LENNOX Air Conditioner/heat Pump(outside Unit) Manual L0805471
User Manual: LENNOX LENNOX Air conditioner/heat pump(outside unit) Manual LENNOX Air conditioner/heat pump(outside unit) Owner's Manual, LENNOX Air conditioner/heat pump(outside unit) installation guides
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
LENNOX COOLING Fj_ppuTeCh n ical blications KITS AND ACCESSORIES Lithe U.S.A. 1,_2003 Lennox Industries tnc, Dallas, Texas, USA 504,724M 04/03 Supersedes CONDENSER COIL REPLACEMENT KIT 503,399M INSTALLATION INSTRUCTIONS FOR REPLACEMENT CONDENSER COIL FOR HS29 AND 10ACB SERIES UNITS Package 1 of 1 contains: 1 - Condenser coil 1 - Discharge line Check the replacement coil for shipping damage. If you find any damage, immediately contact the last carrier. 8 -Replace top cap and control box. Restore power. 9-Refer to the unit installation instructions for leak testing, evacuation and start-up procedures. Charge the unit as outlined in the installation instructions or charging sticker. NOTE - Cut and debut the discharge manifold as needed. HS29-211 and 10ACB18 Use this kit for HS29-1, -2 and 10ACB-1, -2, -3, -4, -5, and -6 series units. The kit is a direct replacement for HS29-2 and 10ACB-3, -4, -5, and -6 units. The enclosed plumbing parts are not needed. To apply the kit to HS29-1 and 10 ACB-1 and -2 units, use the provided parts to slightly modify the plumbing. 1 -Disconnect the power from the unit. 2 -Reclaim the refrigerant from the unit. 3 -Remove top cap and control box from the unit. 4 -HS29-1 and 10ACB-1, -2 Units - Sweat off the liquid line from the service valve. Protect the valve with a wet rag. Sweat off the discharge line from the compressor at the discharge elbow. Discard the removed plumbing parts. HS29-2 and 10ACB-3, -4, -5, and -6 Units - Sweat off the liquid line from the service valve. Protect the valve with a wet rag, Sweat off discharge line at manifold section of coil, Discard the removed plumbing parts. coil assembly with manifold discharge line liquid line Figure H829-261 1 and 10ACB24 5 -Remove the condenser coil assembly from the unit, 6 -Install the replacement coil assembly. 7 -HS29-1 and 10ACB-1, -2 Units - Sweat in liquid line from new coil to new liquid line service valve, Protect valve with a wet rag. Sweat in the provided discharge line from the manifold section of the coil to discharge elbow at the compressor Specific plumbing configuration should resemble examples given in figures 1 through 6, HS29-2 and 10ACB-3, -4, -5, and -6 Units - Sweat in the liquid line from the new coil to the service valve. Protect the valve with a wet rag. Sweat in the discharge line back to manifold section of the new coil. Specific plumbing configuration should resemble examples given in figures 1 through 6. Provided plumbing parts are not necessary in -2 applications. However, they may be used if preferred. 04/03 coil assembly with manifold IIIHI£1111111111111111111 Page1 discharge line liquid line Figure 2 504,724M IIIIIIIIIIIIllllllllllllllllllllllllll HS29-311 coil assembly with manifold and 10ACB30 and 10ACB42/48 coil assembly liquid line Figure H29-410 coil assembly with manifold HS29-460/510 with manifold discharge line 3 Figure and 10ACB36 liquid line HS29-650 discharge liquid line 5 and 10ACB60 Y line with manifold Figure 4 liquid line Figure Page 2 discharge 6 line
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 2 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Mon Jun 30 04:24:58 2008 Author : Title : Subject :EXIF Metadata provided by EXIF.tools