Contents
- 1. POD User Manual_v0.9_Revised_Part1
- 2. POD User Manual_v0.9_Revised_Part2
POD User Manual_v0.9_Revised_Part1
USER MANUAL FOR POD SYSTEM ( Version 0.9) Document No.: MUN0630-2015 Date: November 31, 2016 User Manual for POD Systems Revision: 0.9 Revision History Version 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Author KMW KMW KMW KMW KMW KMW KMW KMW KMW Descriptions Date Initial Release Update FCC Regulation Statement Update RF specification on 2.2 and 5 Update FCC RF Exposure information Make typo correct Change the RF Radiation Exposure Update RF Exposure statement and HAAT information Update AWS band Update SAFETY AND REGUALTION WARNING NOTICE 5/14/2015 12/23/2015 1/12/2016 1/15/2016 1/18/2016 2/4/2016 2/24/2016 10/31/2016 11/1/2016 Change List Version Change list Contents User Manual for POD Systems Revision: 0.9 List for Acronyms AGC ALC BDA BOM BTS DAS DL Downlink HEU IF LNA LTE MS NMS PA PSU RF RU UL Uplink Uptime VSWR Automatic Gain Control Automatic Level Control Bi-Directional Amplifier Bill of Material Base Transceiver Station Distributed Antenna System Downlink Path covered from the Base Transceiver Station (BTS) to the subscribers’ service area via the repeater Head-end Unit Intermediate Frequency Low Noise Amplifier Long Term Evolution Mobile Station Network Management System Power Amplifier Power Supply Unit Radio Frequency Remote Unit Uplink Path covered from the subscribers’ service area to the Base Transceiver Station (BTS) via the repeater Time during which a Unit or Module is in operation Voltage Standing Wave Ratio User Manual for POD Systems Revision: 0.9 Table of Contents 1. POD System Overview ......................................................................................................................................14 1.1 Features of POD System ............................................................................................................................14 1.2 POD System Architecture ..........................................................................................................................15 1.3 POD System Configuration ........................................................................................................................17 1.3.1 SISO Configuration..............................................................................................................................17 1.3.2 MIMO Configuration ..........................................................................................................................18 1.4 2. POD System Scalability & Limitation ..........................................................................................................19 POD system Components .................................................................................................................................21 2.1 Head-end Unit............................................................................................................................................21 2.1.1 POD-H-DMCU (DAS Main Control Unit)..............................................................................................23 2.1.1.1 Functions and features .............................................................................................................23 2.1.1.2 Specifications ............................................................................................................................23 2.1.1.3 LED, LCD & Key PAD, Reset .......................................................................................................23 2.1.1.4 Ethernet Ports ...........................................................................................................................24 2.1.1.5 DC power input port & power switch .......................................................................................24 2.1.1.6 External Alarm Port ..................................................................................................................24 2.1.1.7 Ground port ..............................................................................................................................25 2.1.1.8 Alarms .......................................................................................................................................25 2.1.2 POD-H-SRU .........................................................................................................................................26 2.1.2.1 Functions and features .............................................................................................................26 2.1.2.2 Specifications ............................................................................................................................26 2.1.2.3 DC input port & Fuse ................................................................................................................26 2.1.2.4 FAN port....................................................................................................................................27 2.1.2.5 Ground port ..............................................................................................................................27 2.1.3 POD-H-SCM ........................................................................................................................................28 2.1.3.1 Functions and features .............................................................................................................28 2.1.3.2 Specifications ............................................................................................................................28 2.1.3.3 LED, LCD & Key PAD, Reset .......................................................................................................28 2.1.3.4 Ethernet Port ............................................................................................................................29 2.1.3.5 Communication port .................................................................................................................29 2.1.3.6 Alarms .......................................................................................................................................29 2.1.4 POD-H-MCM .......................................................................................................................................30 2.1.4.1 Functions and features .............................................................................................................30 2.1.4.2 Specifications ............................................................................................................................30 2.1.4.3 LED, LCD & Key PAD, Reset .......................................................................................................30 2.1.4.4 Ethernet Ports ...........................................................................................................................31 User Manual for POD Systems Revision: 0.9 2.1.4.5 External Alarm Ports .................................................................................................................32 2.1.4.6 Communication port .................................................................................................................32 2.1.4.7 Alarms .......................................................................................................................................32 2.1.5 POD-H-FEM-L-x ...................................................................................................................................33 2.1.5.1 Functions and features .............................................................................................................34 2.1.5.2 Specifications ............................................................................................................................34 2.1.5.3 RF Port and LED ........................................................................................................................35 2.1.5.4 Communication port .................................................................................................................36 2.1.5.5 Alarms .......................................................................................................................................36 2.1.6 POD-H-FEM-H-x ..................................................................................................................................37 2.1.6.1 Functions and features .............................................................................................................38 2.1.6.2 Specifications ............................................................................................................................38 2.1.6.3 RF port and LED ........................................................................................................................39 2.1.6.4 Communication port .................................................................................................................40 2.1.6.5 Alarms .......................................................................................................................................40 2.1.7 POD-H-COM-8 ....................................................................................................................................41 2.1.7.1 Functions and features .............................................................................................................41 2.1.7.2 Specifications ............................................................................................................................41 2.1.7.3 RF port and LED ........................................................................................................................41 2.1.7.4 Communication port .................................................................................................................42 2.1.7.5 Alarms .......................................................................................................................................42 2.1.8 POD-H-DTM-8x8 .................................................................................................................................43 2.1.8.1 Functions and features .............................................................................................................43 2.1.8.2 Specifications ............................................................................................................................43 2.1.8.3 RF port and LED ........................................................................................................................43 2.1.8.4 Communication port .................................................................................................................44 2.1.8.5 Alarms .......................................................................................................................................44 2.1.9 POD-H-HOM-L ....................................................................................................................................45 2.1.9.1 Functions and features .............................................................................................................45 2.1.9.2 Specifications ............................................................................................................................45 2.1.9.3 RF port and LED ........................................................................................................................45 2.1.9.4 Optic port ..................................................................................................................................46 2.1.9.5 Communication port .................................................................................................................46 2.1.9.6 Alarms .......................................................................................................................................46 2.1.10 POD-H-HOM-H ....................................................................................................................................48 2.1.10.1 Functions and features ............................................................................................................48 2.1.10.2 Specifications ..........................................................................................................................48 User Manual for POD Systems Revision: 0.9 2.1.10.3 RF port and LED .......................................................................................................................48 2.1.10.4 Optic port ................................................................................................................................49 2.1.10.5 Communication port ...............................................................................................................49 2.1.10.6 Alarms .....................................................................................................................................49 2.1.11 POD-H-STM-8x4 ..................................................................................................................................51 2.1.11.1 Functions and features ............................................................................................................51 2.1.11.2 Specifications ..........................................................................................................................51 2.1.11.3 RF port and LED .......................................................................................................................52 2.1.11.4 Communication port ...............................................................................................................53 2.1.11.5 Alarms .....................................................................................................................................53 2.1.12 POD-H-PSU-x ......................................................................................................................................54 2.1.12.1 Functions and features ............................................................................................................54 2.1.12.2 Specifications ..........................................................................................................................54 2.1.12.3 LED ..........................................................................................................................................54 2.1.12.4 Ethernet Port ...........................................................................................................................54 2.1.12.5 AC input on/off Switch & DC output on/off switch .................................................................54 2.1.12.6 AC input port & DC output port ..............................................................................................55 2.1.12.7 Rack ID.....................................................................................................................................55 2.1.12.8 Ground port ............................................................................................................................56 2.1.12.9 Alarms .....................................................................................................................................56 2.1.13 POD-H-CDU .........................................................................................................................................57 2.1.13.1 Functions and features ............................................................................................................57 2.1.14 POD-H-FAU .........................................................................................................................................57 2.2 2.1.14.1 Functions and features ............................................................................................................57 2.1.14.2 The rules for installing FAN unit ..............................................................................................57 2.1.14.3 Port ..........................................................................................................................................57 2.1.14.4 Alarms .....................................................................................................................................58 Remote Unit ...............................................................................................................................................59 2.2.1 7/5/3 band RU for commercial band service (POD-R-7S8CPAWB-2730-AC/DC)................................59 2.2.1.1 Functions and features .............................................................................................................59 2.2.1.2 Specifications ............................................................................................................................59 2.2.1.3 RF ports and LED .......................................................................................................................62 2.2.1.4 Debug Window .........................................................................................................................63 2.2.1.5 Alarms .......................................................................................................................................65 2.2.1.6 Grounding .................................................................................................................................65 2.2.2 PS700/800 RU for public safety 700/800 frequency band service (POD-R-P78-27-AC/DC) ...............66 2.2.2.1 Functions and features .............................................................................................................66 User Manual for POD Systems 3. Revision: 0.9 2.2.2.2 Specifications ............................................................................................................................66 2.2.2.3 RF ports and LED .......................................................................................................................67 2.2.2.4 Debug Window .........................................................................................................................68 2.2.2.5 Battery Backup Port ..................................................................................................................69 2.2.2.6 Alarms .......................................................................................................................................70 2.2.2.7 Grounding .................................................................................................................................71 Equipment Installation ......................................................................................................................................72 3.1 Inspection before equipment installation .................................................................................................72 3.1.1 The Part list for each unit ...................................................................................................................72 3.2 3.1.1.1 Head-end Unit ..........................................................................................................................72 3.1.1.2 Remote Unit ..............................................................................................................................73 Head-end Unit Equipment Installation ......................................................................................................74 3.2.1 Installation Head-end Unit in a 19” rack ............................................................................................74 3.2.1.1 The sequence for mounting head-end unit ..............................................................................75 3.2.2 Grounding ...........................................................................................................................................76 3.2.3 Optic port Cleaning .............................................................................................................................76 3.3 Remote Unit ...............................................................................................................................................77 3.3.1 Wall Mount for 3/5/7 band RU and PS700/800 RU............................................................................77 3.3.2 Grounding ...........................................................................................................................................78 3.3.2.1 4. 3/5/7 band RU, PS700/800 RU .................................................................................................78 Cable Connection ..............................................................................................................................................79 4.1 Head-end Unit Cable Connection ..............................................................................................................79 4.1.1 Cable ...................................................................................................................................................79 4.1.2 Cable Connection Example for frequency bands with FDD type ........................................................80 4.1.3 Cable Connection for TDD 2.6G frequency band................................................................................82 4.1.4 Cable Connection Example for Public Safety 700/800 band ..............................................................84 4.1.5 Cable Connection Example for MIMO configuration .........................................................................85 4.1.6 Cable connection between multiple Racks ........................................................................................87 4.2 Remote Unit Cable Connection .................................................................................................................88 4.2.1 7/5/3 band & PS700/800 RU ..............................................................................................................88 5. 4.2.1.1 Cable .........................................................................................................................................88 4.2.1.2 Optic cable connection .............................................................................................................89 4.2.1.3 AC or DC power cable connection ............................................................................................90 4.2.1.4 Ethernet cable connection for connecting with Expansion RU ................................................91 Specification ......................................................................................................................................................92 5.1 Electrical Specifications (Low power HFM – Low power RU) ....................................................................92 5.2 Additional Model Names ...........................................................................................................................94 User Manual for POD Systems Revision: 0.9 Figures Figure 1-1 Figure 1-2 Figure 1-3 Figure 1-4 Figure 1-5 Figure 2-1 Figure 2-2 Figure 2-3 Figure 2-4 Figure 2-5 Figure 2-6 Figure 2-7 Figure 2-8 Figure 2-9 Figure 2-10 Figure 2-11 Figure 2-12 Figure 2-13 Figure 2-14 Figure 2-15 Figure 2-16 Figure 2-17 Figure 2-18 Figure 2-19 Figure 2-20 Figure 2-21 Figure 2-22 Figure 2-23 Figure 2-24 Figure 2-25 Figure 2-26 Figure 2-27 Figure 2-28 Figure 2-29 Figure 2-30 Figure 2-31 Figure 2-32 Figure 2-33 Figure 2-34 Figure 2-35 Figure 2-36 Figure 2-37 Figure 2-38 Figure 2-39 Figure 2-40 Figure 2-41 Figure 2-42 DAS Overall Block Diagram .................................................................................................................15 How it works .......................................................................................................................................16 SISO Configuration ..............................................................................................................................17 MIMO Configuration ...........................................................................................................................18 POD System Scalability .......................................................................................................................19 Head-end Unit Front View ..................................................................................................................21 Head-end Unit Rear View ...................................................................................................................21 POD-H-DMCU .....................................................................................................................................23 LED, LCD & Key PAD, Reset .................................................................................................................23 Ethernet Ports.....................................................................................................................................24 DC power input port & power switch .................................................................................................24 External Alarm Ports ...........................................................................................................................25 POD-H-SRU Front View .......................................................................................................................26 POD-H-SRU Rear View ........................................................................................................................26 DC input port & Fuse ..........................................................................................................................27 FAN port .............................................................................................................................................27 POD-H-SCM .........................................................................................................................................28 LED, LCD & Key PAD ............................................................................................................................28 Ethernet Port ......................................................................................................................................29 Communication Port...........................................................................................................................29 POD-H-MCM .......................................................................................................................................30 LED, LCD & Key PAD, Reset .................................................................................................................31 Ethernet ports.....................................................................................................................................31 External Alarm Ports ...........................................................................................................................32 Communication Port...........................................................................................................................32 POD-H-FEM-L-x Front & Rear View.....................................................................................................33 POD-H-FEM-L-x RF port and LED ........................................................................................................35 Communication Port...........................................................................................................................36 POD-H-FEM-H-x Front & Rear View ....................................................................................................37 POD-H-FEM-H-x RF port and LED........................................................................................................39 Communication Port...........................................................................................................................40 POD-H-COM-8.....................................................................................................................................41 POD-H-COM-8 RF port and LED ..........................................................................................................41 Communication Port...........................................................................................................................42 POD-H-COM-8.....................................................................................................................................43 POD-H-DTM-8x8 RF port and LED .......................................................................................................43 Communication Port...........................................................................................................................44 POD-H-HOM-L.....................................................................................................................................45 POD-H-HOM-L RF port and LED ..........................................................................................................45 optic port ............................................................................................................................................46 Communication Port...........................................................................................................................46 POD-H-HOM-H ....................................................................................................................................48 POD-H-HOM-H RF port and LED .........................................................................................................48 optic port ............................................................................................................................................49 Communication Port...........................................................................................................................49 POD-H-STM-8x4-DL ............................................................................................................................51 POD-H-STM-8x4-UL ............................................................................................................................51 User Manual for POD Systems Revision: 0.9 Figure 2-43 POD-H-STM-8x4-DL RF port and LED ..................................................................................................52 Figure 2-44 POD-H-STM-8x4-UL RF port and LED ..................................................................................................52 Figure 2-45 Communication Port...........................................................................................................................53 Figure 2-46 POD-H-PSU-x.......................................................................................................................................54 Figure 2-47 POD-H-PSU-x LED ................................................................................................................................54 Figure 2-48 Ethernet Port ......................................................................................................................................54 Figure 2-49 AC input on/off Switch & DC output on/off switch ..................................................................................55 Figure 2-50 AC input port & DC output port ..........................................................................................................55 Figure 2-51 Rack ID ................................................................................................................................................55 Figure 2-52 POD-H-CDU .........................................................................................................................................57 Figure 2-53 POD-H-FAU .........................................................................................................................................57 Figure 2-54 Remote Unit – 7/5/3 band..................................................................................................................59 Figure 2-55 Remote Unit External Interfaces ........................................................................................................62 Figure 2-56 Debug Window ...................................................................................................................................63 Figure 2-57 Port name for each RU type ...............................................................................................................64 Figure 2-58 Remote Unit – PS700/800 ..................................................................................................................66 Figure 2-59 Remote Unit - PS700/800 External Interfaces ....................................................................................67 Figure 2-60 Debug Window ...................................................................................................................................68 Figure 2-61 Port name for each RU type ...............................................................................................................69 Figure 2-62 Battery backup port ............................................................................................................................70 Figure 3-1 Head-end Unit Rack Mount (Front & Rear view) ................................................................................74 Figure 3-2 Head-end Unit - Rack Mount Sequence .............................................................................................75 Figure 3-3 Optic Connector Cleaning (left) and Optic Port Cleaning (right) ........................................................76 Figure 3-4 LC/APC Optic Connector Dust Cap ......................................................................................................76 Figure 3-5 3/5/7 band RU, PS700/800 RU – wall mount bracket ........................................................................77 Figure 3-6 3/5/7 band RU, PS700/800 RU – Install RU into wall mount bracket .................................................77 Figure 3-7 3/5/7 band RU, PS700/800 RU – RU installed on the wall .................................................................78 Figure 3-8 3/5/7 band RU grounding ...................................................................................................................78 Figure 4-1 Head-end - cables ...............................................................................................................................79 Figure 4-2 Cable Connection Example for frequency bands with FDD type ........................................................80 Figure 4-3 Cable Connection Example #1 for TDD 2.6G frequency band ............................................................82 Figure 4-4 Cable Connection Example for Public Safety 700/800 band ..............................................................84 Figure 4-5 Cable Connection for FDD frequency band (MIMO) support .............................................................85 Figure 4-6 Connection Diagram for Rack Inter Connection .................................................................................87 User Manual for POD Systems Revision: 0.9 Tables Table 1-1 Table 2-1 Table 2-2 Table 2-3 Table 2-4 Table 2-5 Table 2-6 Table 2-7 Table 2-8 Table 2-9 Table 2-10 Table 2-11 Table 2-12 Table 2-13 Table 2-14 Table 2-15 Table 2-16 Table 2-17 Table 2-18 Table 2-19 Table 2-20 Table 2-21 Table 2-22 Table 2-23 Table 2-24 Table 2-25 Table 2-26 Table 2-27 Table 2-28 Table 2-29 Table 2-30 Table 2-31 Table 2-32 Table 2-33 Table 2-34 Table 2-35 Table 2-36 Table 2-37 Table 2-38 Table 2-39 Table 5-1 Table 5-2 Table 5-3 Table 5-4 POD System Scalability & Limitations .................................................................................................20 Size, weight, and power consumption (Head-end Unit) .....................................................................22 POD-H-DMCU LED Operation .............................................................................................................23 Pin map - External Alarm Port ............................................................................................................25 POD-H-DMCU - Alarms .......................................................................................................................25 POD-H-SCM LED Operation ................................................................................................................28 POD-H-SCM - Alarms ..........................................................................................................................29 POD-H-MCM LED Operation ...............................................................................................................31 POD-H-MCM - Alarms .........................................................................................................................32 POD-H-FEM-L-x frequency range ........................................................................................................34 POD-H-FEM-L-x Size, weight, and power consumption ......................................................................34 POD-H-FEM-L-x LED Operation ...........................................................................................................36 POD-H-FEM-L-x - Alarms .....................................................................................................................36 POD-H-FEM-H-x frequency range .......................................................................................................38 POD-H-FEM-H-x Size, weight, and power consumption .....................................................................38 POD-H-FEM-H-x LED Operation ..........................................................................................................40 POD-H-FEM-H-x - Alarms ....................................................................................................................40 POD-H-COM-8 LED Operation ............................................................................................................42 POD-H-COM-8 - Alarms ......................................................................................................................42 POD-H-DTM-8x8 LED Operation .........................................................................................................44 POD-H-DTM-8x8 - Alarms ...................................................................................................................44 POD-H-HOM-L LED Operation ............................................................................................................45 POD-H-HOM-L - Alarms ......................................................................................................................46 POD-H-HOM-L LED Operation ............................................................................................................49 POD-H-HOM-H - Alarms......................................................................................................................49 POD-H-STM-8x4 LED Operation..........................................................................................................53 POD-H-STM-8x8 - Alarms ....................................................................................................................53 POD-H-PSU-x LED Operation ..............................................................................................................54 Rack ID ................................................................................................................................................56 POD-H-PSU - Alarms ...........................................................................................................................56 POD-H-FAU - Alarms ...........................................................................................................................58 3/5/7 band RU - 700M, SMR800 + 850M Specifications ....................................................................60 3/5/7 band RU – PCS, AWS Specifications ..........................................................................................60 3/5/7 band RU – WCS, 2.6G Specifications ........................................................................................61 7/5/3 band RU LED Operation ............................................................................................................62 3/5/7 band RU – Alarms .....................................................................................................................65 PS700/800 RU - Specifications ............................................................................................................67 7/5/3 band RU LED Operation ............................................................................................................68 Pin map - Battery Backup Port ............................................................................................................70 PS700/800 band RU – Alarms .............................................................................................................70 POD DAS 2-Band RU Electrical Specifications (POD-R-P78-27-AC/DC) ...............................................92 POD DAS 7-Band RU Electrical Specifications (POD-R-7S8CPAWB-2730-AC/DC) ...............................93 Basic Model and Additional Models on 2-Band Remote Unit ............................................................94 Basic Model and Additional Models on 7-Band Remote Unit ............................................................94 10 User Manual for POD Systems Revision: 0.9 SAFETY AND REGUALTION WARNING NOTICE Only qualified personnel should handle the POD equipment. Any person involved in installation or operation of the POD should understand and follow these safety guidelines. REGULATION Obey all general and regional installation and safety regulations to prevent any kinds of safety accidents such as potential electric shock, or RF exposure while installation, maintenance, or operation. FCC REGULATION Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor‐only restrictions is prohibited. FCC Part 15.19 Statements FCC Part 15.105 statement The antenna(s) must be installed such that a minimum separation distance of at least 60 cm with 3dBi antenna gain or 300 cm with 11dBi antenna gain or is maintained between the radiator (antenna) and all persons at all times. This device must not be co-located or operating in conjunction with any other antenna or transmitter. FCC part 20 Industrial Booster statement (FCC ID: ZUQR7S8CPAWB-2730 & ZUQR-P78-27) Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. RF Exposure Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Part 15.21 statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. FCC part 90 Industrial Booster statement - THIS IS A 90.219 CLASS B DEVICE (FCC ID: ZUQR-P78-27) WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of FCC Licensee to operate this device. You MUST register Class B signal boosters (as defined in 47 CFR 90.219) online at 11 User Manual for POD Systems Revision: 0.9 www.fcc.gov/signal-boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. FCC part 27.5 / SRSP 518 (FCC ID: ZUQR7S8CPAWB-2730) FCC part 90.635 requirement (FCC ID: ZUQR-P78-27) Antennas must be installed in accordance with FCC 27.50 and SRSP 518. With 11dBi gain antennas the height of the antenna above average terrain (HAAT) must not exceed 4777m for IC. For different gain antennas refer to the relevant rules. Antennas must be installed in accordance with FCC 90.635. With 11dBi gain antennas the height of the antenna above average terrain (HAAT) is permitted over 1372m. For different gain antennas refer to the relevant rules. Fixed stations operating in the 1710-1755 MHz band are limited to a maximum antenna height of 10 meters above ground. IC REGULATION RSS-131 Section 5.3 – (The input and output impedances) RSS-GEN, Sec. 7.1.2 – (transmitters) The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionneravec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention desautres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotroperayonnée quivalente (p.i.r.e.) ne dépassepas l’intensité nécessaire à l’établissement d’une communication satisfaisante. RSS-GEN, Sec. 7.1.2 – (detachable antennas) This radio transmitter (identify the device by certification number, or model number if Category II)has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s’il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste,ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur. 12 User Manual for POD Systems Revision: 0.9 RF Radiation Exposure This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 60 cm with 3dBi antenna gain or 300 cm with 11dBi antenna gain between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF exposure will be addressed at time of installation and the use of higher gain antennas require larger separation distances. L’antenne (ou les antennes) doit être installée de façon à maintenir à tout instant une distance minimum de au moins 60 cm avec le gain d'antenne 3dBi ou 300 cm avec 11dBi gain d'antenne entre la source de radiation (l’antenne) et toute personne physique. Cet appareil ne doit pas être installé ou utilisé en conjonction avec une autre antenne ou émetteur. ELECTRIC SHOCK The POD System uses the AC or DC power with high voltage level which could result in electric shock and may cause severe injury. LASER SAFETY To avoid eye injury, do not look directly into the optical ports, patch cords or optical cables. Always assume that optical output is on. To avoid the potential of radiation exposure, do not leave optic connectors uncovered when not connected. To check fiber cable connection, use an optical power meter and this should be performed by only technicians familiar with fiber optic safety practices and procedures. This equipment uses a Class 1 LASER according to FDA/CDRH Rules. This product conforms to all applicable standards of 21 CFR Chapter 1, Subchapter J, Part 1040 SAFETY The POD system should not be modified or used for any other purposes without authority’s permission in any cases. This could cause fires, electric shock or other injuries. Be careful not to touch the heat sink part to prevent any degree of burns from high temperature of the heat sink. Do not place the DAS equipments close to flammable materials which could reach high temperatures due to heat dissipation of the DAS equipments. While working with outdoor DAS equipment with door, make sure to securely fasten the door to prevent any kinds of damages from slamming shut due to abrupt wind. UL REGULATION This equipment complies with UL Standard for safety. 13 User Manual for POD Systems 1. Revision: 0.9 POD SYSTEM OVERVIEW POD System is a compact and flexible platform which is designed to provide effective service coverage for various indoor and outdoor applications. POD system supports multiple wireless standards currently being used such as CDMA/EVDO, WCDMA and LTE, as well as high traffic capacity and flexible distribution by sectorization and various flexibilities for future expansions. POD system supports effectively DAS Network Management system by using Ethernet communications connected to between Head-end Unit and Remote Unit. 1.1 Features of POD System A unified platform ALL IP structure All modules installed in H-SRU support hot swap function, so all the modules can be replaced without powering down H-SRU. Documentation Ethernet port forward function Input/output ports for external alarm monitoring Hot Swap Downlink spectrum monitoring which is built in H-FEM SNMP/Remote monitoring & control Uptime Save log @H-DMCU, save alarm history @each module Monitoring interface for other equipments connected to DAS Auto system commissioning DAS tree/Inter-connection diagram/rack diagram System configuration backup/restore Monitoring functions for DAS system Web based GUI interface at head-end unit and Remote Unit. Firmware download for all connected active modules at remote site and right at the head-end Sectorization/commissioning at remote site and right at the head-end Easy installation, commissioning and optimization A DMCU supports up to 4 racks. (a rack can support up to 7 H-SRUs) A DMCU supports up to 4 H-OIMs and 6 H-OEMs. The User-friendly Web based GUI All modules and units have its unique IP address which is assigned automatically when installed. Supported capacity per a DMCU A single head-end unit supports low & high power RU, indoor & outdoor RU. A single head-end supports all commercial frequencies bands from 700M to 2.6G and public safety frequencies bands including UHF/VHF, PS700 and PS800. Auto BOM Generation System Information Generation Provide external memory for saving documents such as closeout package, user manual SMB-L connector (SMB with lock) SMB-L connector makes RF cable connections between RF ports easier, comparing to SMA connector. 14 User Manual for POD Systems The cable with SMB-L connector provides more stable tight connection because SMB-L connector has lock function, comparing to SMB connector. The cable with SMB connector might be untied or loosened easily by vibration or unintentional cable pulling. The RF cable with SMB connector can be used instead of the RF cable with SMB-L connector because SMBL connector has compatibility with SMB connector. 1.2 Revision: 0.9 POD System Architecture Figure 1-1 represents the overall DAS block diagram of KMW DAS system, POD. POD consists of HEU (head-end Unit), and RU (Remote unit). HEU provides the interface between plurality of BTS and plurality of RUs, and RUs are deployed over multiple shadow regions to provide wireless service coverage to mobile users in shadow regions. Remote Sites Building #1 Building #2 MDF IDF #1 Remote Site #1 Optic Head-end OEM-B Remote eNB OEM-S Optic(RF) Optic RU COAX OIM-B OIM-S COM-8 DTM 8x8 OPTIC HOM IDF #2 CPRI Optic(CPRI) FEM eNB Remote Site #2 RF RU Optic IDF #1 FEM HOM RU Air Interface eNB BDA RF FEM COM-8 IDF #3 DTM 8x8 Optic eNB RF FEM IDF #2 IDF #4 HOM eNB Remote Site #3 RF FEM Optic STM 8x4 Air Interface eNB BDA RF RU RU DTM 8x8 RU IDF #3 FEM RU MDF: Main Distribution Frame IDF: Intermediate Distribution Frame Figure 1-1 DAS Overall Block Diagram Figure 1-1 shows general signal flow and module composition of POD DAS system. POD DAS System supports various methods to connect with BTS such as direct connection to BTS through RF coaxial cable, connection to BTS via antenna through BDA, and connection to BTS by CPRI digital interface over optic. If user wants air interface with BTS, it is necessary for user to select proper BDA product separately because POD DAS system does not include any kinds of BDA. H-FEM provides the interface between various base station having different frequency band/technology and POD DAS system, and H-COM combines downlink signal received from H-FEM and distributes uplink signals received from DTM to FEM. H-DTM combines downlink signals from H-COM and then distributes to H-HOM, also combines uplink signals from several H-HOM and then distributes to H-COM. H-HOM converts downlink RF signal received from H-DTM to optic signal and then transfers to RU, also converts uplink optic signal received from RU to RF signal and then transfers to H-DTM. RU provides wireless service coverage to users by transmitting downlink signal received from H-HOM through the antenna. Also, it transfers to HOM after converting uplink signal received from mobile stations through the antenna to optic signal. 15 User Manual for POD Systems Donor Antenna Revision: 0.9 BTS Air Interface BUILDING #1 BUILDING #2 Coa Coa Server Antenna Remote Unit Bi-directional Amplifier or Repeater BTS Head-end BDA SCM FEM OIM-S OEM-B DTM DTM HOM HOM OEM-S OEM-S Optic Equipment Room COAX OPTIC CPRI BTS Optic OIM_B OIM-B Figure 1-2 How it works Figure 1-2 is a practical example of POD DAS system. It shows how to distribute various BTS signals from Headend Unit to multiple Remote Units. Especially, in case of buildings away from Head-end location which needs multiple remote units, it is composed by the structure which distributes to multiple remote units after transmitting signal to other building through only one optic line using H-OEM, not transmits the signal by individual optic line according to required the number of remote units. Also, it supports the connection between Head-end and base station through optic line using H-OIM when base station is away from head-end location. 16 User Manual for POD Systems 1.3 POD System Configuration 1.3.1 SISO Configuration Assumption Revision: 0.9 Supported frequency Band: 700M, SMR800, 850M, PCS, AWS, WCS, 2.6G # of RU: 2 System Configuration Module or Unit Q’ty H-DMCU or H-MCM H-PSU or H-PSM H-FEM-L-7 H-FEM-L-S8 H-FEM-L-C H-FEM-L-P H-FEM-L-A H-FEM-L-W H-FEM-L-B H-COM-8 H-HOM-L 7 band RU Comments eNB Main Controller Power Supply Unit 700M SMR800 850M PCS AWS WCS 2.6G Headend RU #1 KMW 700M #2 #3 #4 Group Rack DMCU 12 12 Power Alarm DMCU HPSU SMR800 #5 Run ENT Link Up DMCU Alarm Down HE Alarm 850M #6 #7 #1 #8 #2 #3 KMW KMW Path A DL MON PCS PWR ALM 10 KMW Path A 11 13 15 17 16 18 19 21 20 22 23 25 27 29 24 26 28 30 14 KMW ALM DL Out DL Out DL MON DL Out DL Out UL MON UL MON DL Out UL MON UL MON 32 KMW KMW PWR PWR ALM ALM DL Out UL MON KMW DL MON PWR DL Out ALM DL COM UL COM #1 #1 #2 #2 UL Out #1 UL MON DL #1 UL In UL In UL In UL In UL In AWS UL UL In #2 DL #3 #3 #4 #4 #5 #5 #6 #6 #7 #7 UL #2 T-Sync Run Link ENT Up ALM Reset Down ESC Path B Path B Path B Path B Path B DL MON DL MON DL MON DL MON DL MON #3 #3 Path B DL DL MON UL #4 DMCU DL Out DL Out DL Out UL MON DL Out DL Out UL Mon UL MON UL MON UL In UL MON UL MON DLOut DL Web GUI UL #4 UL MON #8 UL In 2.6G 31 Path A DL MON PWR ALM 12 KMW Path A DL MON PWR ALM KMW PCS DL MON PWR ALM KMW Path A DL MON PWR ALM Web GUI Reset KMW PWR Modem ESC RU Alarm KMW Path A WCS #4 KMW UL In UL In UL In UL In FEM-L-7 FEM-L-S8 FEM-L-C FEM-L-P Figure 1-3 FEM-L-A FEM-L-W #8 T_Sync UL In DL SCM DL In FEM-L-B BLANK UL COM-8 BLANK HOM-L SISO Configuration 17 User Manual for POD Systems 1.3.2 MIMO Configuration Assumption Revision: 0.9 Supported frequency Band SISO: 700M, SMR800, 850M, PCS, AWS, WCS, 2.6G MIMO: 700M, PCS, AWS, 2.6G # of RU: 2 System Configuration Module or Unit Q’ty H-DMCU or H-MCM H-PSU or H-PSM H-FEM-L-7 H-FEM-L-S8 H-FEM-L-C H-FEM-L-P H-FEM-L-A H-FEM-L-W H-FEM-L-B H-COM-8 H-HOM-L 7 band RU Comments Main Controller Power Supply Unit 700M SMR800 850M PCS AWS WCS 2.6G RU eNB 700M MIMO #1 700M MIMO #2 Headend MIMO #1 #1 KMW 850M PCS MIMO #1 AWS MIMO #1 PCS MIMO #2 AWS MIMO #2 WCS 2.6G MIMO #2 MIMO #2 #4 12 12 Alarm DMCU #5 #6 #7 #1 #8 #2 #3 #4 KMW KMW KMW Run ENT Link Up DMCU Alarm Down HE Alarm ESC RU Alarm Reset KMW Modem 11 13 15 17 19 21 23 25 27 29 Web GUI 10 12 14 16 18 20 22 24 26 28 30 KMW KMW Path A Path A Path A DL MON DL MON DL MON PWR PWR ALM PWR ALM PWR ALM KMW KMW PCS PCS KMW Path A DL MON PWR ALM ALM KMW Path A DL MON PWR PWR ALM KMW Path A DL MON PWR ALM DL Out DL Out DL MON DL MON DL Out DL Out UL MON UL MON DL Out DL Out UL MON UL MON UL In UL In UL In UL In UL In KMW PWR DL Out ALM ALM UL COM DL COM UL COM #1 #1 #1 #2 #2 #2 #2 32 PWR PWR ALM DL COM #1 31 KMW KMW PWR ALM ALM DL Out UL MON UL Out UL Out #1 #1 UL MON #1 DL DL UL UL UL In DL DL #3 #3 #3 #3 #4 #4 #4 #4 UL UL Link ENT Up ALM Reset Down ESC Path B Path B Path B DL MON DL MON DL MON DL Out DL Out DL Out Path B Path B DL MON DL MON DL Out DL Out #3 Path B DL MON #2 #2 #2 T-Sync Run DL DL #5 #5 #5 #5 #6 #6 #6 #6 #3 #3 UL UL #4 #4 DMCU UL MON UL MON DLOut Web GUI #4 UL Mon 2.6G MIMO #1 #3 Group Rack HPSU SMR800 #2 DMCU Power UL In UL MON UL In UL MON UL In UL In UL In UL MON UL In UL MON UL In UL MON FEM-L-7 FEM-L-S8 FEM-L-C FEM-L-P Figure 1-4 FEM-L-P FEM-L-A FEM-L-W DL UL UL #7 #7 #7 #7 DL In DL In #8 #8 #8 #8 T_Sync T_Sync HOM-L HOM-L UL In DL SCM DL FEM-L-B UL COM-8 DL UL COM-8 MIMO Configuration 18 User Manual for POD Systems 1.4 Revision: 0.9 POD System Scalability & Limitation Figure 1-5 shows maximum capacity of POD system composed by one DMCU Rack #1 Rack #2 SD Rack #3 SD Rack #4 SD SD KMW DMCU Run ENT Link Up DMCU Alarm Down HE Alarm ESC RU Alarm Reset Modem 11 13 15 17 19 21 23 25 27 29 31 Web GUI 10 12 14 16 18 20 22 24 26 28 30 32 PSU #1 PSU #2 PSU #3 PSU #4 SRU #01 SRU #08 SRU #15 SRU #21 SRU #02 SRU #09 SRU #16 SRU #22 SRU #03 SRU #10 SRU #17 SRU #23 SRU #04 SRU #11 SRU #18 SRU #24 SRU #05 SRU #12 SRU #19 SRU #25 SRU #06 SRU #13 SRU #20 SRU #26 SRU #07 SRU #14 Figure 1-5 POD System Scalability 19 User Manual for POD Systems Table 1-1 Revision: 0.9 POD System Scalability & Limitations Supported maximum number POD System1) H-FEM 1) 2) 3) 4) 5) 6) 7) 8) 9) /Rack /H-SRU H-DMCU RACK H-PSU 12) H-SRU 26 208 843) 124) H-FEM-L H-FEM-H H-COM-8 26 26 124) H-DTM 8x8 26 26 64) HOM 32 28 45) RU 2566) 2247) 328) H-OIM-B H-OEM-S # of path/Module 29) Table 1-1 shows hardware capacity of one POD system. One H-PSU supports one rack with 7 H-SRU which is fully filled with modules. The number of supported H-FEM/rack = 7 H-SRU x 12 H-FEM/H-SRU = 84 One H-SRU consists of 12 slots. So, it supports up to 12 modules with 1 slot size (H-FEM & H-COM-8) and 6 modules with 2 slot size (H-DTM 8x8). The number of supported HOM/H-SRU is limited up to four (4). The number of supported RU in POD system is limited up to 256. The number of supported RU/rack = 7 SRU/rack x the number of supported RU/SRU = 224 The number of supported RU/H-SRU = 4 HOM/SRU x 4 path/HOM x 2 RU/path = 32 H-FEM-L-P (PCS) supports only one path. 20 User Manual for POD Systems 2. 2.1 Revision: 0.9 POD SYSTEM COMPONENTS Head-end Unit #1 KMW H-PSU #2 #3 #4 Group Rack DMCU 12 12 Power Alarm DMCU HPSU #5 #6 #7 #1 #8 #2 #3 #4 KMW DMCU Run ENT Link Up DMCU Alarm Down HE Alarm ESC RU Alarm KMW Web GUI Reset KMW KMW Path A KMW PS700 DL MON ALM KMW 11 10 12 KMW PCS 14 16 17 19 18 20 KMW 23 22 24 25 27 29 31 26 28 30 32 12 11 10 KMW Path A KMW KMW Path A DL MON DL MON PWR ALM PWR PWR DL Out UL COM DL COM DL Out PWR ALM ALM ALM DL Out 21 PWR ALM DL MON 15 KMW Path A PWR ALM DL Out 13 DL MON PWR ALM DL Out PWR ALM DL Out DL MON PWR ALM DL Out Path A DL MON PWR KMW Path A DL MON PWR KMW Modem ALM DL MON VHF UHF UL MON VHF UHF UL Out #1 IN UL MON UL MON UL MON UL MON DL Out UL MON UL MON UL MON #1 #1 OUT IN #1 #1 OUT #1 #1 DL #1 UL In UL In UL In UL In UL In UL UL In UL In #2 #2 #2 #2 #2 #2 #3 #3 #3 #3 #3 #3 #2 DL H-SRU UL #2 T-Sync Run Link ENT Up ALM Reset Down ESC Path B PS800 Path B Path B Path B Path B DL MON DL MON DL MON DL MON DL MON DL MON #3 #4 #4 #4 #4 #4 #4 #5 #5 #5 #5 #5 #5 #6 #6 #6 #6 #6 #6 #7 #7 #7 #7 #7 #7 DL In #8 #8 #8 #8 #8 T_Sync Path B #3 DL DL MON UL #4 DMCU DL Out DL Out DL Out DL Out UL MON DL Out DL Out UL Mon UL MON UL MON UL MON UL In UL MON UL MON UL MON DLOut UL In UL In UL In UL In UL In UL In UL In DL Web GUI UL #4 #8 DL SCM SCM FEM-L-7 FEM-L-P7/P8 FEM-L-S8 FEM-L-C #1 FEM-L-A FEM-L-W FEM-L-B #2 ] COM-8 UL DTM-8x8 HOM-L DTM-8x8 HOM Head-end Unit Front View #3 #4 #5 DMCU #6 #7 #8 HSRU Power SW H-PSU DL COM-8 FEM Figure 2-1 DMCU FEM-L-P UL External Alarm DMCU HPSU Input Output HPSU BRS WCS ┌ DL / UL (A) AWS PCS 850M S8 P7/P8 700M ┌ DL / UL (A) ┌ DL / UL (A) ┌ DL / UL (A) ┌ DL / UL (A) ┌ DL / UL (A) ┌ DL / UL (A) ┌ DL / UL (A) ┌ UL Div (A) ┌ UL Div (A) ┌ UL Div (A) ┌ UL Div (A) ┌ UL Div (A) ┌ UL Div (A) ┌ UL Div (A) - 30 - FUSE H-SRU #12 #11 #10 #9 #8 #7 #6 #5 #4 #3 #2 #1 Spare Fuse └ DL / UL (B) HOM DTM-8x8 COM-8 [ Figure 2-2 └ DL / UL (B) └ DL / UL (B) └ DL / UL (B) └ DL / UL (B) └ DL / UL (B) └ DL / UL (B) └ UL Div (B) └ UL Div (B) └ UL Div (B) └ UL Div (B) └ UL Div (B) └ UL Div (B) FEM - 30 - FAN SCM Head-end Unit Rear View 21 User Manual for POD Systems Head-end Unit consists of Revision: 0.9 H-DMCU (Head-end DAS Main Control Unit) H-PSU(Head-end Power Supply Unit) H-SRU(Head-end Subrack Unit) H-SCM(Head-end Subrack Control Module) H-FEM(Head-end Front End Module) H-COM(Head-end Combing Module) H-DTM(Head-end Distribution Module) HOM(Head-end Optic Module) H-STM(Head-end Sectorization Module) H-OEM(Head-end Optic Expansion Module) H-OIM(Head-end Optic Interface Module) Specification Size, weight, and power consumption Table 2-1 Size, weight, and power consumption (Head-end Unit) Size(H x W x D) inch POD-H-DMCU 2.1 x 19.0 x 19.7 POD-H-SRU POD-H-SCM POD-H-MCM POD-H-FEM-L POD-H-FEM-H POD-H-COM-8 POD-H-DTM-8x8 POD-H-HOM-L POD-H-HOM-H POD-H-STM-DL-8x4 POD-H-STM-UL-8x4 POD-H-OEM-B POD-H-OEM-S POD-H-OIM-B POD-H-OIM-S POD-H-PSU POD-H-PSM 7.0 x 19.0 x 19.7 7.0 x 1.8 x 17.8 7.0 x 3.1 x 17.8 7.0 x 1.3 x 17.8 7.0 x 2.5 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 2.5 x 17.8 7.0 x 2.5 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 1.7 x 19.0 x 19.7 7.0 x 2.5 x 17.8 POD-H-CDU 1.4 x 19.0 x 12.0 POD-H-FAU 1.4 x 17.3 x 10.6 Weight mm lb 52.4 x 482.6 x 6.6 499.5 177 x 482.6 x 499.5 16.3 177 x 46.5 x 452.5 2.9 177 x 79 x 452.5 Refer to Table 2-10 Refer to Table 2-14 177 x 31.8 x 452.5 5.5 177 x 64.1 x 452.5 11.5 177 x 31.8 x 452.5 5.5 177 x 31.8 x 452.5 177 x 64.1 x 452.5 11 177 x 64.1 x 452.5 11 177 x 31.8 x 452.5 5.3 177 x 31.8 x 452.5 5.5 177 x 31.8 x 452.5 5.3 177 x 31.8 x 452.5 5.5 44 x 482.6 x 499.5 13.9 177 x 64.1 x 452.5 35.2 x 482.6 x 2.4 304.2 36 x 440 x 270 3.5 Power consumption Kg (W) 3.0 28.5 7.4 1.3 2.5 5.2 2.5 4.1 2.4 2.5 2.4 2.5 6.3 16.2 24.0 4.8 12 30 30 30 30 30 30 85 @no load 1.1 1.6 12 Operating temperature: 14 ~ 122F (-10 ~ 50C) Power input H-FEM,H-COM, H-STM, H-DTM, H-HOM, H-OIM, H-FAU: DC 24V POD-H-PSU-AC/POD-H-PSM-AC: AC 100~240V (47~63Hz) POD-H-PSU-DC/POD-H-PSM-DC: DC -48V 22 User Manual for POD Systems 2.1.1 Revision: 0.9 POD-H-DMCU (DAS Main Control Unit) KMW Run ENT Link Up DMCU Alarm Down HE Alarm ESC RU Alarm Reset Modem 11 13 15 17 19 21 23 25 27 29 31 Web GUI 10 12 14 16 18 20 22 24 26 28 30 32 Power SW External Alarm DMCU HPSU Input Output Figure 2-3 POD-H-DMCU 2.1.1.1 Functions and features Controls, monitors, and generates alarms for all connected modules and units in a POD DAS system Supports up to 4 racks. Supports up to 4 H-OIMs and up to 6 H-OEMs. Provides web-based GUI interface to user Provides the user interface to control and monitor using LCD window and key pad. Send alarms to O&M system by SNMP. Ethernet port forward function Provides external input/output ports for external alarm monitoring 2.1.1.2 Specifications Size, weight, and power consumption: refer to Table 2-1 2.1.1.3 LED, LCD & Key PAD, Reset Figure 2-4 Link Up DMCU Alarm Down HE Alarm ESC RU Alarm Reset LED, LCD & Key PAD, Reset H-DMCU provides the user interface to control and monitor using LCD window and key pad. Reset ENT LCD window and key pad Run Used for H-DMCU reset. LED Table 2-2 POD-H-DMCU LED Operation Specifications Run Solid Green OFF Link Solid Yellow When power is on. When power is off. When H-DMCU cannot communicate with at least one module among modules which are directly connected to H-DMCU such as HSCM or H-PSU. 23 User Manual for POD Systems OFF DMCU Alarm HE Alarm RU Alarm Solid Yellow OFF Solid Yellow Solid Red OFF Solid Yellow Solid Red OFF Revision: 0.9 When H-DMCU communicates with all modules which are directly connected with H-DMCU such as H-SCM or H-PSU. When H-DMCU has minor alarm. When H-DMCU has no alarm. When at least one module or unit in the head-end has minor alarm. When at least one module or unit in the head-end has major alarm. When all modules and units in the head-end have no alarm. When at least one RU has minor alarm. When at least one RU has major alarm. When all RUs have no alarm. 2.1.1.4 Ethernet Ports Figure 2-5 Modem port Connected to wireless modem which provides connection with O&M center. Web GUI port Ethernet Ports Used to access to web-based GUI using notebook or desktop PC. 1~32 Ethernet Port Connected to H-SRU or H-PSU so that H-DMCU can monitor and control the connected H-PSUs and all modules installed in H-SRU. Connected to external device to provide port forwarding function. 2.1.1.5 DC power input port & power switch 24V DC power for DMCU is fed from POD-H-PSU and can be turned on or off by power switch. Power SW HPSU Figure 2-6 DC power input port & power switch 2.1.1.6 External Alarm Port H-DMCU provides 4 alarm inputs to get the alarm statuses of the connected any external devices. Then, the input conditions are reported to the O&M system. H-DMCU also provides 4 alarm outputs to control the external devices or to signal any alarm condition or status information to the external devices. 24 User Manual for POD Systems Revision: 0.9 External Alarm Input Figure 2-7 Table 2-3 Output External Alarm Ports Pin map - External Alarm Port Pin Assign Specifications External Input #1 External Input #2 External Input #3 External Input #4 External Output #1 External Output #2 External Output #3 External Output #4 External Alarm input #1 pin External Alarm input #2 pin External Alarm input #3 pin External Alarm input #4 pin External Alarm output #1 pin External Alarm output #2 pin External Alarm output #3 pin External Alarm output #4 pin 2.1.1.7 Ground port Refer to section 3.2.2 2.1.1.8 Alarms Table 2-4 Alarm Name POD-H-DMCU - Alarms Description Remedy Alarm LED Severity color Minor Yellow Minor Yellow High Temperature Temperature high Low Temperature Temperature too low Head-end Composite Head-end composite alarms Check Head-end unit Major/Minor RU Composite RU composite alarms Check RU Major/Minor External Input (1~4) External input signal Check connected external unit Minor Yellow AC Fail H-PSU AC Fail Check H-PSU Major Red DC Fail H-PSU DC Fail Check H-PSU Major Red PSU Comm. Fail H-PSU Communication Fail Check UDP cable connection Minor Yellow SCM Comm. Fail H-SCM Communication Fail Check UDP cable connection Minor Yellow Check environment Red/ Yellow Red/ Yellow 25 User Manual for POD Systems 2.1.2 Revision: 0.9 POD-H-SRU Figure 2-8 POD-H-SRU Front View HPSU - 30 - FUSE #12 #11 #10 #9 #8 #7 #6 #5 #4 #3 #2 #1 Spare Fuse - 30 - FAN Figure 2-9 POD-H-SRU Rear View 2.1.2.1 Functions and features One H-SRU supports 12 slot including one SCM and other modules such as H-FEM, H-COM, H-DTM, HOM. Supplies 24V DC power received from H-PSU to each individual module through the backboard. Supplies 24V DC power to H-FAU (Fan Unit) for dissipating heat comes from the modules installed in PODH-SRU. Provides communication path between installed modules and SCM through backboard. 2.1.2.2 Specifications Size, weight, and power consumption : refer to Table 2-1 2.1.2.3 DC input port & Fuse 26 User Manual for POD Systems Revision: 0.9 HPSU - 30 - Spare Fuse - 30 - FUSE Figure 2-10 DC Input port DC input port & Fuse The 24V DC power is supplied from H-PSU through this port, and this port includes H-SRU ID, rack ID which is set by ‘Rack ID’ dip switch in H-PSU. FUSE Current capacity: 15A The fuse protects the damages of all modules installed in H-SRU due to high current. H-SRU provides spare fuse for just in case fuse is broken. 2.1.2.4 FAN port FAN Figure 2-11 FAN port DC Power is supplied into the FAN Unit through this port. FAN fail alarm is transferred to H-SCM through this port. 2.1.2.5 Ground port Refer to section 3.2.2 27 User Manual for POD Systems 2.1.3 Revision: 0.9 POD-H-SCM Up Link Down ESC ALM Reset KMW Run Web GUI ENT DMCU SCM Figure 2-12 POD-H-SCM 2.1.3.1 Functions and features One H-SCM can be installed in one H-SRU. Provides web-based GUI interface to user Provides the user interface to control and monitor using LCD window and key pad. Provides physical path between H-DMCU and all modules in H-SRU Controls FAN on/off and FAN speed and monitors FAN alarm. Periodically, gather the data from all modules in H-SRU and send it to H-DMCU through DMCU port. Periodically, gather the data from RUs connected to H-HOM in H-SRU and send it to H-DMCU through DMCU port. 2.1.3.2 Specifications Size, weight, and power consumption : refer to Table 2-1 2.1.3.3 LED, LCD & Key PAD, Reset Figure 2-13 Link Up ALM Reset Down ESC LED, LCD & Key PAD LCD window and key pad Run ENT H-SCM provides the user interface to control and monitor using LCD window and key pad. Reset Used for H-SCM reset. Table 2-5 POD-H-SCM LED Operation Specifications RUN Link Alarm Solid Green OFF Solid Yellow OFF Solid Red When power is on. When power is off. When H-SCM cannot communicate with at least one module among modules installed in H-SRU. When H-SCM communicates with all modules installed in H-SRU. When H-SCM has major alarm. 28 User Manual for POD Systems Solid Yellow OFF Revision: 0.9 When H-SCM has minor alarm. When H-SCM has no alarm. 2.1.3.4 Ethernet Port Figure 2-14 DMCU port Ethernet Port Provides physical communication path between H-DMCU and all modules in H-SRU by connecting DMCU port of H-SCM to available one port among Ethernet port #1~#32 of H-DMCU. Web GUI port Used to access to web-based GUI using notebook or desktop PC. 2.1.3.5 Communication port Figure 2-15 Communication Port This port provides communication path between H-FEM-H-x, H-COM, H-DTM, H-STM, HOM-x or H-SCM installed in H-SRU through backboard of H-SRU. +24V DC is provided through this communication port from backboard of H-SRU. H-SCM acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-SCM is assigned automatically using the acquired ID information. 2.1.3.6 Alarms Table 2-6 Alarm Name POD-H-SCM - Alarms Description Remedy Alarm LED Severity color Minor Yellow Minor Yellow High Temperature Temperature high Low Temperature Temperature too low FAN FAN Fail Check FAN Minor Yellow Module Comm. Fail Module Communication Fail Check Module connection Minor Yellow Check environment 29 User Manual for POD Systems 2.1.4 Revision: 0.9 POD-H-MCM External Alarm Input Output Figure 2-16 POD-H-MCM 2.1.4.1 Functions and features In case of small size DAS system, H-MCM can replace H-DMCU. Controls, monitors, and generates alarms for all modules and units connected to H-MCM via Ethernet cable, backboard of H-SCM, or optic cable. Provides web-based GUI interface to user Provides the user interface to control and monitor using LCD window and key pad. Send alarms to O&M system by SNMP. Input/output ports for external alarm monitoring 2.1.4.2 Specifications Size, weight, and power consumption : refer to Table 2-1 2.1.4.3 LED, LCD & Key PAD, Reset 30 User Manual for POD Systems Figure 2-17 H-MCM provides the user interface to control and monitor using LCD window and key pad. Reset LED, LCD & Key PAD, Reset LCD window and key pad Revision: 0.9 Used for H-MCM reset. LED Table 2-7 POD-H-MCM LED Operation Specifications Run Solid Green OFF Blink Green Link OFF MCM Alarm Blink Green OFF Blink Green HE Alarm RU Alarm Solid Red OFF Blink Green Solid Red OFF When power is on. When power is off. When H-MCM cannot communicate with at least one module or units connected to H-MCM. When H-MCM communicates all modules and units connected to H-MCM. When H- MCM itself has minor alarm. When H- MCM itself has no alarm. When at least one module or unit connected to H-MCM has minor alarm. When at least one module or unit connected to H-MCM has major alarm. When all modules and units connected to H-MCM have no alarm. When at least one RU connected to H-MCM has minor alarm. When at least one RU connected to H-MCM has major alarm. When all RUs connected to H-MCM have no alarm. 2.1.4.4 Ethernet Ports Modem Connected to wireless modem which provides connection with O&M center. Web GUI port Ethernet ports Modem port HSRU 1 HSRU 2 HSRU 3 Web GUI Figure 2-18 Used to access to web-based GUI using notebook or desktop PC. HSRU1~HSRU3 Ethernet Port Connected to H-SRU so that H-MCM can monitor and control the connected all modules installed in H-SRU. 31 User Manual for POD Systems Revision: 0.9 2.1.4.5 External Alarm Ports POD-H-MCM provides 2 alarm inputs to get the alarm statuses of the connected any external devices. Then, the input conditions are reported to the O&M system. POD-H-MCM also provides 2 alarm outputs to control the external devices or to signal any alarm condition or status information to the external devices. External Alarm Input Output Figure 2-19 External Alarm Ports Figure 2-20 Communication Port 2.1.4.6 Communication port This port provides communication path between H-FEM-H-x, H-COM, H-DTM, H-STM, HOM-x or H-SCM installed in H-SRU through backboard of H-SRU. +24V DC is provided through this communication port from backboard of H-SRU. H-MCM acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-MCM is assigned automatically using the acquired ID information. 2.1.4.7 Alarms Table 2-8 Alarm Name POD-H-MCM - Alarms Description Remedy Alarm LED Severity color Minor Yellow Minor Yellow High Temperature Temperature high Low Temperature Temperature too low Head-end Composite Head-end composite alarms Check Head-end unit Major/Minor Red/ Yellow RU Composite RU composite alarms Check RU Major/Minor Red/ Yellow External Input (1~2) External input signal Check connected External unit Minor Yellow AC Fail H-PSU AC Fail Check H-PSU Major Red DC Fail H-PSU DC Fail Check H-PSU Major Red SCM Comm. Fail H-SCM Communication Fail Check UDP cable connection Minor Yellow Check environment 32 User Manual for POD Systems 2.1.5 Revision: 0.9 POD-H-FEM-L-x FEM-L-7 KMW FEM-LP7/P8 KMW FEM-L-S8 KMW FEM-L-C KMW KMW Path A PS700 Path A Path A DL MON DL MON DL MON DL MON PWR PWR ALM PWR ALM PWR ALM FEM-L-P KMW PCS PWR ALM FEM-L-A KMW FEM-L-B KMW Path A Path A Path A DL MON DL MON DL MON PWR ALM FEM-L-W PWR ALM PWR ALM ALM DL Out DL Out DL Out DL Out DL MON DL Out DL Out UL MON UL MON UL MON UL MON DL Out UL MON UL MON DL Out UL MON #1 UL In UL In UL In UL In UL In UL In UL In #2 T-Sync Path B PS800 Path B Path B Path B Path B DL MON DL MON DL MON DL MON DL MON DL MON DL Out DL Out DL Out DL Out DL Out DL Out UL MON #3 Path B DL MON DLOut #4 UL Mon UL MON UL MON UL MON UL In UL In UL In UL In FEM-L-7 700M FEM-L-P7/P8 P7/P8 FEM-L-S8 S8 FEM-L-C 850M UL In FEM-L-P PCS UL MON UL MON UL MON UL In UL In UL In FEM-L-A AWS FEM-L-W WCS ┌ DL / UL (A) ┌ DL / UL (A) ┌ DL / UL (A) ┌ DL / UL (A) ┌ DL / UL (A) ┌ DL / UL (A) ┌ DL / UL (A) ┌ UL Div (A) ┌ UL Div (A) ┌ UL Div (A) ┌ UL Div (A) ┌ UL Div (A) ┌ UL Div (A) ┌ UL Div (A) └ DL / UL (B) └ DL / UL (B) └ DL / UL (B) └ DL / UL (B) └ DL / UL (B) └ DL / UL (B) └ UL Div (B) └ UL Div (B) └ UL Div (B) └ UL Div (B) └ UL Div (B) └ UL Div (B) Figure 2-21 FEM-L-B BRS ┌ DL / UL (A) └ DL / UL (B) POD-H-FEM-L-x Front & Rear View 33 User Manual for POD Systems Revision: 0.9 2.1.5.1 Functions and features Provides the interface between DAS and Base station Provides independent two RF path except H-FEM-L-P ALC function for DL/UL Path Spectrum monitoring function for DL Input TDD Switching for TD-LTE (POD-H-FEM-L-B only) Acquisition and transmission of synchronization signal (POD-H-FEM-L-B only) 2.1.5.2 Specifications Frequency range Table 2-9 POD-H-FEM-L-x frequency range Downlink Comments 698~716 MHz (Lower ABC) 777~787 MHz (Upper C) 758~775 MHz (PS700) 788~805 MHz (PS700) 851~869 MHz (PS800) 806~824 MHz (PS800) 851~869 MHz 806~824 MHz 869~894 MHz 824~849 MHz 1930~1995 MHz 1850~1915 MHz 1710~1780 MHz 2110~2180 MHz (1710~1755 MHz for BDA application) 2350~2360 MHz 2305~2315 MHz 2496~2690 MHz POD-H-FEM-L-7 728~756 MHz POD-H-FEM-L-P7P8 POD-H-FEM-L-S8 POD-H-FEM-L-C POD-H-FEM-L-P POD-H-FEM-L-A POD-H-FEM-L-W POD-H-FEM-L-B Uplink TDD Input range -15~20dBm Table 2-10 POD-H-FEM-L-x Size, weight, and power consumption Size(H x W x D) POD-H-FEM-L-7 POD-H-FEM-L-P7P8 POD-H-FEM-L-S8 POD-H-FEM-L-C POD-H-FEM-L-P POD-H-FEM-L-A POD-H-FEM-L-W POD-H-FEM-L-B Weight Power consumption inch mm lb Kg (W) 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 177 x 31.8 x 452.5 177 x 31.8 x 452.5 177 x 31.8 x 452.5 177 x 31.8 x 452.5 177 x 31.8 x 452.5 177 x 31.8 x 452.5 177 x 31.8 x 452.5 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 22 16 16 15 12 12 13 34 User Manual for POD Systems Revision: 0.9 2.1.5.3 RF Port and LED H-FEM-L-7/P7P8/S8/C/A/W H-FEM-L-P H-FEM-L-B Path A Path A DL MON DL MON PWR PWR PWR ALM ALM DL MON ALM DL Out DL Out DL Out UL MON UL MON #1 UL In UL In Front Panel #2 T-Sync Path B #3 Path B DL MON DL MON UL MON DLOut DL Out UL In #4 UL MON UL MON UL In UL In DL / UL (A) DL / UL (A) UL Div (A) DL / UL (A) Rear Panel UL Div (A) DL / UL (B) DL / UL (B) UL Div (B) Figure 2-22 POD-H-FEM-L-x RF port and LED RF Ports DL/UL-A(B), UL-Div A(B) Linked to BTS RF ports When the RF port linked to BTS is duplex port, connect to DL/UL-A(B) When the RF ports linked to BTS are TX/RX port, connect DL/UL-A(B) to TX port and UL Div A(B) to RX port. Connector Type: SMA Female Connector Type: SMA DL MON-A(B), UL MON-A(B) Used to monitor DL input or UL output for path A or B Connector Type: SMB-L Female DL OUT-A(B), UL IN-A(B) DL OUT- A(B): DL output port for path A or B, Linked to H-COM or H-DTM UL IN- A(B): UL input port for path A or B, Linked to H-COM or H-DTM Connector Type: SMB-L Female 35 User Manual for POD Systems Revision: 0.9 LED Table 2-11 POD-H-FEM-L-x LED Operation Specifications PWR ALM DL Out UL In T-sync #1~#4 Solid Green Off Off Solid Yellow Solid Red Blink Green Blink Green Blink Green When power is on. When power is off. When H-FEM-L-x has no alarms. When H-FEM-L-x has minor alarm. When H-FEM-L-x has major alarm. At the cable connection guide, green led blinks to indicate which RF ports should be connected to. 2.1.5.4 Communication port Figure 2-23 Communication Port This port provides communication path between H-FEM-L-x and H-SCM through backboard of H-SRU. +24V DC is provided through this communication port from backboard of H-SRU. H-FEM-L-x acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-FEM-L-x is assigned automatically using the acquired ID information. 2.1.5.5 Alarms Table 2-12 Alarm Name High Temperature Description POD-H-FEM-L-x - Alarms Remedy Temperature too high Temperature high Check environment Alarm LED Severity color Major Red Minor Yellow Low Temperature Temperature too low Minor Yellow Downlink High Input power RF signal too high Check H-FEM downlink input level/ attenuator configuration/ALC status Major Red Major Yellow Uplink High Output Power RF signal too high Check H-FEM uplink input level/ attenuator configuration/ALC status Major Red Major Yellow Minor Yellow Major Yellow Major Red Warning Yellow Major Yellow RF signal high RF signal high Downlink Low Input Power RF signal too low Link Communication fail Freeze The final stage of Shutdown process Downlink ALC Activation Sync fail (H-FEM-L-B only) ALC activation No TDD sync signal is acquired Check H-FEM downlink input level/ attenuator configuration/RF cabling Check pin of communication port/ assigned IP address Check if shutdown process is going again after reset Check H-FEM downlink input level/ attenuator configuration Check H-FEM downlink signal input received from BTS 36 User Manual for POD Systems 2.1.6 Revision: 0.9 POD-H-FEM-H-x FEM-H-7 KMW FEM-H-P7 FEM-HS8(P8) KMW 700M FEM-H-C KMW PS700 SMR800 FEM-H-P KMW 850M FEM-H-A FEM-H-W KMW KMW AWS PCS FEM-H-B KMW WCS PWR PWR PWR PWR PWR PWR PWR ALM ALM ALM ALM ALM ALM ALM BRS PWR ALM DL MON DL MON DL MON DL MON DL MON DL MON DL MON DL Out DL Out DL Out DL Out DL Out DL Out DL Out DL MON DL Out #1 #2 T-Sync #3 UL MON UL MON UL MON UL MON UL MON UL MON UL MON UL MON #4 UL In FEM-H-7 UL Div UL In FEM-H-P7 UL Div UL In FEM-H-S8 UL Div Figure 2-24 UL In FEM-H-C UL Div UL In UL In FEM-H-A FEM-H-P UL Div UL Div UL In FEM-H-W UL In FEM-H-B UL Div POD-H-FEM-H-x Front & Rear View 37 User Manual for POD Systems Revision: 0.9 2.1.6.1 Functions and features Provides the interface between DAS and Base station ALC function for DL/UL Path Spectrum monitoring function for DL Input TDD Switching for TD-LTE (POD-H-FEM-H-B only) Acquisition and transmission of synchronization signal (POD-H-FEM-H-B only) 2.1.6.2 Specifications Frequency range Table 2-13 POD-H-FEM-H-x frequency range Downlink POD-H-FEM-L-7 728~756 MHz POD-H-FEM-L-P7 POD-H-FEM-L-P8 POD-H-FEM-L-S8 POD-H-FEM-L-C POD-H-FEM-L-P 758~775 MHz 851~869 MHz 851~869 MHz 869~894 MHz 1930~1995 MHz POD-H-FEM-L-A 2110~2180 MHz POD-H-FEM-L-W POD-H-FEM-L-B 2350~2360 MHz Uplink Comments 698~716 MHz (Lower ABC) 777~787 MHz (Upper C) 788~805 MHz 806~824 MHz 806~824 MHz 824~849 MHz 1850~1915 MHz 1710~1780 MHz (1710~1755 MHz for BDA application) 2305~2315 MHz 2496~2690 MHz TDD Input range 15~46dBm Table 2-14 POD-H-FEM-H-x Size, weight, and power consumption Size(H x W x D) POD-H-FEM-H-7 POD-H-FEM-H-P7 POD-H-FEM-H-P8(S8) POD-H-FEM-H-C POD-H-FEM-H-P POD-H-FEM-H-A POD-H-FEM-H-W POD-H-FEM-H-B POD-H-FEM-L-B Weight Power consumption inch mm lb Kg (W) 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 2.5 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 7.0 x 1.3 x 17.8 177 x 31.8 x 452.5 177 x 31.8 x 452.5 177 x 31.8 x 452.5 177 x 31.8 x 452.5 177 x 63.8 x 452.5 177 x 31.8 x 452.5 177 x 31.8 x 452.5 177 x 31.8 x 452.5 177 x 31.8 x 452.5 5.7 5.7 5.7 5.7 5.7 7.7 5.7 5.7 5.7 2.6 2.6 2.6 2.6 2.6 3.5 2.6 2.6 2.6 11.5 9.5 7.5 38 User Manual for POD Systems Revision: 0.9 2.1.6.3 RF port and LED H-FEM-L-7/P7/P8/S8/C/P/A/W H-FEM-L-B PWR PWR ALM ALM DL MON DL MON DL Out DL Out #1 #2 Front Panel T-Sync #3 UL MON UL MON #4 UL In UL In DL/UL DL/UL Rear Panel UL Div Figure 2-25 POD-H-FEM-H-x RF port and LED RF Ports DL/UL, UL-Div Linked to BTS RF ports When the RF port linked to BTS is duplex port, connect to DL/UL When the RF ports linked to BTS are TX/RX port, connect DL/UL to TX port and UL Div to RX port. Connector Type Mini DIN Female for DL/UL port SMA Female for UL div port Connector Type: SMA DL MON, UL MON Used to monitor DL input or UL output Connector Type: SMB-L Female DL OUT, UL IN DL OUT: DL output port, Linked to H-COM or H-DTM UL IN: UL input port, Linked to H-COM or H-DTM Connector Type: SMB-L Female 39 User Manual for POD Systems Revision: 0.9 LED Table 2-15 POD-H-FEM-H-x LED Operation Specifications PWR ALM DL Out UL In T-sync #1~#4 Solid Green Off Off Solid Yellow Solid Red Blink Green Blink Green Blink Green When power is on. When power is off. When H-FEM-H-x has no alarms. When H-FEM-H-x has minor alarm. When H-FEM-H-x has major alarm. At the cable connection guide, green led blinks to indicate which RF ports should be connected to. 2.1.6.4 Communication port Figure 2-26 Communication Port This port provides communication path between H-FEM-H-x and H-SCM through backboard of H-SRU. +24V DC is provided through this communication port from backboard of H-SRU. H-FEM-H-x acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-FEM-H-x is assigned automatically using the acquired ID information. 2.1.6.5 Alarms Table 2-16 Alarm Name High Temperature Description POD-H-FEM-H-x - Alarms Remedy Temperature too high Temperature high Check environment Alarm LED Severity color Major Red Minor Yellow Low Temperature Temperature too low Minor Yellow Downlink High Input Power RF signal too high Check H-FEM downlink input level/ attenuator configuration/ALC status Major Red Major Yellow Uplink High Output Power RF signal too high Check H-FEM uplink input level/ attenuator configuration/ALC status Major Red Major Yellow Minor Yellow Major Yellow Major Red Warning Yellow Major Yellow RF signal high RF signal high Downlink Low Input Power RF signal too low Link Communication fail Freeze The final stage of Shutdown process Downlink ALC Activation Sync fail (H-FEM-L-B only) ALC activation No TDD sync signal is acquired Check H-FEM downlink input level/ attenuator configuration/RF cabling Check pin of communication port/ assigned IP address Check if shutdown process is going again after reset Check H-FEM downlink input level/ attenuator configuration Check H-FEM downlink signal input received from BTS 40 User Manual for POD Systems 2.1.7 Revision: 0.9 POD-H-COM-8 KMW UL COM ALM DL COM #1 PWR #1 #4 #2 #4 #5 #2 #5 #6 #3 #6 #7 #3 #7 #8 UL #8 DL COM-8 Figure 2-27 POD-H-COM-8 2.1.7.1 Functions and features Combines DL output signals received from H-FEM and transfers to H-DTM, or H-HOM Receives UL signal from H-DTM, or H-HOM and distributes to H-FEM Control Power Ratio for multiple H-FEM with same frequency band to share DL output power at RU ALC function for DL/UL Path To minimize negative effects by unused input/output ports such as the degradation of VSWR or isolation between ports, the unused ports can be switched into 50 ohm termination by user. When any one sector or DAS system needs low power RU less than 4, H-COM can be connected to H-HOML directly without H-DTM. In this case, the attenuator in the common path of H-COM should add 15dB attenuation using web based GUI to compensate the loss of H-DTM.. 2.1.7.2 Specifications Frequency range: 600~2700MHz Maximum RF Power: -10dBm@DL, -25dBm@UL Size, weight, and power consumption : refer to Table 2-1 2.1.7.3 RF port and LED #1 DL COM #2 #1 UL COM PWR #2 #3 ALM #3 #4 #5 #4 #5 #6 #7 #6 #7 #8 UL #8 DL Figure 2-28 POD-H-COM-8 RF port and LED RF Port DL #1 ~ #8 Receives downlink signal from up to 8 H-FEM Connected to DL output port of H-FEM Connector Type: SMB-L Female DL COM Combines inputted downlink signals from DL #1 to DL #8 and outputs to H-DTM or H-HOM Connected to DL input port of H-DTM, or H-HOM Connector Type: SMB-L Female UL COM Receives uplink signal from H-DTM or H-HOM Connected to UL output port of H-DTM, or H-HOM Connector Type: SMB-L Female UL #1 ~ #8 Divides inputted uplink signals from UL COM port and outputs to H-FEM 41 User Manual for POD Systems Revision: 0.9 Connected to UL input port of H-FEM Connector Type: SMB-L Female LED Table 2-17 POD-H-COM-8 LED Operation Specifications PWR Solid Green Off Off Solid Yellow Solid Red Blink Green Blink Green Blink Green Blink Green ALM DL #1 ~ #8 DL COM UL #1 ~ #8 UL COM When power is on. When power is off. When POD-H-COM-8 has no alarms. When POD-H-COM-8 has minor alarm. When POD-H-COM-8 has major alarm. At the cable connection guide, green led blinks to indicate which RF ports should be connected to. 2.1.7.4 Communication port Figure 2-29 Communication Port This port provides communication path between H-COM-8 and H-SCM through backboard of H-SRU. +24V DC is provided through this communication port from backboard of H-SRU. H-COM-8 acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-COM-8 is assigned automatically using the acquired ID information. 2.1.7.5 Alarms Table 2-18 Alarm Name High Temperature Description Remedy Temperature too high Temperature high Low Temperature POD-H-COM-8 - Alarms Check environment Temperature too low Link Communication fail Downlink ALC Activation ALC activation Check pin of communication port/ assigned IP address Check H-COM-8 downlink input level/ attenuator configuration Alarm LED Severity color Major Red Minor Yellow Minor Yellow Major Yellow Warning Yellow 42 User Manual for POD Systems 2.1.8 Revision: 0.9 POD-H-DTM-8x8 VHF UHF OUT #1 PWR DL MON #1 VHF UHF OUT IN #1 ALM #1 KMW IN #2 DTM-8x8 UL UL MON #4 #2 #4 #5 #2 #4 #5 #6 #2 #4 #5 #6 #7 #3 #5 #6 #7 #8 #3 #6 #7 #8 #3 #7 #8 #3 #8 DL Figure 2-30 POD-H-COM-8 2.1.8.1 Functions and features Receives downlink signals from up to 8 H-COM. After then, it combines and distributes them to up to 8 HHOM. Receives uplink signals from up to 8 H-HOM. After then, it combines and distributes them to up to 8 H-COM. Combines or distributes VHF, UHF signals To minimize negative effects by unused input/output ports such as the degradation of VSWR or isolation between ports, the unused ports can be switched into 50 ohm termination by user Support Monitoring Port(DL path/UL Path) When any one sector or DAS system needs low power RU less than 4, H-COM can be connected to H-HOML directly without H-DTM. In this case, the attenuator in the common path of H-COM should add 15dB attenuation using web based GUI to compensate the loss of H-DTM. 2.1.8.2 Specifications Frequency range: VHF, UHF, 600~2700MHz Maximum RF Power: -25dBm@DL, -15dBm@UL Size, weight, and power consumption : refer to Table 2-1 2.1.8.3 RF port and LED IN #1 VHF UHF #2 OUT IN #1 DL MON #3 #2 #1 VHF UHF #4 #3 #2 OUT #1 UL MON PWR #2 #3 #4 UL ALM #3 #4 #6 #4 #6 #7 #5 #6 #7 #8 #5 #6 #7 #8 #5 #7 #8 #5 #8 DL Figure 2-31 POD-H-DTM-8x8 RF port and LED RF Port DL IN #1 ~ #8 Receives downlink signal from H-COM, H-STM or H-OIM. Connected to DL output port of H-COM, H-STM or H-OIM Connector Type: SMB-L Female DL OUT #1 ~ #8 Combines inputted downlink signals from DL IN #1 to DL IN #8 and outputs to H-HOM 43 User Manual for POD Systems Revision: 0.9 Connected to DL input port of H-HOM Connector Type: SMB-L Female UL IN #1 ~ #8 Receives uplink signal from up to 8 H-HOM Connected to UL output port of H-HOM Connector Type: SMB-L Female UL OUT #1 ~ #8 Combines inputted uplink signals from UL IN #1 to UL IN #8 and outputs to H-COM, H-STM or H-OIM Connected to UL input port of H-COM, H-STM or H-OIM Connector Type: SMB-L Female LED Table 2-19 POD-H-DTM-8x8 LED Operation Specifications PWR ALM DL IN #1 ~ #8 DL OUT #1 ~ #8 UL IN #1 ~ #8 UL OUT #1 ~ #8 Solid Green Off Off Solid Yellow Solid Red Blink Green Blink Green Blink Green Blink Green When power is on. When power is off. When POD-H-DTM-8x8 has no alarms. When POD-H-DTM-8x8 has minor alarm. When POD-H-DTM-8x8 has major alarm. At the cable connection guide, green led blinks to indicate which RF ports should be connected to. 2.1.8.4 Communication port Figure 2-32 Communication Port This port provides communication path between H-DTM-8x8 and H-SCM through backboard of H-SRU. +24V DC is provided through this communication port from backboard of H-SRU. H-DTM-8x8 acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-DTM-8x8 is assigned automatically using the acquired ID information. 2.1.8.5 Alarms Table 2-20 Alarm Name High Temperature Description Remedy Temperature too high Temperature high Low Temperature POD-H-DTM-8x8 - Alarms Check environment Temperature too low Link Communication fail Downlink ALC Activation ALC activation Check pin of communication port/ assigned IP address Check H-DTM downlink input level/ attenuator configuration Alarm LED Severity color Major Red Minor Yellow Minor Yellow Major Yellow Warning Yellow 44 User Manual for POD Systems 2.1.9 Revision: 0.9 POD-H-HOM-L KMW PWR ALM DL UL DL UL UL DL DL UL UL Out DL In T_Sync #1 #2 #3 #4 HOM-L Figure 2-33 POD-H-HOM-L 2.1.9.1 Functions and features Converts Downlink RF signal into optical signal and transfers to low power Remote Unit with less than 1W. Converts Uplink optic signal received from low power Remote Unit to RF signal and transfers to H-COM, HSTM, or H-DTM. Compensates optic loss between HOM-L and low power Remote unit. For 2.6G TDD operation, TDD synchronization signal received from H-FEM-B is transferred to low power Remote unit via H-HOM-L. Communicates with low power Remote unit by PLC modem. 2.1.9.2 Specifications Frequency range: VHF, UHF, 600~2700MHz Maximum RF Power: -9dBm@DL, 0dBm@UL Size, weight, and power consumption : refer to Table 2-1 2.1.9.3 RF port and LED PWR ALM UL DL UL DL UL Out POD-H-HOM-L RF port and LED RF Port UL DL In DL DL UL T_Sync Figure 2-34 DL IN Receives downlink signal from H-COM, H-STM or H-DTM. Connected to DL output port of H-COM, H-STM or H- DTM. Connector Type: SMB-L Female UL OUT Outputs uplink signal to H-COM, H-STM or H-DTM Connected to UL input port of H-COM, H-STM or H-DTM Connector Type: SMB-L Female T-SYNC IN Receives TDD synchronization signal from H-FEM-B. Connected to T-SYNC of H-FEM-B. Connector Type: SMB-L Female LED Table 2-21 POD-H-HOM-L LED Operation Specifications PWR ALM Solid Green Off Off Solid Yellow Solid Red When power is on. When power is off. When POD-H-HOM-L has no alarms. When POD-H-HOM-L has minor alarm. When POD-H-HOM-L has major alarm. 45 User Manual for POD Systems Off Solid Yellow Blink Green Blink Green Blink Green UL #1 ~ #4 DL IN UL OUT T_Sync Revision: 0.9 When PD fails. When PD is Normal. At the cable connection guide, green led blinks to indicate which RF ports should be connected to. 2.1.9.4 Optic port optic port LD #1 ~ #4 #1 #2 #3 #4 Figure 2-35 Each optic port is connected to one low power Remote Unit. Transfers downlink optic signal to low power Remote Unit. Connector Type: LC APC Female PD #1 ~ #4 Each optic port is connected to low power Remote Unit. Receives Uplink optic signal from low power Remote Unit. Connector Type: LC APC Female 2.1.9.5 Communication port Figure 2-36 Communication Port This port provides communication path between H-HOM-L and H-SCM through backboard of H-SRU. +24V DC is provided through this communication port from backboard of H-SRU. H-HOM-L acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-HOM-L is assigned automatically using the acquired ID information. 2.1.9.6 Alarms Table 2-22 Alarm Name High Temperature Description Remedy Temperature too high Temperature high Low Temperature POD-H-HOM-L - Alarms Check environment Temperature too low Link Communication fail DL Optic Fail Downlink LD fail UL Optic Fail Uplink PD fail Check pin of communication port/ assigned IP address Check if optic LD fail alarm occurs again after reset. Check optic cable connection with RU UL Optic Loss Exceed permitted optic loss Check optic cable connection with RU / clean Optic connector and port Alarm LED Severity color Major Red Minor Yellow Minor Yellow Major Yellow Major Yellow Major Yellow Minor Yellow 46 User Manual for POD Systems Alarm Name RU Comm. Fail Description RU Communication Fail Remedy Check optic cable connection Revision: 0.9 Alarm LED Severity color Minor Yellow 47 User Manual for POD Systems 2.1.10 Revision: 0.9 POD-H-HOM-H KMW ALM PWR UL1 DL/UL DL1 T_Sync HOM-H UL2 DL2 #1 Figure 2-37 POD-H-HOM-H 2.1.10.1 Functions and features Converts Downlink RF signal into optical signal and transfers to high power Remote Unit with more than 20W. Converts Uplink optic signal received from high power Remote Unit to RF signal and transfers to H-COM, HSTM, or H-DTM. Compensates optic loss between HOM-L and high power Remote unit. For 2.6G TDD operation, TDD synchronization signal received from H-FEM-B is transferred to high power Remote unit via H-HOM-L. Communicates with high power Remote unit by PLC modem. 2.1.10.2 Specifications Frequency range: VHF, UHF, 600~2700MHz Maximum RF Power: -9dBm@DL, 0dBm@UL Size, weight, and power consumption : refer to Table 2-1 2.1.10.3 RF port and LED PWR UL2 POD-H-HOM-H RF port and LED RF Port UL1 DL2 ALM DL/UL DL1 T_Sync Figure 2-38 DL 1/DL 2 Receives downlink signal from H-COM, H-STM or H-DTM. Connected to DL output port of H-COM, H-STM or H- DTM. Connector Type: SMB-L Female UL 1/UL 2 Outputs uplink signal to H-COM, H-STM or H-DTM Connected to UL input port of H-COM, H-STM or H-DTM Connector Type: SMB-L Female T-SYNC IN Receives TDD synchronization signal from H-FEM-B. Connected to T-SYNC of H-FEM-B. Connector Type: SMB-L Female LED 48 User Manual for POD Systems Table 2-23 Revision: 0.9 POD-H-HOM-L LED Operation Specifications PWR Solid Green Off Off Solid Yellow Solid Red Off Solid Yellow Blink Green Blink Green Blink Green ALM DL/UL DL 1/DL 2 UL 1/UL 2 T_Sync When power is on. When power is off. When POD-H-HOM-H has no alarms. When POD-H-HOM-H has minor alarm. When POD-H-HOM-H has major alarm. When PD fails. When PD is Normal. At the cable connection guide, green led blinks to indicate which RF ports should be connected to. 2.1.10.4 Optic port #1 Figure 2-39 LD optic port Connected to high power Remote Unit. Transfers downlink optic signal to high power Remote Unit. Connector Type: LC APC Female PD Connected to high power Remote Unit. Receives Uplink optic signal from high power Remote Unit. Connector Type: LC APC Female 2.1.10.5 Communication port Figure 2-40 Communication Port This port provides communication path between H-HOM-H and H-SCM through backboard of H-SRU. +24V DC is provided through this communication port from backboard of H-SRU. H-HOM-H acquires ID information such as Rack ID, Sub rack ID and Slot ID through this communication port. The IP address of H-HOM-H is assigned automatically using the acquired ID information. 2.1.10.6 Alarms Table 2-24 Alarm Name High Temperature Description Remedy Temperature too high Temperature high Low Temperature POD-H-HOM-H - Alarms Temperature too low Check environment Alarm LED Severity color Major Red Minor Yellow Minor Yellow 49 User Manual for POD Systems Link Communication fail DL Optic Fail Downlink LD fail UL Optic Fail Uplink PD fail Exceed permitted optic loss RU Communication Fail UL Optic Loss RU Comm. Fail Check pin of communication port/ assigned IP address Check if optic LD fail alarm occurs again after reset. Check optic cable connection with RU Check optic cable connection with RU / clean Optic connector and port Check optic cable connection Revision: 0.9 Major Yellow Major Yellow Major Yellow Minor Yellow Minor Yellow 50
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : bungckim Create Date : 2016:11:02 15:27:48+09:00 Modify Date : 2016:11:02 15:28:12+09:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2016:11:02 15:28:12+09:00 Creator Tool : Microsoft® Word 2013 Format : application/pdf Title : PDO User Manual Creator : bungckim Document ID : uuid:753f8aeb-9deb-4929-8271-269ce58e9a43 Instance ID : uuid:e9d48b38-3eea-4aab-b7f5-cc0c0d5668bb Producer : Microsoft® Word 2013 Page Count : 50EXIF Metadata provided by EXIF.tools