*19842* 19842 SEH Sentronic Electronic Door Holder PULL SIDE MOUNTED Installation Instructions PUSH SIDE MOUNTED Important Information The LCN SEH Sentronic is a door holder that must be installed in conjunction with a UL listed opposite-side mounted door closer or floor closer, which provides a minimum of 5 lb closing force measured 30” out on door from the hinge/pivot center line at the hold-open door position. The hold-open feature is adjustable in 3° increments from 80° to 100°. Floor or wall stops should be used. This instruction sheet and template apply to doors hung on butt hinges. Consult the factory if pivots or swing-clear hinges are to be used. Installation instructions 1. The voltage shown on the track cover plate must match the voltage supplied to the door frame (24V or 120V). If concealed wiring is desired, prepare the frame to the specifications per the template on page 3. If surface wiring, mount the track to the frame before running the EMT/conduit. For 24V wiring, see the enclosed Conduit Quick Connect instruction sheet. 2. Remove the end cap from the track. Insert the track slide and track roller, making sure that the stud is inserted into the hole in the track slide. Reinsert the end cap into the track. Isert the track plugs into the track. Using the fasteners provided, mount the track on the frame to the dimensions of the template on page 3. 3. Remove the cover plate and make all the necessary electrical connections. Replace the cover plate making sure the Test/Release button is through the hole. 4. Using the fastener provided, mount the rod & shoe part of the arm assembly to the door per the template on page 3. 5. Loosen the set screw in the end of the tube part of the arm assembly and connect to the track roller. Tighten the seet screw firmly. With the track roller at the leatch edge of the track, open the door part-way and insert the rod into the arm tube. 6. Slide the roller to the hinge edge of the track, into the hold-open position. Open the door to the desired degree of the hold-open and insert the arm adjusting screw, tightening firmly. 7. Turn the power on and perform the electrical checkout as follows: a. With power on, open the door completely. The door should remain in the open position. If the door does not stay open, check the electrical input. b. Push the release test switch. The door should close immediately. Open the door to the hold-open position and let it remain there. c. The system should be checked at frequent intervals. It is suggested that step b be repeated every 90 days. Pull Side Mounting SEH TRACK ASSEMBLY SEH TRACK ASSEMBLY TRACK PLUG TRACK (TOP) PLUG (TOP) END END PLUG PLUG ARM ADJUST. ARM SCREW ADJUST. SCREW COVER PLATE COVER TRACK ROLLER TRACK ROLLER ARM SET SCREW ARM SET PLATE SCREW SEH ARM ASSEMBLY SEH ARM ASSEMBLY Push Side Mounting TRACK SLIDE TRACK SLIDE TRACK PLUG (SIDE) TRACK PLUG (SIDE) TRACK ROLLER ARM TRACK SET ROLLER SCREW ARM SET SCREW SEH ARM ASSEMBLY SEH ARM ASSEMBLY ARM SHAFT SCREW ARM SHAFT SCREW SEH TRACK ASSEMBLY SEH TRACK ASSEMBLY Pull Side Template Right Hand shown, Left Hand opposite Right Hand shown, Left Hand opposite Right Hand shown, Left Hand opposite Push Side Template Right Hand shown, Left Hand opposite Right Hand shown, Left Hand opposite Right Hand shown, Left Hand opposite Right Hand shown, Left Hand opposite TERMINAL GROUND SOLENOID LEADS TERMINAL ASSEMBLY Right Hand shown, Left Hand opposite Hold Open Force Adjustment HOLD-OPEN FORCE RELEASE CONDUIT GROUND ADJUSTMENT SCREW TERMINAL SWITCH hold-open adjustment screwTEST in the diagram above. For SOLENOID TERMINALHOLE PLUG Locate the greater hold-open force, insert a C\cx Allen wrench (included in the screwpack) and turn clockwise. To LEADS decrease the amount of hold-open force, turn the screw counter-clockwise. Have a maximum of 4 ASSEMBLY TERMINAL GROUND turns. SOLENOID ASSEMBLY SOLENOID ASSEMBLY HOLD-OPEN FORCE ADJUSTMENT SCREW LEADS TERMINAL TERMINAL GROUND LEADS TERMINAL RELEASE TEST SWITCH Wiring Diagram - Polarity Not Important CONDUIT HOLE PLUG HOLD-OPEN FORCE RELEASE HOLD-OPEN FORCE RELEASE CONDUIT ADJUSTMENT SCREW SCREW CONDUIT TEST SWITCH ADJUSTMENT TEST SWITCHHOLE PLUG HOLE PLUG INPUT VOLTAGE: 24V AC/DC OR 120V AC/DC (usually from alarm panel or detector) warning TO EITHER TERMINAL OPTIONAL SWITCH TO EITHER TERMINAL Wiring Diagram - Polarity Not Important Wiring Diagram - Polarity Not Important Hazardous voltage can shock and cause severe injury! TO EITHER Wiring Diagram - Polarity Not Important INPUT VOLTAGE: TERMINAL Disconnect the power before making any electrical connections or performing maintenance. TO EITHER 24V AC/DC OR TERMINAL INPUT VOLTAGE: TO EITHER 120V AC/DC 24V AC/DC OR OPTIONAL SWITCH INPUT VOLTAGE: TERMINAL 120V AC/DC OPTIONAL SWITCH (usually from alarm 24V AC/DC OR (usually from alarm panel or detector) 120V AC/DC OPTIONAL SWITCH TO EITHER panel or detector) (usually from alarm TO EITHER © Allegion 2014 TERMINAL TERMINAL Printed in U.S.A. Customer Service panel or detector) TO EITHER 19842 Rev. 01/14-h TERMINAL 1-877-671-7011 www.allegion.com/us 17.00 Back Front Page 1 Page 3 Page 2 Blank Page 11.000 4.25 BEGINNING SHEET Front 11.000 folded SHEET Additional Notes: 1. None Revision History G H 037552 043228 Material J K White Paper Notes 1. printed two sides 2. printed black 3. tolerance ± .13 4. printed in country may vary 5. drawings not to scale L M Revision Description: h > Revised artwork Edited By Approved By EC Number Release Date D. Myers M. Sasso 043228 01-01-14 Title 4040SEH Series Instruction Sheet Creation Date N/A Created By N/A Software: InDesign CS6 Number Revision 19842 Activity 3899 Hancock Expwy Security, CO 80911 h © Allegion 2014
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2014:01:02 09:35:39-07:00 Metadata Date : 2014:01:02 09:35:41-07:00 Modify Date : 2014:01:02 09:35:41-07:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:a3d6df2d-127d-4233-b2af-08373cf04c46 Original Document ID : xmp.did:516915126ECCE1118A0D8AD340C27D6B Document ID : xmp.id:B49222E6CB73E311B4D0E88C51DF512F Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:B39222E6CB73E311B4D0E88C51DF512F Derived From Document ID : xmp.did:47A44EA0A139E21197309D1C525C39AC Derived From Original Document ID: xmp.did:516915126ECCE1118A0D8AD340C27D6B Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2014:01:02 09:35:39-07:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 4 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools