Owner's Manual and
Installation Instructions
240-Volt
COMPACT
ELECTRIC DRYERS

IMPORTANT:
Read and follow all safety
and operating instructions
before first use of this product.

Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
PART NO. 3406896

PRINTED iN U.S.A.

BEFORE USING YOUR NEW DRYER

2

SEARS COMPACT ELECTRIC DRYER WARRANTY

3

IMPORTANT SAFETY INSTRUCTIONS

4

INSTALLATION INSTRUCTIONS
OPERATING YOUR DRYER

26

LAUNDRY TIPS

31

CARING FOR YOUR DRYER

33

TROUBLESHOOTING

36

SEARS MAINTENANCE

AGREEMENT

Please read this manual, It will help you
install and operate your new Kenmore
compact dryer in the safest and most
economical way.
For more information about the care
and operation of Kenmore appliances
call your nearest Sears store, You will
need the complete model and serial
numbers when requesting information,
Your dryer's model and serial numbers
are located on the Model and Serial
Number Plate.

38

Use the space below to record the
model number and serial number of
your new Kenmore compact dryer.
Model No.
Serial No.
Date of Purchase

Keep this book and your Sears
Salescheck (receipt) in a safe place
for future reference,

OneYearWarranty
on
Mechanical
andElectricalParts

Warranty

For one year from the date of purchase,
if this dryer is installed and operated
according to the instructions in this
manual, Sears will repair or replace
any of its mechanical or electrical
parts if they are defective in material
or workmanship.

This warranty applies only while this
dryer is used in the United States.

NOTE: Exhausting your dryer with
plastic product may void this warranty.
Pages 21-24 of this manual describe
the complete exhaust requirements
for this dryer.

Service

Warranty service is available by
contacting your nearest Sears
Service Center in the United States.

This warranty gives you specific legal
rights, and you may also have other
rights which vary from state to state.
Sears, Roebuck and Co., Dept.
817WA, Hoffman Estates, IL 60179.

Your safety and the safety of others is very important.
We have provided many important safety messages in this manual
and on your appliance, Always read and obey all safety messages,
This is the safety alert symbol, This symbol alerts
you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety
alert symbol and the word "DANGER" or "WARNING,"
These words mean:
You will be killed or seriously
injured if you don't follow
instructions,
You can be killed or seriously
injured if you don't follow
instructions.
All safety messages will identify the hazard, tell you how to reduce the
chance of injury, and tell you what can happen if the instructions are
not followed.

3

YOUR SAFETY IS IMPORTANT

TO US.

WARNING: To reduce the risk of fire,
electric shock, or injury to persons when
using your dryer, follow basic precautions,
including the following:
• Read all instructions before using
the dryer.
• Do not dry articles that have been
previously cleaned in, washed in, soaked
in, or spotted with gasoline, dry-cleaning
solvents, other flammable or explosive
substances as they give off vapors that
could ignite or explode.
• Do not allow children to play on or in
the dryer. Close supervision of children
is necessary when the dryer is used
near children.
• Before the dryer is removed from service
or discarded, remove the door to the
drying compartment.
• Do not reach into the dryer if the drum
is moving.
• Do not install or store this dryer where
it will be exposed to the weather.

• Do not tamper with controls.
• Do not repair or replace any part of the
dryer or attempt any servicing unless
specifically recommended in the Owner's
Manual or in published user-repair
instructions that you understand and
have the skills to carry out.
• Do nat use fabric softeners or products
to eliminate static unless recommended
by the manufacturer of the fabric softener
or product.
• Do nat use heat to dry articles containing
foam rubber or similariy textured rubberlike materials.
• Clean Iint screen before or after each
load,
• Keep area around the exhaust opening
and adjacent surrounding areas free from
the accumulation of tint, dust, and dirt.
• The interior of the machine and exhaust
duct should be cleaned periodically by
qualified service personnel.

SAVE THESE INSTRUCTIONS

I
4

IMPORTANT:

Observe all governing codes and ordinances.

I

INSTALLATION

OVERVIEW

For a complete list of tools and parts
needed, see pages 5-7.
A, SELECT LOCATION
FOR YOUR DRYER (pgs. 8-10)
Standard Installation (p. 8)

Recessed Area/Closet Installation
Instructions (p. 9)

B, INSTALL LEVELING LEGS (p, 11)

Tools Needed:

Jstable
wrench

PaNs Needed:

Two corner posts
(from dryer carton)

4 leveling legs (supplied with dryer)
Flashlight (optional
depending on installation)

C, MAKE ELECTRICAL

CONNECTION

(pgs, 12-20)

Hold-down screw

Terminalblockcover

If using a power cord:
Tools Needed:

V4-1nch nut
driver (shown)
or socket wrench

Parts Needed:

#2 Phillips head
screwdriver

New 3- or 4-wire, 30-amp.
U.L.-listed power supply
cord kit (includes strain relief)
Flashlight {optional
depending
on installation)

If making a direct wire connection:

V4-1nch nut
driver (shown)
or socket wrench

Wire stripper

#2 Phillips head
screwdriver

Flashlight (optional
depending on installation)

10-gauge, 3- or 4-wire,
flexible armored
or non-metallic
sheathed copper cable
(with grounding wire)

314':U.h-listed,
strain relief

D, INSTALL KNOBS (p. 20)

PaNs Needed:

@

3 knobs(supplied with d_er)

PUSH TO START

CYCLE
SELECTOR

FABRIC/TEMPERATURE

E, CONNECT EXHAUST (pgs, 21-24)

i

Tools

•

PaNs Needed:

Needed:

Tin snips

Flashlight {optional
depending
on installation)

Duct tape

Flat-bladed
screwdriver

4-Inch rigid or
flexible heavy
metal vent

4-Inch outlet
exhaust hood

4-Inch metal elbow(s)
(optional depending
on installation)

(4) 4-Inch
diameter damps

7

A. SELECT LOCATION
FOR YOUR DRYER

Selecting the proper location for your
dryer makes installation easier and
gives you the best drying performance,
STANDARD

Explosion Hazard
Keep flammable materials and vapors,
such as gasoline, away from dryer.

INSTALLATION

Check location where dryer will be installed.
Proper installation is your responsibility.
Make sure you have everything necessary
for correct installation including proper
floor support, a level floor, and a separate
3g-amp. fuse.
• Protect dryer from the weather. Proper
operation of dryer cycles requires
temperatures above 45°F, At lower
temperatures, the dryer may not shut
off at the end of automatic cycles, and
drying times will be extended.

Place dryer at least 18 inches above
the floor for a garage installation.
Failure to follow these instructions
can result in death, explosion, or fire.
• Check code requirements. Some
codes limit or do not permit installation
of clothes dryers in garages, closets,
mobile homes, or sleeping quarters.
Contact your local building inspector.

J
_-

'

_

Separate

\
'_

Support: Floor must be
sturdy enough to support
a total weight of 110
pounds (includes dryer
and lead weight).

30.ompf_
OroonOe0r
/

Withinf 2 _;ee'°f either

Level floor: Maximum
allowable slope under entire
dryer - 3/_inch.

RECESSED AREA/CLOSET
INSTALLATION INSTRUCTIONS

PRODUCT DIMENSIONS

Check governing codes and ordinances.
This dryer may be installed in a recessed
area or closet.

Location must be large enough to fully
open dryer door.

Confined or Recessed Area Installation
The dryer must be exhausted outdoors,
The moisture and lint indoors may cause:
• Lint to gather inside and around the
dryer and be fuel for a fire.
• Moisture damage to woodwork, furniture,
paint, wallpaper, carpet, etc.
• Housecleaning problems and possible
health problems.

201/2"

Closet Installation
WARNING: To reduce the risk of fire, this
appliance must be exhausted outdoors
when installed in a closet.
NOTE: No fuel burning appliances may
be installed in the same closet as a dryer.

olo

3_

**48 sq. in.,
minimum_
ventilation
area

-18"

E}
_"
"---

**24 sq. in.,
minimum_
ventilatien

3"

area

t,,

"1"4
FrontView
(DoorNotShown)

SideView
(DoorShown)

FrontView
(Door WithVent)

MINIMUMINSTALLATION
SPACING,ClosetInstallationMUSTbe exhaustedoutside.
* Additionalclearancesforwall, doorand floormoldingsmaybe required.
** Openingis minimumfor closetdoor.Louvereddoorwith equivalentair openings
is acceptable,
** * Additionalspaceisneededwhenexternalexhaustelbowis used.

• The installation spacing is in inches
and is the minimum allowable.
• Additional spacing should be
considered for ease of installation
and servicing.

• If closet door is installed, the
minimum air openings in top and
bottom are required. Louvered doors
with equivalent air openings in top
and bottom are acceptable.

9

STAND KIT CLEARANCES
3"

12,,EIiiiiii
3"

*'1"÷

Front View

StackStand
(Door Dot Shown)

Side View

StackStand

Front View

(DoorWithVent)

(Door Shown)

* 1" dimensionmustbe fromfront oftimerknoh.
** Additionalclearancesfor wall, doorandDoormoldingsmay be required.
*** Openingis minimumforclosetdoor.Louvereddoorwithequivalentair openings
is acceptable.
• The installation
spacing is in inches
and is the minimum
allowable,

• For complete
installation
information,
order Stand Kit Installation
Instructions,
Part No, 49971/8, from your Sears
store or Sears Service Center.

MOBILE HOME EXHAUST
REQUIREMENTS
• The dryer must not be installed where
it will be exposed to water and/or
weather. Proper operation of dryer cycles
requires temperatures above 45°F.
At lower temperatures, the dryer may
not shut off at the end of automatic
cycles. Drying times will be extended.
This dryer is suitable for mobile home
installations. The installation must
conform to the Manufactured Home
Construction and Safety Standard,
Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Homes
Construction and Safety, Title 24,
HUD Part 280).
• Dryer exhaust vent must not be
connected or secured with screws
or other devices which extend into
the interior of the vent.

10

• If the dryer is exhausted outdoors,
the exhaust vent must be securely
fastened to a non-combustible
portion of the mobile home
structure and must _
not terminate
beneath the
mobile home.
• While in transit,
the dryer must
be securely

[,_

the floor. Order
fastened
to Installation
Mobile Home
Kit 346764 from your Sears
store or Sears Service Center,
Kit includes the necessary fastening
hardware and detailed installation
instructions.

B. INSTALL LEVELING LEGS

Leveling your dryer correctly will
reduce operating noise and provide
improved drying performance.
STEP 1. Take two of the cardboard
corners from the carton. Place them
on the floor in back of the dryer.
STEP 2. Firmly grasp the body of the
dryer. Gently lay dryer on the cardboard
corners.

STEP 3. Start to screw the legs into the
holes by hand. Use a wrench to finish
turning the legs. They should stick out
about 1 inch.

STEP 4. Now stand the dryer up
and move it close to its final location.
Leave enough room to connect the
exhaust vent.
STEP 5. Check levelness of dryer by
placing a level on top of the dryer, first
side4o-side; then front4o-back.

STEP 6. if dryer is not level, prop the
dryer up using two stacked cardboard
corner posts. Use a wrench to adjust
the legs up or down.

NOTE: it may be necessary to level
the dryer again after it is moved into
its final position.

11

C. MAKE ELECTRICAL
CONNECTION

ELECTRICAL

It is your responsibility:
• To contact a qualified electrical installer.
• To assure that the electrical installation
is adequate and in conformance with
the National Electrical Code, ANSll
NFPA 70-latest edition and all local
codes and ordinances.
Copies of the code standards listed
above may be obtained from:
National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts
02269

REQUIREMENTS

The proper electrical connection
ensures a safe installation that
meets local code requirements.
A three-wire or four-wire, single phase
120/240-volt 60-Hz., AC-only, electrical
supply (or three-wire or four-wire,
120/208-volt if specified on serial/rating
plate) is required on a separate 30-ampere
circuit, fused on both sides of the line.
A time-delay fuse or circuit breaker is
recommended.
This dryer is manufactured with the 3-wire,
frame-grounding conductor connected
to the NEUTRAL (center) of the wiring
harness of the terminal block. Do not
have a fuse in the neutral or grounding
circuit. A fuse in the neutral or grounding
circuit could result in an electrical shock.
Use a 4-conductor cord when the dryer
is installed in a mobile home or an
area where local codes do not permit
grounding through the neutral.

ELECTRICAL

CONNECTION

OPTIONS

If Your Home Has:

And You Will Be
Connecting To:

3-wire electrical
receptacle
(NEMA Type 10-30R)

A U.L.-listed, 120/240-volt
minimum, 30-amp., dryer
power supply cordt

13 - I.

3-wire direct

A fused disconnect or
circuit breaker boxt

14 - II.

4-wire electrical
receptacle
(NEMA Type 14-30R)

A U.L.-listed, 120/240-volt
minimum, 30-amp., dryer
power supply cord.

17 - III.

4-wire direct

A fused disconnect or
circuit breaker box.

19 - IV.

*If local codes do not permit the connection of a frame-grounding conductor
to the neutral wire, see the instructions on page 16.

12

Go To
Page

I. THREE-WIRE ELECTRICAL
CONNECTION TO RECEPTACLE
Do not use an extension cord with
this dryer.

Use a 3-wire power supply cord:

Do not connect plug end of power
supply cord into a live receptacle
before connecting power supply cord
to dryer terminal block,

GROUNDING
Electrical Shock Hazard
Turn power supply off before
connecting cord.
Use a new 30-ampere power
supply cord.
Plug into a grounded outlet.
Failure to follow these instructions
can result in death, fire, or electrical
shock.
Local codes may permit the use of
a U.L.-listed, 120/240-volt minimum,
30-ampere, dryer power supply cord
kit (pigtail). Power supply cord should
be type SRD or SRDT and be at least
four feet long. The wires that connect
to the dryer must end with ring terminals
or spade terminals with upturned ends.
Spadeterminals_
withupturnedends

.__

,.j_

INSTRUCTIONS

This appliance must be grounded.
In the event of malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of
least resistance for electric current. The
power supply cord must be plugged into
an appropriate outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.
WARNING: Improper connection of
the equipment-grounding
conductor can
result in a risk of electric shock, Check
with a qualified electrician or serviceman
if your are in doubt as to whether the
appliance is properly grounded.
Do not modify the plug on the power
supply cord. If it will not fit the outlet,
have a proper outlet installed by a
qualified electrician.
STEP 1. Turn power supply off.
STEP 2. Remove hold-down
and terminal block cover.

Thisbladeconnected

Ring
Terminalblockcover

strainrelief
Three-Wire

screw

(whiteor center)

Power Supply Cord

Hold-downscrew

\ /

The power supply cord must have three,
No.-10 copper wires to match a threewire receptacle of NEMA Type 10-30R.

Three-wire
receptacle
(NEMAType
10-30R)
13

STEP 3. Attach a 3/4-inch, U.L.qisted,
strain relief to the hole below terminal
block opening, Strain relief should have
a tight fit with dryer cabinet and be in a
horizontal position. Put the power supply
cord through the strain relief.
STEP 4. Loosen or remove terminal block
screws. Connect the neutral wire (white
or center) of power supply cord under
the center screw of the terminal block.
STEP 5. Connect the other two wires
to outer terminal block screws. Tighten
all terminal block screws firmly.
Externalground
connector

Centersilver-colored
terminalblockscrew

II. THREE-WIRE ELECTRICAL
CONNECTION (DIRECT WIRE)
Prepare cable as directed:

Electrical Shock Hazard
Turn power supply off before
connecting wires.
Use 10-gauge solid copper wire.
Electrically ground dryer.
Failure to follow these instructions
can result in death, fire, or electrical
shock.

The dryer can be connected directly
to fused disconnect or circuit breaker
Neutral box with three-wire, flexible armored or
wire
non-metallic sheathed copper cable
(white) (with grounding wire). All current-carrying
wires must be insulated.
A conduit connector must be installed at
junction box. Allow four feet of slack in the
line so dryer can be moved if servicing
is ever necessary.

GROUNDING

INSTRUCTIONS

This appliance must be connected to
a grounded metal, permanent wiring
3 II
/4, U.L.-listed,
system; or an equipment-grounding
strainrelief
conductor must be run with the circuit
conductors and connected to the
3-Wire Connection
with
equipment_grounding terminal or
Frame-Grounding Conductor
lead on the appliance.

Neutral
groundingwire
(green/yellow)

STEP 6. Tighten the strain relief screws.

STEP 1, Turn power supply off.

STEP 7. Insert tab of terminal block
cover into slot of the dryer rear panel.
Secure cover with hold-down screw.

STEP la. Strip 3Vz inches of outer
covering from end of cable.

If local codes do not permit the
connection of a frame-grounding
conductor to the neutral wire, see
the instructions on page 16.
Otherwise, proceed with Knob
Installation.
See "INSTALL KNOBS"
on page 20.

14

STEP lb. Cut 1 inch of insulation from
the end of each insulated wire. Shape
the end of each wire into a "U" shaped
hook.

STEP 4. Loosen or remove terminal block
screws. Connect the neutral wire (white
or center) of direct wire cable under the
center screw of the terminal block.
STEP 4a. Place the hook-shaped end
of the wire over the terminal
The open side of the hook should face
to the right. Squeeze hook end of wire
together to form a loop.

STEP 2. Remove hold-down
terminal block cover.
Terminalblockcover

screw and

Hold-downscrew

\ /

STEP 5. Connect the other two wires
to outer terminal block screws using the
same method(s) described in STEP 4a.
Tighten all terminal block screws firmly.
STEP 6. Tighten the strain relief screws.
STEP 7. Insert tab of terminal block
cover into slot of the dryer rear panel.
Secure cover with hold-down screw.

STEP 3. Attach a 3/4-inch, U,L,-listed,
strain relief to the hole below terminal
block opening. Strain relief should have
a tight fit with dryer cabinet and be in a
horizontal position. Put the direct wire
cable through the strain relief.
Externalgroond
connector

If local codes do not permit the
connection of a frame-grounding
conductor to the neutral wire, see
the instructions on page 16.
Otherwise, proceed with Knob
Installation.
See "INSTALL KNOBS"
on page 20.
Center silver-colored
terminal block screw

Neutral
"wire
(white)

Neutral grounding
wire (green/yellow)

_3/4'_

3-Wire Connection
with Direct Wire
and Frame-Grounding Conductor

U.L.-listed,
strainrelief

15

ALTERNATE CONNECTION:
If local codes do not permit the
connection of a frame-grounding
conductor to the neutral wire:
STEP 1. Make sure the power supply to
the dryer is off.
STEP 2. Make sure the power supply
cord or direct wire cable is in place (see
steps 1-3 on pages 13-14 for power cord
connections or steps 1-3 on pages 14-15
for direct wire connection).
STEP 3. Remove the neutral grounding
wire (green/yellow wire) from external
grounding connector screw. Loosen or
remove terminal block screws. Connect
neutral grounding wire and the neutral
wire (white or center) of power supply
cord or direct wire cable under the center
screw of the terminal block.

STEP 4. Connect the other two wires
to outer terminal block screws. Tighten
all terminal block screws firmly.
STEP 5, Tighten the strain relief screws.
STEP 6. Insert tab of terminal block
cover into slot of the dryer rear panel.
Secure cover with hold-down screw.
STEP 7. Connect separate copper
grounding wire from external ground
connector to an adequate ground, If
codes permit and a separate grounding
wire is used, it is recommended that a
qualified electrician determine that the
grounding path is adequate.
Proceed with Knob Installation.
See "INSTALL KNOBS" on page 20.

External

Neutral

ground
connector

grounding wire
(green/yellow)

Grounding path
determined by a
qualified electrician

Alternate 3-Wire Connection with
External-Grounding
Conductor

16

III. MAKE FOUR-WIRE ELECTRICAL
CONNECTION TO RECEPTACLE
Use a 4-wire power supply cord:

Do not use an extension cord with
this dryer.
Do not connect plug end of power
supply cord into a live receptacle before
connecting power supply cord to dryer
terminal block.

GROUNDING
Electrical

Shock Hazard

Turn power supply off before
connecting cord.
Use a new 30-ampere power
supply cord.
Plug into a grounded outlet.
Failure to follow these instructions
can result in death, fire, or
electrical shock.
Local codes may permit the use of
a U.L.-listed, 120/240-volt minimum,
30-ampere, dryer power supply cord
kit (pigtail). Power supply cord should
be type SRD or SRDT and be at least
four feet long. The wires that connect
to the dryer must end with ring terminals
or spade terminals with upturned ends.
NEUTRAL
_/4",U.L.-listed,

NEUTRAL
(white)

INSTRUCTIONS

This appliance must be grounded.
in the event of malfunction or breakdown, grounding will reduce the risk
of electric shock by providing a path
of least resistance for electric current.
The power supply cord must be plugged
into an appropriate outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.
WARNING: Improper connection of the
equipment-grounding
conductor can
result in a risk of electric shock, Check
with a qualified electrician or serviceman
if your are in doubt as to whether the
appliance is properly grounded.
Do not modify the plug on the power
supply cord, If it will not fit the outlet,
have a proper outlet installed by a
qualified electrician.
STEP 1. Turn power supply off.
STEP 2. Remove hold-down screw
and terminal block cover.
Terminalblockcover

strainG
relie_
prong

wire (green)

terminals

Four-Wire Power Supply Cord
(Mobile homeor other four-wire installations)
For mobile homes or other four-wire
installations, the power supply cord must
have four, No.-10 copper wires and
match a four-wire receptacle of NEMA
Type 14-30R. The fourth wire (grounding
conductor) must be identified with a
green cover or bare copper wire and the
neutral conductor by a white cover.

Hold-down
screw

\ /

Four-wire receptacle
(NEMAType 14-30R)
17

STEP 3. Attach a 3/4-inch, U,L,-listed,
strain relief to the hole below terminal
block opening. Strain relief should have
a tight fit with dryer cabinet and be in a
horizontal position, Put the power supply
cord through the strain relief,
STEP 4. Remove the center terminal
block screw, Remove the neutral grounding wire (green/yellow wire) from external
grounding screw.
Center silver-colored
terminal block screw

Externalground
connector

STEP & Connect neutral grounding wire
and the neutral wire (white) of power
supply cord under the center screw of
terminal block.
STEP 6. Connect the other two insulated
wires to outer terminal block screws.
STEP 7. Connect the green, grounding
wire from the power supply cord to the
external grounding conductor screw.
Tighten all terminal block screws firmly.
STEP 8, Tighten the strain relief screws.
STEP 9. Insert tab of terminal block
cover into slot of the dryer rear panel.
Secure cover with hold-down screw.
Proceed with Knob Installation.
See "INSTALL KNOBS" on page 20.

©
,c
Green/yellow
wire
of harness
External
ground
coeeeutor

Center silvercolored terminal
block screw

Green wire
ofpowersupply
cord or bare
copper wire

Neutral wire
(white)

Neutral
groundingwire

3/4_U.L-listed, strain
relief

4-Wire Connection with
Frame-Grounding Conductor
18

IV. FOUR-WIRE ELECTRICAL
CONNECTION (DIRECT WIRE)
Prepare cable as directed:

STEP lb. Cut l_/z inches from 3 remaining
insulated wires. Strip insulation back 1 inch.
Shape the end of each wire into a "U"
shaped hook.

Electrical Shock Hazard
Turn power supply off before
connecting wires.
Use 10-gauge solid copper wire.
Electrically ground dryer.
Failure to follow these instructions
can result in death, fire, or electrical
shock.
The dryer can be connected directly
to fused disconnect or circuit breaker
box with four-wire, flexible armored or
nommetallic sheathed copper cable
(with grounding wire), All current-carrying
wires must be insulated. The grounding
wire may be bare.
A conduit connector must be installed
at junction box. Allow four feet of slack
in the line so dryer can be moved if
servicing is ever necessary.
GROUNDING

INSTRUCTIONS

This appliance must be connected to
a grounded metal, permanent wiring
system; or an equipment-grounding
conductor must be run with the circuit
conductors and connected to the
equipment-grounding
terminal or lead
on the appliance.
STEP 1. Turn power supply off.

STEP 2. Remove hold-down screw
and terminal block cover.
Terminalblockcover

Hold-down
screw

STEP 3. Attach a 3/4-inch, U.L.qisted,
strain relief to the hole below terminal
block opening. Strain relief should have
a tight fit with dryer cabinet and be in
a horizontal position, Put the direct wire
cable through the strain relief.
STEP 4. Remove the center terminal
block screw, Remove the neutral ground*
ing wire (green/yellow wire) from external
grounding screw.
Center silver-colored
terminal block screw

External ground
connector

STEP la. Strip 5 inches of outer covering
from end of cable. Leave bare grounding
wire at 5 inches.

0
Green/yellowwire
of harness

19

D. INSTALL KNOBS
STEP & Connect neutral grounding wire
and the neutral wire (white or center) of
direct wire cable under the center screw
of terminal block.
Center silver-colored
terminal block screw

Externalground
connector

/
Bare copperwire

One large and two small knobs are
supplied with the dryer.
On the back side of each knob is a "D"
shaped notch, The "D" shaped notch will
fit onto the "D" shaped peg on the dryer
console.

Neutralwire (white) STEP 1. Firmly holding the large CYCLE
SELECTOR knob, align the "D" shaped
notch of the knob with the "D" shaped
CYCLE SELECTOR peg. Push knob
into place.

L "

Neutral
grounding
wire
(green/yellow)

3/4",&L-listed,
strainrelief
4-Wire Connection with Direct Wire
and Frame-Grounding
Conductor
STEP 6. Place the hook-shaped end of
the wire over the terminal block screw,
The open side of the hook should face
to the right. Squeeze hook end of wire
together to form a loop.

STEP 2. The small FABRIC TEMPERATURE
knob is identified by a temperature indicator
marking. Firmly holding the small FABRIC
TEMPERATURE knob, align the "D"
shaped notch of the knob with the "D"
shaped FABRIC TEMPERATURE peg.
Push knob into place.
STEP 3. Firmly holding the small PUSH
TO START knob, align the "D" shaped
notch of the knob with the "D" shaped
PUSH TO START peg. Push knob into
place.

STEP 7. Connect the other two wires
to outer terminal block screws. Use the
same method described in STEP 6.
STEP 8. Connect the direct wire cable
(bare) grounding wire to the externalgrounding conductor screw. Tighten all
terminal block screws firmly.
STEP 9. Tighten the strain relief screws.
STEP 10. Insert tab of terminal block
cover into slot of the dryer rear panel.
Secure cover with hold-down screw.
Proceed with Knob Installation.
2O

PUSH
TO START

FABRIC/
TEMPERATURE

@
CYCLE
SELECTOR

E. CONNECTEXHAUST

ROUTE THE VENT
Typical installations
rear of the dryer.

A properly exhausted dryer will give
you the shortest drying time, lower
your utility bill, and extend the life of
the dryer,

exhaust from the

Avoid pushing the dryer tightly against
a wall. This can crush or kink the vent.
Use the straightest path you can, where
possible. Avoid 90 ° turns.

Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions
can result in death or fire,
WARNING - To reduce the risk of fire,
this dryer MUST BE EXHAUSTED
OUTDOORS.
•
•
•
•

Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Do not exhaust dryer into a chimney,
a wall, a ceiling, or a concealed space
of a building.
• The diameter of the heavy metal vent
must be 4 inches.
• Do not use an exhaust hood with a
magnetic latch.
• If using an existing exhaust system,
disconnect vent from the dryer and
clean one section at a time until you
reach the exhaust hood. To clean out
lint, you can use the hose attachment
on your vacuum or, use a pole or wire
with a feather duster or rag attached.

• Make sure exhaust hood is not plugged
with lint. Follow the instructions in this
section to reinstall your vent system.

Rear exhaust installations for standard
offset connections - (see pgs. 22-23).

Rear exhaust installations for offset
connections with cIose clearances (see p. 24).

21

DETERMINE VENT LENGTH

STANDARD OFFSET CONNECTIONS

Maximum

Using 4-inch rigid heavy metal vent:

Exhaust

Lengths:

• The maximum length of the rear
exhaust system depends on the
type of vent, the number of elbows,
and the type of exhaust hood.
Refer to the chart below.
EXHAUST

HOOD TYPE

NOTE: Do not secure exhaust vent joints
with screws, Screws can catch lint and
slow the drying process. Instead, use
clamps to secure exhaust vent joints.
STEP 1. Install a 4-inch metal elbow on
the hood and on the dryer exhaust outlet.
STEP 2. Measure the length of 4-inch
rigid heavy metal vent needed to connect
the two elbows.
Elbow

/

Wall

xb0 as'
Number of
Maximum length of 4-inch
90° Turns diameter rigid heavy metal vent,
0
43 ft.
41 ft.
36 fl,
1
33 ft.
31 ft.
26 ft.
2
23ft.
21ft.
16ft.
Number of
Maximum length of 4-inch
90° Turns diameterflexible heavy metalvent.
0
30 ft.
29 ft.
24 ft.
1
24ft.
23ft.
18ft.
2
16ft.
15ft.
10ft.
If a combination of rigid metal vent and
flexible metal vent is used, use instructions
for flexible metal vent (see p. 23).

_Duct
tape&
clamps

heaw J_,...._

\
STEP 2

Dryer_,_

"_"Elbow

Ducttape&
clamps
The vent usually comes in 2-foot lengths.
Use tin snips to cut the vent 3 inches
longer than your measurement in order
to make a connection.

STEP 3. Place a clamp on each end of
vent elbow and connect elbow to dryer
outlet, Tape the joint with duct tape.
Tighten clamp.

Tape

Clamp

22

STEP 4. Connect vent to elbow.
Tape the joint with duct tape.
Tighten clamp.
STEP 5. Install one end of elbow on
vent, the other end to the exhaust hood.
Tape joints and tighten clamps.
Finish Installation.
See "REVIEW
INSTALLATION"
on page 25.

STEP 5. Place a clamp on each end of
vent elbow. Install one end of elbow on
vent, the other end to the exhaust hood.
Tape joints and tighten clamps.

Tape

Using 4-inch flexible heavy metal vent:

Clamp

NOTE: Do not secure exhaust vent joints
with screws. Screws can catch lint and
slow the drying process. Instead, use
clamps to secure exhaust vent joints.
STEP 1. Install a 4-inch metal elbow
on the exhaust hood and, if necessary,
on the dryer exhaust outlet.
STEP 2. Measure the length of 4-inch
flexible heavy metal vent needed from
the dryer to the hood.
Flexibleheavy
metalvent

Elbow

,.'Wall
Exhaust
hood
_Dact

\

tape &
clamp
" STEP 2

- Elbow
(optional)

STEP 6. Stretch the vent only as
needed by pulling out from the center
in each direction. Do not stretch vent
sections over 6 feet. If distance is more
than 6 feet, use 2 or more sections of
rigid vent with flexible metal vent
attached at ends.
STEP 7. Connect the vent directly to
the dryer outlet or to a separate elbow.
Tape the joints with duct tape. Secure
with clamps.
STEP 8. To fit the vent over the duct on
the hood it may be necessary to make
two V2-inch cuts in the end of the vent
to allow it to expand.

\
Ducttape& clamp
STEP 3. Add 10 inches to the measure_
ment for each bend in the vent.
STEP 4. Add 3 more inches to the
measurement for connection over the
dryer outlet and hood.

Finish Installation.
See "REVIEW
INSTALLATION" on page 25,

23

OFFSET CONNECTIONS
CLOSE CLEARANCES

WITH

When your exhaust vent is in a close
clearance behind the dryer, or if you are
installing your dryer in a recessed area
or closet, you will find it helpful to install
the exhaust vent over the top* of the
dryer, A kit is available from your local
Sears store or Sears Service Center.
*Parts may be covered by one or more
U.S. Patents.

NOTE: Vent systems come in many
varieties. Select the type that best fits
your installation. Three of the most
common types of installations are
illustrated here.

LOOP SYSTEM

I

I
I
I
I

I
I

Vent system installed over the top
with standard elbows

PERISCOPE

24

SYSTEM

Vent system
with one periscope
(2" clearance)

•

Vent system installed over the top
with one offset and one standard elbow

REVIEW INSTALLATION

Take a few minutes to complete
this checklist. It will help assure you
that you have a proper installation
and increase your satisfaction with
your Kenmore dryer.

[

Check that all parts you removed
from the parts packages are now
installed.

[

Ensure that dryer is positioned in
its final location. Make sure vent is
not crushed or kinked.

[

Ensure that dryer is level by placing
a level on top of the dryer, first sideto-side; then front-to-back, If dryer is
not level, adjust the legs up or down.

[

Check to make sure you have all
the tools you started with.

FINAL STEPS
[

Plug the power supply cord into the
grounded outlet or connect direct
wire to power supply.
[ Turn power supply on.
[

Wipe the interior of the drum
thoroughly with a damp cloth to
remove any dust.

V Read the rest of this manual to fully
understand your new dryer. Start the
dryer and allow it to complete a full
heat cycle (not the air cycle). After five
minutes, open dryer door, You should
feel heat inside the dryer. If you do
not feel heat, see Troubleshooting
information on pages 36-37.
NOTE: You may notice a burning odor.
This smell is common when the heating
element is first used. The smell will
go away.

25

STARTING YOUR DRYER

Fire Hazard
Explosion Hazard
Keep flammable materials and
vapors, such as gasoline, away
from dryer.
Do not dry anything that has ever
had anything flammable on it (even
after washing).
Failure to follow these instructions
can result in death, explosion,
or fire.

To get the best drying results, you must
operate your dryer properly. This section
gives you this important information.

No washer can completely
remove oil.
Do not dry anything that has ever
had any type of oil on it (including
cooking oils).
Items containing foam, rubber,
or plastic must be dried on a
clothesline or by using an air cycle.
Failure to follow these instructions
can result in death or fire.

STEP 3. Set Cycle Selector Control
(Timer)O
(see page 27).

STEP 1. Check lint screen. Clean
if needed.

STEP 4. Set FABRiC/Temperature
Control _; (see page 28), Check clothes
label for manufacturer's recommendations.

STEP 2. Put laundry into dryer and
shut door.

STEP 5, Press PUSH TO START
Button_
Be sure door is closed.

STOPPING/RESTARTING
YOUR DRYER
• To stop the dryer at any time, open
dryer door.
• To restart, press PUSH TO START
Button _. Be sure door is closed.
• If you wish to end your drying cycle,
turn Cycle Selector Control (Timer)
to OFR

26

CYCLE DESCRIPTION

The AUTO DRY Cycle saves you time
by providing the best drying results
in the shortest time. This can help
you save money on utility bills and
reduce the risk of fabric damage,
AUTO DRY CYCLE
Use this cycle for most loads, Drying
time varies according to type of fabric,
size of load, and dryness setting.
• Set the Cycle Selector Control (Timer)
to NORMAL DRY(*) which is good for
most fabrics.
• At the end of the cycle, feel the dried
clothes. If they are damp, select MORE
DRY the next time you do a similar load.
If they are overdried, select LESS DRY
the next time you do a similar load,
• Dryness is determined by thermostats
that react to the amount of moisture
in the air exhausted from the dryer.
Moist air indicates clothes are still
damp, dry air indicates that moisture
has been removed.

TIMED DRY CYCLE
Use this cycle to get up to 70 minutes
of heated drying time,
• The heating cycle is followed by a 10minute (approx.) COOL DOWN period.
• The End-of-Cycle Signal sounds once
the cycle is completed.
TOUCH UP CYCLE
Use this cycle to smooth synthetic and
permanent press clothes that are clean
but wrinkled from being crowded in a
closet or suitcase.
• This setting provides about 15 minutes
of heated tumbling followed by a 10minute (approx.) COOL DOWN period.
• Remove clothes immediately when
tumbling stops.

• The End-of-Cycle Signal sounds once
the cycle is completed.

27

FABRIC/TEMPERATURE

CONTROL
FABRIC
TEMPERATURE

PERMANENTPRESS

Proper use of this control helps
ensure that fabrics are dried at the
right temperature for maximum life,

ME_Ut_
DELICATE

Use this control to select the drying
temperature that matches the fabrics
in your load.
• Select LOW for delicate fabrics. Select
HIGH for durable fabrics such as sturdy
work clothes or bath towels.
• The FABRiC/Temperature Control
will not work when the Cycle Selector
Control (Timer) is in the AIR DRY Cycle.

L°W

COTTON

_

HF_

This table lists suggested dryer settings
and drying times for various loads. This
is only a guide. Settings may require
adjustment depending on the requirements
of your load.

AUTO DRY
Setting

Drying
Temp

TIMED DRY
Setting

Extra Heavy - Bedspreads, mattress
pads, quilts

MORE DRY

HIGH

60-70 mill.

Heavyweight - Towels, jeans, corduroys,
work clothes

MORE DRY

HIGH

50-60 rain.

NORMAL
DRY

MEDIUM

40-50 rain.

NORMAL DRY

LOW

30-40 rain.

Type of Load
COTTONS AND LINENS

Medium Weight - Sheets, cotton underwear,
diapers
Lightweight-

Batistes, organdies, lingerie

PERMANENT PRESS, SYNTHETICS AND BLENDS
Heavyweight - Work clothes, jackets,
raincoats

NORMAL
DRY

HIGH

40-50 rain.

Medium Weight - Shirts, play clothes,
sheets, slacks

NORMAL
DRY

MEDIUM

30-40 rain.

Lightweight-

LESS DRY

LOW

20-30 rain.

Heavyweight - Cottons, rayons, blends,
T-shirts, slacks, shirts

NORMAL
DRY

HIGH

40-50 rain.

Medium Weight - Synthetics (polyester,

NORMAL

MEDIUM

30-40 rain.

LOW

20-30 rain.

Lingerie, blouses, dresses

KNITS

28

acrylic, etc.), dress slacks, skirts, sweaters

DRY

Lightweight - Synthetics (polyester, acrylic,
etc.) and blends, lingerie, blouses, dresses

LESS DRY

USING AIR DRY

Using this cycle gives you all the
benefits of hang drying with a shorter
drying time,
Use the AIR DRY Cycle to get up
to 30 minutes of drying time in room
temperature air, Use this setting for
items that will not tolerate heat such as
plastics and foam rubber, Also use for
airing and fluffing items such as pillows.

Refer to the following table for examples
of items that require drying without heat.
Use the AIR DRY Cycle, or place the
items on a line or rack to air dry,

Type of Load

AIR DRY Cycle

DELICATE FABRICS
Sheer curtains (2 or 3 panels), gauze, lace, etc.
(Use AIR DRY if low heat is not available.)
RUBBER, PLASTIC, HEAT-SENSITIVE FABRICS
Foam rubber - Pillows, padded bras, stuffed toys
• Make sure coverings are securely stitched.
• Shake and fluff pillows by hand several times during the cycle.
• Make sure pillows are completely dry, Foam rubber pillows
take a long time to dry.*
Plastic - Shower curtains, tablecloths
Rubber-backed rugs
Olefin, polyprepylene, sheer nylon

20-30 min.

20-30 min.

20-30 min.
40-50 min.
10-20 min.

*Reset time, as needed, to allow these items to dry completely.

29

END-OF-CYCLE

SIGNAL CONTROL

Your dryer sounds a signal when
a drying cycle is finished.
The signal is helpful when you are
drying permanent press, synthetics,
and other items. These items should
be removed from the dryer as soon
as it stops in order to prevent wrinkles.
PUSH TO START BUTTON
Use this control to start the dryer. Be sure
the dryer door is closed.
Opening the door stops the dryer. It will
not start again until you close the door
and press the PUSH TO START Sutton,
Be sure the Cycle Selector Control (Timer)
is still on a drying cycle or air setting.
PUSH TO START

SOFT-HEAT ®SYSTEM

SOFT-HEAT ®System guards against
overdrying. This helps your fabrics
retain the natural moisture they need,
prevents static, and reduces pilling the formation of small lint-like balls
on the surface of garments. Pilling is
the natural result or wearing and
washing of garments.
Kenmore dryers help prevent overdrying
so you get outstanding fabric care. In
the AUTO DRY and TIMED DRY Cycles,
clothes are dried at the temperature
you selected until the last few minutes
of the cycle. The dryer then switches to
low heat.
COOLDOWN
Approximately ten minutes before the
end of the AUTO DRY and TIMED DRY
Cycles, clothes are tumbled without heat
to help reduce wrinkles and make clothes
more comfortable to handle.
USING WRINKLE GUARD

WRINKLE GUARD helps keep your
permanent press items wrinkle free
when you cannot unload the dryer
promptly at the end of the AUTO DRY
Cycle.
If you do not open the door at the end of
the AUTO DRY Cycle, WRINKLE GUARD
will tumble the clothes continuously for
30 minutes.
• This action will continue unless you
open the dryer door.
During WRINKLE GUARD, the End-ofCycle Signal will sound every 5 minutes.

3O

Follow these recommendations
to
help save on utility bills and prolong
the life of your garments.

PREPARING CLOTHES
FOR DRYING
• Refer to your Washer Owner's Manual
for proper washing techniques and
additional laundry tips.
• See page 4 of this book for Important
Safety Instructions.

SORTING CLOTHES

CHOOSINGLOADSIZES
• Mix large items with smaller items.
Load the dryer by the amount of space
items take up, net by their weight. Do
not overload the dryer, Overcrowding
causes uneven drying and wrinkling,
and can cause items to wear out faster
(because of pilling),
• You may need to rearrange large items
(sheets, blankets, tablecloths) during a
cycle to reduce bailing or rolling up.
• For better tumbling action, when drying
only a few small items, add one or two
lint-free towels. This also prevents
small lightweight items from blocking
airflow.

COMPACT DRYERS

• Separate dark colors from light colors;
colorfast from non-colorfast, Items
properly sorted by color for washing
are usually properly sorted for drying.
• Separate heavy fabrics (denim,
towels) from light fabrics (synthetics,
permanent press).
• Separate lint givers (towels, chenille)
from lint takers (corduroy, synthetics,
permanent press). When possible,
turn lint takers inside out.

Heavy Work
Clothes

PermaneRt

3 workshirts

-or-

2 pairs pants

2 double

Towels
9 bath towels
--

OF-

6 bath towels

Press

6 shirts

Mixed
Load
1 pair slacks

2 pillowcases

2 pillowcases
2 shirts

-or-

1 T-shirt

2 singie

sheets

sheets

Delicates

2 pillowcases

1 camisole

3 hand towels

Knits

2 slips

6 wash cloths

2 slacks

2 panties
2 bras

2 shirts
-or3 dresses

1 nightie
1 half-slip

31

DRYING TIPS

USING DRYER
FABRIC SOFTENERS
Dryer fabric softeners are recommended
for reducing static cling. Always follow
package instructions carefully.

• Close zippers, snaps, and hooks to
avoid snagging other items. Remove
heat-sensitive trim that can be damaged
by drying. Tie strings and sashes so
they will not tangle.
• Check garments for spots and stains
left after washing. Do not tumble these
items. Heat may permanently set stains.
• Check pockets before drying. Sharp or
metal objects can damage your dryer.
Do not lay these objects on your dryer;
they can damage the finish. Turn pockets
of heavy garments inside out for even
drying.
• Place small items such as baby socks
or hankies in laundry bag for easier
removal.
• Articles to be ironed should be
removed while still slightly damp.

32

• Put one fabric softener sheet on top
of the load before starting the dryer.
Do not add a fabric softener sheet after
the drying cycle has started. Instant
heat can cause the fabric softener to
spot fabrics.
• Remove fabric softener stains by wetting
the stains and rubbing them with liquid
detergent or bar soap and rewash.
• Some fabric softeners can clog the
lint screen and slow drying. Use fabric
softeners labeled as dryer safe.

SAVING ENERGY
• Use the AUTO DRY Cycle to dry
most loads.
• Dry full loads only. Do not overdry.
• Avoid overloading dryer, adding wet
items to a partly dried load, or opening
the door unnecessarily.
• Shorten drying times by exhausting
dryer properly and cleaning exhaust
vent and outside exhaust hood as
needed.
• Keep the lint screen clean.
• Use dryer where room air temperature
is above 45°F.
• Sort loads by fabric weight and type.

This section explains how to care for
your dryer properly and safely,

Proper care of your dryer can extend
its life and help you avoid costly
service calls.
EXTERIOR
Use a soft, damp cloth to clean the
cabinet and console. Avoid using harsh
abrasives. Do not put sharp metal objects
on or in your dryer. They can damage
the finish.
INTERIOR

Explosion Hazard
Use nonflammable cleaners.
Failure to do so can result in death,
explosion, or fire.
CLEANING

YOUR DRYER

To clean dryer drum:
STEP 1. Make a paste with detergent
and very warm water and apply to a soft
cloth. Continue with STEPS 2-4.
or

STEP la. Spray non-flammable liquid
household cleaner on the stained area.
Continue with STEPS 2-4.
STEP 2. Scrub area until all excess dye
is removed.

STEP 3. Wipe thoroughly with a
damp cloth.
STEP 4. Tumble a load of clean towels
for 20 minutes to dry.

Garments that contain unstable dyes,
such as denim blue jeans or brightly
colored cotton items, may discolor the
drum interior.

33

CLEANING

THE LINT SCREEN

Remove Lint Before Every Load
The lint screen is located on the back
wall of your dryer. Clean it before every
load. A screen blocked by lint can increase
drying time.
To clean:
STEP 1. Pull out the lint screen and its
cover.

IMPORTANT:
• Do not run the dryer with the lint screen
loose, damaged, blocked, or missing.
Doing so can cause overheating and
damage to both the dryer and fabrics.
• Some towels made of synthetic fibers
and natural fibers (polyester and cotton
blends) may shed more lint than other
towels, causing your dryer's lint screen
to fill up faster. Be sure to remove lint
from the lint screen before and after
drying new towels.
Wash Lint Screen As Needed
Laundry detergents and fabric softeners
can cause a residue buildup on the lint
screen. Wash the lint screen with a nylon
brush if it becomes clogged due to a
residue buildup.

STEP 2. Separate the cover and the
screen by squeezing the screen and
pulling on the cover at the same time.
Screen
/

/

Cover
/

To clean:
STEP 1. Wet both sides of lint screen
with hot water.
STEP 2. Wet a nylon brush with hot
water and liquid detergent; scrub lint
screen with the brush to remove
residue buildup.

STEP 3. Roll lint off the screen with your
fingers. Do not rinse or wash screen to
remove lint. Wet lint is hard to remove.
STEP 3, Rinse screen with hot water.
STEP 4. Thoroughly dry lint screen
with a clean towel; replace in dryer.

STEP 4. Put the lint screen and cover
back together and push firmly back into
place.

34

To remove accumulated
inside the dryer:

CHECKING FOR AIR FLOW
OBSTRUCTION

lint from

From time to time, you may find it helpful
to check your dryer and exhaust system
for proper air flow. Poor air flow can result
in longer drying times.
To check for air flow obstruction:
STEP 1. Check to ensure nothing is
blocking ventilation slots on dryer rear
panel.
STEP 2. Inspect exhaust hood. It should
not be blocked or obstructed.

REMOVING ACCUMULATED

LINT

Lint can gather inside the exhaust
vent or dryer and be fuel for a fire. Lint
should be removed every 2 to 3 years,
or more often, depending on dryer usage.
Cleaning should be done by a qualified
service person.
To remove accumulated lint from
exhaust vent:
STEP 1. Disconnect exhaust vent from
the dryer.
STEP 2. Clean one section of vent at a
time until your reach the exhaust hood.
To clean out lint, you can use the hose
attachment on your vacuum or, use
a pole or wire with a feather duster or
rag attached.
STEP 3. Reconnect vent as described in
the "INSTALLATION INSTRUCTIONS" of
this Owner's Manual.

Electrical Shock Hazard
Disconnect power before cleaning.
Replace all panels before operating.
Failure to follow these instructions
can result in death or electrical
shock,
STEP 1. Unplug the power supply cord
or turn off the electrical power supply.
STEP 2. Remove back panel by removing
the screws along the frame.

STEP 3. Remove lint from the dryer base
with a soft brush or vacuum cleaner. Avoid
damaging wires or electric thermostats.

U

STEP 4. Replace back panel; reconnect
and level dryer again, if necessary.
MOVING

CARE

• Unplug power supply cord or turn off
electrical power supply.
• Make sure leveling legs are secure in
dryer base.
• Use masking tape to secure dryer door.
VACATION

CARE

• Unplug power supply cord or turn off
electrical power supply.
• Wash lint screen.
35

Most laundering problems are easily
solved if you understand the cause.
Using these tables will save you time
and money by helping you avoid
unnecessary service calls.
Problem

Possible Cause

Solution

Not Drying

Lint screen is clogged with lint.

Clean lint screen.

Satisfactorily

Restricted air movement,
Exhaust vent or outside
exhaust hood is clogged
with lint.

Run dryer for 5_10 minutes. Hold
hand under outside exhaust hood to
check air movement, If you do not feel
air moving, clean exhaust system of
lint or replace exhaust vent with rigid
or flexible heavy metaI vent
(see "INSTALLATION','Section E).

Exhaust vent is crushed
or kinked,

Replace with rigid or flexible
heavy metal vent
(see "INSTALLATION','Section E).

One fuse is blown or circuit
breaker is tripped. The dryer
will appear to operate, but you
will not get any heat.

Replace fuse or reset breaker.

Timer or the temperature
control is set on AIR DRY.

Select the right cycle for the types
of garments being dried
(see "OPERATION").

Fabric softener sheets
blocking outlet grill,

Use only one softener sheet per load
and only use it once.

Dryer located in room with
temperature below 45°F,

Move dryer where it can operate in
ambient air temperatures above 45°F,

Large amount of moisture
in the load.

Expect longer dry times with items
that hold more moisture (cottons).

Cold rinse water used.

Expect longer dry times, but you are
saving energy and reducing wrinkles.

Load toe large and bulky to
dry quickly.

Separate load to tumble freely.

Power cord not firmly plugged
into a live circuit with proper
voltage.

Plug power cord into a live circuit.

Fuses blown or circuit
breakers tripped.

Replace fuses or reset breakers.

Dryer Will
Not Run

36

Problem

Possible Cause

Solution

Dryer Will

Using a regular fuse.

Replace with a time-delay fuse.

Not Run
(cont'd)

Dryer door not firmly closed.

Close dryer door tightly.

PUSH TO START Button
not firmly pressed.

Press PUSH TO START Button again.

Controls not set in an
ON position.

Reset controls in an ON position.

Lint screen is clogged.

Clean lint screen. Check for air
movement.

Improper sorting.

Sort lint givers from lint takers
and by color.

Load is too big or heavy.

Dry smaller loads so lint can be
carried to the lint screen.

Load is overdried.

Use correct dryer settings for fabric.
Overdrying can cause lint-attracting
static (see "OPERATION").

Paper or tissue in pockets.

Clean out pockets before drying.

Pilling being mistaken for lint.

Pilling (surface fuzz) is caused by
normal wear and laundering.

Improper use of fabric softener
in washer,

Use fabric softener sheets in dryer. Add
at beginning of cycle when load is cold.

Drying soiled items.

Items need to be clean before
being dried.

Overdrying.

Match dryer settings to fabric type
(see "OPERATION").

Poor garment quality.

Check quality of garment before
purchasing.

Manufacturer's care label
instructions not followed,

Follow fabric care label instructions
carefully.

Loads are

Overloading.

Dry smaller loads that can tumble freely.

Wrinkled

Overdrying.

Match dryer settings to fabric type
(see "OPERATION").

Load left in dryer at the
end of cycle.

Remove load as soon as tumbling
stops.

Household chemicals, paint,
or varnish being drawn
into dryer.

Do not use dryer while these chemical
fumes are in the air.

First use of dryer element
(electric only).

Will be gone after the first cycle.

Thumping of rollers when
dryer has set.

Thump will go away after 5 minutes
of drying.

Lint in Load

Stains on Load

Items
Shrinking

Odors

Unusual
Sounds

37

KENMORE DRYERS
"We Service What We Sell" is our
assurance that you can depend on Sears
for service. Your Kenmore Electric Dryer
has added value when you consider that
Sears has service units nationwide, staffed
with professional technicians specifically
trained on all appliances Sears sells. They
have the knowledge and skills, tools, parts,
and equipment to ensure our pledge to
you that "We Service What We Sell'.'
Sears Maintenance Agreement
Maintain the value of your Electric Dryer
with a Sears Maintenance Agreement,
Kenmore Electric Dryers are designed,
manufactured, and tested for years of
dependable operation, Yet any appliance
may require service from time to time,
The Sears Maintenance Agreement offers
you an outstanding service program for
your Kenmore Electric Dryer.

38

The Sears Maintenance Agreement
• Is your way to buy tomorrow's
service at today's prices.
• Eliminates repair bills resulting
from normal use.
• Allows for as many service calls
as required.
• Provides an annual Preventive
Maintenance Check at your request
to keep your Electric Dryer in proper
running condition.

For more information,
call 1-800-827-6655,

Forthe repair or replacement partsyou
need delivered directly to your home
Call 7 am - 7 pm, 7 days a week

1-800-366-PART
(1-800-366-7278)

For in-home major brand repair service
Call 24 hours a day, 7 days a week

1-800-4-REPAIR
(1-800-473-7247)

Forthe location of a Sears Partsand
Repair Center in your area
Call 24 hours a day, 7 days a week

1-800-488-1222

For informationon purchasinga Sears
Maintenance Agreement orto inquire
aboutan existingAgreement
Call 9 am - 5 pm, Monday - Saturday

1-800-827-6655
When requestingservice or ordering
parts, always givethe following
information:
• ProductName • Part Name
• Model Number • Part Number

SEARS
America'sRepairSpecialists

39



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 39
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Tue Apr 03 10:27:57 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu