GAS.FIRED

Sears

FORCED AIR
WALL FURNACE

@
.Installation
.Operation
• Repair Parts

FOR YOUR SAFETY
Do not store
other flammable
the vicinity
of
appliance.

or use gasoline
or
vapors and liquids in
this or any other

FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don't touch electrical
switches.
3. Extinguish
any open flame.
4. Immediately
call your gas supplier.

Sears, Roebuck and Co., Chicago, II. 60684
PRINTED

IN

U.S.A.

U.S.A.

Contents
Introduction
...................................
Sears Warranty ................................
Sears Installation
Policy ........................
Sears Installation
Warranty
.....................
safety Rules .................................
Basic Tools Needed ............................
Basic Materials
................................
Optional Accessories ...........................
Furnace Data ..................................

4
4

Unpack Your Furnace
..........................
Installation
Steps ..............................
Locating Furnace ..............................
Combustion Air ..............................
_'-*_l

I

Installation
Surface Mount Installation.................. 6-9
Recessed Installation
.................. ,...9-13
Connecting Gas Line .......................... 13
Electrical
Wiring .............................. 14
Thermostat Installati
on ........................ 14
Checks and Adjustment._ .................... 14,15
Lighting ..................................... 16
How To Use Your Furnace ...................... 16
How To Care For Your Furnace."................. 17
SERVICE HINTS ............................... 17
Wiring Diagram .............................. 18
Repair Parts ............................... 19-27

2
2
2
2
2-3
3
3

4
5
5
; .5

IIIIIIIIIIIIIIIIIIIII

.............

IIIIUIIIIIIIIIIII
I

IIIIIIIIIIIIIIIIII
III
I'IIIIIIIIIIIIIIIIIIII
I
I

,ntroduction
Please read our instructions
before you install and use your furnace. This will help you obtain
this furnace. It will also help you avoid any needless service costs, if the problem is something
and cann°tc°ver
in our Warranty.

-

FULL ONE YEAR WARRANTY

i

I _II

ON SEARS WALL FURNACE

JJ

For one year from the date of purchase, when thisfurnace is installedand maintained in
accordance -withour instructions,
Sears willrepair defects in material or workmanship
in
of charge,
l theI lfurnace,
IIB IIIfree I Iml
I Im Mil
lllii
I l
I Hi lliI
I l
Il
I _III II
lie I l
I l
I I

LIMITED WARRANTY
!

After
one year
through
rep]acement
Heatand
Exchanger,

This warranty

and you may also have other

rights

which vary from

II
.

BSC 41-3, Sears Tower
Chicago, Illinois 60684
I i

! a

I Im

.1

len
the date
purchase,
Sears willYou
furnish
if theyears
Heat from
Exchanger
in theof furnace
is defective.
pay fora

gives you specific legal rights,

I aim I Hi

I _ a

II

Sears, Roebuck

I miD I i

i I

ON HEAT EXCHANGER

! ,o,,ote
1_lil

the full value from
we cannot control

I Nil

i am

III

It I

i III

Ill

I l

I imami I

I i

=,

state

I

-I.

and Co.

I

! mam H am

I am

l:ll'iiil

_

To function properly, your furnace must be installed correctly. You must know how tO Us_the tools:ilOlDd;eq_ipment
and understand electrical wiring and potential hazards. If there is any doubt we ask thaf;_ou
contact your Sears
Salesman. He will arrange for professional installation.
I ill I ill
i
I I
II
I m IJI
l i
I IJ I I
l Ill I l
!I
! n 11m ! Ill I ImI I IJm I I
I Ill IIE
I I
I I
i i

n

SEARSlNSTA"ATION
POUCY i SEARSINSTA"ATION
WARRANTY
n

ALl installation
labor arranged by Sears shall be
I performed
in a neat,
workmanlike
manner
in
,= accordance withgenerallyacceptedtrade
practices.
J Further, ai[ installations
shall comply with all local
.= laws,
codes,
regulations,
and ordinances,
The

"_.
I
_
I
"

In addition to any warranty
extended to you on the
Sears merchandise
involved,
which
warranty
be-I
comes
effective
the date
the
merchandise
is
installed,
should the workmanship
of any Sears
arranged installation prove faulty within one year,

:

be corrected

,,,
=
I
_"

! customer
sha.also
beprotected
du.ng
insta,,ation,
I Sears upon
ootice
from
you.
cause
such
faults
toI!
m

by insurance

i men's

relating

Compensation
IIIIIIIIiIIIIIIlllllIII

to Property

Damage,

Work-

and Public Liability.
If[fill

_ll

at no additional

cost to you.
I

IIilIIIIIIIlilIIIIIIIlil

II'IIIIIIIIIIIIIIII
I

Safety Rules
with local codes and ordinances
or, in their
'absence
with the National Fuel Gas Code,
ANSI Z223.I-1974.

1. Read these rules and the instructions
carefully.
Failure to follow
these rules and instructions
could cause a malfunction
of the furnace.
This
could result
in death,
serious
and!or property damage.
2. This furnace

must be installed

bodily

injury,

in accordance

2

3.

Do not install

this furnace

in an alcove.

4.

Do not install this furnace
in a mobile
trailer or recreational
vehicle.

home,

5. Maintainall clearancesspecifiedon page5,
LocatingTheFurnace.
6. Be sure furnaceis equippedfor type of gas
(Naturalor LP)to be used.Checkthe rating
plate.
7. Gassupplypressuretothefurnacecontrolvalve
must be at least 5 incheswater columnfor
Natural gas and 11 inches,watercolumnfor
LPgas.It mustnot be morethan14inches,

working
on it. This will
shocks or burns.

any

electrical

12. Due to high temperatures,
be located out of traffic
and draperies.

13. Children

and adults

the furnace should
and away from furniture

should

be alerted

to

the

hazards of high surface temperature
and should
be kept away to avoiTJ"!_urns or clothing ignition.
14. Young children
should be carefully
supervised
when they are in the same room with
the
furnace.

8. Thefurnacemustbeventedto the outdoorsso
that harmfulgaseswill not collectinsidethe
building. Follow the venting instructionsfor

15. Do not
material

your type installation
exactly. Use only the type
and size of vent pipe and fittings specified.

place clothing
or
on or near furnace.

other

flammable

16. Installation

and repair should be done by a
qualified service person. The furnace should be
!nspected before use and at least annually by a
professional
service person. More frequent
cleaning may be required due to excessive lint
from carpeting, bedding material,
etc. it is
i-mperative that control compartments, burners,
and circgiafing a!r passage ways of the furnace
be kept clean.

9. Be sure to provide
enough
combustion
and
ventilation
air. See page 5. The flow of this air
to the furnace must not be blocked.
10. Never test for gas leaks with an open flame. Use
soap suds to check all gas connections.
This will
avoid the possibility
of fire or explosion.
11. Before servicing,
allow furnace to cool. Always
shut off electricity
and gas to furnace
when
IIIII

prevent

IIIIIIIIIl_llllllllUII
_

I

Basic Tools Needed
Hand drill or properly grounded electric drill
Expansion bit 7/8" to 1-5/8"
3/32" drill bit (metal)
6 ft. folding rule or tape
Screwdrivers
Pliers (wire cutting)
Hammer
I II]1

III

I

I

Tin Snips
8" adjustable
wrench
12" adjustable
wrench
Key hole saw
Hack'saw
2 - 10" or 12" pipe wrenches
Gloves
IIIIIIIIIIIIIIIIIIIIIIII II III

I

Basic Materials
Black iron
connections

or steel
pipe and fittings
from gas meter to furnace.

to

Sears Stock No. 42-99767 gas vent kit for vertical
venting or Sears Horizontal Vent Kit, Stock No.
42-7369 for Horizontal venting.

make

Pipe joint compound
Electrical

wiring

supplies as needed

Extra lengths of round, double wall vent pipe may be
needed. You must use 4 inch pipe for vertical venting
and 5 inch pipe for horizontal venting,
it must be
Type B-1 vent (listed by Underwriters
Laboratories
for Type B installation
at 1 inch clearance
.to
combustible
materials).

(See page 14).

Vent Shield Kit, Sears Stock No. 42-7311, if furnace is
to be mounted
on a wall surface (not recessed
in
wall).

I

Helpful Information
The following

booklets

will help you in makingthe

installation.

Available at Sears from the Plumbing, Heating or
Electrical Departments at nominal cost:

American
Fuel Gas

Do It Yourself Plumbing Handbook

Obtain
fromInstitute,
Inc.,
10018,

Basic Wiring

3

National
Code".

Standard

Z223.1-1974

American
National
1430 Broadway,
New

"National

Standards
York, N.Y.

Optional

Accessories

1. Tall Register Kit, Sears Stock No. 42-7312, For use
when replacing
a "Dual
Wail"
furnace.
Tall
register covers existing walt opening.

3. Vent Shield
Kit, Sears
required when mounting
face of the wall.

2. Shot;r Rear Wall Register Kit, Sears
42-7313.
For use when
installing
heating but not replacing "Dual Wall"

4. Horizontal
Vent Kit, Sears stock No, 42-7369 is
required
if furnace
;s to be vented horizontally
into on existing chimney.

I .

I

IIIIIIIIIII

I II

Stock No.
two-room
furnace,
IIIIIIIIIIIIIJ

II I

IIIIIIIIIIIIIIIII

IIIIIIIIIIIII

II

IIIII/11]

Stock No.
the furnace

IIIIIIIIII

I

42-7311.
is
on the sur-

IIIIIIIllll

IIIIIIII

Furnace Data
TYPE
GAS

MODEL
NUMBER
....867.736349

Nat.
L,P.*

867.736389
*Liquefied

:

INPUT**
RATING
Btuh***

MAIN

BURNER ORIFICE
2 REQUIRED
DRILL
DEC.

65,000
65,000

...... 36

.1o65"

52

.0655"

PILOT ORIFICE
DECIMAL
.018"
.010"

Petroleum.

**For elevations
***Btuh
= British

above 2000 ft. reduce ratings
Thermal Units per hour.

4% for each 1000 ft. above

sea level.

BE SURE YOUR FURNACE IS EQUIPPED FOR THE TYPE OF GAS TO BE USED, EITHER NATU_,AL OR L.P. GA,5. THE
CONNECTIONS FROM THE L.P. BULK STOlYAGE TANK TO THE FURNACE CAN ONLY BE MADE BY A LICENSED
L.P. DEALER.
I

......................................................

__..I

"

L

-

i

!---=------':

Unpack Your Furnace
The shipping
carton contains the furnace
following
items needed to install it.
1, Thermostat
and wire
cabinet door (Fig. 1).

--

2. Top trim piece and small
inside end of carton.

parts

3. Vent support assembly -end of furnace.
where

packed

and the

inside

bag --

lower

taped

to

t' [.
Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 29
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 4, 0, 0, 13
Create Date                     : Sun Apr 26 04:17:56 2009
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu