KVS-2025 Automatic
Fire Sensing System

A UTC Fire & Security Company

Effective: February 2007
K-83-102

FEATURES
•
•
•
•
•

Vehicle Fire System Control Panel
Expandable, modular
Programmable Time Delay
Multiple system discharge capability
Battery Backup Module

•
•
•
•
•

Alarm Silence Switch
LED annunciation of alarm, trouble, fire, operation
Low Maintenance
12V or 24V electrical systems
FM approved, including heavy-duty off-road vehicle
approvals

DESCRIPTION
The Kidde® KVS detection system uses a fast response,
infrared fire sensor, spot heat detection and/or Linear
Heat Sensing Cable, all of which continually monitor the
hazard area for a fire condition. Once a fire is detected, a
signal is immediately sent to the control panel located in
the operator’s area where a “FIRE” lamp is illuminated
and an audible alarm is sounded. The control unit supplies engine shutdown and extinguisher discharge timing
and activation. The dry chemical and/or foam system discharges suppressant routed through distribution hoses to
nozzles located in the engine compartment, hydraulic
network and other identified potential fire areas. The
vehicle engine can be automatically shutdown to maximize effectiveness of the suppressant and to prevent reignition of the fire.
The Kidde KVS Automatic Fire Sensing and Suppression
Systen is designed to detect and automatically suppress
vehicle fires. The system responds to fires fueled by: diesel, gasoline, hydraulic fluid, and other fuels, including
hydrogen.
Areas where fires can occur include:

TECHNICAL DATA

•

•
•
•
•
•
•

•
•
•
•

Engine Compartment:
– Fuel Tanks and Lines
– Hydraulic Reservoirs
– Lines and Accumulators
Heaters
Transmissions
Battery Compartment
Electrical Distribution and Raceways

•
•
•
•
•
•

Power Requirement: 12 Vdc or 24 Vdc (9 to 32 Vdc)
Quiescent (Fire Only): 2.4 W
Extinguisher Valve Drive Requires 15 A for 30 ms
Temperature Rating: -40ºF (-40ºC) to 158ºF (70ºC)
Automatic Interface
Normally-Open 3 Amp Contact Shorts to Ground
when in Alarm
Engine Shutdown
Fuel Pump and/or Fuel Valve Shutdown
Fan Shutdown
Delay System/Engine-Shutdown Button (15 sec.
delay per activation)
Alarm Silence, Reset, Indicator Test Button
Manual Discharge Input

ORDERING INFORMATION
Part Number
83-132002-001
83-132001-001

Description

Shipping
Weight

KVS-20205 Control Panel

1 lb.

KVS-2020 Infared Sensor

ø.20 - 4 PLS
FIRE
PROTECTION PANEL
413410

SYSTEM OK

1 lb.

83-132003-001

KVS-2020 Expansion
Module

1 lb.

83-132015-001

KVS-2020 End-of-line
Device

1 lb.

83-132016-001

KVS-2020 IR Test Kit

2 lb.

83-132017-001

KVS-2020 Backup Battery
Assembly,

5 lb.

83-100001-003

LHS (Linear Heat Sensing)
Cable 100 m Reel (328 ft.
approx.)

10 lb.

5.25

4.25

TROUBLE

ALARM

FIRE

4.76

ALARM SILENCE

TEST/RESET

ENGAGED

DELAY
ENGINE
STOP

1.50
2.72

1.29

.46

Figure 1. KVS-2020 Front View

J1 Mating Connector is Deutsch DT06-12S

MOUNTING POINTS - 4 PLS

R.50
J1

1.00

1.17

CUTOUT

2.30

4.75
3.58
.10

1.30

1.50

Figure 2. KVS-2020 Side View
Kidde is a registered trademarks of Kidde-Fenwal, Inc.
3M and Novec are trademarks of 3M.
All other trademarks are property of their respective owners.

This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes
no responsibility for the product’s suitability for a particular application. The product must be
properly applied to work correctly.
If you need more information on this product, or if you have a particular problem or question,
contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000.
K-83-102 Rev AB

© 2007 Kidde-Fenwal Inc.

Printed in USA

A UTC Fire & Security Company
400 Main Street
Ashland, MA 01721
Ph: 508.881.2000
Fax: 508.881.8920
www.kiddefiresystems.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Mode                       : UseNone
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : FrameMaker 7.1
Modify Date                     : 2007:04:05 09:55:39Z
Create Date                     : 2007:01:16 09:11:07Z
Format                          : application/pdf
Title                           : K-83-102.fm
Creator                         : dick.tracy
Document ID                     : uuid:31119bc8-b4d5-427b-bd9e-af204ec0bbe1
Instance ID                     : uuid:20230bf3-d5d6-4e2e-93e7-d4fa57d201e5
Page Count                      : 2
Author                          : dick.tracy
EXIF Metadata provided by EXIF.tools

Navigation menu