Keysight Technologies Malaysia Sdn Bhd U1117A IR-to-Bluetooth Adapter User Manual

Keysight Technologies Malaysia Sdn. Bhd. IR-to-Bluetooth Adapter

User Manual

Keysight U1117A IR-to-Bluetooth Adapter
Operating Instructions
The Keysight U1117A Infrared (IR)-to-Bluetooth®1 adapter is designed to be used with the
Keysight U1200 Series handheld meters. The U1117A adapter enables you to connect the
handheld meter to the Keysight U1115A remote logging display or Windows PC/Android
devices/iOS devices via the Keysight mobile application/PC application software for a
total wireless remote connectivity solution of up to 100-metres2.
Figure 1. Keysight wireless remote connectivity solution
Standard Shipped Items Checklist
The following items are included when you make a purchase:
• U1117AIR-to-Bluetooth adapter
• Two1.5VAAAbatteries
• OperatingInstructions(thissheet)
1
The Bluetooth® word mark and logos are registered trademark owned by Bluetooth SIG, Inc and any
use of such marks by Keysight is under license. Other trademark and trade names are those of their
respective owners.
2 Only
applicable when connected to any dongle with
BluetoothClass1classication.
Keysight U1200
Series handheld
meters
U1117A IR-to-
Bluetooth adapter
U1177A IR-to-
Bluetooth adapter
Windows PC
Android devices
iOS devices
U1115A remote logging
display
Keysight PC Application Software
Keysight Handheld Meter
Logger
Keysight Mobile Application
Keysight Mobile Meter
Keysight Mobile Logger
1
Product Characteristics
Temperature Operating condition: –20 °C to 55 °C
Storage condition: –40 °C to 70 °C
Relative Humidity
(R.H.)
Operating condition: Up to 80% at 40 °C (non-condensing)
Storage condition: Up to 95% at 40 °C (non-condensing)
Dimension (W x L x H) 39.0 mm × 71.0 mm × 37.0 mm
Weight 60 g with batteries
Battery Type Lithium 24–LF (ANSI) and FR03• (IEC)
Alk• aline 24 A (ANSI/NEDA) and LR03 (IEC)
Zinc Chloride 24 D (ANSI/NEDA) and R03 (IEC)•
Battery Lifespan Lithium batteries: 30 hours
Alkaline batteries: 20 hours
Power Consumption Maximum561mVAfortwo1.5VAAAbatteries
Warranty Three months (Does not cover normal wear and tear of
mechanical parts and batteries)
Bluetooth Bluetooth SPPprole,Class1device,rangeupto100m
Compatibility Keysight Handheld Meter/Display:
Keysight U1200 Series Handheld Meters•
Keysight U1115A Remote Logging Display•
Keysight PC Application Software:
Keysight Handheld Meter Logger•
Keysight Mobile Application:
Keysight Mobile Meter•
Keysight Mobile Logger•
Hardware Devices:
iPhone•
iPad•
iPod Touch•
Android smartphone/tablet•
Windows PC (with • Bluetooth-enabled)
2
Regulatory The U1117A complies with the requirements of the
following product standards:
EMC•
EN301489–1V1.9.2•
EN301489–17:V2.2.1•
EN 55022:2010•
EN55024:2010•
RF (• Bluetooth)
EN300328V1.7.1•
RF (Health)•
EN 62311:2008•
Safety•
EN 60950–1:2006+A11:2009+A12:2011•
India E• quipmentTypeApproval(ETA)CerticateNo:
NER-ETA/923
“This telecommunication equipment conforms to the NTC
technical requirement”
Canada IC: The device contains transmitter IC: 5123A–BGTWT11IA•
To comply with FCC and Industry Canada RF radiation exposure limits •
for general population, the antenna(s) used for this transmitter must
be installed such that a minimum separation distance of 20cm is
maintained between the radiator (antenna) and all persons at all times
and must not be colocated or operating in conjunction with any other
antenna or transmitter.
“La operación de este equipo está sujeta a las siguientes dos •
condiciones: (1) es posible que este equipo o dispositivo no cause
interferencia perjudicial y (2) este equipo o dispositivo debe aceptar
cualquier interferencia, incluyendo la que pueda causar su operación
no deseada.”
Complies with
IDA Standards
DB 102425
3
“Este produto está homologado pela Anatel, de acordo com os •
procedimentos regulamentados pela Resolução nº 242/2000 e atende
aos requisitos técnicos aplicados, incluindo os limites de exposição da
Taxa de Absorção Especícareferenteacamposelétricos,magnéticos
e eletromagnéticos de radiofrequência de acordo com as Resoluções
nº 303/202 e 533/2009”.
“Este equipamento opera em caráter secundário, isto é, não tem •
direito a proteção contra interferência prejucidial, mesmo de estações
do mesmo tipo, e não pode causar interferência a sistemas operando
em carater primário”.
Manter distância mínima de 10 cm do corpo humano.
Para maiores informações, consulte o site da ANATEL
www.anatel.gov.br
TheradiomodulecertiedbyJapaneseRadioLawisintegratedinside.•
NCC Warning Statement:•
Article 12•
Withoutpermission,anycompany,rmorusershallnotalterthe
frequency, increase the power, or change the characteristics and
functionsoftheoriginaldesignofthecertiedlowerpower
frequency electric machinery.
Article 14•
The application of low power frequency electric machineries
shall not affect the navigation safety nor interfere a legal
communication, if an interference is found, the service will be
suspended until improvement is made and the interference no
longer exists.
4
AccordingtoFCCpart15:21,changesormodicationsnotexpressly•
approved by the manufacturer for compliance could void the user’s au-
thority to operate the equipment.
According to FCC part 15.105(b): •
This equipment has been tested and found to comply with the lim-
its for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy, and if not
installed and used in accoradance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
–Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
5
Front View
LED Indicator and Slide Switch
Low battery — LEDredashing
1. Bluetooth disconnected — LED greenashing
2. Bluetooth connected — LED solid green
3. Bluetooth power off — LED off
Slide switch
Operation
Do not open the plastic case unnecessarily. Doing so may cause •
damage to the plastic case.
K• eep the adapter away from getting wet.
Ensu• re the adapter is turned OFF and the battery cover is removed
when replacing the batteries.
The b• atteries must be recycled or disposed properly after depletion.
I• f the LED is not lighted when turned on, replace the batteries with
newspeciedbatteries.
T• he adapter can only be used with Keysight handheld meters.
Install and Replace the Batteries
Make sure you turn off the U1117A before installing or replacing
the batteries.
To avoid the U1117A being damage from battery leakage:
Alw• ays remove dead batteries immediately.
A• lways remove the batteries and store them seperately if the adapter
is not going to be used for a long period.
6
1. Slide the battery cover
away from adapter’s
body.
2. Insert the batteries. 3. Reverse the sliding
position to close the
battery cover.
Turn On the U1117A
Set the slide switch to On.
Congure the U1117A
TheU1117Aisdesignedtobeusedstraightfromtheboxwithoutanyconguration.How-
ever,ifyourhardwarerequiresspecialconguration,youmaysetuptheU1117A
usingtheU1117ACongurationUtility—downloadableat
www.keysight.com/nd/U1117A
Set the slide switch to Setup.
7
Reset the U1117A
1. Open the battery cover. Then, set the
slide switch to Setup.
2.Useaat-bladescrewdrivertopushthe
button located in the hole for around three
seconds.
Connect Your U1117A Adapter to the Keysight Handheld Meter
Snap the optic side of the U1117A to the handheld meter’s IR communication port.
8
Install the U1117A to PC via Bluetooth
Before you begin, make sure the • Bluetooth connection on your PC
is enabled.
It is• recommended to use brand new batteries before running any
operations that are critical or require a longer duration.
In so• me cases, the Bluetooth Device Manager will create two COM
ports. Use the COM port with the “Outgoing” label only.
1. Set the U1117A slide switch to On.
2. From your PC (Windows 7), go to Start > Devices and Printers.
3. Click Add a device.
4. Select Keysight U1117A-XXXXXX—the XXXXXX represents U1117A device ID
—and click Next.
5. Type the default Bluetooth pairing code “1234” and click Next.
6.Oncepairingissuccessful,anoticationwindowwillappear.ClickClose.
7. The U1117A-XXXXXX is now added and connected successfully to your PC.
Connect a Meter to the Keysight Handheld Meter Logger via
the U1117A
Before you begin, make sure you download the Keysight Handheld Meter Logger at
www.keysight.com/nd/hhmeterlogger
1. Open the Keysight Handheld Meter Logger.
2. On the Connected Instruments List (at the bottom), select the U1117A-XXXXX and
click Connect to establish the multimeter connection.
3. The multimeter will remain connected until the connection is disconnected or the
U1117A is turned off.
Only one host computer is able to conne• ct to the U1117A at a time.
Connect a Meter to the Keysight U1115A Remote Logging
Display via the U1117A
For details, refer to the U1115A Remote Logging Display Operating Instructions at
www.keysight.com/nd/U1115A.
9
Connect a Meter Remotely via the Keysight Mobile Application
(Keysight Mobile Apps)
You can now turn your Android and iOS devices into a remote measurement, control and
reporting devices using both the Keysight Mobile Meter and Keysight Mobile Logger
—available on the Google Play and App Store. These Mobile Apps allow you to wirelessly
control your Keysight handheld meter with your Android devices and iOS devices via the
Keysight U1117A adapter.
All Keysight handheld meters are supported, with the exception of the Keysight U1240 Se-
ries, which requires an additional Keysight U1179A IR Connectivity Bracket for compability
with the Keysight U1117A adapter.
VisittheURLsbelowformoreinformationontheKeysightMobileApps:
Android devices
http://play.google.com/store/apps/details?id=com.keysight.mobilemeter
http://play.google.com/store/apps/details?id=com.keysight.mobilemeterlogger
iOS devices
https://itunes.apple.com/us/app/keysight-mobile-meter/id675491562?ls=1&mt=8
https://itunes.apple.com/us/app/keysight-mobile-logger/id675497444?ls=1&mt=8
Maintenance
If any part of the adapter is worn out or damaged, replace it with a new U1117A adapter.
Assistance
For technicalassistance,contactyournearestKeysightSalesOfceorvisittheKeysight
website at www.keysight.com/nd/assist for further information.
10
U1117-90103
©Keysight Technologies, Inc., 2014
Printed in Malaysia
October 31, 2014
1852-14-7510
(01) 07898994220626

Navigation menu