Koden Electronics RB714A Marine Radar RA40C User Manual 10
Koden Electronics Co., Ltd Marine Radar RA40C 10
Contents
10
5.5.2 Nav (Navigation) Menu xxx = keys to press Radar functions for navigation aid are in this menu. •Common operations for the NAV menu (Up to the point when "NAV" menu is selected from the main menu) Press the "MENU" key and select "NAV" from the displayed 4 main menus using the left-right cursor. (The contents of the selected MENU will appear on a pull-down display in accordance with the movement of the left-right cursor.) MENU → Left/Right (Select NAV) Further explanation about the NAV menu will be conducted on the assumption that this "common operation for the NAV menu" has already been completed. 5.5.2.1 Changing display mode (MODE) (1) Select MODE from the pull-down display items using the up-down cursor key, and press either the "ENT" key. (2) When the MODE sign is displayed beside the MODE item, select a mode with the up-down cursor keys and press the "ENT" key. (3) The display mode indicates upper-left on the screen. .75 .25 HU NAVIGATION AT MARK >>> 0.23 NM NAV ECHO MODE GZ OFF-C SLEEP SETUP HU HS NU CU TM UP/DOWN --> ••• •Select MODE• --> UP/DOWN |--> (Select HU• --> ............ ••• •••Head up• |--> (Select HS• --> ............ ••• •••Head set• |--> (Select NU• --> ............ ••• •••North up• |--> (Select CU• --> ............ ••• •••Course up• --> (Select TM• --> ............ ••• ••(True motion) Note1: Navigation equipment (gyrocompass, magnet compass, or GPS) must be connected to your radar in NU, CU and TM modes. Note2: In TM modes it is necessary to set as follow (1) or (2). (1) Input of speed information from NMEA. (2) Set your ship’s speed manually. Note3: TM works only on PPI screen, NU is used automatically for the other screens. 52 5.5.2.2 Guard Zone (GZ) A function that sets a guard zone of any distance and any angle range, creating alarm tone when either echoes above a certain level exist (IN MODE) or no echoes exist(OUT MODE). Setting guard zone (1) Select GZ from the pull-down display items using the up-down cursor keys, and press the “ENT” key. ON/OFF sign is displayed beside the GZ item. Up/Down (2) --> ENT ------------------------------- ON/OFF sign is displayed. Select “ON” by “common operation for the GZ menu”, and press the “ENT” key. (3) The present mode setting will be displayed on the left side of the screen as GZ IN. A small cross cursor for setting the guard zone will be displayed at the screen center while "SET CENTER POINT" GZ IN is displayed at SET CENTER POINT the bottom, activating a guard zone setting state. (4) Use the up-down and left-right cursor keys to move the cross cursor to the center of the warning zone to be set, and press the "ENT" key. (5) From the cross cursor position set in (4) above as the center, expand the guard zone as follows. Expand with the right cursor key in the direction of the angle. Use the left cursor key to make the zone The central position of the guard zone. With this point as the center, the zone can be expanded in the directions of the distance and the angle with the upper and right cursor keys GZ IN Expand with the up cursor key in the direction of the distance. Use the down cursor key to make the zone smaller. The mode (IN or OUT) is displayed when the state is ON. Nothing is displayed when it is OFF. (6) After the setting the guard zone, finish by pressing the "ENT" key. To cancel the guard zone function, select “OFF” by “common operation for the GZ menu”, and press the “ENT” key. ENT --> Up/Down & Left/Right --> ENT --> Up/Down & Left/Right •--> ENT ---------------- Setting completed (Setting the center of GZ) (Setting the scope of GZ) 53 ----------------------------------------- Stop the alarm tone When the alarm sounds, press any key to stop. But the guard zone function is still working, the alarm may sounds again. To "OFF" the guard zone function, select "OFF" from GZ menu. Note1: To switch the IN or OUT mode, refer to “Guard Zone Mode” in section 5.5.4.5.3 “Changing the content of settings 2 (PRESET2)” Note2: To set the guard zone level, refer to “Guard Zone LeveL” in section 5.5.4.5.3 “Changing the content of settings 2 (PRESET2)” 5.5.2.3 Shifting display in specific direction (OFF-C) Displaying the location specified by the cross cursor as the vessel's location. (1) Select OFF-C from the pull-down display items using up-down cursor key, and press the "ENT" key. (2) When the ON/OFF sign is displayed beside the OFF-C item, select ON with the up-down cursor keys and press the "ENT" key. (3) OFF-C is displayed at the upper right and "SET OFF CENTER POINT" at the bottom of the screen, and setting is ready to be entered. Move the cross cursor with the cursor keys to move the ship’s to the intended location, and press the "ENT" key. The ship’s location will be displayed at the cursor's location. The display at the upper right will be normalized from the reverse state, which indicates that the "OFF-C" state is entered. (4) To cancel “OFF-C” function, either select OFF in (2) Up/Down --> ENT (Select OFF-C) --> Up/Down |-->(Select ON) ENT --> Left/Right & Up/Down --> ENT Set -->(Select OFF) ENT OFF-C ----------------------------- Cancel OFF-C Note: VRM2 and EBL2 do not follow the OFF-C function while floating. The function operates only Move the cross cursor .75 on PPI screen. indicates "OFF-C" state is entered .75 .25 HU .25 HU OFF-C SET OFF-C POINT 5.5.2.4 Setting of the SLEEP function(SLEEP) This function sends a 30-second-transmissions during pre-fixed hours. After a transmission, a power-saving mode is entered with the screen in ST'BY state (the scanner-OFF 54 state) and the LCD backlight turned off. This action is repeatedly executed. Usage example, set a guard zone and have the warning signal automatically confirmed every prefixed period. (1) Use the up-down cursor keys to select SLEEP from among the pull-down display items, and press the "ENT" key. (2) When the OFF/5min/10min/15min display has appeared beside the SLEEP item, select a time to be set with the up-down cursor keys. (3) Press the "ENT" key and the setting is completed. When the SLEEP function is to be canceled, select OFF in (2). When a transmission is conducted after setting a SLEEP mode, a ST'BY state is entered and the backlight turns off after a 30-second-transmission. (Power-saving mode). Two minutes before the fixed time the backlight turns on and the 2-minute timer starts. Then, at the fixed time another 30-second-transmission begins. This series of actions are repeated. If any one key is pressed during the course of this action, the SLEEP function will be canceled. (a) Setting procedure Up/Down → → ENT Up/Down -->Select OFF) → -----------SLEEP function is turned OFF -->(Select 5min.) ------------------------------- → (Select SLEEP) ENT ENT → POWER 30-second-transmission every 5 min. -->(Select 10min.) → ENT → ------------------------ POWER → ENT → ----------------------- POWER 30-second-transmission every 10 min. -->(Select 15min.) 30-second-transmission every 15 min. Transmission Setting completed (b) Action after setting SLEEP setting•5min.• • •(Under Tx• • •Operation• (Under power-saving mode• • •2min. timer in use• •(Under Tx• ••(Under power-saving mode• 0 sec. 30 sec. 3 min. 5min. 5and a half min. •Time used• TX Start TX OFF Backlight ON Countdown start Tx Start TxOFF •Action• -- What happens if a key is pressed after a SLEEP mode setting? If a transmission is conducted and a key is pressed after setting a SLEEP mode, powersaving mode is entered 30 seconds after key is pressed. -- What happens if a key is pressed during the SLEEP mode? a) If a key is pressed during the power-saving mode, the SLEEP function is canceled and the 2minute timer starts. 55 b) If a key is pressed while the 2-minute timer is in use, or during transmission , the SLEEP function is canceled. 56
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 2000:07:28 06:33:36 Producer : Acrobat Distiller 4.0 for Windows Modify Date : 2000:07:28 06:33:37-04:00 Page Count : 5EXIF Metadata provided by EXIF.tools