Kamstrup A S FLOWX250 flowIQ 2250 or flowIQ 3250 User Manual user man 2250

Kamstrup A/S flowIQ 2250 or flowIQ 3250 user man 2250

Contents

user man 2250

Download: Kamstrup A S FLOWX250 flowIQ 2250 or flowIQ 3250 User Manual user man 2250
Mirror Download [FCC.gov]Kamstrup A S FLOWX250 flowIQ 2250 or flowIQ 3250 User Manual user man 2250
Document ID3565679
Application IDbnS+s+BZN/+ycIfNg6U+RQ==
Document Descriptionuser man 2250
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize215.82kB (2697783 bits)
Date Submitted2017-09-18 00:00:00
Date Available2018-03-13 00:00:00
Creation Date2017-08-29 08:21:35
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2017-08-29 08:22:52
Document Titleuser man 2250
Document CreatorAdobe InDesign CC 2017 (Windows)

Optical eye for reading and configuration
Digital display showing consumption
and billing in 100s of ft3
Optional customer label, (not an option for Encoded Output version)
Bar code with serial number, extended
availability and production year
Nominal meter size
Max. flow for continous operation
Toggle between volume, flow and
SW version via fingertouch
Type number
(includes information on meter
size, overall length etc.)
Maximum admissible pressure
FCC identification
Temperature range
Protection Class IP68 (Waterproof/submersible)
Mounting of antenna
The sealing surface of
the threaded connection
must be clean and level.
Torque, composite meters
If a pipe installation is skewed to the effect that the prescribed
tightening torques would be exceeded, a meter setter or yoke
should be installed.
¾”
1”
Max. 15 Nm
Max. 30 Nm
flowIQ® 2250
Installation guide
¾”: Max. 15 Nm
1”: Max. 30 Nm
Kamstrup A/S • DRAFT_55122048_C1_US_fccID_08.2017
The adjacent piping must be parallel
and match the meter in- and outlet.
FCC Cautions
ALWAYS use new gaskets
(Kamstrup recommends
EPDM).
NOTE! The antenna must only be mounted on the meter with the
antenna pointing upwards.
Make sure the terminal is dry and clean before clicking the
antenna into place.
Caution: Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to
operate the equipment.
RF Exposure compliance statement: This device may be used with
no restrictions, since the source-based time-averaged output power
is ≤ 60/f(GHz) mW.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1 This device may not cause harmful interfenrence, and
2 This device must accept any interference received, including
interference that may cause undesired operation.
Step 1: Push the base of the helix antenna through the seal housing.
Step 2: Align the antenna by using the terminals and steering pin
before clicking it into place.
1 General information
Read this guide before installing the water meter.
flowIQ® 2250 is a compact electronic water meter used for water
consumption measurement in the tap water supplies of homes,
commercial and industrial buildings.
flowIQ® 2250 is hermetically closed, and it is, therefore, impossible
to service the meter without breaking the seal. This means that all
service, must be carried out by an authorized Kamstrup Service
Centre.
Certain changes of configuration, however, are possible via the
built-in optical eye without dismounting the meter from the
installation. Further details appear in the data sheet.
1.1 Permissible operating conditions/measuring ranges
Fluid temperature:
- 1 part body meter:
- 2 part body meter:
Pressure stage:
Mechanical environment:
Electromagnetic
environmental class:
Protection class:
Climatic environment:
33 °F...140 °F
33 °F...120 °F
250 PSI
Fixed installation with minimum
vibration.
Residential and commercial
IP68-rated (waterproof-submersible)
35 °F...140 °F. Condensing humidity.
(indoors mounted in utility rooms and
outdoors in meter pits). Installation
in direct sunlight must be avoided.
The meter must be protected from
freezing as well.
In a properly aligned piping system with new gaskets, you should be
able to mount and tighten the couplings by hand.
After hand-tightening the coupling nuts, using an open-end wrench,
tighten an extra ¼ to ½ turn on each coupling.
Mounting the meter you must make sure that the threaded length
of the couplings does not prevent proper tightening of the sealing
surface and that couplings with similar pressure ratings are used.
For sealing, use the sealing wire holes on the lower side of the
threaded connections.
1.6 Info codes and display
Service
When flowIQ® 2250 leaves Kamstrup Headquarters, it has been
tested and verified and the counter has been reset.
The number of gallons or cu ft are displayed by nine large digits.
Bars over and under each digit are fully customizable, meaning that
they can be used to indicate numbers after the decimal point or
indicate if the customer is billed in e.g. tens or hundreds of gallons.
1.3 Installation angle of flowIQ® 2250
The table below describes the different info codes in the display.
When the meter has been mounted in the system neither welding
nor freezing is allowed. Dismount the meter from the system before
starting such work.
In order to facilitate replacement of the meter, shut off valves
should be mounted on both sides of the meter.
The meter is supplied with a strainer in the inlet. Check valves must
be mounted according to local regulations.
flowIQ® 2250 can be mounted at all angles and positions.
Kamstrup Headquarters recommend that the display is mounted so
that it is easy to read, if possible.
Thus, the meter can be mounted in a plain horizontal installation. It
can be mounted vertically in an ascending pipe, it can be mounted
at any angle and it can be mounted with the display pointing
downwards, e.g under a roof.
Mounting the meter in a downpipe, you must be aware that the
display in that case will be ’upside down’.
Info code flashes in the Meaning
display
Flow
The three segments will switch on alternately
to indicate flow in the meter
Backflow
Indication if there is reverse flow
Leak
The water has not been stagnant in the meter
during the past 24 hours. This can be a sign
of a leaky faucet or toilet.
The water flow has exceeded a preprogrammed limit for a minimum of 30 minutes,
which is a sign of a burst pipe.
The meter is not water-filled.
Burst
Dry
Tamper
Attempt of fraud. The meter is no longer valid
for billing purposes.
Radio OFF
Flow unit
The meter is still in transport mode with the
built-in radio transmitter turned off. The transmitter turns on automatically when the frst
1/4 gallon of water has run though the meter.
Indicates the configured flow unit.
Battery
Indication of the battery state.
Active meter
indication
Meter
adjustment
A small square is flashing to indicate that the
meter is active.
If the meter has been dismounted, tested
and the basic flow measurement has been
adjusted this info code will appear.
1.2 Installation requirements
Prior to installation of flowIQ® 2250 the system should be cleaned
and flushed thoroughly. Then, install the meter with matching
couplings.
If an existing install, remove all traces of old gaskets and insert new
gaskets in original quality. Kamstrup recommends EPDM gaskets ,
which are included.
Install the meter according to the flow direction indicated by an
arrow on the side of the meter housing. An electrical grounding wire
must be installed according to local electrical regulation and for
safety reasons.
You must always use new gaskets in original quality. Following
gaskets can be used:
¾”
Cold water
2 mm EPDM or PE
1”
3 mm EPDM or PE
The flow direction is indicated by an arrow on the side of the meter
case.
During installation it must be secured that the meter is mounted
without mechanical tension in the connection pipes. The couplings
must be tightened with maximum the following torque:
¾”
1”
15 Nm
30 Nm
If a tight connection cannot be obtained within these limits, the
pipe installation must be corrected in order to remove strains.
Alternatively a meter setter or yoke must be installed.
The piping must be in line and match the meter. Do not attempt
to install the meter in a misaligned pipe system or in an opening
that is too long. Jacking the piping into place with the meter will
seriously damage the meter.
Recommended water meter position.
Recommended water meter position.
Standard installation for pits.
The meter functions optimally, but the display is ’upside down’.
1.4 Straight inlet
flowIQ® 2250 requires neither straight inlet nor straight outlet to
meet applicable AWWA standards. A straight inlet section will only
be necessary in case of heavy flow disturbances before the meter.
1.5 Operating pressure
In order to avoid cavitation and secure correct measurement under
all circumstances the operating pressure in the pipe installation
should observe the test conditions of AWWA M6 manual. The static
pressure, immediately after the meter (downstream), must always
be minimum 5 PSI (0.3 bar).

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2017:08:29 08:21:35+02:00
Creator                         : Adobe InDesign CC 2017 (Windows)
Modify Date                     : 2017:08:29 08:22:52+02:00
Has XFA                         : No
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Metadata Date                   : 2017:08:29 08:22:52+02:00
Creator Tool                    : Adobe InDesign CC 2017 (Windows)
Instance ID                     : uuid:a444b1f7-7600-472c-9e88-b74e3cd96cc3
Original Document ID            : xmp.did:CE01E6A1DFEFE0118D6AC478EE4E4D07
Document ID                     : xmp.id:990f72f9-1e79-dd4c-a281-9978f2383b8c
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:5912af13-95e4-d140-8ff6-b6b6f1daaef6
Derived From Document ID        : xmp.did:94c6124e-26b5-2b4c-bdca-d3f61bbb3fd0
Derived From Original Document ID: xmp.did:CE01E6A1DFEFE0118D6AC478EE4E4D07
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Windows)
History Changed                 : /
History When                    : 2017:08:29 08:21:36+02:00
Canto Metadata                  : (Binary data 1267976 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Layout                     : SinglePage
Page Count                      : 2
Signing Date                    : 2017:08:29 08:22:52+02:00
Signing Authority               : ARE Acrobat Product v8.0 P23 0002337
Annotation Usage Rights         : Create, Delete, Modify, Copy, Import, Export
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OUY-FLOWX250

Navigation menu