Yellow Low Temperature Temperature too low Minor Yellow Downlink High Input power RF signal too high Check H-FEM downlink input level/ attenuator configuration/ALC status Major Red RF signal high Major Yellow Uplink High Output Power RF signal too high Check H-FEM uplink input level/ attenuator configuration/ALC status Major Red RF signal high Major Yellow Downlink Low Input Power RF signal too low Check H-FEM downlink input level/ attenuator configuration/RF cabling Minor Yellow Link Communication fail Check pin of communication port/ assigned IP address Major Yellow Freeze The final stage of Shutdown process Check if shutdown process is going again after reset Major Red Downlink ALC Activation ALC activation Check H-FEM downlink input level/ attenuator configuration Warning Yellow Sync fail (H-FEM-L-B only) No TDD sync signal is acquired Check H-FEM downlink signal input received from BTS Major Yellow
           User Manual for POD Systems                                                     Revision: 0.9    37  2.1.6 POD-H-FEM-H-x FEM-H-7 FEM-H-P7 FEM-H-S8(P8) FEM-H-C FEM-H-P FEM-H-A FEM-H-W FEM-H-B                 Figure 2-24 POD-H-FEM-H-x Front & Rear View   FEM-H-7DL OutUL MONUL InDL MONPWRALM700MKMWFEM-H-P7DL OutUL MONUL InDL MONPWRALMPS700KMWFEM-H-S8DL OutUL MONUL InDL MONPWRALMSMR800FEM-H-CDL OutUL MONUL InDL MONPWRALM850MKMWFEM-H-PKMWDL OutUL MONUL InDL MONPWRALMPCSFEM-H-ADL OutUL MONUL InDL MONPWRALMAWSKMWFEM-H-WDL OutUL MONUL InDL MONPWRALMWCSKMWFEM-H-BDL OutUL MONUL InDL MONPWRALMBRSKMW#1#2#3#4T-SyncUL DivUL DivUL DivUL DivUL DivUL DivUL Div
           User Manual for POD Systems                                                     Revision: 0.9    38  2.1.6.1 Functions and features - Provides the interface between DAS and Base station - ALC function for DL/UL Path - Spectrum monitoring function for DL Input - TDD Switching for TD-LTE (POD-H-FEM-H-B only) -  Acquisition and transmission of synchronization signal  (POD-H-FEM-H-B only) 2.1.6.2 Specifications  Frequency range Table 2-13 POD-H-FEM-H-x frequency range  Downlink Uplink Comments POD-H-FEM-L-7 728~756 MHz 698~716 MHz (Lower ABC)  777~787 MHz (Upper C)  POD-H-FEM-L-P7 758~775 MHz 788~805 MHz  POD-H-FEM-L-P8 851~869 MHz 806~824 MHz  POD-H-FEM-L-S8 851~869 MHz 806~824 MHz  POD-H-FEM-L-C 869~894 MHz 824~849 MHz  POD-H-FEM-L-P 1930~1995 MHz 1850~1915 MHz  POD-H-FEM-L-A 2110~2180 MHz 1710~1780 MHz (1710~1755 MHz for BDA application)  POD-H-FEM-L-W 2350~2360 MHz 2305~2315 MHz  POD-H-FEM-L-B 2496~2690 MHz TDD  Input range -  15~46dBm Table 2-14 POD-H-FEM-H-x Size, weight, and power consumption  Size(H x W x D) Weight Power consumption (W) inch mm lb Kg POD-H-FEM-H-7 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.7 2.6 11.5 POD-H-FEM-H-P7 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.7 2.6 8 POD-H-FEM-H-P8(S8) 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.7 2.6 8 POD-H-FEM-H-C 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.7 2.6 8 POD-H-FEM-H-P 7.0 x 2.5 x 17.8 177 x 63.8 x 452.5 5.7 2.6 9 POD-H-FEM-H-A 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 7.7 3.5 9.5 POD-H-FEM-H-W 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.7 2.6 6 POD-H-FEM-H-B 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.7 2.6 6 POD-H-FEM-L-B 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 5.7 2.6 7.5
           User Manual for POD Systems                                                     Revision: 0.9    39  2.1.6.3 RF port and LED  H-FEM-L-7/P7/P8/S8/C/P/A/W H-FEM-L-B Front Panel   Rear Panel   Figure 2-25 POD-H-FEM-H-x RF port and LED  RF Ports - DL/UL, UL-Div  Linked  to BTS RF ports  When the RF port linked to BTS is duplex port, connect to DL/UL  When the RF ports linked to BTS are TX/RX port, connect DL/UL to TX port and UL Div to RX port.  Connector Type  Mini DIN Female for DL/UL port  SMA Female for UL div port - Connector Type: SMA DL MON, UL MON  Used to monitor DL input or UL output  Connector Type: SMB-L Female - DL OUT, UL IN  DL OUT: DL output port, Linked to H-COM or H-DTM  UL IN: UL input port, Linked to H-COM or H-DTM  Connector Type: SMB-L Female DL OutUL MONUL InDL MONPWRALMDL OutUL MONUL InDL MONPWRALM#1#2#3#4T-SyncUL DivDL/ULDL/UL
           User Manual for POD Systems                                                     Revision: 0.9    40   LED Table 2-15 POD-H-FEM-H-x LED Operation  Specifications PWR Solid Green When power is on. Off When power is off. ALM Off When H-FEM-H-x has no alarms. Solid Yellow When H-FEM-H-x has minor alarm. Solid Red When H-FEM-H-x has major alarm. DL Out Blink Green At the cable connection guide, green led blinks to indicate which RF ports should be connected to. UL In Blink Green T-sync #1~#4 Blink Green 2.1.6.4 Communication port  Figure 2-26  Communication Port - This port provides communication path between H-FEM-H-x and H-SCM through backboard of H-SRU. - +24V DC is provided through this communication port from backboard of H-SRU. - H-FEM-H-x acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-FEM-H-x is assigned automatically using the acquired ID information. 2.1.6.5 Alarms Table 2-16 POD-H-FEM-H-x - Alarms Alarm Name Description Remedy Alarm Severity LED color High Temperature  Temperature too high Check environment Major Red Temperature high Minor Yellow Low Temperature Temperature too low Minor Yellow Downlink High Input Power RF signal too high Check H-FEM downlink input level/ attenuator configuration/ALC status Major Red RF signal high Major Yellow Uplink High Output Power RF signal too high Check H-FEM uplink input level/ attenuator configuration/ALC status Major Red RF signal high Major Yellow Downlink Low Input Power RF signal too low Check H-FEM downlink input level/ attenuator configuration/RF cabling Minor Yellow Link Communication fail Check pin of communication port/ assigned IP address Major Yellow Freeze The final stage of Shutdown process Check if shutdown process is going again after reset Major Red Downlink ALC Activation ALC activation Check H-FEM downlink input level/ attenuator configuration Warning Yellow Sync fail (H-FEM-L-B only) No TDD sync signal is acquired Check H-FEM downlink signal input received from BTS Major Yellow
           User Manual for POD Systems                                                     Revision: 0.9    41  2.1.7 POD-H-COM-8  Figure 2-27 POD-H-COM-8 2.1.7.1 Functions and features - Combines DL output signals received from H-FEM and transfers to H-DTM, or H-HOM - Receives UL signal from H-DTM, or H-HOM and distributes to H-FEM - Control Power Ratio for multiple H-FEM with same frequency band to share DL output power at RU - ALC function for DL/UL Path - To minimize negative effects by unused input/output ports such as the degradation of VSWR or isolation between ports, the unused ports can be switched into 50 ohm termination by user. - When any one sector or DAS system needs low power RU less than 4, H-COM can be connected to H-HOM-L directly without H-DTM.  In this case, the attenuator in the common path of H-COM should add 15dB attenuation using web based GUI to compensate the loss of H-DTM.. 2.1.7.2 Specifications - Frequency range: 600~2700MHz - Maximum RF Power: -10dBm@DL, -25dBm@UL - Size, weight, and power consumption : refer to Table 2-1 2.1.7.3 RF port and LED  Figure 2-28 POD-H-COM-8 RF port and LED  RF Port - DL #1 ~ #8  Receives downlink signal from up to 8 H-FEM  Connected to DL output port of H-FEM  Connector Type: SMB-L Female - DL COM  Combines inputted downlink signals from DL #1 to DL #8 and outputs to H-DTM or H-HOM  Connected to DL input port of H-DTM, or H-HOM  Connector Type: SMB-L Female - UL COM  Receives uplink signal from H-DTM or H-HOM  Connected to UL output port of H-DTM, or H-HOM  Connector Type: SMB-L Female - UL #1 ~ #8  Divides inputted uplink signals from UL COM port and outputs to H-FEM COM-8PWRALMDLCOM#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8ULCOMDL ULKMWPWRALMDLCOM#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8ULCOMDL UL
           User Manual for POD Systems                                                     Revision: 0.9    42   Connected to UL input port of H-FEM  Connector Type: SMB-L Female  LED Table 2-17 POD-H-COM-8 LED Operation  Specifications PWR Solid Green When power is on. Off When power is off. ALM Off When POD-H-COM-8 has no alarms. Solid Yellow When POD-H-COM-8 has minor alarm. Solid Red When POD-H-COM-8 has major alarm. DL #1 ~ #8 Blink Green At the cable connection guide, green led blinks to indicate which RF ports should be connected to. DL COM Blink Green UL #1 ~ #8 Blink Green UL COM Blink Green 2.1.7.4 Communication port  Figure 2-29  Communication Port - This port provides communication path between H-COM-8 and H-SCM through backboard of H-SRU. - +24V DC is provided through this communication port from backboard of H-SRU. - H-COM-8 acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-COM-8 is assigned automatically using the acquired ID information. 2.1.7.5 Alarms Table 2-18 POD-H-COM-8 - Alarms Alarm Name Description Remedy Alarm Severity LED color High Temperature  Temperature too high Check environment Major Red Temperature high Minor Yellow Low Temperature Temperature too low Minor Yellow Link Communication fail Check pin of communication port/ assigned IP address Major Yellow Downlink ALC Activation ALC activation Check H-COM-8 downlink input level/ attenuator configuration Warning Yellow
           User Manual for POD Systems                                                     Revision: 0.9    43  2.1.8 POD-H-DTM-8x8  Figure 2-30 POD-H-COM-8 2.1.8.1 Functions and features - Receives downlink signals from up to 8 H-COM. After then, it combines and distributes them to up to 8 H-HOM. - Receives uplink signals from up to 8 H-HOM. After then, it combines and distributes them to up to 8 H-COM. - Combines or distributes VHF, UHF signals  - To minimize negative effects by unused input/output ports such as the degradation of VSWR or isolation between ports, the unused ports can be switched into 50 ohm termination by user -  Support Monitoring Port(DL path/UL Path) - When any one sector or DAS system needs low power RU less than 4, H-COM can be connected to H-HOM-L directly without H-DTM.  In this case, the attenuator in the common path of H-COM should add 15dB attenuation using web based GUI to compensate the loss of H-DTM. 2.1.8.2 Specifications - Frequency range: VHF, UHF, 600~2700MHz - Maximum RF Power: -25dBm@DL, -15dBm@UL - Size, weight, and power consumption : refer to Table 2-1 2.1.8.3 RF port and LED  Figure 2-31 POD-H-DTM-8x8 RF port and LED  RF Port - DL IN #1 ~ #8  Receives downlink signal from H-COM, H-STM or H-OIM.  Connected to DL output port of H-COM, H-STM or H-OIM  Connector Type: SMB-L Female - DL OUT #1 ~ #8  Combines inputted downlink signals from DL IN #1 to DL IN #8 and outputs to H-HOM DTM-8x8PWRALMKMWVHFUHF#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8DLMONDL ULVHFUHF#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8ULMONIN OUT IN OUTPWRALMVHFUHF#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8DLMONDL ULVHFUHF#1#2#3#4#5#6#7#8#1#2#3#4#5#6#7#8ULMONIN OUT IN OUT
           User Manual for POD Systems                                                     Revision: 0.9    44   Connected to DL input port of H-HOM  Connector Type: SMB-L Female - UL IN #1 ~ #8  Receives uplink signal from up to 8 H-HOM  Connected to UL output port of H-HOM  Connector Type: SMB-L Female - UL OUT #1 ~ #8  Combines inputted uplink signals from UL IN #1 to UL IN #8 and outputs to H-COM, H-STM or H-OIM  Connected to UL input port of H-COM, H-STM or H-OIM  Connector Type: SMB-L Female  LED Table 2-19 POD-H-DTM-8x8 LED Operation  Specifications PWR Solid Green When power is on. Off When power is off. ALM Off When POD-H-DTM-8x8 has no alarms. Solid Yellow When POD-H-DTM-8x8 has minor alarm. Solid Red When POD-H-DTM-8x8 has major alarm. DL IN #1 ~ #8 Blink Green At the cable connection guide, green led blinks to indicate which RF ports should be connected to. DL OUT #1 ~ #8 Blink Green UL IN #1 ~ #8 Blink Green UL OUT #1 ~ #8 Blink Green 2.1.8.4 Communication port  Figure 2-32  Communication Port - This port provides communication path between H-DTM-8x8 and H-SCM through backboard of H-SRU. - +24V DC is provided through this communication port from backboard of H-SRU. - H-DTM-8x8 acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-DTM-8x8 is assigned automatically using the acquired ID information. 2.1.8.5 Alarms Table 2-20 POD-H-DTM-8x8 - Alarms Alarm Name Description Remedy Alarm Severity LED color High Temperature  Temperature too high Check environment Major Red Temperature high Minor Yellow Low Temperature Temperature too low Minor Yellow Link Communication fail Check pin of communication port/ assigned IP address Major Yellow Downlink ALC Activation ALC activation Check H-DTM downlink input level/ attenuator configuration Warning Yellow
           User Manual for POD Systems                                                     Revision: 0.9    45  2.1.9 POD-H-HOM-L   Figure 2-33 POD-H-HOM-L 2.1.9.1 Functions and features - Converts Downlink RF signal into optical signal and transfers to low power Remote Unit with less than 1W. - Converts Uplink optic signal received from low power Remote Unit to RF signal and transfers to H-COM, H-STM, or H-DTM. - Compensates optic loss between HOM-L and low power Remote unit. - For 2.6G TDD operation, TDD synchronization signal received from H-FEM-B is transferred to low power Remote unit via H-HOM-L. - Communicates with low power Remote unit by PLC modem. 2.1.9.2 Specifications - Frequency range: VHF, UHF, 600~2700MHz - Maximum RF Power: -9dBm@DL, 0dBm@UL - Size, weight, and power consumption : refer to Table 2-1 2.1.9.3 RF port and LED    Figure 2-34 POD-H-HOM-L RF port and LED  RF Port - DL IN  Receives downlink signal from H-COM, H-STM or H-DTM.  Connected to DL output port of H-COM, H-STM or H- DTM.  Connector Type: SMB-L Female - UL OUT  Outputs uplink signal to H-COM, H-STM or H-DTM  Connected to UL input port of H-COM, H-STM or H-DTM  Connector Type: SMB-L Female - T-SYNC IN  Receives TDD synchronization signal from H-FEM-B.  Connected to T-SYNC of H-FEM-B.  Connector Type: SMB-L Female  LED Table 2-21 POD-H-HOM-L LED Operation  Specifications PWR Solid Green When power is on. Off When power is off. ALM Off When POD-H-HOM-L has no alarms. Solid Yellow When POD-H-HOM-L has minor alarm. Solid Red When POD-H-HOM-L has major alarm. HOM-LPWRALMUL OutDL InT_SyncULULULULKMW# 1# 2# 3# 4DLDLDLDLPWRALMUL OutDL InT_SyncULULULULDLDLDLDL
           User Manual for POD Systems                                                     Revision: 0.9    46  UL #1 ~ #4 Off When PD fails. Solid Yellow When PD is Normal. DL IN Blink Green At the cable connection guide, green led blinks to indicate which RF ports should be connected to. UL OUT Blink Green T_Sync  Blink Green 2.1.9.4 Optic port  Figure 2-35  optic port  LD #1 ~ #4 - Each optic port is connected to one low power Remote Unit. - Transfers downlink optic signal to low power Remote Unit. - Connector Type: LC APC Female  PD #1 ~ #4 - Each optic port is connected to low power Remote Unit. - Receives Uplink optic signal from low power Remote Unit. - Connector Type: LC APC Female 2.1.9.5 Communication port  Figure 2-36  Communication Port - This port provides communication path between H-HOM-L and H-SCM through backboard of H-SRU. - +24V DC is provided through this communication port from backboard of H-SRU. - H-HOM-L acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-HOM-L is assigned automatically using the acquired ID information. 2.1.9.6 Alarms Table 2-22 POD-H-HOM-L - Alarms Alarm Name Description Remedy Alarm Severity LED color High Temperature  Temperature too high Check environment Major Red Temperature high Minor Yellow Low Temperature Temperature too low Minor Yellow Link Communication fail Check pin of communication port/ assigned IP address Major Yellow DL Optic Fail Downlink LD fail Check if optic LD fail alarm occurs again after reset. Major Yellow UL Optic Fail Uplink PD fail Check optic cable connection with RU Major Yellow UL Optic Loss Exceed permitted optic loss Check optic cable connection with RU / clean Optic connector and port Minor Yellow # 1# 2# 3# 4
           User Manual for POD Systems                                                     Revision: 0.9    47  Alarm Name Description Remedy Alarm Severity LED color RU Comm. Fail RU Communication Fail Check optic cable connection Minor Yellow
           User Manual for POD Systems                                                     Revision: 0.9    48  2.1.10 POD-H-HOM-H   Figure 2-37 POD-H-HOM-H 2.1.10.1 Functions and features - Converts Downlink RF signal into optical signal and transfers to high power Remote Unit with more than 20W. - Converts Uplink optic signal received from high power Remote Unit to RF signal and transfers to H-COM, H-STM, or H-DTM. - Compensates optic loss between HOM-L and high power Remote unit. - For 2.6G TDD operation, TDD synchronization signal received from H-FEM-B is transferred to high power Remote unit via H-HOM-L. - Communicates with high power Remote unit by PLC modem. 2.1.10.2 Specifications - Frequency range: VHF, UHF, 600~2700MHz - Maximum RF Power: -9dBm@DL, 0dBm@UL - Size, weight, and power consumption : refer to Table 2-1 2.1.10.3 RF port and LED  Figure 2-38 POD-H-HOM-H RF port and LED  RF Port - DL 1/DL 2  Receives downlink signal from H-COM, H-STM or H-DTM.  Connected to DL output port of H-COM, H-STM or H- DTM.  Connector Type: SMB-L Female - UL 1/UL 2  Outputs uplink signal to H-COM, H-STM or H-DTM  Connected to UL input port of H-COM, H-STM or H-DTM  Connector Type: SMB-L Female - T-SYNC IN  Receives TDD synchronization signal from H-FEM-B.  Connected to T-SYNC of H-FEM-B.  Connector Type: SMB-L Female  LED HOM-HPWRALMKMWUL1 UL2DL1 DL2T_SyncDL/UL#1PWRALMUL1 UL2DL1 DL2T_SyncDL/UL
           User Manual for POD Systems                                                     Revision: 0.9    49  Table 2-23 POD-H-HOM-L LED Operation  Specifications PWR Solid Green When power is on. Off When power is off. ALM Off When POD-H-HOM-H has no alarms. Solid Yellow When POD-H-HOM-H has minor alarm. Solid Red When POD-H-HOM-H has major alarm.  DL/UL Off When PD fails. Solid Yellow When PD is Normal. DL 1/DL 2 Blink Green At the cable connection guide, green led blinks to indicate which RF ports should be connected to. UL 1/UL 2 Blink Green T_Sync  Blink Green 2.1.10.4 Optic port  Figure 2-39  optic port  LD - Connected to high power Remote Unit. - Transfers downlink optic signal to high power Remote Unit. - Connector Type: LC APC Female  PD - Connected to high power Remote Unit. - Receives Uplink optic signal from high power Remote Unit. - Connector Type: LC APC Female 2.1.10.5 Communication port  Figure 2-40  Communication Port - This port provides communication path between H-HOM-H and H-SCM through backboard of H-SRU. - +24V DC is provided through this communication port from backboard of H-SRU. - H-HOM-H acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-HOM-H is assigned automatically using the acquired ID information. 2.1.10.6 Alarms Table 2-24 POD-H-HOM-H - Alarms Alarm Name Description Remedy Alarm Severity LED color High Temperature  Temperature too high Check environment Major Red Temperature high Minor Yellow Low Temperature Temperature too low Minor Yellow #1
           User Manual for POD Systems                                                     Revision: 0.9    50  Link Communication fail Check pin of communication port/ assigned IP address Major Yellow DL Optic Fail Downlink LD fail Check if optic LD fail alarm occurs again after reset. Major Yellow UL Optic Fail Uplink PD fail Check optic cable connection with RU Major Yellow UL Optic Loss Exceed permitted optic loss Check optic cable connection with RU / clean Optic connector and port Minor Yellow RU Comm. Fail RU Communication Fail Check optic cable connection Minor Yellow

Navigation menu