Kidde Fire Systems Smoke Alarm K 45 9049 Users Manual
2015-02-09
: Kidde-Fire-Systems Kidde-Fire-Systems-Kidde-Fire-Systems-Smoke-Alarm-K-45-9049-Users-Manual-568182 kidde-fire-systems-kidde-fire-systems-smoke-alarm-k-45-9049-users-manual-568182 kidde-fire-systems pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Kidde Engineered Fire Suppression System A UTC Fire & Security Company Designed for use with 3M™ Novec 1230™ Fire Protection Fluid Effective: April 2008 K-45-9049 Explosion Proof Solenoid, Electric Control Head Data Sheet FEATURES • • • Explosion Proof: – UL Listed as Suitable for Hazardous Locations Class I Div 1 Groups C and D Class II Div 1 Groups E, F and G FM Approved Compatible with UL Listed and FM Approved Suppression Systems: – FM-200® Systems, Including the ADS – Carbon Dioxide Systems – FE-13™ Systems • • • • • • Operated By: – Control Panel – Mechanical Manual Actuator Nominal 24 Vdc Operation Low Current Consumption Operates: – Cylinder Valves – Stop Valves – Directional Valves Wide Operating Temperature Range Rugged Brass Body P/N: 81-100000-001 DESCRIPTION The Explosion Proof Control Head is designed to operate FM-200 , ADS, Carbon Dioxide and FE-13™ cylinder valves, stop valves and directional valves. The Explosion Proof Control Head can be operated electronically from the Detection and Control system, or by local manual operation via an affixed manual control head. The Explosion Proof Control Head has a continuous current draw, which must be accommodated for at the Control Panel. The actuating pin latches in the released position and must be mechanically reset prior to re-arming the system. ® A suitable Control Panel, Listed and/or Approved for use with the Explosion Proof Control Head, shall be provided for supervision of the releasing circuit per NFPA requirements. The Explosion Proof Control Head is designed and rated for use in the following hazardous areas: Class I Division 1 Group C and D and Class II Division 1 Group E, F and G. INSTALLATION The Explosion Proof Control Head can be mounted directly on either the cylinder valve, stop/directional valve. WARNING 3.0 in. (76 mm) 7.8 in. (198 mm) Figure 1. Assembly Drawing Care should be taken to ensure that the actuating pin is in the set position when attaching the control head to the cylinder or the stop/directional valve. Accidental system discharge could occur, which could cause property damage, personal injury and/or death. Tighten the swivel nut securely in place. When installing the Explosion Proof Control Head in hazardous locations, wiring connections must be terminated in explosion proof junction boxes. The lead wires must be connected using the indicated polarity (red to positive, black to negative) in order to obtain correct operation. MAINTENANCE Regular scheduled maintenance should be performed on the Explosion Proof Control Head to ensure that the unit operates correctly if and when required. SPECIFICATIONS Part Number: Applications: 81-100000-001 FM-200, ADS, Carbon Dioxide and FE-13 Suppression Systems Approval/Listing: Releasing Device– HazLoc– HazLoc Ratings: MONTHLY The Explosion Proof Control Head should be inspected for any signs of physical damage, deterioration, corrosion, distortion, cracks, dirt ingress and loose couplings. Tighten any loose couplings. Replace damaged or missing caps. Replace control head if damage is found. Ensure that all explosion proof control heads are in the “set” position. SEMI-ANNUALLY The Explosion Proof Control Head should be tested for proper operation. WARNING All Explosion Proof Control Heads should be removed from agent cylinders (Carbon Dioxide, FM-200 or FE13) to avoid accidental system discharge, which could cause property damage, personal injury and/or death. Operating Voltage: Current Draw: At 24 Vdc– At 30 Vdc– Wiring Connections: Wire Size– Lead Length– Ambient Temperature: Construction: Material– Weight– Dimensions: This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product’s suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. © 2008 Kidde-Fenwal Inc. Printed in USA 270 mA continuous 500 mA continuous 18 AWG 36 in. (914 mm) -40°F to 130°F (-40°C to 55°C) Brass body 8.1 lb. (3.7 kg) 3 in. D x 7.8 in. L (76 mm D x 198 mm L) ORDERING INFORMATION Remove control heads from all master cylinders within the hazard area being tested. Let the Explosion Proof Control Head hang freely from the flexible electrical conduit connections. Operate the Explosion Proof Control Head, either by actuation at the system control panel or via manual operation of an electric pull station. Ensure that the control head has operated. Observe that the actuating pin has moved to the fully released position. If any control heads have not operated, check circuit for electric continuity. Replace all damaged control heads. Repeat operation test if any control heads have been replaced. Replace any damaged control head, which fails to reset properly. Make certain that electric control heads are in the set position before reconnecting to agent cylinders. Reattach all control heads to threaded ports on cylinder valves and tighten swivel nuts securely. K-45-9049 Rev AC UL, FM UL, FM Class I Division 1 Group C and D Class II Division 1 Group E, F and G 18 Vdc @ 0.20 A to 30 Vdc @ 0.50 A Part Number Description 81-100000-001 Explosion Proof Solenoid (Electric Control Head) 870652 Mechanical Manual Actuator 81-129958-001 Reset Tool Assembly A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Mode : UseNone XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Creator Tool : FrameMaker 7.1 Modify Date : 2008:04:11 10:34:18Z Create Date : 2007:01:16 09:11:07Z Format : application/pdf Title : K-45-9049.fm Creator : Bernice.Parker Document ID : uuid:f7f5719f-4182-47b9-bfdf-dcf569edb9c9 Instance ID : uuid:f2eb15f8-fa1e-4689-871e-5b3b6bd5eaf8 Page Count : 2 Author : Bernice.ParkerEXIF Metadata provided by EXIF.tools