Keysight Technologies Malaysia Sdn Bhd U1117A IR-to-Bluetooth Adapter User Manual

Keysight Technologies Malaysia Sdn. Bhd. IR-to-Bluetooth Adapter

User Manual

Keysight U1117A IR-to-Bluetooth AdapterOperating InstructionsThe Keysight U1117A Infrared (IR)-to-Bluetooth®1 adapter is designed to be used with the Keysight U1200 Series handheld meters. The U1117A adapter enables you to connect the handheld meter to the Keysight U1115A remote logging display or Windows PC/Android devices/iOS devices via the Keysight mobile application/PC application software for a total wireless remote connectivity solution of up to 100-metres2.  Figure 1. Keysight wireless remote connectivity solutionStandard Shipped Items Checklist  The following items are included when you make a purchase:• U1117AIR-to-Bluetooth adapter• Two1.5VAAAbatteries• OperatingInstructions(thissheet)1 The Bluetooth® word mark and logos are registered trademark owned by Bluetooth SIG, Inc and any    use of such marks by Keysight is under license. Other trademark and trade names are those of their    respective owners.2 Only applicable when connected to any dongle with BluetoothClass1classication.Keysight U1200 Series handheld metersU1117A IR-to-Bluetooth adapterU1177A IR-to-Bluetooth adapterWindows PCAndroid devicesiOS devicesU1115A remote logging displayKeysight PC Application Software        Keysight Handheld Meter          LoggerKeysight Mobile Application        Keysight Mobile Meter               Keysight Mobile Logger1
Product CharacteristicsTemperature Operating condition: –20 °C to 55 °CStorage condition: –40 °C to 70 °CRelative Humidity (R.H.)Operating condition: Up to 80% at 40 °C (non-condensing)Storage condition: Up to 95% at 40 °C (non-condensing)Dimension (W x L x H) 39.0 mm × 71.0 mm × 37.0 mmWeight 60 g with batteriesBattery Type Lithium 24–LF (ANSI) and FR03•  (IEC) Alk• aline 24 A (ANSI/NEDA) and LR03 (IEC)Zinc Chloride 24 D (ANSI/NEDA) and R03 (IEC)•Battery Lifespan Lithium batteries: 30 hoursAlkaline batteries: 20 hoursPower Consumption Maximum561mVAfortwo1.5VAAAbatteriesWarranty Three months (Does not cover normal wear and tear of mechanical parts and batteries)Bluetooth Bluetooth SPPprole,Class1device,rangeupto100mCompatibility Keysight Handheld Meter/Display:Keysight U1200 Series Handheld Meters•Keysight U1115A Remote Logging Display•Keysight PC Application Software:Keysight Handheld Meter Logger•Keysight Mobile Application:Keysight Mobile Meter•Keysight Mobile Logger•Hardware Devices:iPhone•iPad•iPod Touch•Android smartphone/tablet•Windows PC (with • Bluetooth-enabled)2
Regulatory  The U1117A complies with the requirements of the  following product standards:EMC•EN301489–1V1.9.2•EN301489–17:V2.2.1•EN 55022:2010•EN55024:2010•RF (• Bluetooth)EN300328V1.7.1•RF (Health)•EN 62311:2008•Safety•EN 60950–1:2006+A11:2009+A12:2011•India E• quipmentTypeApproval(ETA)CerticateNo:NER-ETA/923“This telecommunication equipment conforms to the NTC technical requirement”Canada IC: The device contains transmitter IC: 5123A–BGTWT11IA•To comply with FCC and Industry Canada RF radiation exposure limits •for general population, the antenna(s) used for this transmitter must be installed such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and all persons at all times and must not be colocated or operating in conjunction with any other antenna or transmitter.“La operación de este equipo está sujeta a las siguientes dos  •condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada.”Complies with  IDA Standards  DB 1024253
“Este produto está homologado pela Anatel, de acordo com os  •procedimentos regulamentados pela Resolução nº 242/2000 e atende aos requisitos técnicos aplicados, incluindo os limites de exposição da Taxa de Absorção Especícareferenteacamposelétricos,magnéticose eletromagnéticos de radiofrequência de acordo com as Resoluções nº 303/202 e 533/2009”. “Este equipamento opera em caráter secundário, isto é, não tem •direito a proteção contra interferência prejucidial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em carater primário”.Manter distância mínima de 10 cm do corpo humano.Para maiores informações, consulte o site da ANATEL www.anatel.gov.brTheradiomodulecertiedbyJapaneseRadioLawisintegratedinside.•NCC Warning Statement:•Article 12•Withoutpermission,anycompany,rmorusershallnotalterthefrequency, increase the power, or change the characteristics and functionsoftheoriginaldesignofthecertiedlowerpower frequency electric machinery.Article 14•The application of low power frequency electric machineries  shall not affect the navigation safety nor interfere a legal  communication, if an interference is found, the service will be  suspended until improvement is made and the interference no  longer exists.4
AccordingtoFCCpart15:21,changesormodicationsnotexpressly•approved by the manufacturer for compliance could void the user’s au-thority to operate the equipment.According to FCC part 15.105(b): •This equipment has been tested and found to comply with the lim-its for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accoradance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. –Consultthedealeroranexperiencedradio/TVtechnicianforhelp.5
Front ViewLED Indicator and Slide Switch                                             Low battery — LEDredashing                                             1. Bluetooth disconnected — LED greenashing                                             2. Bluetooth connected — LED solid green                                             3. Bluetooth power off — LED off                                             Slide switchOperationDo not open the plastic case unnecessarily. Doing so may cause  •damage to the plastic case.K• eep the adapter away from getting wet.Ensu• re the adapter is turned OFF and the battery cover is removed when replacing the batteries.The b• atteries must be recycled or disposed properly after depletion.I• f the LED is not lighted when turned on, replace the batteries with newspeciedbatteries.T• he adapter can only be used with Keysight handheld meters.Install and Replace the BatteriesMake sure you turn off the U1117A before installing or replacing the batteries.To avoid the U1117A being damage from battery leakage:Alw• ays remove dead batteries immediately.A• lways remove the batteries and store them seperately if the adapter is not going to be used for a long period.6
1. Slide the battery cover     away from adapter’s     body.2. Insert the batteries. 3. Reverse the sliding      position to close the     battery cover. Turn On the U1117A                                 Set the slide switch to On. Congure the U1117ATheU1117Aisdesignedtobeusedstraightfromtheboxwithoutanyconguration.How-ever,ifyourhardwarerequiresspecialconguration,youmaysetuptheU1117A usingtheU1117ACongurationUtility—downloadableat www.keysight.com/nd/U1117A         Set the slide switch to Setup.     7
Reset the U1117A1. Open the battery cover. Then, set the     slide switch to Setup.2.Useaat-bladescrewdrivertopushthe     button located in the hole for around three     seconds.Connect Your U1117A Adapter to the Keysight Handheld Meter Snap the optic side of the U1117A to the handheld meter’s IR communication port.8
Install the U1117A to PC via BluetoothBefore you begin, make sure the • Bluetooth connection on your PC is enabled.It is•  recommended to use brand new batteries before running any operations that are critical or require a longer duration.In so• me cases, the Bluetooth Device Manager will create two COM ports. Use the COM port with the “Outgoing” label only.1.   Set the U1117A slide switch to On. 2.   From your PC (Windows 7), go to Start > Devices and Printers. 3.   Click Add a device. 4.   Select Keysight U1117A-XXXXXX—the XXXXXX represents U1117A device ID       —and click Next.5.   Type the default Bluetooth pairing code “1234” and click Next.6.Oncepairingissuccessful,anoticationwindowwillappear.ClickClose. 7.   The U1117A-XXXXXX is now added and connected successfully to your PC. Connect a Meter to the Keysight Handheld Meter Logger via the U1117ABefore you begin, make sure you download the Keysight Handheld Meter Logger at  www.keysight.com/nd/hhmeterlogger1. Open the Keysight Handheld Meter Logger. 2. On the Connected Instruments List (at the bottom), select the U1117A-XXXXX and                click Connect to establish the multimeter connection. 3. The multimeter will remain connected until the connection is disconnected or the      U1117A is turned off.Only one host computer is able to conne• ct to the U1117A at a time.Connect a Meter to the Keysight U1115A Remote Logging  Display via the U1117AFor details, refer to the U1115A Remote Logging Display Operating Instructions at  www.keysight.com/nd/U1115A.9
Connect a Meter Remotely via the Keysight Mobile Application (Keysight Mobile Apps)You can now turn your Android and iOS devices into a remote measurement, control and reporting devices using both the Keysight Mobile Meter and Keysight Mobile Logger —available on the Google Play and App Store.  These Mobile Apps allow you to wirelessly control your Keysight handheld meter with your Android devices and iOS devices via the Keysight U1117A adapter. All Keysight handheld meters are supported, with the exception of the Keysight U1240 Se-ries, which requires an additional Keysight U1179A IR Connectivity Bracket for compability with the Keysight U1117A adapter.VisittheURLsbelowformoreinformationontheKeysightMobileApps:Android deviceshttp://play.google.com/store/apps/details?id=com.keysight.mobilemeterhttp://play.google.com/store/apps/details?id=com.keysight.mobilemeterloggeriOS deviceshttps://itunes.apple.com/us/app/keysight-mobile-meter/id675491562?ls=1&mt=8https://itunes.apple.com/us/app/keysight-mobile-logger/id675497444?ls=1&mt=8MaintenanceIf any part of the adapter is worn out or damaged, replace it with a new U1117A adapter.AssistanceFor technicalassistance,contactyournearestKeysightSalesOfceorvisittheKeysightwebsite at www.keysight.com/nd/assist for further information.10U1117-90103©Keysight Technologies, Inc., 2014 Printed in MalaysiaOctober 31, 20141852-14-7510(01) 07898994220626

Navigation menu