   Kenetics Innovations Pte Ltd     SR14+ABC Transit Reader        CSC-RW Technical Manual           Document Number: SR14+ABC-TEC-0001 Version: 1.0 Date: 2009-01-06   Prepared by  Reviewed by Name  Seah Chian Jiunn  Ow Khiam Beng Signature     Date  2009-01-06  2009-01-06
Table of Contents Section 1: Amendment Record.............................................. 1 1.1 Change Log ....................................................................................... 2 Section 2: Introduction ............................................................ 3 2.1 Purpose................................................................................................ 3 2.2 Abbreviations ..................................................................................... 3 2.3 Terminology ........................................................................................ 3 Section 3: Hardware Specification......................................... 4 3.1 General Hardware Specifications .................................................. 4 3.2 Radio Frequency Interface Specification ..................................... 5 3.3 Physical Dimensions Specifications................................................. 6 3.4 Electrical Specifications.................................................................. 10 3.5 Field Strength Profile of CSC-RW ................................................... 11 Section 4: Operational Precautions ..................................... 12 4.1 General Safety Instructions ............................................................ 12 4.2 Installation ......................................................................................... 13 4.3 Diagnostic Status Indicators........................................................... 13 Section 5: Compliance Statement....................................... 14
Table of Figures  Figure 3.1  General Hardware Specifications........................................................ 4 Figure 3.2  On-board IO Ports Specification......................................................... 4 Figure 3.3  Radio Frequency Interface Specification ............................................ 5 Figure 3.4  Physical Dimensions Specifications ................................................... 6 Figure 3.5  SR14+ABC Reader general outlines................................................... 7 Figure 3.6  SR14+ABC Reader Mechanical Dimensions...................................... 8 Figure 3.7  SR14+ABC Reader Antenna Stackup................................................. 8 Figure 3.8  10 pin connector pin assignment......................................................... 9 Figure 3.9  Electrical Specifications................................................................... 10 Figure 3.10  Magnetic Field Strength profile of  SR14+ABC Reader................ 11 Figure 4.1  Installation Recommendations.......................................................... 13
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   1  Section 1:  Amendment Record  S/N By  Description  Date   Version 1  Seah  Draft Release  2008-11-20 0.1 2  Seah  Update for Final Design Documentation  2009-01-06 1.0
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   2  1.1   Change Log  Version 0.1 − Initial release. − Values documented in this draft document may not be finalized.  Version 1.0 -  Update for final design documentation
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   3    Section 2:  Introduction  2.1  Purpose The purpose of this document is to document the hardware specification of SR14+ABC reader. SR14+ABC reader is a contact-less smart reader, designed for automatic fare collection purpose.  2.2  Abbreviations  CSC-RW  Contact-less Smart Card Reader Writer, use interchangeably with SR14+ABC RF  Radio Frequency    2.3  Terminology  Main Board  Control board of SR14+ABC Reader Antenna Board  Antenna of SR14+ABC Reader
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   4   Section 3:  Hardware Specification  3.1  General Hardware Specifications      Embedded Processors / Memory CPU Types  Dual CPU Architecture, 1 RF CPU & 1 Application CPU. Secure Application Module ( SAM ) Number of SAMs  4 x SAM Slots  RF Specifications Operating Frequency  13.56 MHz (+/- 50 ppm) RF Output Power  Up to 0.7 Watt typical. Protocols Supported  ISO 14443-A, B & C  Reading Range  Memory Cards: up to 10cm CPU Cards:  up to 8.5cm Number of Outputs  2 UFL RF Outputs, Multiplexed and Alternating  Figure 3.1  General Hardware Specifications     On Board Ports 10 Pin, 2.54mm Pitch Power In 12VDC, RS232, RS485/TTL Mini-USB  USB Device  Physical Specifications Dimensions  67 x 104 x 18 mm Weight  200 Grams +/- 20 grams Antenna Type Antenna  1 x Shielded with Ferrite / Spacer Backed, Stackable  Figure 3.2  On-board IO Ports Specification
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   5  3.2  Radio Frequency Interface Specification  Specification of Radio Frequency Interface RF Protocol Supported  ISO 14443-A, B & C Card Supported   All ISO14443-X contactless cards Maximum Communication Range  Logic Card: Up to 10cm Microprocessor Card: Up to 8.5cm Operating Frequency  13.56MHz  RF Output Power  Up to 0.7 Watt Typical RF Connector Type  U.FL Figure 3.3  Radio Frequency Interface Specification
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   6   3.3  Physical Dimensions Specifications  Physical Dimension Specifications Connectors  •  10 pin, 2.54mm pitch right angled, connector •  Mini-USB connector Dimensions  Control Board with Antenna: 67 x 104 x 18 mm Material  PCBA FR4 Board Antenna  Separate PCB Antenna Cable Length (between PCBs )  Approx. 10cm Operating Temperature  -10°C to + 70°C (0% - 95% RH, non-condensing ) Storage Temperature  -20°C to + 85°C (0% - 95% RH, non-condensing) Special Treatment  Selective Conformal Coating Reference Figure  Figure 3.6  Figure 3.4  Physical Dimensions Specifications
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   7                                               Figure 3.5  SR14+ABC Reader general outlines1                                                   1 Stand-off and screws are not part of DCPS, and deliverables. J1 SR14+ABC Main Board SR14+ABC Antenna Board Antenna cable Antenna cable 104 mm 67 mm 67 mm  >20 mm SR14+ABC Main Board and Antenna Board assembled together
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   8       Figure 3.6  SR14+ABC Reader Mechanical Dimensions          Figure 3.7  SR14+ABC Reader Antenna Stackup
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   9                                              10-pin connector – Pin No.    Signals 1  Reset Control  SHDN 2  Power GND 3  Power  Power Supply (+12V) 4  RX- 5  RX+ (TTL-Rx) 6  TX- 7 RS485/TTL TX+(TTL-Tx) 8  TXD 9  Signal Ground 10 RS232 RXD Figure 3.8  10 pin connector pin assignment   The reader can be reset by in input voltage above 3 volts on pin 1 of the main connector - SHDN. Any high pulse longer than 500ms will trigger the hardware reset.   Pin 1 Pin 10
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   10   3.4  Electrical Specifications   Electrical Specifications Supply Voltage  12V DC +/- 10% regulated Maximum Voltage Ripple  200mVpp Maximum Supply Current  270 mA (@ room temperature & 50ohm-tuned antenna) Link to Host  USB, RS232 and RS485   Figure 3.9  Electrical Specifications
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   11  3.5  Field Strength Profile of CSC-RW    Min. Reading Field Strength   Figure 3.10 Magnetic Field Strength profile of  SR14+ABC Reader
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   12  Section 4:   Operational Precautions  4.1  General Safety Instructions  When using the SR14+ABC reader, general safety precautions should always be followed.  1.  Handle bare boards with care 2.  Only operate the product with the indicated power supply requirement
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   13   4.2  Installation  SR14+ABC reader is a contact-less smart card reader, which uses inductive coupling to communicate with contact-less cards. Precaution must be taken to keep the reader far enough from metal surfaces. Refers to table below for general guidelines. Installation of reader near a metal surface may dramatically shorten the operating distance and increase power consumption  Descriptions  Clearance Antenna positioned above metallic surface (ferrous or non-ferrous metal alike) Recommended to be > 20mm away Any edge or sides of the antenna against any metal surface (ferrous or non-ferrous metal alike) Recommended to be > 20mm away Any closed loop formed by metal in close proximity to antenna  To be avoided at all times! Especially within 100mm facing directly parallel to the antenna top face.  Figure 4.1  Installation Recommendations  Please notice that installation recommendations served as a general guidelines for SR14+ABC reader installation. It does not guarantee the performance to be consistent over every reader installed under different scenarios.  Fine-tuning or adjustment of the antenna may still be required to achieve optimal performance.     4.3  Diagnostic Status Indicators   Conditions  Descriptions LED – All 4 LED ON  Performing Power-On Self Test during Boot-up Any of 4 LED remains ON after Power-ON Self Test  If any of the 4 LEDs remain ON after Built-in Self Test on Power-Up, there is error occurred and should be send for technical troubleshooting.
SR14+ABC CSC-RW TECHNICAL MANUAL VERSION 1.0  CONFIDENTIAL   14  Section 5:  Compliance Statement  This product is currently pending certification for the following compliances:  1.  CE 2.  FCC 3.  EMC: EN61000-6-4: Part 6-4 – Generic Standards – Emission standard for industrial environment 4.  EMC: EN61000-6-2: Part 6-2 – Generic Standards – Immunity standard for industrial Environment  Regulatory Notes  An RFID system comprises an RF transmission device, and is therefore subject to national and international regulations. Prior to the powering and operation of the SR14+ABC reader, relevant compliance certificate should be obtained from the associated watchdog agency. Sale, lease or operation in some countries may be subject to prior approval by the respective government body or other international compliance organization. For operation of radio telecommunication equipment in the European Union or in countries where the CE (Conformité Européene) mark is recognized, Kenetics Innovations, hereby, declares that the SR14+ABC Reader is in compliance with the essential requirements and other relevant provisions of the European Council’s R&TTE directive 1999/5/EC. Note that the SR14+ABC Reader is supplied with its own integral antenna. Users and installers are welcomed to consult the R&TTE directive 1999/5/EC as well as the ETSI EN 302-291-1/2 harmonized standard whether further compliance testing is required if they intend to use their own antenna with SR14+ABC reader control board. In addition, the length of external cables connected to interface 10 pins of SR14+ABC reader should not exceed 3m. Cable lengths exceeding 3m may not necessarily degrade the performance of the reader but would have to be subject to further compliance test associated with the CE mark. Kenetics will not be liable for cable installations that exceed 3m. For countries requiring FCC certification, a typical system configuration containing the SR14+ABC reader has been tested and found to be compliant with the limits for a FCC Part 15C (intentional radiator) device. Nonetheless, it is still the responsibility of the customers to have their complete system tested and approved for use from the appropriate compliance agencies/authorities before operating or selling the system. As part of FCC part 15 compliance requirements, it should be noted that: •  Modifications not expressly approved by this company could void the user’s authority to operate the SR14+ABC reader. •  The SR14+ABC reader complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) The SR14+ABC reader may not cause harmful interference, and (2) must accept any interference received, including interference that may cause undesired operation.    ~~ End Of Document ~~