Effective: February 2007
K-83-102
KVS-2025 Automatic
Fire Sensing System
FEATURES
• Vehicle Fire System Control Panel
• Expandable, modular
• Programmable Time Delay
• Multiple system discharge capability
• Battery Backup Module
• Alarm Silence Switch
• LED annunciation of alarm, trouble, fire, operation
• Low Maintenance
• 12V or 24V electrical systems
• FM approved, including heavy-duty off-road vehicle
approvals
DESCRIPTION
The Kidde® KVS detection system uses a fast response,
infrared fire sensor, spot heat detection and/or Linear
Heat Sensing Cable, all of which continually monitor the
hazard area for a fire condition. Once a fire is detected, a
signal is immediately sent to the control panel located in
the operator’s area where a “FIRE” lamp is illuminated
and an audible alarm is sounded. The control unit sup-
plies engine shutdown and extinguisher discharge timing
and activation. The dry chemical and/or foam system dis-
charges suppressant routed through distribution hoses to
nozzles located in the engine compartment, hydraulic
network and other identified potential fire areas. The
vehicle engine can be automatically shutdown to maxi-
mize effectiveness of the suppressant and to prevent re-
ignition of the fire.
The Kidde KVS Automatic Fire Sensing and Suppression
Systen is designed to detect and automatically suppress
vehicle fires. The system responds to fires fueled by: die-
sel, gasoline, hydraulic fluid, and other fuels, including
hydrogen.
Areas where fires can occur include:
• Engine Compartment:
– Fuel Tanks and Lines
– Hydraulic Reservoirs
– Lines and Accumulators
•Heaters
• Transmissions
• Battery Compartment
• Electrical Distribution and Raceways
TECHNICAL DATA
• Power Requirement: 12 Vdc or 24 Vdc (9 to 32 Vdc)
• Quiescent (Fire Only): 2.4 W
• Extinguisher Valve Drive Requires 15 A for 30 ms
• Temperature Rating: -40ºF (-40ºC) to 158ºF (70ºC)
• Automatic Interface
• Normally-Open 3 Amp Contact Shorts to Ground
when in Alarm
• Engine Shutdown
• Fuel Pump and/or Fuel Valve Shutdown
• Fan Shutdown
• Delay System/Engine-Shutdown Button (15 sec.
delay per activation)
• Alarm Silence, Reset, Indicator Test Button
• Manual Discharge Input
A UTC Fire & Security Company
400 Main Street
Ashland, MA 01721
Ph: 508.881.2000
Fax: 508.881.8920
www.kiddefiresystems.com
This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes
no responsibility for the product’s suitability for a particular application. The product must be
properly applied to work correctly.
If you need more information on this product, or if you have a particular problem or question,
contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000.
K-83-102 Rev AB © 2007 Kidde-Fenwal Inc. Printed in USA
ORDERING INFORMATION
Figure 1. KVS-2020 Front View
Part Number Description Shipping
Weight
83-132002-001 KVS-20205 Control Panel 1 lb.
83-132001-001 KVS-2020 Infared Sensor 1 lb.
83-132003-001 KVS-2020 Expansion
Module
1 lb.
83-132015-001 KVS-2020 End-of-line
Device
1 lb.
83-132016-001 KVS-2020 IR Test Kit 2 lb.
83-132017-001 KVS-2020 Backup Battery
Assembly,
5 lb.
83-100001-003 LHS (Linear Heat Sensing)
Cable 100 m Reel (328 ft.
approx.)
10 lb.
1.29
.46
2.72
5.25
4.76
4.25
1.50
ø.20 - 4 PLS
FIRE
ENGAGED
ALARM SILENCE
STOP
ENGINE
DELAY
TEST/RESET
SYSTEM OK
FIRE
413410
PROTECTION PANEL
ALARM TROUBLE
Figure 2. KVS-2020 Side View
4.75
1.00
J1
1.30
.10
2.30
MOUNTING POINTS-4PLS
R.50
CUTOUT
J1 Mating Connector is Deutsch DT06-12S
1.17
3.58
1.50
Kidde is a registered trademarks of Kidde-Fenwal, Inc.
3M and Novec are trademarks of 3M.
All other trademarks are property of their respective owners.