LDL Technology 16102 Telematics Control Unit User Manual C3131320010
LDL Technology Telematics Control Unit C3131320010
User Manual
Ref : C3140690010 Version : A1 Mounting procedure TCU 1.2 CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. Diffusion : Internal Status : Confidential External Limited ✘ Extended ✘ Mounting procedure TCU 1.2 Reference : C3140690010 Version A1 Internal Approval Name and Department Date Author Check Approver D. LUCE (MD) T.MOREAU (SW-SY) P. GABAUDAN (PM) 03/05/2017 16/05/2017 05/05/2017 Signature COMPANY NAME DATE SIGNATURE LDL Technology SAS – Toulouse – France Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt 1/ 13 Mounting procedure TCU 1.2 Ref : C3140690010 Version : A1 MODIFCATION LIST: Chapter / pages Comments Author A0 Modification date 22/12/2016 All Creation D.LUCE A1 03/05/2017 §4 §5 §6 §7 & §9 New Bracket and warranty conditions D.LUCE CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. Version LDL Technology SAS – Toulouse – France Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt 2/ 13 Mounting procedure TCU 1.2 Ref : C3140690010 Version : A1 CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. Chapter : 1. PURPOSE..................................................................................................................................4 2. TCU 1.2 PRODUCT DESCRIPTION ......................................................................................... 4 2.1. Part Numbers.......................................................................................................................4 2.2. External Description.............................................................................................................4 3. MAIN FEATURES...................................................................................................................... 5 3.1. Electronic Features.............................................................................................................5 3.2. Mechanical Features........................................................................................................... 5 3.3. Connector Pin Out............................................................................................................... 5 4. TCU1.2 MOUNTING INTERFACE.............................................................................................6 5. TCU 1.2 MOUNTING RECOMMENDATIONS...........................................................................6 6. TCU 1.2 CONNECTION.............................................................................................................7 7. TCU 1.2 LOCATING RECOMMENDATIONS ............................................................................9 8. FCC/IC Regulatory notices.......................................................................................................10 8.1. Modification statement.......................................................................................................10 8.2. Interference statement.......................................................................................................11 8.3. Radiation Exposure Statement ..........................................................................................11 8.4. FCC Class B digital device notice..................................................................................... 12 9. APPENDIX................................................................................................................................13 LDL Technology SAS – Toulouse – France Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt 3/ 13 Ref : C3140690010 Version : A1 Mounting procedure TCU 1.2 1. PURPOSE CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. This document is the Mounting procedure of the TCU 1.2. TCU 1.2 is a part of a Tire Pressure Monitoring System. The Telematics Control Unit (TCU) collects information on the vehicle and transmits it over the GSM network to a back-end server. It can capture data from CAN, GPS, TPMS or other wireless sensors. 2. TCU 1.2 PRODUCT DESCRIPTION. 2.1. PART NUMBERS TCU 1.2 Part Number Region Model TBD Europe Middle East Africa (EMEA) TBD TBD Europe Middle East Africa (EMEA) TBD TBD Europe Middle East Africa (EMEA) TBD TBD North America (NA) TBD TBD North America (NA) TBD 2.2. EXTERNAL DESCRIPTION Part Material Characteristics all electronic parts 1 Housing PP GF10 Black 1 Cover PP GF10 Black PBT GF20 Black and / or Grey Stainless Steel C 1018 EPDM Black Stainless steel A2 NA (assembly) Black TCU 1 or 2 DT 06 connector 8 Screws 3 Silent-blocks 3 Spacers 1 Nitto Vent LDL Technology SAS – Toulouse – France Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt 4/ 13 Ref : C3140690010 Version : A1 Mounting procedure TCU 1.2 3. MAIN FEATURES CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. 3.1. ELECTRONIC FEATURES Power supply (5A fuse protected) 7 to 32 VDC Operating current 1A Integrated Battery Power Supply (park mode) 3,65 VDC Temperature operating range -40°C to 85°C Storage temperature range 0 to 30°C Legal Regulations R&TTE (99/5/EC) FCC/IC PTCRB E marking Antennas (GSM, GPS and RF) Internal 3.2. MECHANICAL FEATURES 3.3. Total Mass 490 g Dimensions (L x W x H) 160 x 180 x 75 mm 1 or 2 Connector(s) (8 Ways) Deutsch DT06 serie Tightness IP 68 & IP69K Mounting LDL Brackets (see §4) Wiring LDL harnesses (see §6) CONNECTOR PIN OUT Gray Connector: WARNING / See Product Specification Pin number Function Can Hi Can Low V Bat Not connected or RX Not connected or TX GND Not connected or internal Batt disable Not connected Black Connector: Pin number Mnemonic Function FG_IN1 Fuel gauge analogue input 1 FG_IN2 Fuel gauge analogue input 2 RM_CLK Remote clock RM_DAT Remote data LDL Technology SAS – Toulouse – France Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt 5/ 13 Ref : C3140690010 Version : A1 Mounting procedure TCU 1.2 CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. Pin number 4. Mnemonic Function RS_RX2 Serial reception 2 RS_TX2 Serial transmission 2 FG_GND Fuel gauge ground FG_PWR Fuel gauge power supply TCU1.2 MOUNTING INTERFACE The TCU 1.2 is mounted on a plane surface fixed on the vehicle frame. The TCU 1.2 has 3 mounting points equipped with silent blocks. The TCU 1.2 must be fixed on a support (available on demand). This support (“TCU 1.2 interface”, also called “Bracket base”) is defined in the appendix. 5. TCU 1.2 MOUNTING RECOMMENDATIONS Screws (not provided by LDL) must be tightened @ 4,5 Nm +/-0,5 Nm. It's recommended to use an elastic washer (Belleville type) between screw head and silent block with spacer. Stainless steel is recommended. M6 bolts are recommended, the screw for a fixation on a base plate fixation in thickness 1,5mm must have a length equal or higher than 20mm. NOTA BENE : The usage of a different bracket; without LDL written approval; would void the warranty of the TCU 1.2. LDL Technology SAS – Toulouse – France Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt 6/ 13 Mounting procedure TCU 1.2 Ref : C3140690010 Version : A1 CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. Universal fixation kit can be provided by LDL. It consists of a bracket base and a bracket extension. A combination of these parts is able to fit all vehicle types. TCU 1.2 onto support OK NOk on this side LDL TCU 1.2 bracket combinations LDL Technology SAS – Toulouse – France Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt 7/ 13 Mounting procedure TCU 1.2 Ref : C3140690010 Version : A1 To link a bracket base to a bracket extension, 2 bolts are needed, type M6, length 16mm, with 2 M6 washers (1 standard type and 1 Belleville type). 6. TCU 1.2 CONNECTION CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. After its connection onto TCU 1.2, cable must be fastened as close as possible of its TCU 1.2 starting point (end of connector base). This cable fastening must be done on a hole of the bracket base to minimize the effect of vibration onto the connector assembly, see picture below: Fastening point From the TCU 1.2 connector base to the fixation point on the bracket base, the cable curvature diameter must be higher than 100 mm. Verify that no tension stress is applied onto the harness between TCU 1.2 and the fixation point onto the vehicle chassis, this check must be done after connection of the harness connector onto the TCU 1.2 connector and after the fastening of the cable onto the bracket base. Always avoid contact between cable and shape edge of the bracket. The connector must be secured , means 2 harpoon shapes, each side of connector, must be locked. Nota Bene : Incorrect wiring should prevent the system to operate properly. TCU 1.2 has to be connected to +12V or +24V through 5A fuse protection. To power supply the TCU 1.2, it has to be connected on KL31 (battery negative) and KL15 (ignition). LDL Technology SAS – Toulouse – France Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt 8/ 13 Mounting procedure TCU 1.2 Ref : C3140690010 Version : A1 When TCU 1.2 and ECU or EBS are connected to a same CAN network, they must share the same ground. CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. LDL Technology can provide the wiring harness ; see table below : Table is not exhaustive ,ask to LDL for details TCU 1.2 connected to LDL harness are IP69K & IP 68. 7. TCU 1.2 LOCATING RECOMMENDATIONS The TCU 1.2 must be fixed horizontally and upside down (Vent side facing the ground): The TCU 1.2 must be free from any metallic shield in the Z direction. The antenna should be cleared as possible to optimize RF communication and reduce areas of non-receipt. There must be a free area of minimum 5cm wide around the TCU in all directions. TCU 1.2 must not be exposed to direct gritting. LDL Technology SAS – Toulouse – France Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt 9/ 13 Ref : C3140690010 Version : A1 Mounting procedure TCU 1.2 Each TCU 1.2 must be at a central point between the wheels that it has to receive, and aligned on the vehicle axis. Distance between TCU 1.2 and WUS would not exceed 3 meters. CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. When trailer is equipped with an EBS, TCU 1.2 bracket should be fixed to EBS bracket. TCU 12 TCU 12 Vehicle axis Truck TCU 12 Trailer TCU 12 MANDATORY TCU 1.2 location: LDL Technology SAS – Toulouse – France 10/ 13 Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt CONFIDENTIAL INFORMATION Ref : C3140690010 Version : A1 This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. Mounting procedure TCU 1.2 8. FCC/IC REGULATORY NOTICES 8.1. MODIFICATION STATEMENT LDL Technology do not approve any changes or modifications to this device by the user. Any changes or modifications could void the user’s authority to operate the equipment. LDL Technology n’approuve aucune modification apportée à l’appareil par l’utilisateur, quelle qu’en soit la nature. Tout changement ou modification peut annuler le droit d’utilisation de l’appareil par l’utilisateur. 8.2. INTERFERENCE STATEMENT This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. LDL Technology SAS – Toulouse – France 11/ 13 Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt Mounting procedure TCU 1.2 Ref : C3140690010 Version : A1 Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. 8.3. RADIATION EXPOSURE STATEMENT This device complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines and RSS ‐102 of the IC radio frequency (RF) Exposure rules. The antenna should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Le présent appareil est conforme à l'exposition aux radiations FCC / IC définies pour un environnement non contrôlé et répond aux directives d'exposition de la fréquence de la FCC radiofréquence (RF) et RSS‐102 de la fréquence radio (RF) IC règles d'exposition. L'antenne doit être installée de façon à garder une distance minimale de 20 centimètres entre la source de rayonnements et votre corps. L'émetteur ne doit pas être colocalisé ni fonctionner conjointement avec une autre antenne ou un autre émetteur. LDL Technology SAS – Toulouse – France 12/ 13 Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt Mounting procedure TCU 1.2 9. Ref : C3140690010 Version : A1 APPENDIX CONFIDENTIAL INFORMATION This document is the exclusive property of LDL Technology. No content may be transmitted or reproduced in any form without written permission. TCU 1.2 interface dimension, see drawing below ref. 2160620000 C0 LDL Technology SAS – Toulouse – France 13/ 13 Copyrights 2016 C3140690010-A1-TCU12_Mounting_Specification.odt
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 13 Language : fr-FR Has XFA : No Title : C3131320010 Author : Thibault BENARD Subject : TCU Mounting Specification Creator : Writer Producer : LibreOffice 5.1 Create Date : 2017:05:31 14:47:41+02:00EXIF Metadata provided by EXIF.tools