FM-200® Component Description A UTC Fire & Security Company Pressure Operated Switch Effective: September 2010 K-90-5180 FEATURES • For Use with UL Listed, ULC Listed and FM Approved Systems P/N: • See Kidde® Manual 90-FM200M-021 for USCG Approval 81-486536-000 OPERATED OPERATED SET SET STEM SHOWN IN SET POSITIONPULL UP ON STEM TO MANUALLY OPERATE SWITCH 0.375" WIRING SCREW TERMINALS 4.00" PRESSURE OPERATED SWITCH 3P.D.T. 8 COVER SCREWS TO RESET PUSH STEM TO SET POSITION U 15 AMP.— 125 V.AC L 10 AMP.—250 V.AC 3/4HP—250 VAC PT. NO. 486536 FM KIDDE-FENWAL, INC. 400 MAIN STREET ASHLAND, MA 01721 TO RESET PUSH STEM TO SET POSITION 15 AMP 125 VAC 10 AMP 250 VAC 3/4 HP 1-2-3 PH 125-480 VAC 4.00" FRONT VIEW COVER REMOVED 1/2” SUPPLY PIPE WITH UNION FRONT VIEW OPERATED SET NC BOX 3 EACH SIDE 1/2” CONDUIT KNOCKOUTS SWITCH 3PDT NC C C NC C COVER NO GASKET ½” NPT FEMALE, CONNECT TO SYSTEM PIPING SIDE SECTION NOTES: • The switch may be mounted in any position; however, the preferred installation is upright, as shown. • Any load connection to the switch must not exceed the switch rating, and shall utilize a suitable protection device (i.e., circuit breaker, fuse). • NO NO PRESSURE INLET WIRING DIAGRAM Contact Ratings (3 PDT): – 15 Amp @125 Vac – 10 Amp @ 250 Vac – 3/4 HP @ 250 Vac – 1, 2 or 3 Phase FM-200 is a registered trademark of the Great Lakes Chemical Corporation. This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product’s suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. K-90-5180 Rev AC © 2010 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.2.2-c063 53.352624, 2008/07/30-18:12:18 Producer : Acrobat Distiller 9.0.0 (Windows) Creator Tool : FrameMaker 9.0 Modify Date : 2010:09:22 15:15:31-04:00 Create Date : 2007:01:16 09:11:07Z Metadata Date : 2010:09:22 15:15:31-04:00 Format : application/pdf Title : K-90-5180.fm Creator : vernon.gross Document ID : uuid:3ae6ea01-0ba1-4a41-9b80-5d0f0c5add8f Instance ID : uuid:654bb2b6-6146-4439-a412-b8133b337fd0 Page Mode : UseNone Page Count : 1 Author : vernon.grossEXIF Metadata provided by EXIF.tools