LCN 4310ME Installation Guide LCN4310MEInstallation Instructions
User Manual: LCN LCN 4310ME Installation Guide Installation Guide
Open the PDF directly: View PDF .
Page Count: 5
Download | |
Open PDF In Browser | View PDF |
*18762* 4310ME Series 18762 Door closer with electronic release & Multi-point hold open 1 Closer Installation 1a Closer Information 1d Closer is handed at the factory. The hand of the closer must match the hand of the door (see the door handing diagram below). 1b Before beginning this step, determine which type of wiring option will be used, and follow the corresponding instructions: ! Concealed Wiring: see Figure 3 on page 3. a. Prepare the frame per the proper template on page 4. Be sure all the holes are dimensioned correctly before drilling and tapping. b. Assemble the conduit connector provided to the flexible conduit, then attach to the hole in the mounting plate. c. Secure the mounting plate to the frame with the screws provided. ! warning ! Disconnect power before making any electrical connections or performing maintenance. Surface Wiring: see Figure 4 on page 3. LL NOTE: Remove the knockout in the top of the cover. a. Prepare the frame per the proper template on page 4. Be sure all the holes are dimensioned correctly before drilling and tapping. b. Secure the mounting plate to the frame with the screws provided. c. Attach the surface run Z\x” EMT conduit to the hole in the bracket on the mounting plate. Be sure the conduit is securely attached to the bracket. Spacer/Arm Place the spacer on the closer shaft, slide the arm onto the closer shaft, and secure it with the arm shaft screw (see Figure 1 on page 3). 1f Track Roller Insert the track roller into the track, and end caps into both ends of the track. Place track plugs in the track where needed. Using the fasteners provided, mount the track on the door per the template on page 4. 1g HAZARDOUS VOLTAGE CAN SHOCK AND CAUSE SEVERE INJURY Wiring Connections Make the wiring connections at this time. Connect the two black wires to the input voltage (polarity is not important). The green wire MUST be connected to an earth ground (see Figures 3 & 4 on page 3). 1e Voltage Voltage supplied to the door frame MUST match voltage of the solenoid. 1c Installation Instructions Set Screw Loosen the set screw in the end of the arm, open the door approximately 30˚, pull the arm over the top of the door and connect to the track roller. Tighten the set screw firmly. 1h Electric Checkout Regulate the closer and perform an electrical checkout, as instructed on page 2, before installing the closer cover. 1i Disengage the Swing Free Arm To disengage the swing-free action of the arm, insert the locking screw (stored in the tube portion of the arm) into the shaft end of the arm, and tighten securely. HOW TO TELL HAND OF DOOR: LEFT HAND DOOR RIGHT HAND DOOR = 33 ft-lbs 45 N-m 58 N MAXIMUM OPENING FORCE Customer Service 1-877-671-7011 www.allegion.com/us © Allegion 2014 Printed in U.S.A. 18762 Rev. 01/14-m 2 Regulation Instructions See Figure 2 on the opposite page for regulating screw location, door control diagram & spring power adjustment 2a Spring Power Adjustment DO NOT ALLOW THE DOOR TO SLAM INTO THE FRAME. The spring power should be adjusted only if more power is needed to close the door. Turning the spring adjustment B\cx” Allen Wrench clockwise will increase the spring power. Maximum adjustment is six (6) turns. 2b Regulation 4 Electrical Data for Door Holder Solenoid 24V AC-DC Nominal +10% - 15% @ 0.075 Amp. Max. 120V AC-DC Nominal +10% - 15% @ 0.030 Amp. Max. 24 V Hold Open Force Adjustment If the door is hard to pull out of the hold open position, adjust as shown. Important The closer leaves the factory set at a maximum holding force. The holding force may be decreased and increased again, but it cannot be increased beyond the original setting. A “normal” closing time from a 90° position is five (5) to seven (7) seconds, equally divided between the MAIN and LATCH SPEED. If adjustments are needed, use C\cx” Allen Wrench. To adjust the MAIN SPEED, turn the regulating screw clockwise to slow the door speed, or counterclockwise to increase the door speed. LATCH SPEED is adjusted the same way. When adjusting the BACKCHECK, turn the regulating screw clockwise to increase the amount of force, or counterclockwise to reduce the amount of force. DO NOT USE THE ABRUPT BACKCHECK SETTING OR EXPECT THE CLOSER TO ACT AS A STOP! Caution Improper installation or regulation may result in personal injury or property damage. Follow all instructions carefully. For questions, call LCN at 877-671-7011 3 Electrical Checkout After completion of installation & wiring, and with the unit properly powered, perform the following tests: 3a Hold Open With power on, open the door any position and release. The door should remain in the hold-open position within 10°. For a bypass model to hold open, the door must be opened beyond the degree of the door swing indicated on the label. 3b Door If the door does not remain in the hold open position, push the on/ off switch. Open the door again. If the shaft end of the arm still does not hold open, verify the proper voltage input at the solenoid leads. 3c Power Release Turn the power off. The shaft end of the arm should rotate and pick up the rest of the arm, closing the door completely. Push the on/off switch again to restore the power. 3d Put on Closer Cover After the electrical checkout is complete, fit the closer cover onto the closer and insert cover screws in proper locations. Hold the cover firmly against the mounting plate while tightening the cover screws securely. 3e Rechecking the System The system should be checked at regular intervals. It is recommended that steps 3a-3c be repeated every 90 days. + Turn counterclockwise to decrease the holding force Figure 1 Mounting Bracket For Surface Run Conduit Cover Hole For Concealed Conduit Connection End Cap Spring Power Adjustment Cover Screws Track Roller Spacer Arm Assy. Arm Shaft Screw Track Plug Figure 2 Backcheck 1 Main Speed 3 Latch Speed 6 Turns Max. To Increase Closing Power Figure 4 Figure 3 Connect Greenwire To Earth Ground Main Speed 2 Latch Speed Backcheck Arm Locking Screw Connect Black Wires to Input Voltage Leads (Polarity Not Important) Connect Black Wires to Input Voltage Leads (Polarity Not Important) Connect Greenwire To Earth Ground 4310 ME ® 4.25 17.00 Back Front Page 1 Page 2 Page 3 Page 4 11.000 BEGINNING SHEET folded SHEET Additional Notes: 1. None 11.000 Revision History L M 038791 043228 Material N P White Paper Notes 1. printed two sides 2. printed black 3. tolerance ± .13 4. printed in country may vary 5. drawings not to scale R S Revision Description: m > Revised artwork Edited By Approved By EC Number Release Date D. Myers M. Sasso 043228 01-01-14 Title 4310ME Series Instruction Sheet Creation Date 05-10-10 Created By N/A Software: InDesign CS6 Number Revision 18762 Activity 3899 Hancock Expwy Security, CO 80911 m © Allegion 2014
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2014:01:02 09:27:57-07:00 Metadata Date : 2014:01:02 09:28-07:00 Modify Date : 2014:01:02 09:28-07:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:fd3aed2a-5847-497d-a9fe-b8126f319ed2 Original Document ID : xmp.did:516915126ECCE1118A0D8AD340C27D6B Document ID : xmp.id:3EAFE3CFCA73E311B4D0E88C51DF512F Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:3DAFE3CFCA73E311B4D0E88C51DF512F Derived From Document ID : xmp.did:47A44EA0A139E21197309D1C525C39AC Derived From Original Document ID: xmp.did:516915126ECCE1118A0D8AD340C27D6B Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2014:01:02 09:27:57-07:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 5 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools