Kitchenaid KESC308LSS0 User Manual IN RANGE ELECTRIC Manuals And Guides L0503056

KITCHENAID Free Standing, Electric Manual L0503056 KITCHENAID Free Standing, Electric Owner's Manual, KITCHENAID Free Standing, Electric installation guides

User Manual: Kitchenaid KESC308LSS0 KESC308LSS0 KITCHENAID -IN RANGE - ELECTRIC - Manuals and Guides View the owners manual for your KITCHENAID -IN RANGE - ELECTRIC #KESC308LSS0. Home:Kitchen Appliance Parts:Kitchenaid Parts:Kitchenaid -IN RANGE - ELECTRIC Manual

Open the PDF directly: View PDF PDF.
Page Count: 12

®
HOME APPLIANCES
II " " 9758646
e
Freestanding
Range
Tip Over Hazard
A child or adult can tip the range and
be killed.
Connect anti-tip bracket to rear
range foot.
Reconnect the anti-tip bracket, if the
range is moved.
Failure to follow these instructions can
result in death or serious burns to
Quick Reference
Table of Contents:
Pages
%-_
[]
[]
Before you start
Product dimensions
Cabinet dimensions requirements
EUectdcaUrequirements
HnstaHationsteps
Check operation
Ufrange does not operate
If you need assistance'service
Moving the range
children and aduIts.
www.Mtchenaid.com
Read and save these instructions.
iMPORTANT:
installer: Leave HnstaHation
Instructions with the homeowner.
Homeowner: Keep Installation
Instructions for future reference,
Read and save these instructions
for local electrical inspector's use.
Write down the model and serial
numbers before installing range.
Both numbers are listed on the
model/serial rating plate located
on the oven frame behind the
storage drawer panel
Model #
Serial # Part No. 9758646
Before you start...
Your safety and the safety of
others are very important.
We have provided many important safety
messages in this manual and on your
appliance. Always read and obey all
safety messages.
This is the safety alert symbol.
This symbol alerts you to
potential hazards that can kill
or hurt you and others.
All safety messages will follow the safety
alert symbol and either the word
'DANGER" or 'WARNING." These
words mean:
You can be killed or seriously injured
if you don't immediatebL follow
instructions.
You can be kitied or seriously injured
if you don't follow instructions.
All safety messages will tell you what the
potential hazard is, tell you how to
reduce the chance of injury, and tell you
what can happen if the instructions are
not followed.
IMPORTANT: Observe all governing codes
and ordinances. Failure to meet codes
and ordinances could lead to fire or
electrical shock.
Proper installation is your responsibility.
A qualified technician must install this
range. Make sure you have everything
necessary for correct installation. It is the
installer's responsibility to comply with
installation clearances specified on the
model/serial rating plate.The model/serial
rating plate is located on the oven frame
behind the storage drawer panel.
Check location where range will be
installed.The range should be located for
convenient use in kitchen.
To eliminate the risk of burns or fire by
reaching over heated surface units,
cabinet storage space located above the
surface units should be avoided. If
cabinet storage is to be provided, the risk
can be reduced by installing a range
hood that projects horizontally a
minimum of 5 inches beyond the bottom
of the cabinets.
All openings in the wall or floor where
ranges is to be installed must be sealed.
Cabinet opening dimensions that are
shown must be used. Given dimensions
are minimum clearances.
Grounded electrical outlet is required.
See "Electrical requirements" section.
Mobile home installation
The installation of this range must
conform with the Manufactured Home
Construction and Safety Standard,Title
24 CFR, Part 3280 [formerly the Federal
Standard for Mobile Home Construction
and Safety, Title 24, HUD (Part 280)] or,
when such standard is not applicable, the
Standard for Manufactured Home
Installations, ANSI A225J/NFPA 501A *,
or with local codes.
When this range is installed in a mobile
home, it must be secured to the floor
during transit. Any method of securing
the range is adequate as long as it
conforms to the standards listed above.
Four-wire power supply cord or cable
must be used in a mobile home
installation.The appliance wiring will
need to be revised. See "Four-wire
electrical connection" section.
The floor anti-tip
bracket must be
installed.To install
the anti-tip bracket
shipped with the
range, see Page 5 and
the anti-tip bracket template.
Copies of the standards listed may be obtained
from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts, 02269
Tools needed:
Follow all factory safety instructions
included with your tools.
level
fiat-blade screwdriver
3/8" drive ratchet
3/8" and 5/16" nut drivers
hand or electric drill
channel lock pliers
measuring tape or ruler
wood floors: 1/8" drill bit
concrete/ceramic floors:
3/16" carbide-tipped masonry drill bit
(Hammer may be needed for anchors,)
Parts supplied:
Not shown:
literature pack
2 plastic
anchors
2 screws floor-mounted
(#10 x I-1/2") anti-tip bracket
Brackets must be securely mounted to sub-floor,
Thickness of flooring may require longer screws to
anchor bracket to sub-floor, Longer screws are
available from your local hardware store.
Product dimensions
8-1/4"
(21.0 cm)
Freestanding Range When installed in a 24" (61.0 crn)
base cabinet with 25" (63.5 crn}
30" (76.2 cm) j/_ countertop, front of oven door
coo<top w dth protrudes 1-7/8"' (4.8 cm) beyond
24" (61.0 crn} base cabinet.
44-3/8"
{112.7 cm)
overall
hek ht
36" (91.4 cm)
cooktop
height with
feet loosened
1-1/2turns
1" (2.5 cm)
spacer
36" (91.4 cm)
cooktop
height with
feet loosened
1-I/2 turns
1
SUide4n Range
90" (76.2 cm)
cooktop w dth
27-3/4" (70.4 c_..... 30" (7&2 cm) 30" (7&2 crn) ,width
depth with handle /. _width /
28" (71.1 cm) _ /depth with handle /
depth with handle 26" (66.0 cm) \_
(stainless steel models) depth with handle
(stainless steel models)
Cabinet -''------e menslens/requlremenrs Cab oetopeo o d mens ooashow°arefor:
25" (63.5 crn) countertop depth, 24" (61.0 crn) base
cabinet depth, 36" (91.4 crn) countertop height
Freestanding Range
minimum
I rna_: upper, clearance to
j caome[ _ep[n the top of the
_._/ ..... _ .,_cooktop, see
18" (45.7 crn) '
upper side cabinet
to counterto
I
4" (10.2cm) rain. _v-_
clearance from /"
both sides of
range to side
wall or other
combustible
material
I i
I .4 _
\
I
4" (10.2 cm) _1_
mh'L clearance _
/iunct[on box - 8" (20.3 cm) from both sides
to 22" (55.9 cm) from either of range to side
cabinet. 7" (!7.8 cm) max. wall or other
from floor, combustible
._ material _
R0
I
I .jt
7/8" (2.2 cm) _ .i
required \
between cutout \ \
and cabinet \
door or hinge. \
Slide-in Range
13" (33
_nO"n!7c6a:i,cemt)-
1 ./457 ,/f opon,ng
upper side cabinet
to countertop 1/2" (!.3 cm)
radius both
corners 30" (76.2 cm)
width
For minimum
clearance to
the top of the
cooktop, see
NOTE.*
22-3/4" (57.8 cm)
[ depth
iunction box - 8" (20.3 cm)
to 22" (55.9 cm) from either
cabinet. 7" (!7:8 cm) max.
from floor.
7/8" (2.2 cm)
rain.required
between cutout
and cabinet
door or hinge.
*NOTE: 24" (61 cm) rain. when bottom of wood or metal cabinet is
protected by not less than 1/4" (6.4 ram) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 ram)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) m[n. clearance between the top of the cooking platform
and the bottom of an unprotected wood or metal cabinet. 3
Slide@ ranges:
countertop
preparations
The cooktop sides of the siideqn range fit
over the cutout edge of your countertop+
If you have a square finish (fiat)
countertop and the opening width is 30"
(76+2 cm), no countertop preparation is
required+
Formed front-edged countertops: Must
have moiled edge shaved fiat 1/2" (1+3
cm) from each front corner of opening+
THe countertops may need trim cut back
1/2" (1+3 cm) from each front corner
and/or rounded edge flattened,
30-7/8" (78.4 cm)
FoOrmedor tiled
untertop trimmed
1/2" (1.3cm) back at
front corners of
countertop opening.
22-6/8"
(57.5cm)
Cooktop sides of i j_
range fit over edges of j
countertop opening. _
If countertop opening width is greater
than 30" (76.2 cm), adjust the 1/2" (1+3
cm) dimension+
Countertop must be ieveL Piace ievei on
countertop, first side to side; then front
to back. if countertop is not ievei, range
will not be level+ Oven must be level for
satisfactory baking conditions+
Electrical requirements
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path and wire gauge are in
accordance with local codes,
This range must be connected to a
grounded metal, permanent wiring
system.
Check with a qualified electrician if you
are not sure range is properly grounded+
Do not ground to a gas pipe+
Do not have a fuse in the neutral or
ground circuit+
Range must be connected to the proper
electrical voltage and frequency as
specified on the model/serial rating plate+
(The model/serial rating plate is located
on the oven frame behind the storage
drawer panel+)
[_ A four-wire or three+wire, single+
phase, 120/240+volt, 60-Hz, AC+only,
electrical supply (or three+wire or four-
wire 120/208+volt if specified on the
model/serial rating plate) is required on a
separate, 40 amp circuit, fused on both
sides of the line+
A time-delay fuse or circuit breaker is
recommended.
The range can be connected directly
to the fused disconnect (or circuit breaker
box) through flexible armored conduit+
This range can be direct wired to a four-
wire or three-wire aluminum wiring
system. See "Direct wire method: Copper
or Aluminum wire" section+
Allow two to three feet of slack in the line
so that it can be moved if servicing is
ever necessary.
A U+h+listed conduit connector must be
provided at each end of the power supply
cane (at the range and at the junction
box).
Wire sizes and connections must conform
with the rating of the range (40 amps)+
[_ The wiring diagram is located on the
back of the range or on the inside of the
storage drawer in a clear plastic bag.
Recommended ground method
tt is the personal responsibility and
obligation of the customer to contact a
qualified electrician to assure that the
electrical installation is adequate and is in
conformance with the National Electrical
Code, ANSt/NFPA 70 -- latest edition +x
and aii local codes and ordinances+
Power supply cord is not supplied, but is
available through your local electrical
supply house+
ff connecting to a four-wire
system:
This range is manufactured with the
ground connected to the cabinet.The
ground must be revised so the green
grounding wire of the fouFwire power
supply cord is connected to the cabinet.
See "Four-wire electrical connection"
section+
When a fouFvvire receptacle of NEMA
Type 14-50R is used (see Figure 1, below),
a matching U.h-listed, four-wire, 250-volt,
40 amp, range power supply cord (pigtail)
must be used+This cord contains four
copper conductors with either ring
terminals or spade terminals with
upturned ends to connect the power
supply at the appliance end, terminating
in a NEMAType 14-50P plug on the
supply end+The fourth (grounding)
conductor must be identified by a green
or green_yellow cover and the neutral
conductor by a white cover. Cord should
beType SRD or SRDT with a U.L-listed
strain relief and be at bast four feet long+
The minimum conductor sizes for the
copper four-wire power cord are:
40 amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No+-8 green grounding
ff connecting to a three-wire
system:
Local codes may permit the use of a
U+L.+listed, 250-volt, 40 amp range power
supply cord (pigtaib+This cord contains
three, No++10 copper wires and matches
a three+wire receptacle of NEMAType
10-50R, shown in Figure 2. Connectors on
the appliance end must be provided at
the point the power supply cord enters
the appliance.
4-wire wall
receptacle (!4-50R)
Figure 1
3-wire wall
receptacle (!0-50R)
Figure 2
Copies of the standards listed may be obtained
from:
*National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts, 02269
New start...
Excessive Weight Hazard
Use two or more people to move and
install range.
Failure to do so can result in back or
other injury.
I M Remove shipping materiab, tape
and protective film from range. Keep
cardboard bottom and shipping base
under range, Remove oven racks and
parts package from inside oven.
Take four cardboard corners from the
carton. Stack one cardboard corner on
top of another, Repeat with other two
corners. Piace them bngthwise on the
floor behind the range --to support the
range when it is iaid on its back
R Firmiy grasp the range and gently
Hay it on its back on the cardboard
corners.
Pull cardboard shipping base
firmiy to remove.
5[] Use an adjustable wrench to
loosen the leveling legs four complete
turns.
Piace
cardboard or
hardboard in front
of range. Stand range
back up onto cardboard or hardboard.
Tip Over Hazard
A child or aduJt can tip the range and
be kiJ[ed,
Connect anti-tip bracket to rear
range foot.
Reconnect the anti-tip bracket, if the
range is moved.
Failure to follow these instructions can
result in death or serious burns to
children and adults,
Contact a qualified floor covering installer
for the best procedure for drilling
mounting holes through your type floor
covering,
screws may be
necessary to
anchor the bracket
to the sub-floor. Longer
screws are available from your
local hardware store,
Check that range is on cardboard
shipping base to protect floor covering.
EJectricaJ connection
Remove the terminal block cover
located on the back of range.
,irmJTi-- -
block cover
9m Depending on your electrical
supply, make the fouFwire or three-wire
connection to the range following the
"Power supply cord method" or "Direct
wire method" instructions for copper
wire or aluminum wire depending on the
connection needed.
knockout
opening fo _...
40 amp
power
supply cord
knockout
opening
for power
supply
cable
f
Power suppJy cord method:
NOTE: The bag containing three
aluminum terminal lugs is not used
when connecting the range using a
power supply cord.
Electrical Shock Hazard
Disconnect power before servicing.
Use new 40 amp power supply cord.
Plug into grounded outlet.
Failure to follow these instructions can
result in death, fire, or electrical shock.
5_
6_
Use either ring-type terminals or
spade terminals with upturned ends
to connect the power supply.
Complete electrical connection
according to your type electrical
supply ("Four-wire electrical
connection" or "Three-wire electrical
connection[')
Four-wire electricaJ connection:
_ourtd
o ground-link
screw
10. Connect the neutral wire (center wire)
to the center terminal screw on the
terminal block. See Figure 2.
11. Connect the other two wires dines 1
and 2) to the outer screws on the
terminal block. See Figure 2.
12. Securely tighten nuts with 3/8" nut
driver for proper electrical
connection,
l& Tighten the strain relief screws,
14. Replace the terminal block cover.
15. Plug power supply cord into
grounded electrical outlet.
Three-wire eJectricaJ
connection:
center
WARNING -Improper connection of the
equipment-grounding conductor can
result in a risk of electric shock. Check
with a qualified electrician or serviceman
if you are in doubt as to whether the
appliance is properly grounded. Do not
modify the power supply cord plug, If it
will not fit the outlet, have a proper outlet
installed by a qualified electrician.
This range is manufactured with the
neutral terminal connected to the cabinet.
Use a three-wire, U.h-listed, 40 amp
power supply cord (pigtail); or if local
codes Do not permit ground through the
neutral, use a four-wire power supply
cord rated at 250 volts, 40 amps and
investigated for use with ranges. (See
"Four-wire electrical connection/')
remove Imockout
for 40 amp _-_
power cord
and U.L. listed
strain relief
opening for
conduit
cormector
/
1. Disconnect power.
2. Remove the knockout for the 40 amp
power supply cor&
3. Assemble a U.h-listed strain relief in
the opening.
4. insert the power supply cord through
the strain relief, allowing enough
slack to easily attach the wiring to the
terminal block,
Figure1
neutral wire
(centerwire) center
block screw
"ound link
line rounddink
screw
green -
ground _ line 2
wire
U.L listed strain relief
and 40 amp range
power supply cord
Figure 2
Use this method for new installations,
mobile homes, recreational vehicles and
whenever four-wire installation is
required,
7. Remove the ground-link screw from
the range frame, Save the ground-link
screw, Bend up the ground link so
that it does not contact the range. See
Figure 1.
8. Connect the green ground wire from
power supply cord to the range using
the ground-link screw, The ground
wire must be attached first and must
not contact any other terminal See
Figure 2.
9_ Use 3/8" nut driver and remove the
outside nuts on the terminal block
screws. Do not loosen the factory-
tightened nuts behind the outside
nuts.
block screw
ground-
link
line
(center wire)
2
relief
and 40 amp range
power supply cord
Figure 3
Use this method only if local codes
permit connecting cabinet-ground
conductor to neutral wire of power
supply cord.
7. Use 3/8" nut driver and remove the
outside nuts on the terminal block
screws, Do not loosen the factory-
tightened nuts behind the outside
nuts_
8. Connect the neutral wire (center wire)
to the center terminal screw on the
terminal block, See Figure 3,
9. Connect the other two wires dines 1
and 2} to outer terminal screws on the
terminal block, See Figure 3.
10. Securely tighten nuts with 3/8" nut
driver for proper electrical
connection.
11. Tighten the strain relief screws,
12, Replace the terminal block cover.
13. Plug power supply cord into
grounded electrical outlet.
Direct wire method: Copper or AJuminum wire
NOTE:The bag containing three
aiuminum terminai Hugs must be used
when making a direct wire connection.
Emectrica[ Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire, or 6 gauge
aluminum wire.
Electrically ground range.
Failure to follow these instructions can
result in death, fire, or electrical shock.
This range may be connected directiyto
the fuse disconnect or circuitbreaker box;
or with a U+L+-Hsted, 40 amp range power
suppiy came+ Depending on your
eiectrisa[suppiy, make the required
three-wire or four-wire connection+
1. Disconnect power.
2. Remove the knockout as needed for
conduit connection.
Assemble a
U.L,-listed
conduit
connector in
opening+
4. Strip outer covering back 3 inches to
expose wires. Strip the insulation back
1 inch from the end of each wire.
I
5.
6.
Allow enough slack in the wire to
easily attach the wiring terminal
block.
Use 3/8" nut driver and remove the
outside nuts on the terminal block
screws+ Do not loosen the factory-
tightened nuts behind the outside
nuts+
__terminal
[ _ set screw
[ must face out
XIMPORTANT: the aluminum terminal
lugs must be assembled to the
terminal posts with the set screws
facing out as shown+
8+ Attach three aluminum terminal lugs
to terminal posts+
Use a 3/8" nut driver and tighten the
nuts securely+ Nuts must be
tightened to 20 in/Ibs of torque for
proper electrical connection.
9+ Complete electrical connection
according to your type electrical
supply ("Four-wire electrical
connection" or "Three+wire electrical
connection[')
Figure 1
lineI
green_
ground
wire
_ted
+en,erw,re>
Figure 2
Use this method for new installations,
mobile homes, recreational vehicles and
whenever four-wire installation is
required.
10+ Remove the ground-link screw from
the range frame. Save the ground-link
screw and cup washer+ Bend up the
ground link so that it does not contact
the range. See Figures 1 and 2+
11. Connect the green ground wire to the
range using the ground-link screw
and cup washer.The ground wire
must be attached first and must not
contact any other terminal See
Figure 2+
15.
16+
12. Loosen (do not remove) the 3 slotted
set screws+ insert the neutral (white)
wire into the hole at the Bottom of
the center position lug (attached to
center terminal screw black terminal
block)+ See Figure 2.
13. Connect the other two wires dines 1
and 2) to the outer aluminum lugs.
14. Securely tighten the set screws.
For 8 gauge copper wire, tighten to
25 in/Ibs of torque, and for 6 gauge
aluminum wire, tighten to 35 in/Ibs of
torque to make a proper electrical
connection+ See Figure 2.
Tighten the locking ring of the
conduit connector.
Replace the terminal block cover+
Three-wire electdea[
connection:
_tted
_;_?_ set screw
_ _ @j 'qT_ neutral
Figure 3
Use this method only if local codes
permit connecting ground conductor to
neutral supply wire+
10+ Loosen (do not remove) the 3 slotted
set screws+ Insert the neutral (white}
wire into the hole at the bottom of the
center position lug (attached to center
terminal screw of terminal block). See
Figure 3+
11. Connect the other two wires dines 1
and 2) to the outer aluminum lugs+
12+ Securely tighten the set screws.
For 8 gauge copper wire, tighten to
25 in/ibs of torque, and for 6 gauge
aluminum wire, tighten to 35 in/Ibs of
torque to make a proper electrical
connection+ See Figure 3+
13+ Tighten the locking ring of the conduit
connector+
14. Replace the terminal block cover.
Operating position
Move range chose to cabinet
opening.
Remove cardboard or
hardboard from under range. Carefully
move range into final position.
I M Pull drawer open to first stop
position. Lift front of drawer to clear
white wheels in drawer guides. Remove
drawer and set it aside on a protected
surface.
m Make sure the anti-tip bracket
is installed:
• Look for the anti-tip bracket securely
attached to floor.
• Slide range back so rear range foot
is under anti-tip bracket.
anti-tip
bracket
range foot
R If installing the range in a
mobile home, you must secure the range
to the floor. Any method of securing the
range is adequate as long as it conforms
to the standards in the "Mobile home
installation"section.
Place rack in oven. Place level
on rack, first side to side; then front to
back
If range is not level, pull range forward
until rear leveling leg is removed from
the anti-tip bracket. Use 3/8" drive ratchet
and channel lock pliers to adjust leveling
legs up or down until range is level. Push
range back into position. Check that rear
leveling leg is engaged in anti-tip
bracket.
NOTE: Oven must be level for
satisfactory baking conditions.
m Replace the storage drawer or
lower panel.
[] Reconnect power.
Check operation
7[] Check the operation of the
cooktop eiements:
Push in and turn OFF
each surface unit o
controi knob to "Hi"
position. Check the
operation of the
cooktop eiements _
and indicator lights. %MED
M Check the operation of the oven
element:
Press the "BAKE" pad. "350°F " wiii
appear in the temperature display. Press
the "START" pad, "LO" will appear in the
display; then "170°F " (when oven reaches
170°F).
NOTE: Control panels may vary.
The bottom element should glow red and
the indicator light should be on.The
upper element should become hot but
not glow red. As the oven temperature
rises, the temperature in the display will
increase in 5°F increments until the oven
reaches the set temperature.
Press "CANCEL/OFF" pad.
[] Check the operation of the
broil element. Close the oven door. Press
the "BROIL' pad, "500°F '' wiii appear in
the temperature display. Press the
"START" pad.
Look through the oven window.The top
element should glow red. Press the
"CANCEL/OFF" pad.
qC3
83{383
CLOCK 1SET,START
You have just finished installing
your new range.To get the most
efficient use from your range,
read your Use & Care Guide.
Keep Installation Instructions and
Guide cJose to range for easy
reference. The instructions wilt
make installing the range in
another home as easy as the first
installation.
/f range does not
operate:
[_ Check that the circuit breaker is not
tripped or the house fuse blown.
[_ Check that the power supply cord is
plugged into the outlet.
[_ See Use and Care Guide for
troubleshooting list,
/f you need assistance:
if you have questions about operating,
cleaning or maintaining your range:
[_ Refer to Use and Care Guide.
[_ The KitchenAid Customer interaction
Center wiii answer any questions
about operating or maintaining your
range not covered in the Installation
Instructions.The KitchenAid
Customer interaction Center is open
24 hours a day, 7 days a week. Just
dial 1-800-422-1230 -the cail is free
within the continental United States.
When you call, you wiii need the
range model number and serial
number. Both numbers can be found
on the model/serial rating plate
located on the oven frame behind
the door.
If you need service:
in the event that your KitchenAid
appliance should need service, call the
deabr from whom you purchased the
appliance or a KitchenAid-authodzed
service company. A KitchenAid-
authorized service company is listed in
theYellow Pages of your telephone
directory under "Appliances - Household
- Major- Service & Repaid'You can also
obtain the service company's name and
number by dialing, free within the
continental United States, the KitchenAid
Customer Interaction Center telephone
number, 1-800-422-1230. A special
operator will tell you the name of your
nearest KitchenAid-authorized service
company.
Maintain the quality built into your
KitchenAid appliance -- call a
KitchenAid-authorized service company.
Moving the range
Tip Over Hazard
A child or adult can tip the range and
be kiHed.
Connect anti-tip bracket to rear
range foot.
Reconnect the anti4ip bracket, if the
range is moved.
Failure to follow these instructions can
resumt in death or serious burns to
children and adults.
When moving range, slide range onto
cardboard or hardboard to prevent
damaging the floor covering,
If removing the range is necessary for
cleaning or maintenance:
1. Unplug range or disconnect power.
2. Slide range forward to complete
cleaning or maintenance.
3. Make sure the anti-tip bracket is
installed:
Look for the anti4ip bracket securely
attached to floor.
Slide range back so rear range foot
is under anti4ip bracket.
_ anti-tip
"X._S'_'._ bracket
range foot
4. Check that range is level.
5. Plug in range or reconnect power.
10
Notes
11
Part No. 9758646
© 2004 KitchenAid
® RegisteredTrademark of KitchenAid.
i :che HOME APPLIANCES
Prepared by KitchenAid, Benton Harbor, Michigan 49022
Printed in U.S.A.
0!/2004
Page 1 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056
Page 2 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056
Page 3 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056
Page 4 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056
Page 5 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056
Page 6 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056
Page 7 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056
Page 8 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056
Page 9 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056
Page 10 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056
Page 11 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056
Page 12 of 12 - Kitchenaid KESC308LSS0 User Manual  -IN RANGE - ELECTRIC Manuals And Guides L0503056

Navigation menu