Kamstrup A S FLOW2100-3C Water Flow Meter User Manual 15 flowIQ2100 3c UserMan

Kamstrup A/S Water Flow Meter 15 flowIQ2100 3c UserMan

15_flowIQ2100-3c UserMan

Download: Kamstrup A S FLOW2100-3C Water Flow Meter User Manual 15 flowIQ2100 3c UserMan
Mirror Download [FCC.gov]Kamstrup A S FLOW2100-3C Water Flow Meter User Manual 15 flowIQ2100 3c UserMan
Document ID2914543
Application IDQe8U6mcIW6fz148yvjqTvQ==
Document Description15_flowIQ2100-3c UserMan
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize292.61kB (3657683 bits)
Date Submitted2016-02-29 00:00:00
Date Available2016-02-29 00:00:00
Creation Date2015-11-30 12:27:29
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2015-11-30 12:28:19
Document Title15_flowIQ2100-3c UserMan
Document CreatorAdobe InDesign CC 2015 (Windows)

Optional customer label, (not an option for Encoded Output version)
Optical eye for reading and configuration
Digital display showing consumption
Bar code with serial number
Type number
(includes information on
meter size, overall length etc.)
Nominal meter size Max. flow for continous operation
Temperature range
Serial no. and production year
Configuration of the adjustable parameters
Software version
Protection Class IP68 (Waterproof/submersible)
FCC identification
flowIQ® 2100 - Encoded Output version
The sealing surface of
the threaded connection
must be clean and level.
Caution: Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to
operate the equipment.
RF Exposure compliance statement: This device may be used with
no restrictions, since the source-based time-averaged output power
is ≤ 60/f(GHz) mW.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1 This device may not cause harmful interfenrence, and
2 This device must accept any interference received, including
interference that may cause undesired operation.
ALWAYS use new gaskets
(Kamstrup recommends
EPDM).
FCC Cautions
Torque
If a pipe installation is skewed to the effect that the prescribed
tightening torques would be exceeded, a meter setter or yoke should
be installed.
1”
Max. 30 Nm
flowIQ® 2100 - RF
& flowIQ® 2100 - Encoded Output
Installation guide
1”: Max. 30 Nm
Do not overtighten; max 30 Nm or 1/4 turn beyond handtight.
Kamstrup A/S • 55121224_F1_US_11.2015
The adjacent piping must be parallel
and match the meter in- and outlet.
1 General information
Read this guide before installing the water meter.
flowIQ® 2100 is a compact electronic water meter used for water
consumption measurement in the tap water supplies of homes,
commercial and industrial buildings.
flowIQ® 2100 is hermetically closed, and it is, therefore, impossible
to service the meter without breaking the seal. This means that all
service, must be carried out by an authorized Kamstrup Service
Centre.
Certain changes of configuration, however, are possible via the
built-in optical eye without dismounting the meter from the
installation. Further details appear in the data sheet.
1.1 Permissible operating conditions / measuring
ranges
Temperature media
- the water meter:
Pressure stage:
Mechanical environment:
Electromagnetic
environmental class:
Protection class:
Climatic environment:
33 °F...140 °F
250 PSI
Fixed installation with minimum
vibration.
Residential and commercial
IP68-rated (waterproof-submersible)
35 °F...140 °F. Condensing humidity.
(indoors mounted in utility rooms and
outdoors in meter pits). Installation
in direct sunlight must be avoided.
The meter must be protected from
freezing as well.
pipe installation must be corrected in order to remove strains.
Alternatively a meter setter or yoke must be installed.
Mounting the meter you must make sure that the threaded length
of the couplings does not prevent proper tightening of the sealing
surface and that couplings with similar pressure ratings are used.
For sealing, use the sealing wire holes on the lower side of the
threaded connections.
Prior to installation of flowIQ® 2100 the system should be cleaned
and flushed thoroughly. Then, install the meter with matching
couplings.
If an existing install, remove all traces of old gaskets and insert new
gaskets in original quality. Kamstrup recommends EPDM gaskets ,
which are included.
Install the meter according to the flow direction indicated by an
arrow on the side of the meter housing. An electrical grounding wire
must be installed according to local electrical regulation and for
safety reasons.
During installation it must be secured that the meter is mounted
without mechanical tension in the connection pipes. The piping
must be in line and match the meter. Do not attempt to install the
meter in a misaligned pipe system or in an opening that is too long.
Jacking the piping into place with the meter will seriously damage
the meter.
In a properly aligned piping system with new gaskets, you should be
able to mount and tighten the couplings by hand.
After hand-tightening the coupling nuts, using an open-end wrench,
tighten an extra ¼ to ½ turn on each coupling. Maximum allowable
torque is 30 Nm.
If a tight connection cannot be obtained within these limits, the
flowIQ® 2100 requires neither straight inlet nor straight outlet to
meet applicable AWWA standards. A straight inlet section will only
be necessary in case of heavy flow disturbances before the meter.
1.6 Operating pressure
Service
In order to avoid cavitation and secure correct measurement under
all circumstances the operating pressure in the pipe installation
should observe the test conditions of AWWA M6 manual. The static
pressure, immediately after the meter (downstream), must always
be minimum 5 PSI (0.3 bar).
1.3 Installation angle of flowIQ® 2100
1.7 Info codes and display
When the meter has been mounted in the system neither welding
nor freezing is allowed. Dismount the meter from the system before
starting such work.
In order to facilitate replacement of the meter, shut off valves
should be mounted on both sides of the meter.
The meter is supplied with a strainer in the inlet. Check valves must
be mounted according to local regulations.
flowIQ® 2100 can be mounted at all angles and positions.
Kamstrup Headquarters recommend that the display is mounted so
that it is easy to read, if possible.
Thus, the meter can be mounted in a plain horizontal installation. It
can be mounted vertically in an ascending pipe, it can be mounted
at any angle and it can be mounted with the display pointing
downwards, e.g under a roof.
Mounting the meter in a downpipe, you must be aware that the
display in that case will be ’upside down’.
1.2 Installation requirements
1.5 Straight inlet
Recommended water meter position.
Recommended water meter position.
Used for ”well installation”. Air build-up may occur.
The meter functions optimally, but the display is ’upside down’.
1.4 Encoded Output
When flowIQ® 2100 leaves Kamstrup Headquarters, it has been
tested and verified and the counter has been reset. The number
of gallons or CuFt are displayed by nine large digits (Bars over and
under digits indicates decimals after the comma). A number of
info codes can be displayed, of which ’DRY’ and ’RADIO OFF’ will be
activated and flash upon delivery. Furthermore, the small square in
the bottom right-hand corner flashes to indicate that the meter is
active.
Info code ’DRY’ indicates air in the meter, the info code disappears
when the meter is water-filled.
The info code ’RADIO OFF’ indicates that the meter is still in
transport mode with the built-in radio transmitter turned off. The
transmitter turns on automatically when the first quarter gallon of
water has run through the meter. The radio transmitter remains on,
and the info code signal in the display switches off The Encoded
Output version will not display ‘RADIO OFF’.
When the water is running, the symbol ’FLOW’ will turn on in the
display. If the water is stagnant, the symbol will be off.
The table below describes the different info codes in the display.
Ground Connection ’GND’
must be connected to the reading device ‘GND’.
The connection ‘Power/CLK’
must be connected to the reading device ‘CLK’.
The connection ‘Data Out’
must be connected to reading device ‘data input’.
GRN – Data out
BLK – GND –
RED – Power/CLK +
Info code flashes in the
display
LEAK
Meaning
BURST
The water flow has exceeded a
preprogrammed limit for minimum 30
minutes which is a sign of a burst pipe.
Attempt of fraud. The meter is no longer
valid for billing purposes.
The meter is not water-filled.
The water flows through the meter in the
wrong direction.
The meter is still in transport mode with
the built-in radio transmitter turned off.
The transmitter turns on automatically
when the first 1/4 gallon of water has run
through the meter.
One small flashing square indicates that
the meter is active.
The reading unit must comply with the electrical requirements of
the specification for the Sensus protocol UI 1203R20, September
2009.
Most important issues are listed below:
Type:			Open Drain
Maximum input voltage:
15V
Maximum current sink:
5mA
On voltage:		
< 0,4V @ 3,2mA
OFF condition:		
R > 6MΩ
Frequent reading, more than once per hour, will reduce battery life.
TAMPER
Compability table
* RF version only
Data
Ground
Power
Sensus
Grn
Blk
Red
ITRON
Red
White
Black
NEPTUNE
Red
Green
Black
DRY
REVERSE
RADIO OFF*
■ (Square ‘dot’)
The water has not been stagnant in the
meter during the last few days.
This can be a sign of a leaky faucet or
toilet cistern.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Create Date                     : 2015:11:30 12:27:29+01:00
Metadata Date                   : 2015:11:30 12:28:19+01:00
Modify Date                     : 2015:11:30 12:28:19+01:00
Creator Tool                    : Adobe InDesign CC 2015 (Windows)
Instance ID                     : uuid:fe741fb3-3401-42fb-8f61-aaee869b98e7
Original Document ID            : xmp.did:CE01E6A1DFEFE0118D6AC478EE4E4D07
Document ID                     : xmp.id:3807c96f-7ad3-7a46-8089-7e3aeec3f3c1
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:21123b89-d306-5d43-92ff-9984c35267a2
Derived From Document ID        : xmp.did:615193ff-40b0-b844-8487-e287b9042046
Derived From Original Document ID: xmp.did:CE01E6A1DFEFE0118D6AC478EE4E4D07
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Windows)
History Changed                 : /
History When                    : 2015:11:30 12:27:29+01:00
Canto Metadata                  : (Binary data 1267976 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CC 2015 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OUY-FLOW2100-3C

Navigation menu