Kidde XV™ Control System Effective: August 2013 K-87-027 P/N: 87-120099-002 FEATURES • For Use in: • • • • • WHDR™ Commercial Cooking Fire Suppression Systems • IND™ Industrial Fire Suppression Systems Pneumatic Release of up to 20 Agent Cylinders Two Discrete Mechanical Detection Lines Cylinder or Wall Mount Up to 400 ft. Mechanical Detection Cable • • • • • • • • Operates 2 Gas Valves Available 24 V Electrical Actuation Multiple Remote Release Options Rugged, Die-Cast Aluminum Body Tamper/Lock Port for Cover Easy to Install and Maintain UL & ULC Listed FM Approved for IND Systems DESCRIPTION The Kidde XV Control System is a compact, versatile unit used to actuate agent cylinders on Kidde WHDR and IND Pre-Engineered fire suppression systems. The control head can be operated via: • • • Two Distinct Automatic Mechanical Detection Lines (fusible links or thermo-bulb links) Optional Electrical Solenoid Remote or Local Manual Mechanical Control Upon actuation, the XV Control System discharges the nitrogen System Cartridge, pressurizing the actuation lines and System Valve Actuators (SVA) mounted on the cylinder valve(s). The SVA(s) open the cylinder valve(s), discharging the WHDR wet chemical or IND dry chemical suppression agent. The XV can be mounted on a wall or directly to an SVA mounted on the cylinder. The XV Control System is UL and ULC Listed with WHDR Wet Chemical and IND Dry Chemical Fire Suppression Systems. The XV is FM approved with the IND Dry Chemical Systems. The XV comes ready to install, with three EMT connectors, one System Valve Actuator (SVA), two microswitches, one nitrogen System Cartridge, and one nitrogen test cartridge. Figure 1. XV Control System, P/N 87-120099-002 TECHNICAL DATA Table 1. Mechanical Cable Parameters for WHDR & IND Systems Max. Cable Length Max. Corner Pulleys Max. Detectors Max. Tee Pulleys Detection and Manual Release-to-Trip Line 1 200 ft. (60.96 m) 50 40 * Detection and Manual Release-to-Trip Line 2 200 ft. (60.96 m) 50 40 * Pull-to-Trip Remote Manual Release Line 100 ft. (30.48 m) 30 - 1* Mechanical Gas Valve Line 100 ft. (30.48 m) 30 - 1* XV Cable Line *Tee pulleys count as two Corner Pulleys. Maximum is from XV Control, through the pulley, to each device. Table 2. Actuation Parameters for WHDR Wet Chemical Systems Operating Temperature Range Number of Extinguishing System Cylinders Maximum Total Length Copper Actuation Tubing 0°F to 120°F (-18°C to 49°C) 1-12 106 ft. (32.30 m) 13-20 91 ft. (27.73 m) Minimum Total Length of Copper Actuation Tubing 5 ft. (1.52 m) Table 3. Actuation Parameters for IND Industrial Dry Chemical and Open-Face Spray Booth Systems Operating Temperature Range Number of Extinguishing System Cylinders Maximum Total Length Copper Actuation Tubing -40°F to 120°F (-40°C to 49°C) 1-14 166 ft. (50.60 m) 15-20 121 ft. (36.88 m) Minimum Total Length of Copper Actuation Tubing 5 ft. (1.52 m) Table 4. Actuation Parameters for IND Dry Chemical for Vehicle Spray Booths Operating Temperature Range 0°F to 120°F (-18°C to 49°C) Number of Extinguishing System Cylinders Maximum Total Length Copper Actuation Tubing 1-8 200 ft. (60.96 m) 9-15 160 ft. (48.76 m) 16-20 140 ft. (42.67 m) Minimum Total Length of Copper Actuation Tubing 5 ft. (1.52 m) NOTES 1. 2. 3. Braided high pressure nitrogen tubing (P/N 87-120045-00X), is required to connect the XV Control System to the System Valve Actuator (SVA) when the XV Control System is cylinder mounted. Copper tubing shall be 1/4-inch O.D. x 0.031-inch wall high pressure tubing. When Control System is cylinder mounted and two or more cylinders are being actuated, a minimum of 5 ft. (1.52 m) of 1/4-inch O.D. x 0.031-inch wall tubing shall be used for actuation lines. -2- 4. 5. 6. 7. When Control System is wall mounted, a minimum of 5 ft. (1.52 m) of 1/4-inch O.D. x 0.031-inch wall tubing shall be used in the overall actuation line. High pressure nitrogen tubing (P/N 87-120045-00X) may be used in place of copper tubing, not to exceed a maximum length of 30 feet (9 m). In every system, either single cylinder or multiple cylinder, a 1/8-inch NPT plug or vent check (P/N WK-877810000) shall be used in the outlet port of the last System Valve Actuator(s) in the actuation line. A maximum of 2 Pressure Switches (P/N 486536) may be used in the actuation line. SYSTEM NITROGEN CARTRIDGE, P/N 87-120043-001 The XV Control System uses a nitrogen cartridge for actuating the system cylinders and is charged with dry nitrogen (see Figure 2). The cartridge is mounted inside the XV Control System to protect it from tampering and provides the date of manufacturing and space (gray band) for recording the installation date. 5-1/8 in. (130 mm) 1-9/16 in. (40 mm) GRAY BAND Figure 2. System Nitrogen Cartridge, P/N 87-120043-001 TEST CARTRIDGE, P/N 87-120044-001 The Test Cartridge is used for functional testing of the Kidde WHDR Wet Chemical System and IND Dry Chemical System*. The cartridge has a red band and is labeled “TEST CARTRIDGE” as shown in Figure 3. *Note: The System Nitrogen Cartridge P/N 87-120043-001 is required for actuation and full discharge or "puff" tests, and when a time delay is included (as in systems protecting Vehicle Spray Booths). 4 in. (102 mm) 1 in. (25 mm) Figure 3. Test Cartridge, P/N 87-120044-001 -3- SYSTEM VALVE ACTUATOR (SVA), P/N 87-120042-001 A System Valve Actuator (SVA) must be mounted to every system cylinder valve assembly (see Figure 4). The SVA has ports for low profile tubing runs, and is also equipped with a spring loaded plunger that locks the piston in the discharged position, ensuring complete discharge of the cylinder(s) contents. 5/16-18 UNC THROUGH HOLE (TYP) (NOT SHOWN) 1/8 in. NPT PORT 1-3/4 in. (44 mm) 1/8 in. NPT PLUG (IF APPLICABLE) SVA PISTON IN SET POSITION SPRING LOADED PLUNGER PISTON IN ACTUATED POSITION (TOWARDS CYLINDER VALVE) Figure 4. System Valve Actuator (SVA), P/N 87-120042-001 HIGH-PRESSURE NITROGEN TUBING, P/N 87-120045-00X The High-Pressure Nitrogen Tubing is used to connect the XV Control System to the SVA on all installations in which the XV Control System is mounted to a wet or dry chemical cylinder. (see Figure 5). A 1/8-inch NPT (male) x 3/8-24 JIC Adapter is included with the High Pressure Nitrogen Tubing. 1/8 in. NPT THREAD SEAT 1/2 in. HEX, 1/4 in. 37 DEGREE FLARE, SWIVEL 1/8 in. NPT (MALE) x 3/8-24 JIC ADAPTER A (END TO SEAT) Figure 5. External Tubing for XV Control System, P/N 87-120045-00X Table 5. External Tubing for XV Control System Part Number Length "A" 87-120045-001 7-1/2 in. (191 mm) 87-120045-002 24 in. (610 mm) 87-120045-003 60 in. (1524 mm) -4- SOLENOID, P/N 83-100034-001 WIRE TYPE KEY An optional solenoid can be installed into the XV Control System, just under the actuation latch. The solenoid operates directly on the actuation latch to activate the system. This installation allows simultaneous usage of mechanical detection lines, or the lines can be locked out. The solenoid includes two mounting bolts, the bracket and a push plate which mounts onto the solenoid body (Figure 6). The solenoid coil is 24 Vdc at 1.5 Amp and at 70°F (21°C). Refer to Figure 7 for Release Wiring with Terminal Type Microswitch. MICROSWITCH (INTERNAL) ALARM WIRES FROM CONTROL PANEL XV SOLENOID P/N 83-100034-001 24 VDC ONLY RELEASING CIRCUIT IN COMPATIBLE CONTROL PANEL (24 VDC ONLY) SPLICE SOLENOID LEAD TO RELEASING CIRCUIT 9/64 in. ALLEN SCREWS (2) MOUNTING BRACKET (DO NOT REMOVE) OPEN TERMINAL 2 TERMINAL 2 NOT USED FLAG ENGAGED BY XV ATTACH SOLENOID LEAD TO TERMINAL 1 OF MICROSWITCH When actuating the XV Control System with an optional solenoid, a UL Compatible and Listed fire control panel with a supervised power supply is required, such as the Kidde AEGIS or Kidde ARIES. PUSH PLATE (DO NOT REMOVE) ALARM WIRES TO XV SOLENOID AND/OR OTHER DEVICES ATTACH RELEASING CIRCUIT TO TERMINAL 4 OF MICROSWITCH COMMON TERMINAL 1 CLOSED TERMINAL 4 SWITCH POSITION WHEN XV FLAG/CAM IS IN SET POSITION Figure 7. Release Wiring with Terminal Type Microswitch Note: ELECTRICAL LEADS 24 in. (610 mm) SOLENOID BODY Figure 6. Solenoid, P/N 83-100034-001 Where electric detection and/or actuation is provided, supervision shall be provided in accordance with NFPA 72, National Fire Alarm and Signaling Code. Alarms and indicators, along with a supervised power source, shall be provided in accordance with NFPA 72. Electrical wiring and equipment shall be provided in accordance with NFPA 70, National Electric Code. All installations are subject to the approval of the Authority Having Jurisdiction (AHJ). KEEPER PIN, P/N 60-9197108-000 The Keeper Pin (P/N 60-9197108-000) is used to prevent actuation while installing the system. Figure 8. Keeper Pin, P/N 60-9197108-000 -5- ORDERING INFORMATION Description XV Control System includes: (1) 87-120042-001 System Valve Actuator (1) 87-120043-001 System Nitrogen Cartridge (1) 87-120044-001 Test Cartridge (1) 87-120058-001 EMT Connector Kit (1) 87-120039-001 Microswitch Kit (1) 87-120039-501 Microswitch Kit 87-120099-002 System Valve Actuator 87-120042-001 System Nitrogen Cartridge 87-120043-001 Test Cartridge 87-120044-001 High Pressure Hose for Cylinder Mount 87-120045-001 EMT Connector Kit 87-120058-001 Solenoid Electric Actuator Kit 83-100034-001 Microswitch Kit (SPDT), Solid Color Leads 87-120039-001 Microswitch Kit (SPDT), Striped Color Leads 87-120039-501 Terminal Type Microswitch Kit (SPDT) 87-120047-001 REFERENCE INFORMATION • • Part Number WHDR Systems designed and installed according to manual P/N 87-122000-001. IND Systems designed and installed according to manual P/N 220423. MOUNTING HOLE • Vehicle Spray Booth Systems designed and installed according to manual P/N 83-100036-001. MOUNTING HOLE 5-1/2 in. (140 mm) TO OPERATE PULL PIN 9-3/4” (248 mm) 7-5/8 in. (194 mm) TURN HANDLE FIRE SUPPRESSION SYSTEM 3/4 in. (19 mm) MOUNTING HOLE 1-5/16 in. (34 mm) 4-3/8 in. (112 mm) 8-1/2” (216 mm) 3-3/4” (95 mm) MOUNTING HOLE Figure 9. XV Control System Dimensions Kidde is a registered trademark of Kidde-Fenwal, Inc. WHDR, IND, XV, AEGIS, and ARIES are trademarks of Kidde-Fenwal, This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product’s suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. K-87-027 Rev AG © 2013 Kidde-Fenwal Inc. 400 Main Street Ashland, MA 01721 Tel.: 508-881-2000 Fax: 508-881-8920 www.kiddefiresystems.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Anita.Tsiagras Create Date : 2007:01:16 09:11:07Z Modify Date : 2013:07:22 17:33:30-04:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : Anita.Tsiagras Title : K-87-027.fm Creator Tool : FrameMaker 9.0 Metadata Date : 2013:07:22 17:33:30-04:00 Producer : Acrobat Distiller 10.1.5 (Windows) Document ID : uuid:aaf6b670-be3a-4c79-8d91-8648e86c0731 Instance ID : uuid:ce21375d-e8ee-43f3-bbaa-bdacdcf63d2f Page Layout : SinglePage Page Mode : UseNone Page Count : 6EXIF Metadata provided by EXIF.tools