Kidde Fire Systems Smoke Alarm K 73 06 Users Manual
2015-02-09
: Kidde-Fire-Systems Kidde-Fire-Systems-Kidde-Fire-Systems-Smoke-Alarm-K-73-06-Users-Manual-568183 kidde-fire-systems-kidde-fire-systems-smoke-alarm-k-73-06-users-manual-568183 kidde-fire-systems pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
LHS™ Linear Heat Sensor Effective: March 2013 K-73-06 FEATURES • • • • • Fixed Temperature Digital Heat Detector Five Alarm Temperatures Available: 142°F - 158°F, 180 °F, 220°F, 350°F, 452°F Compatible with All Fire Control Panels Connect Directly to Initiating Circuit Cost-Effective Solution for Hazardous Locations • • • Ideal for Use in Applications Where Spot-Type Heat Detectors are Unsuitable Fire Zone Location Using LHS with SmartOne®-compatible panels FM Approved DESCRIPTION The LHS™ Linear Heat Sensor cable is a flexible, durable and cost-effective fixed-temperature fire detector, suitable for protecting a wide range of commercial and industrial fire applications. LHS is a small diameter cable capable of detecting heat from a fire over its entire length. The sensor cable consists of a twisted pair of 19 AWG copper coated steel conductors covered by a temperature sensitive insulation, and protected by either a plastic braid or jacket for various environmental applications. The LHS Linear Heat Sensor is Factory Mutual Approved and is designed for open area as well as proximity detection. A wide range of jackets and operating temperatures are available for proper system design, including confined areas or harsh environments which prohibit the use of other forms of detection. LHS is compatible with any fire control panel that is capable of accepting contact closure type initiating devices. APPLICATIONS • Open Area Protection • Belt Conveyers • Tunnels • Aircraft Hangars • Cable Trays • Floating Roof Tanks • Classified Hazardous Areas (when used with intrinsic safety barriers) OPERATION The heat from a fire causes the LHS cable’s special insulation to melt at a specific temperature, allowing the two conductors to short together, thus creating an alarm condition on the fire control panel. The LHS cable may also be used as a stand-alone contact device. The LHS normal operating state is an open circuit. For installation details refer to “LHS Installation Instructions” (73-202). Conductor Tinned copper-covered steel Insulation Temperature-sensitive thermoplastic or fluoropolymer Jacket Thermoplastic strip braid, PVC, nylon, or fluoropolymer FIRE ZONE LOCATION WITH LHS An Intelligent Linear Heat Detection System is recommended for applications where fire zone location requires zone output control for notification appliances, HVAC control, suppression control and annunciation. In this system, each discrete addressable LHS cable zone will report an individual alarm to the SmartOne®-compatible fire control panel. Addressable LHS cable zones are created by attaching each LHS cable zone to an Addressable Input module (P/N 70-407008-001). Each discrete LHS cable zone location can be displayed on the SmartOne-compatible panel 80-character LCD display with programmable text zone description. Up to 255 devices (any mix of devices including smoke detectors, manual pull stations, waterflow switches, LHS zones, etc.) can be connected to a single SmartOne-compatible’s addressable loop. Installing an Intelligent Linear Heat Detection System results in substantial installation cost savings over traditional hard-wired linear heat detection systems. Table 1: LHS Sensor Cable Specifications Part Number: 656 ft (200 m) length roll 3,280 ft (1000 m) length roll Alarm Temperature Range 73-200000-011 73-201000-011 73-200000-012 73-201000-012 73-200000-003 73-201000-003 73-200000-004 73-201000-004 73-200000-005 73-201000-005 145-158ºF (63-70ºC) 180ºF (82ºC) 220ºF (105ºC) 350ºF (177ºC) 452F (233ºC) Up to 221ºF (105ºC) Up to 392ºF (200ºC) Ambient Storage Temp.* Up to 113ºF (45ºC) Min. Installation Temp. 5ºF (-15ºC) Min. Operating Temp.** -40ºF (-40ºC) Application Indoor/Outdoor Up to 158ºF (70ºC) 32ºF (0ºC) Indoor/Outdoor Approved Spacing Indoor/Outdoor Indoor/Outdoor Indoor/Outdoor 12 seconds (max) Nylon Nylon Outer Jacket Color Black Marked H8040N Black Marked H8045N Conductor Insulation 20 seconds (max) PVC EVA 0.13 in. (3.35 mm) 0.13 in. (3.35 mm) Electrical Rating FEP Black Red Polythene Polypropylene FEP 1 Black 1 Black/White 1 Black 1 White 0.17 in. (4.35 mm) 0.14 in. (3.5 mm) 1 Black 1 Red Conductor Color 0.17 in. (4.35 mm) 30.48 ohms/1000 ft. @ 68ºV (100 ohms/1000 m) @ 20ºC 20.21 pF/ft. (66.32 pF/m) Insulation Rating 25.42 pF/ft. (83.31 pF/m) 19.96 pF/ft. (65.48 pF/m) 17.52 pF/ft. (57.48 pF/m) 19.22 pF/ft. (63.07 pF/m) 1000 megohm per 3280 ft. (1000 m) after 1 minute @ 500 Vdc Minimum 10.65 lb./1000 ft. (15.85 kg/km) 10.65 lb./1000 ft. (15.85 kg/km) 15.25 lb./1000 ft. (22.7 kg/km) 12.67 lb./1000 ft. (18.85 kg/km) *Do not store in direct sunlight. **When not subjected to vibration. SmartOne and Kidde are registered trademarks of Kidde-Fenwal, Inc. LHS is a trademark of Kidde-Fenwal, Inc. This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product’s suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. K-73-06 Rev AC White 1 Amp maximum, 110 Vdc maximum Conductor Resistance Weight -58ºF (-50ºC) Proximity Detection 5 seconds (max) Outer Jacket Material Conductor Capacitance -40ºF (-40ºC) 20 ft (6m) max Flame Detection External Diameter -4ºF (-20ºC) -22ºF (-30ºC) © 2013 Kidde-Fenwal Inc. 400 Main Street Ashland, MA 01721 Tel.: 508-881-2000 Fax: 508-881-8920 www.kiddefiresystems.com 14.65 lb./1000 ft. (21.8 kg/km)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2007:01:16 09:11:07Z Creator : FrameMaker 10.0.2 Modify Date : 2013:03:18 11:13:36-04:00 Language : en XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/10/03-12:08:50 Producer : Acrobat Distiller 10.1.5 (Windows) Creator Tool : FrameMaker 10.0.2 Metadata Date : 2013:03:18 11:13:36-04:00 Format : application/pdf Title : untitled Document ID : uuid:878b9aaa-77a5-4c82-9034-3920b170743f Instance ID : uuid:06f23e65-96df-41a8-9e83-cef086435407 Page Mode : UseNone Page Count : 2EXIF Metadata provided by EXIF.tools