Keymat Technology DS40 AXS Series S40 iClass SE PIN-Contactless Reader User Manual Engineering Manual
Keymat Technology Ltd AXS Series S40 iClass SE PIN-Contactless Reader Engineering Manual
Contents
- 1. Engineering Manual
- 2. Datasheet
Engineering Manual
Engineering Manual for AXS Series S40/S40i Keypad AXS SERIES S40 iCLASS SE® PIN-Contactless Reader: This integrated keypad and contactless reader is rated for continuous outdoor use in exposed, unsupervised locations. Featuring genuine HID™ iCLASS SE®, Seos®, contactless technology, this access control keypad offers enhanced security by dual factor authentication. Authorized access through a secured door or barrier can be gained by entry of a valid PIN and/or presentation of an authorized 13.56 MHz contactless card, token or Seos® device This manual covers the S40 and S40i, and is available from www.storm-interface.com/downloads. Each individual product includes a printed datasheet with just the essential information for installation. Table of Contents Product Range and Accessories/Options Supported Credentials Keypad Installation Wiegand Formats Typical Wiring (Kantech KT-300 Controller) Specifications/Regulatory Whilst every effort is made to ensure details are correct at time of print, specifications are subject to change without notice. Storm Interface products include technology protected by international patent and design registration. Storm and Storm Interface are trademarks of Keymat Technology Ltd. Storm Interface is an ISO9001 registered company.Storm is a trading name of KeymatTechnology Ltd S40/S40i Engineering Manual Rev 1 April 2015 Page 1 of 5 www.storm-interface.com © Copyright Storm Interface. 2015. All rights reserved Engineering Manual for AXS Series S40/S40i Keypad Product Range Two products are included in the range. The S40, which has a metal keypad, and the S40i, which has an illuminated white polymer keypad. Both products can be powered via the 5V or 12V supply pins. However, the illumination will only function when powered from 12V Options A privacy shield (p/n 1KFS020) is available as an optional extra Please see the Storm website at www.storm-interface.com Supported Credentials The following credentials are supported (additional controller set-up may be required): iClass Seos MiFare Classic MiFare Plus MiFare Ultralight DESFire 0.6 DESFire EV1 Installation Connection to the Controller is via a 12-way connector. The connector is removable to ease wiring. Recommended locations and wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70. Connections are as follows: Pin A – Pin B – Pin C – Pin D – Pin E – Pin F – Pin G – Pin H – Pin I – Pin J – Pin K – Pin L – 5V power input – 5V at 200mA Beeper input. Active low, pulled up internally. Beep sounds when this pin is set low Card data hold. Active low, pulled up internally. Set low to hold card data transmission Tamper output. Connects to 0V when the tamper switch is closed, and is open circuit on a tamper 0V power and signal return 0V power and signal return RED LED input. Active low, pulled up internally. Low turns on the RED LED (default is on) GREEN LED input. Active low, pulled up internally. Low turns on the GREEN LED (takes precedence over RED) 12V power input – 200mA for S40, 250mA for S40i Weigand D1 output. Open collector, pulled up internally Wiegand D0 output. Open collector, pulled up internally Tamper output. Open circuit when the tamper switch is closed. Connects to 0V on tamper Cable lengths of up to 150m are supported, provided the correct power supply voltage is presented to the S40 Connect the Controller Wiegand inputs to the S40 Wiegand outputs, and the Controller Beep and LED control outputs to the relevant S40 Beep and LED control inputs S40/S40i Engineering Manual Rev 1 April 2015 Page 2 of 5 www.storm-interface.com © Copyright Storm Interface. 2015. All rights reserved Engineering Manual for AXS Series S40/S40i Keypad Physical installation - Using the case as a template, mark the position of the four holes (A) on the surface. (or if fixing to an already installed UK or US back box use the relevant hole pattern) - Drill fixing holes to suit the supplied fixing screws - Push the cable through the sealing grommet and secure the case to the mounting surface using the fixing screws - Make the electrical connections to the connector block (the connector block can be removed to aid wiring) - Position the rubber seal on the mating edge of the rear case. - Fix the keypad to the rear case using the security screws - Use the nylon sealing washers under the screw heads to protect against moisture ingress - Check the installation to ensure the rubber seal is in place and is compressed evenly around the perimeter of the case. Weigand Formats For PIN Factory default is Weigand 8 bit burst format (for PIN) If you need Weigand 4 bit burst format, follow the sequence below. Press # on power up LED FLASHES RED/GREEN Press #725 to enter FORMAT mode Press 1 or for FORMAT for RESET TO DEFAULT Press 0 or for 4 BIT FORMAT for 8 BIT FORMAT Press 0 to EXIT, LED STAYS RED This setting is retained even if power is removed For Cards Factory default is 26-bit Wiegand for all presented cards. If alternative Wiegand formats are required please contact us via the website www.storm-interface.com S40/S40i Engineering Manual Rev 1 April 2015 Page 3 of 5 www.storm-interface.com © Copyright Storm Interface. 2015. All rights reserved Engineering Manual for AXS Series S40/S40i Keypad Typical Wiring Below is a typical wiring schedule – in this case between the S40 and the Kantech KT-300 Controller The S40 is shown connected to control Door 2. Where there is an LED connection, usually the GREEN LED connection is appropriate Wire name Wiegand Data 0 Wiegand Data 1 0V +12V Buzzer LED Wire colour Green White Black Red Blue Brown KT-300 READ2 Green READ2 White READER PWR GND READER PWR +12V OUT DOOR 2 BUZ OUT DOOR 2 LED S40 Pin K Pin J Pin E or Pin F Pin I Pin B Pin H Specifications Card Compatibility iClass®, Mifare® serial number ISO15693, ISO14443A&B Card Read Range 2-5cm (depending on card) Card Security V1 Security (Elite security by special order only) Coupling Frequency 13.56 MHz Power supply 5V +/- 10% or 12V +/- 15% DC 200mA / 250mA (illuminated) (Illumination only active with a 12V power supply) Cable distance to host 150m max Tamper detection Normally open (N.O.), or normally closed (N.C.) tamper switch Status Indication RED/GREEN or BEEP as driven by the attached Controller Tamper switch Max 30V DC, 500mA Operational Temperature -35°C to +65°C Weather Resistance IP65 Vibration & Shock ETSI 6M3 Impact Resistance IK09 (10J Rating) Certifications CE / FCC / UL294 S40/S40i Engineering Manual Rev 1 April 2015 FCC ID 2AEEZ-DS40 Page 4 of 5 IC 29008-DS40 www.storm-interface.com © Copyright Storm Interface. 2015. All rights reserved Engineering Manual for AXS Series S40/S40i Keypad Regulatory Information This device complies with Part 15 of the FCC Rules and Industry Canada licence exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment S40/S40i Engineering Manual Rev 1 April 2015 Page 5 of 5 www.storm-interface.com © Copyright Storm Interface. 2015. All rights reserved
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Gareth Richards Create Date : 2015:05:05 11:30:38+01:00 Modify Date : 2015:05:05 11:30:40+01:00 Subject : Language : EN-GB Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2015:05:05 11:30:40+01:00 Creator Tool : Acrobat PDFMaker 11 for Word Document ID : uuid:daabf115-1d51-4086-920b-4d3cb424c51c Instance ID : uuid:fb452bce-55a7-40e8-8d8e-4376c6dc943b Format : application/pdf Title : Description : Creator : Gareth Richards Producer : Adobe PDF Library 11.0 Keywords : Source Modified : D:20150505103003 Company : Comments : Page Layout : OneColumn Page Count : 5EXIF Metadata provided by EXIF.tools