LDL Technology 16102 Telematics Control Unit User Manual C3131320010

LDL Technology Telematics Control Unit C3131320010

User Manual

Download: LDL Technology 16102 Telematics Control Unit User Manual C3131320010
Mirror Download [FCC.gov]LDL Technology 16102 Telematics Control Unit User Manual C3131320010
Document ID3440901
Application IDxqHe8Ec9cK/ZkvRnkowRWQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize464.76kB (5809471 bits)
Date Submitted2017-06-27 00:00:00
Date Available2017-12-24 00:00:00
Creation Date2017-05-31 14:47:41
Producing SoftwareLibreOffice 5.1
Document Lastmod0000-00-00 00:00:00
Document TitleC3131320010
Document CreatorWriter
Document Author: Thibault BENARD

Ref : C3140690010
Version : A1
Mounting procedure
TCU 1.2
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
Diffusion :
Internal
Status : Confidential
External
Limited
✘
Extended
✘
Mounting procedure
TCU 1.2
Reference : C3140690010
Version A1
Internal Approval
Name and
Department
Date
Author
Check
Approver
D. LUCE (MD)
T.MOREAU (SW-SY)
P. GABAUDAN (PM)
03/05/2017
16/05/2017
05/05/2017
Signature
COMPANY
NAME
DATE
SIGNATURE
LDL Technology SAS – Toulouse – France
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
1/ 13
Mounting procedure
TCU 1.2
Ref : C3140690010
Version : A1
MODIFCATION LIST:
Chapter / pages
Comments
Author
A0
Modification
date
22/12/2016
All
Creation
D.LUCE
A1
03/05/2017
§4 §5 §6 §7 & §9
New Bracket and warranty
conditions
D.LUCE
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
Version
LDL Technology SAS – Toulouse – France
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
2/ 13
Mounting procedure
TCU 1.2
Ref : C3140690010
Version : A1
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
Chapter :
1. PURPOSE..................................................................................................................................4
2. TCU 1.2 PRODUCT DESCRIPTION ......................................................................................... 4
2.1. Part Numbers.......................................................................................................................4
2.2. External Description.............................................................................................................4
3. MAIN FEATURES...................................................................................................................... 5
3.1. Electronic Features.............................................................................................................5
3.2. Mechanical Features........................................................................................................... 5
3.3. Connector Pin Out............................................................................................................... 5
4. TCU1.2 MOUNTING INTERFACE.............................................................................................6
5. TCU 1.2 MOUNTING RECOMMENDATIONS...........................................................................6
6. TCU 1.2 CONNECTION.............................................................................................................7
7. TCU 1.2 LOCATING RECOMMENDATIONS ............................................................................9
8. FCC/IC Regulatory notices.......................................................................................................10
8.1. Modification statement.......................................................................................................10
8.2. Interference statement.......................................................................................................11
8.3. Radiation Exposure Statement ..........................................................................................11
8.4. FCC Class B digital device notice..................................................................................... 12
9. APPENDIX................................................................................................................................13
LDL Technology SAS – Toulouse – France
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
3/ 13
Ref : C3140690010
Version : A1
Mounting procedure
TCU 1.2
1.
PURPOSE
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
This document is the Mounting procedure of the TCU 1.2.
TCU 1.2 is a part of a Tire Pressure Monitoring System.
The Telematics Control Unit (TCU) collects information on the vehicle and transmits it over the
GSM network to a back-end server. It can capture data from CAN, GPS, TPMS or other
wireless sensors.
2.
TCU 1.2 PRODUCT DESCRIPTION.
2.1.
PART NUMBERS
TCU 1.2 Part Number
Region
Model
TBD
Europe Middle East Africa (EMEA)
TBD
TBD
Europe Middle East Africa (EMEA)
TBD
TBD
Europe Middle East Africa (EMEA)
TBD
TBD
North America (NA)
TBD
TBD
North America (NA)
TBD
2.2.
EXTERNAL DESCRIPTION
Part
Material
Characteristics
all electronic parts
1 Housing
PP GF10
Black
1 Cover
PP GF10
Black
PBT GF20
Black and / or Grey
Stainless Steel C 1018
EPDM
Black
Stainless steel A2
NA (assembly)
Black
TCU
1 or 2 DT 06 connector
8 Screws
3 Silent-blocks
3 Spacers
1 Nitto Vent
LDL Technology SAS – Toulouse – France
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
4/ 13
Ref : C3140690010
Version : A1
Mounting procedure
TCU 1.2
3.
MAIN FEATURES
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
3.1.
ELECTRONIC FEATURES
Power supply (5A fuse protected)
7 to 32 VDC
Operating current
1A
Integrated Battery Power Supply (park mode)
3,65 VDC
Temperature operating range
-40°C to 85°C
Storage temperature range
0 to 30°C
Legal Regulations
R&TTE (99/5/EC)
FCC/IC
PTCRB
E marking
Antennas (GSM, GPS and RF)
Internal
3.2.
MECHANICAL FEATURES
3.3.
Total Mass
490 g
Dimensions (L x W x H)
160 x 180 x 75 mm
1 or 2 Connector(s) (8 Ways)
Deutsch DT06 serie
Tightness
IP 68 & IP69K
Mounting
LDL Brackets (see §4)
Wiring
LDL harnesses (see §6)
CONNECTOR PIN OUT
Gray Connector: WARNING / See Product Specification
Pin number
Function
Can Hi
Can Low
V Bat
Not connected or RX
Not connected or TX
GND
Not connected or internal Batt disable
Not connected
Black Connector:
Pin number
Mnemonic
Function
FG_IN1
Fuel gauge analogue input 1
FG_IN2
Fuel gauge analogue input 2
RM_CLK
Remote clock
RM_DAT
Remote data
LDL Technology SAS – Toulouse – France
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
5/ 13
Ref : C3140690010
Version : A1
Mounting procedure
TCU 1.2
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
Pin number
4.
Mnemonic
Function
RS_RX2
Serial reception 2
RS_TX2
Serial transmission 2
FG_GND
Fuel gauge ground
FG_PWR
Fuel gauge power supply
TCU1.2 MOUNTING INTERFACE
The TCU 1.2 is mounted on a plane surface fixed on the vehicle frame. The TCU 1.2 has 3
mounting points equipped with silent blocks. The TCU 1.2 must be fixed on a support (available
on demand). This support (“TCU 1.2 interface”, also called “Bracket base”) is defined in the
appendix.
5.
TCU 1.2 MOUNTING RECOMMENDATIONS
Screws (not provided by LDL) must be tightened @ 4,5 Nm +/-0,5 Nm. It's recommended to use
an elastic washer (Belleville type) between screw head and silent block with spacer. Stainless
steel is recommended.
M6 bolts are recommended, the screw for a fixation on a base plate fixation in thickness 1,5mm
must have a length equal or higher than 20mm.
NOTA BENE : The usage of a different bracket; without LDL written
approval; would void the warranty of the TCU 1.2.
LDL Technology SAS – Toulouse – France
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
6/ 13
Mounting procedure
TCU 1.2
Ref : C3140690010
Version : A1
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
Universal fixation kit can be provided by LDL. It consists of a bracket base and a bracket
extension. A combination of these parts is able to fit all vehicle types.
TCU 1.2 onto support
OK
NOk on
this side
LDL TCU 1.2 bracket combinations
LDL Technology SAS – Toulouse – France
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
7/ 13
Mounting procedure
TCU 1.2
Ref : C3140690010
Version : A1
To link a bracket base to a bracket extension, 2 bolts are needed, type M6, length 16mm, with 2
M6 washers (1 standard type and 1 Belleville type).
6.
TCU 1.2 CONNECTION
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
After its connection onto TCU 1.2, cable must be fastened as close as possible of its TCU 1.2
starting point (end of connector base).
This cable fastening must be done on a hole of the bracket base to minimize the effect of
vibration onto the connector assembly, see picture below:
Fastening
point
From the TCU 1.2 connector base to the fixation point on the bracket base, the cable curvature
diameter must be higher than 100 mm.
Verify that no tension stress is applied onto the harness between TCU 1.2 and the fixation
point onto the vehicle chassis, this check must be done after connection of the harness
connector onto the TCU 1.2 connector and after the fastening of the cable onto the bracket
base. Always avoid contact between cable and shape edge of the bracket.
The connector must be secured , means 2 harpoon shapes, each side of connector, must be
locked.
Nota Bene : Incorrect wiring should prevent the system to operate properly.
TCU 1.2 has to be connected to +12V or +24V through 5A fuse protection.
To power supply the TCU 1.2, it has to be connected on KL31 (battery negative) and KL15
(ignition).
LDL Technology SAS – Toulouse – France
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
8/ 13
Mounting procedure
TCU 1.2
Ref : C3140690010
Version : A1
When TCU 1.2 and ECU or EBS are connected to a same CAN network, they must share the
same ground.
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
LDL Technology can provide the wiring harness ; see table below : Table is not exhaustive ,ask
to LDL for details
TCU 1.2 connected to LDL harness are IP69K & IP 68.
7.
TCU 1.2 LOCATING RECOMMENDATIONS
The TCU 1.2 must be fixed horizontally and upside down (Vent side facing the ground):
The TCU 1.2 must be free from any metallic shield in the Z direction.
The antenna should be cleared as possible to optimize RF communication and reduce areas of
non-receipt.
There must be a free area of minimum 5cm wide around the TCU in all directions.
TCU 1.2 must not be exposed to direct gritting.
LDL Technology SAS – Toulouse – France
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
9/ 13
Ref : C3140690010
Version : A1
Mounting procedure
TCU 1.2
Each TCU 1.2 must be at a central point between the wheels that it has to receive, and aligned
on the vehicle axis. Distance between TCU 1.2 and WUS would not exceed 3 meters.
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
When trailer is equipped with an EBS, TCU 1.2 bracket should be fixed to EBS bracket.
TCU 12
TCU 12
Vehicle
axis
Truck TCU 12
Trailer TCU 12
MANDATORY TCU 1.2 location:
LDL Technology SAS – Toulouse – France 10/ 13
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
CONFIDENTIAL INFORMATION
Ref : C3140690010
Version : A1
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
Mounting procedure
TCU 1.2
8.
FCC/IC REGULATORY NOTICES
8.1.
MODIFICATION STATEMENT
LDL Technology do not approve any changes or modifications to this device by the user. Any
changes or modifications could void the user’s authority to operate the equipment.
LDL Technology n’approuve aucune modification apportée à l’appareil par l’utilisateur, quelle
qu’en soit la nature. Tout changement ou modification peut annuler le droit d’utilisation de
l’appareil par l’utilisateur.
8.2.
INTERFERENCE STATEMENT
This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
LDL Technology SAS – Toulouse – France 11/ 13
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
Mounting procedure
TCU 1.2
Ref : C3140690010
Version : A1
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
8.3.
RADIATION EXPOSURE STATEMENT
This device complies with FCC/IC radiation exposure limits set forth for an uncontrolled
environment and meets the FCC radio frequency (RF) Exposure Guidelines and RSS ‐102 of
the IC radio frequency (RF) Exposure rules. The antenna should be installed and operated with
minimum distance of 20 cm between the radiator and your body. This transmitter must not be
co-located or operating in conjunction with any other antenna or transmitter.
Le présent appareil est conforme à l'exposition aux radiations FCC / IC définies pour un
environnement non contrôlé et répond aux directives d'exposition de la fréquence de la FCC
radiofréquence (RF) et RSS‐102 de la fréquence radio (RF) IC règles d'exposition. L'antenne
doit être installée de façon à garder une distance minimale de 20 centimètres entre la source
de rayonnements et votre corps. L'émetteur ne doit pas être colocalisé ni fonctionner
conjointement avec une autre antenne ou un autre émetteur.
LDL Technology SAS – Toulouse – France 12/ 13
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt
Mounting procedure
TCU 1.2
9.
Ref : C3140690010
Version : A1
APPENDIX
CONFIDENTIAL INFORMATION
This document is the exclusive property of LDL Technology.
No content may be transmitted or reproduced in any form without written permission.
TCU 1.2 interface dimension, see drawing below ref. 2160620000 C0
LDL Technology SAS – Toulouse – France 13/ 13
Copyrights 2016
C3140690010-A1-TCU12_Mounting_Specification.odt

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 13
Language                        : fr-FR
Has XFA                         : No
Title                           : C3131320010
Author                          : Thibault BENARD
Subject                         : TCU Mounting Specification
Creator                         : Writer
Producer                        : LibreOffice 5.1
Create Date                     : 2017:05:31 14:47:41+02:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: T4516102

Navigation menu