Keston Frame And Header Kits Installation Manual
Keston frame and header kits manual 2013 Keston frame and header kits manual 2013
2015-05-15
: Keston Keston-Frame-And-Header-Kits-Installation-Manual-719671 keston-frame-and-header-kits-installation-manual-719671 keston pdf
Open the PDF directly: View PDF .
Page Count: 20
Download | |
Open PDF In Browser | View PDF |
FRAME & HEADER KIT INSTRUCTIONS Keston Heat 45 Keston Heat 55 Keston Heating PO Box 103, National Avenue, Kingston Upon Hull, HU5 4JN Tel. +44 (0) 1482 443005 Fax. +44 (0) 1482 467133 email : info@keston.co.uk web : www.keston.co.uk This kit is suitable for the following boilers: Keston Heat 45 & 55 Contents 1 Introduction and General Description...........................3 2 General Description of Cascade System......................4 3 Multiple Boiler System Components.............................5 4 Installation Drawings for Multiple Boiler Systems.......8 5 Wall Mounted Installation Procedure.......................... 11 6 Frame Kit Installation Procedure.................................13 7 Header Kit Assembly.....................................................14 8 Electrical Connections..................................................17 9 Commissioning and Testing.........................................17 2 Keston Heat - Frame & Header Kits 1 Introduction This technical data contains information for dimensioning & assembly of a cascade system kit for the Keston Heat range of products. Header and Frame kits are available in line (from 2 to 6 boilers long). General Description of Frame & Header kits A requirement to spread the total required heat output over several boilers can be accommodated by the use of the Keston Heat multiple boiler frame & header kit options. An optional sequencer kit can be specified to switch boilers in cascade on or off dependent on total heat demand. Keston Heat - Frame & Header Kits 3 2 General Description of Cascade Systems 2.1 Frame and header Kit Design Options The Keston Heat boilers are suitable for use in a multiple boiler configuration. The multiple boiler system is available as a wall or frame mounted side by side configuration with the use of the relevant frame / header kits. This gives opportunity to choose the optimum footprint size or wall space for a given output. The table below states options available and gives the minimum number of appliances required, the appropriate floor space & the kit product number (N.B. The kits do not include the boilers). Side by side kits do not include the support frame as the boilers can be wall mounted but a frame kit is available if wall space etc. does not facilitate boiler/header wall mounting. Flue configuration for the appliance is C53 and C13 only (see appliance manual). Frame and Header Kit System Design Options Total Output Required Kw 90 100 110 135 145 155 165 180 190 200 210 220 225 235 245 255 265 275 280 290 300 310 320 330 Side By Side Option – Number Of Boilers/Output Required 2 x 45 1 x 45 - 1 x 55 2 x 55 3 x 45 1 x 55 - 2 x 45 2 x 55 - 1 x 45 3 x 55 4 x 45 1 x 55 - 3 x 45 2 x 55 - 2 x 45 3 x 55 - 1 x 45 4 x 55 5 x 45 1 x 55 - 4 x 45 2 x 55 - 3 x 45 3 x 55 - 2 x 45 4 x 55 - 1 x 45 5 x 55 1 x 55 - 5 x 45 2 x 55 - 4 x 45 3 x 55 - 3 x 45 4 x 55 - 2 x 45 5 x 55 - 1 x 45 6 x 55 In line frame kit Header Low Loss DN80 Kit 4 Side by Side Header Kit Footprint Size Product No. W x D (mm) Side By Side 1500x560 1500x560 1500x560 2055x560 2055x560 2055x560 2055x560 2600x560 2600x560 2600x560 2600x560 2600x560 3150x560 3150x560 3150x560 3150x560 3150x560 3150x560 3700x560 3700x560 3700x560 3700x560 3700x560 3700x560 355014 355014 355014 355015 355015 355015 355015 355016 355016 355016 355016 355016 355017 355017 355017 355017 355017 355017 355018 355018 355018 355018 355018 355018 355013 355019 Keston Heat - Frame & Header Kits 2.2 Multiple boiler Installations For installing 2 to 6 boilers, the product range includes water and gas headers capable of assembly using threaded socket,compression and flange connections. 2.3 Hydraulic isolation: Mixing header (Header Kits include a low loss mixing header) A low loss header allows flow separation within a hydronic system. This essentially creates linked stand alone flow circuits with their own flow rates and pressure drops. Allowing for the modern high resistant high efficiency boilers to operate under their optimum conditions, while the main heating circuit operates to its own controlled optimum requirements. 2.4 Output control An optional sequencer kit is available to maximise the efficiency of a multiple boiler installation. Instructions for installation and use are contained in the sequencer kit. The sequencer kit facilitates control of up to five boilers in cascade. 2.5 Gas Supply The 45-55kW boilers are suitable for use with natural gas. Connect the boilers to the gas mains in accordance with the applicable regulations The gas header connection is a 2” female thread with test points at each end. It is the test point nearest the inlet of the group of appliances that becomes the appliance inlet pressure point. Refer to the boiler Installation & Servicing Instructions for general GAS SUPPLY details. 2.6 Assembly The frames and headers must stand on a flat and level floor of suitable load bearing capacity. 2.7 Safe Handling This boiler may require 2 or more operatives to move it to its installation site, remove it from its packaging base and during movement into its installation location. Manoeuvring the boiler may include the use of a sack truck and involve lifting, pushing and pulling. Caution should be exercised during these operations. Operatives should be knowledgeable in handling techniques when performing these tasks and the following precautions should be considered: • Grip the boiler at the base. • Be physically capable. • Use personal protective equipment as appropriate, e.g. gloves, safety footwear. During all manoeuvres and handling actions, every attempt should be made to ensure the following unless unavoidable and/or the weight is light. • Keep back straight. • Avoid twisting at the waist. • Avoid upper body/top heavy bending. • Always grip with the palm of the hand. • Use designated hand holds. • Keep load as close to the body as possible. • Always use assistance if required. 3 Multiple boiler system components 3.1 General The multiple boiler systems consist of the following components: • Frame kit. (Optional only with In-line kits) • Boiler gas header. • Boiler flow and return headers supported on mounting skid • Low loss mixing header • Hardware packs (includes essential connection and valve components) 3.2 Main Water headers The main water headers consist of: insulated water flow, insulated water return headers custom sized for all boilers. It is possible to extend the system to a maximum of 6 boilers in a linear configuration.Each header kit provides water flow and return headers sized either DN80 or DN100 dependent on total maximum combined heating output required. Keston Heat - Frame & Header Kits 5 3.3 Gas header The Gas header consists of a custom manufactured 2” manifold. This is located in a cradle incorporated within the header mounting skid. 3.4 Mixing header The mixing headers are insulated and are supplied with an auto air vent and drain point as standard. 3.5 Boiler connection kits Legend 1. 11/4" x 3/4" x 11/4" Tee 2. Close Taper Nipple 3. Safety Relief Valve 6 bar 4. Isolation Valve 5. 11/4" x 1/2" x 11/4" Tee 6. Drain Off Cock 7. Connection Pipe Assembly 8. Non Return Valve 9. 11/4" Taper Male to 11/4" Parallel Hex Adapter 10. Boiler Flow Flexible Connection from Header 11. Boiler Return Flexible Connection from Header 7 Items 1,2,3,4,5 & 6 are supplied with the boiler. (AL-208973 Isolation Valve Kit) Items 7, 8 & 9 are supplied with the Header Kit Items 10 & 11 are pre-assembled to the water header. Assemble fittings together as shown using appropriate sealing material. Do not fit the safety relief valve (item 3) at this stage. When assemblies are complete fit to boiler flow and return stubs with suitable sealing material. The safety valve (item 3) can now be fitted using suitable sealing material. Ensure all isolation valves, pressure relief valves and drain valves are fitted to allow unrestricted operation. 3.6 Free-standing frames If boilers in cascade are positioned in-line the installer has the option to either wall mount the boilers or mount boilers on optional frame kits available. If mounting in-line product on frames, optional frame kit UIN 355013 must be specified in the correct quantity, one frame kit for each boiler installed in cascade. 3.7 Installation area and Dimensions Care must be taken to ensure adequate access for boiler / cascade system installation and servicing. A minimum of 450mm must be provided from the front of the installed boilers in cascade to facilitate boiler servicing. Consideration to connecting heating flow and return pipework, gas supply and condensate drainage must be given. Routing of the condensate drain must be made to allow a minimum fall of 1 in 20 away from the installed boilers in cascade, throughout its length. Adequate room above the boilers must be provided to install and service the boiler flue system. Further information with respect to flue and condensate drain connection is provided in the installation and servicing instructions provided within the boilers packaging carton. 6 Keston Heat - Frame & Header Kits IMPORTANT POiNTS Before commencing installation: If Wall mounting; • Ensure wall is capable of supporting the weight of boilers to be mounted • Mark drill points of header using floor mounting template • Mark height on to the wall from the floor to the top of the boiler • Ensure floor is flat and level and is of suitable load bearing capacity If Frame mounting; • The frames must stand on a flat and level floor of suitable load bearing capacity. • If using a frame kit (UIN 355013) the header must be bolted to the frame before the hoses are connected to the boiler. These Installations refer to perpendicular wall and floor. If walls are not perpendicular, it is recommended that a frame kit be used (UIN 355013). The correct number of frames should be ordered (1 per boiler). Allowances must be made for installation where skirting boards or other features are in place that may affect the nominal installation conditions. Keston Heat - Frame & Header Kits 7 4 Installation drawings for Multiple boileR SYSTEMS 4.1 General The multiple boiler systems are available in two formats: • 2 to 6 boilers in a linear configuration, mounted on a wall. • 2 to 6 boilers in a linear configuration, mounted on free-standing frames. The boiler side of the cascade systems is sized to give a water flow and return differential 20ºC. 4.2 sIDE BY sIDE fRAME kIT cONFIGURATION 4.2.1 iNSTALLATION dRAWING WITH 2 - 45 or 55 bOILERS (sIDE BY sIDE) Side by side wall or frame mounting dimensions 8 Keston Heat - Frame & Header Kits 4.2.2 iNSTALLATION dRAWING WITH 3 - 45 or 55 bOILERS (sIDE BY sIDE) Side by side wall or frame mounting dimensions Keston Heat - Frame & Header Kits 9 4.2.3 iNSTALLATION dRAWING WITH 4 - 45 or 55 bOILERS (sIDE BY sIDE) Side by side wall or frame mounting dimensions 10 Keston Heat - Frame & Header Kits 4.2.4 iNSTALLATION dRAWING WITH 5 - 45 or 55 bOILERS (sIDE BY sIDE) Side by side wall or frame mounting dimensions Keston Heat - Frame & Header Kits 11 4.2.5 iNSTALLATION dRAWING WITH 6 - 45 or 55 bOILERS (sIDE BY sIDE) Side by side wall or frame mounting dimensions 12 Keston Heat - Frame & Header Kits 5 Wall Mounted Installation procedure 5.1 Wall mounted side by side option Ensure wall is capable of supporting the weight of boilers to be mounted. Note. boiler weights can found in the boiler Installation Instructions. 1. Cut the sides off the cardboard wall mounting template/s (found in the boiler packaging) to create the 50mm side clearance required. 4. Drill the required holes in the wall to fit the wall mounting plate plugs. (See boiler Installation Instructions for details) 2. Mark the height on to the wall from the floor to the top of the boiler 1919mm. 2 4 1 5. Screw the wall mounting plate(s) to the wall. 5 3. Tape the template/s to the wall ensuring the 50mm side clearance per boiler requirement is adhered to. Floor Mounting: Align centre line of template to centre line of boiler and drill holes for headers. 3 continued . . . . . Keston Heat - Frame & Header Kits 13 5.1 Wall mounted side by side option cont'd............ SIDE VIEW PLAN VIEW Careful consideration MUST be given to the installation tolerances. If these are not adhered to, hoses may become kinked or connections may not fit. Bolt header to floor using template provided (front fixings only). Connect up hoses (see page 15) 14 Keston Heat - Frame & Header Kits 6 Frame Kit Installation Procedure 6.1 Side by side Frame kit mounting procedure 1. Place the frame kit sections in the required position and bolt them together at the top and bottom with the bolts, nuts and washers provided. 1 2 Keston Heat - Frame & Header Kits 2. If additional stability is required remove the plastic foot covers and drill the floor. Then bolt the frame to the floor using suitable bots and fixings (bolts not supplied). 15 6.2 Boiler mounting 1. As appropriate mount the boilers onto either the wall plates or the side by side frame kit. 1 2. Ensure the two boiler bottom fixing brackets are screwed to the frame or wall. 2 7 Header kit assembly 7.1 Fitting mixing header and blanking flanges 1. Fit the mixing header and blanking flanges in the chosen positions, with the bolts, washers and seals supplied. Note. Mixing header can be located either LHS or RHS of the headers. Mixing Header 16 Blanking Flange Keston Heat - Frame & Header Kits 7.2 Fitting header kit assembly 1. Slide the header kit assembly between the frame legs but do not screw the header kit to the frame at this stage. 1 2. Screw the header legs to the frame feet with the bolts, nuts & washers provided. Tighten nuts after the flexible hoses have been fitted to the boiler. 2 3. Fit the two flexible header connections to the boiler flow and return connections ensuring the sealing washers are fitted. Keston Heat - Frame & Header Kits 17 7.3 Fitting gas connection 1. Fit the gas isolation valve assembly supplied with the boiler to the boiler gas connection ensuring the sealing washer is fitted. 1 2. Fit the copper gas pipe provided in the header kit to the isolating valve and the header gas connection using 22mm compression fittings provided. 2 2 7.4 Pressure relief valve connection 7.5 Condensate Trap fitting 1. Ensure each boiler pressure relief connection is piped to a safe discharge point. 1. Fit the condensate trap to the boiler and pipe to drain following the recommendations contained in the boiler Installation instructions. 1 1 18 Keston Heat - Frame & Header Kits 8 Electrical Connections Refer to the Installer Wiring Connection section in the boiler Installation Instructions for wiring details. 9 commissioning and testing Electrical and gas safety checks must be carried out on completion of installation as with individual boiler commissioning. Keston Heat - Frame & Header Kits 19 Keston Heating, PO Box 103, National Avenue, Kingston Upon Hull, HU5 4JN Tel. +44 (0) 1482 443005 Fax. +44 (0) 1482 467133. www.keston.co.uk June 2013 UIN 209785 A01 Keston pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2013:06:10 13:50:48+01:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2013:06:10 13:55:19+01:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2013:06:10 13:55:19+01:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:0946fcae-78b1-4046-9fb8-37e0ba272857 Original Document ID : xmp.did:E39588C0D5F0DF11AA88CD193C55CEE6 Document ID : xmp.id:D5043F60CCD1E21199E9BB0C93CD2BC7 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:02A2A663CAD1E211B036D23ED347156A Derived From Document ID : xmp.did:0576F21E29C1E211B4D5922D881108CD Derived From Original Document ID: xmp.did:E39588C0D5F0DF11AA88CD193C55CEE6 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2013:06:10 13:50:49+01:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 20EXIF Metadata provided by EXIF.tools