Kenmore 36272296790 User Manual GAS RANGE Manuals And Guides L0707056

KENMORE Free Standing, Gas Manual L0707056 KENMORE Free Standing, Gas Owner's Manual, KENMORE Free Standing, Gas installation guides

User Manual: Kenmore 36272296790 36272296790 KENMORE GAS RANGE - Manuals and Guides View the owners manual for your KENMORE GAS RANGE #36272296790. Home:Kitchen Appliance Parts:Kenmore Parts:Kenmore GAS RANGE Manual

Open the PDF directly: View PDF PDF.
Page Count: 6

DownloadKenmore 36272296790 User Manual  GAS RANGE - Manuals And Guides L0707056
Open PDF In BrowserView PDF
SCHEMATIC

348A800_

DIAGRAM

_NLNG
POWER M__MU_S_T_BE
DIS C O N NEC T ED
BEFORE SERVICING THIS APPLIANCE

,M1
OLDOUTJ_I

It

Io

II

,),>

9v LP

LP

°
v

af_'d

lena

Lg%v

[I,10_

_

®

m

Lfr_

_lllltlll[

v
w
w

-__VL.r--_

COLOR
RED
VHITE
ORANGE
GREEN
YELLOV
VIOLET
BLUE
GRAY

LP ORIFICE

SPUD

348A: 800552R0. DWG

SYMBOL
R
v
0
O
Y
V
N
S

LOCATION

LP orifice spuds are located at the back of the storage/
broiler drawer compadment, The spuds are in a metal
bracket next to the pressure regulator and are
attatched to the back wall of the compartment by a
1/4" hex head screw. An LP conversion instruction
sheet is also located in this area

Gain Valve
Pressure

Regulator
Bracket

- LP Orifice

Spuds

,

WIRING DIAGRAM

348A8005

WARNING
POWER MU.$_T_B_D ISC O NN E CTE D
BEFORE SERVICING THIS APPLIANCE
RED
WHITE
ORANG[
GE"['N
YELLDV
VIOLET
BLUE
GRAY

R
V
0
G .....
Y
V
N
S

[LECxIW(

w)
v_v[

348A ',
800551RO, DWG
NUIE:

NOTE_

FOR SERVICEREPLACEMENT
ON ALL OIHER LEADS,
USE ]BGA. 150'C VIE EXCEPIAS INDIVIDUALLY
NOIED DN LEADS.

IGNITER (GLOWBAR}
REPLACEMENT
The Igniter/Glowbar and it's protective cage are now 2
parts The cage is riveted to the burner and is not
removeable
The Igniter can be removed as follows:
_Remove

the burner

* Bake

burner

-See

"Bake

6Remove

from

Burner

the oven,

Removal"

the 1/4" hex head

in this manual,

screw securing

the

igniter to the burner.
i Rernove old igniter.
_Handle
the new igniter
by the metal bracket only.
6Slide
new igniter into the cage and insert the tab on
the igniter bracket
4Re-install
6 Re-install

into the slot on the cage.

1/4" hex head screw to secure
the Burner

igniter

ALL
LEAD_
VITH
DESIGNAIION
NUMBERS
THAI
ENTER
COMMON
LEAD
TRACED

PATH
To

(

_

) MUST

IHE]R

TERMINATIONS.

BE

PO5I

CONVERSION
Burner

LF,LR
RF

1_44mm
1.65 mm

WB19KS066
.84 mm

WB28K0022

TO RAISE OR REMOVE COOKTOp
Remove burner caps and heads
6 Disengage 2 front clips using a flat biaded screw
driver as shown below
0 Lift top up at front.
FOR REMOVAL:
8 Disconnect electrode leads.
6 Disengage prop rods from range side panels
6 Lower top approximately 1/2 way down
6 Shift top left or right to disengage hinge pros at rear.

IMPORTANT:
clips,

position

burner
NOTE:

Before

openings
When

lowering

the burner

air/gas

the top onto
mixing

tubes

GAS

Depending on the model, remove Ibe storage
drawer, broiler drawer or false panel to access the
regulator. Some models with a broiler drawer will
have a metal cover over the regulator that must be
removed for conversion and reinstalled when conversion is complete.
T_
remove the Large hex nut which is located in the center of the regulator. Remove the
plastic pin from the bottom side of the cap, turn the
pin 180 degrees and snap the pin back into the
cap. There are raised letlers on the flat side of the
plastic pin, "NAT". and "LP". In the "LP" position
the end of the pin marked "NAT" should be snapped
into the bottom of the hex-nut.

the front
into the

in the cooktop.
re installing

top, position

top to be the

equivalent of 1/2 way lowered before attempting
insert the top hinge pins into the corresponding

to
slots

on the backguard

LOW FLAME

TO LP (PROPANE)

1Convert Regulator - ReguJator is located in the
lower, left hand rear corner of the range as viewed
from the front.

ISIMMER)

ADJUSTMENT

The top burner valves have low flamefsimrner adjustment screws in the center of the control valve shafts.
A flashlight may be required to locate the screw. A
thin, flat bladed screwdriver (approx 3/32" across) =s
needed to access the screw
To Adjust The Low Flame Settino - At least 2 other
surface burners must be lit. Then, late the burner be
ing adjusted and turn knob to "LOW" Remove knob
and insert the screwdriver into the valve shaft Turn
the adjustment screw until the flame reaches the de
sired size,

Lever Shown"CLOSED"
PULL "OPEN"
2. Remove surface burners and replace all 4 top burner
orifices spuds with the LP orifice spuds supplied
with the range. (See chart on column 1 of this sheet
for orifice location and orifice indentifying marks).
3.Using a 1/2" wrench, tighten the orifice hood(s)
supplying gas to the oven burner(s) clockwise until
snug.
4.Open the air shutter on the oven burner(s) to the
full open position and adjust as needed.
5.Adjust the low flame (simmer) setting on the surface burners as described under "LOW FLAME
(SIMMER) ADJUSTMENTS".
SPARK

Ballast

Test The Flame Stability
Test 1: Turn the knob from "HI" to "LOW" quickly. If
the flame goes out, increase the flame size and test
again
Test 2: With burner on "LOW" setting, open and close
the oven door quickly. If the flame is extinguished by
the air currents created by the door movemenl, increase the flame height and test again.

MODULE

LOCATION

The spark module is located inside the backguard as
shown below. The module is mounted by Two tabs
which snap into corresponding slots
To remove the module from its mounting, use a small,
flat bladed screwdriver to bend the mounting tab toward the module body, freeincl the tabs from their slots.
Models with a flourescent lamp (11" backguards) will
have the ballast mounted in the backguard, opposite
the spark module.
Spark

Module

Slots

NOTICE
THIS INFORMATION
IS INTENDED FOR USE BY INDIVIDULS POSSESSING ADEQUATE BACKGROUNDS
OF ELECEXPREIENCE,
NY ATTEMPT TO REPAIR A MAJOR APPLIANCE
MAY
RESULT IN PERSONAL INJURY AND PROPERTY DAMAGE
THE MANUAFACTURER
OF SELLER CANNOT BE RESPONSIBLE FOR THE INTERPRETATION
OF THIS INFROMATION,
NOR CAN IT ASSUME ANY LIABILITY
IN CONNECTION
WITH ITS USE.

I! RICAL, ELECTRONIC
IMPORTANT AND
SAFETY
MECHANICAL

SPILL-PROOF SEALED/GOURMET)
Burner Construction

BURNER

CAP

DISCONNECT
POWER BEFORE SERVICING
IMPORTANT - RECONNECT ALL
GROUNDING DEVICES,
ALL PARTS OF THIS APPLIANCE CAPABLE OF CONDUCT*
rNG ELECTRICAL CURRENT ARE GROUNDED. IF GROUNDING WIRES, SCREWS, STRAPS, NUTS OR WASHERS USED
1"O COMPLETE A PATH TO GROUND ARE REMOVED FOR
SERVICE, THEY MUST BE RETURNED TO THEIR ORIGINAL
POSITION AND PROPERLY FASTENED.

Burner

Output

Rating:BTU/HR

TOP BURNER ORIFICE REMOVAL
The top burner orifices can be removed by removing
the burner caps and burner heads. Use a 7 millimeter
nutdnver to access the orifice through the burner air/
gas mixer tube, *
NOTE: ]he orifices have spring loaded retaining rings
around the hex head to hold the orifice in the nutdirver
during installation and removal. A slight amount of
force is required to push the nutdriver down over the
ring.

HEAD

RETAINER
RING
* A 9/32" nuldriver may be
used by will have a loose fit
BN_L___._R_L[_
R

AIR/_

CLIP

For proper

N M ENT

operation

the orifice holder,
be correct.
The alignment

(C MNEY)

nutdriver
nudriver

I'_I_ORIRCE

should

_Ii'Of_RCE

HOLDER

can be made

stand
angle

mixer tube

by placing

to exaggerate

straight

by carefully

the alignment

and air/gas

can be checked

over the orifice

and gas injection

16,000

of the burner,

orifice

indicating

is correct.
bending

Angle

of
must

a 7 mm *

the angle.

The

the alignment
adjustments

the supply

tube.

Ben_,orleTS5Nmt_tOarl,_,ze
op,n,nQ

The burner components beneath the range top rely on
spring tension to hold them in place The spring
pushes the air/gas mixer tube up against the bottom of
the range top. A flange around the airgas mixer tube
body is the mating surface between the range top and
the air/gas mixer tube, This mating surface serves
several purposes:
• It keeps the alignment of the air/gas mixer tube
straight so the gas is injected straight into the
burner.
6 It serves as an electrical grounding path, grounding
the burner head to the range, which serves as part
of the spark electrode circuit,

TOP BURNER ORIFICE IDENTIFICATION
A series of marks (I, II or III) are engraved on the
tops of the orifices to denote the location of the
orifice as shown in the illustration,
The marks apprear on both the LP and Natural Gas
onfices. The locations indeicated by the marks are
the same for both gasses

LP ORIFICE

COLOR

CODE

IDENTIFIER_

To aid in identifiying the proper location for the LP
orifices durinq a conversion from Natural Gas to LP
Gas, paint color codes have been added to the
side of the orifice. See the chart below,

White

{

\

TOP BURNER FLAME ADJUSTMF_NJ$.
The top burners do not have air shutters and fixed, non
adjustable orifices are used. if the flames blow off the
burner or have yellow tips, check the following:
6 Gas pressure: 4" Natural gas - 10" LP gas.
Inspect orifice to be sure it is drilled on center and
free of debris or burrs.
I Be sure the correct size orifice is in the proper
location (see "Orifice Iduiflil_ualiuH" SeL:tiUll or IIIis
sheet).
• Make sure range was p[operly converted if on LP gas
• Check the burner alignment per the "Burner Align
merit" section of this sheet.
ill If cause cannot be found in the above checks,
replace the orifice with one having a smaller diameter
opening as listed on the next column

OVEN TEMPERATURE

CALIBRATION

NOTE: Calibration adjustments are made by moving the knob skirt. DO NOT make any adjustments
to the thermostat itself.
IMPORTANT:

Before

making

Horizontal Alignment - Horizontal alignment of the door
is accomplished
by adding a shim, part number
WB02X3193. to the top of the hinge to raise the door by
approximately 1/16". Use only 1 shim per hinge.

any temperature

adjustments,
be sure the oven thermostat
capillary bulb is properly
positioned
in the bulb

Front of

mounting clips, If capillary bulb is out of position
and contacts oven wall, calibration will be incorrect. An unusually dirty capillary
affect thermostat
calibration,
TO ADJUST
(As covered

Range

bulb will also

_

KNOB:

tMo
C;l: ttUpp: peSnCi
nre_._

in the Use and Care Manual)


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 6
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Thu Jul 19 02:58:57 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu