LENNDX ,1,_2000 Lennox Industries Inc.Dallas, Texas, USAINSTALLATIONINSTRUCTIONSHS40 S UNITSTechnicalCONDENSING UNITS lIE_ :.)504,186M .LU_ Publications11/2002 Lithe U.S.A.Supersedes 4/2000HS40 condensing units use R407C which is an ozonefriendly HFC refrigerant. This unit must be installed with amatching indoor coil and line set as outlined in the LennoxEngineering Handbook. HS40 condensing units are de-signed for use in expansion valve systems only. They arenot designed to be used in RFC systems. An expansionvalve and filter drier approved for use with R407C havebeen shipped with the unit. These components must beinstalled prior to unit operation.A, WARNINGWARNINGHS40 Condensing Unit ......................... 1Shipping & Packing List ........................ 1Unit Dimensions ............................... 2General Information ............................ 3Setting the Unit ................................ 3Electrical ..................................... 3Plumbing ..................................... 4Flushing Existing Line Set and Indoor Coil ........ 4Liquid & Suction Line Service Valves ............. 6Leak Testing .................................. 7Evacuation & Dehydration ...................... 7Start-Up ...................................... 8Charging ..................................... 8System Operation ............................. 10Maintenance .................................. 10Start-Up & Performance Check List .............. 11RETAIN THESE INSTRUCTIONSFOR FUTURE REFERENCE1 - Assembled HS40 condensing unit1 - Bag assembly:1 - Sight glass1 - 5/16-3/8 inch adapter1 - 45° elbow1 - Expansion valve (approved for use with R407C)1 - Drier (approved for use with R407C systems)Check equipment for shipping damage. If you find anydamage, immediately contact the last carrier.A, WARNING11/02IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIll Page 1504,186MIIlIIIIIIIIIIIIIIIIIIIIIIIHIIIIIIIIIIIII
INLET©AIRINLET _AIRINLET©AIRINLET'_AIRTOP VIEWh._l=_ C ,vSIDE VIEW (19)(111)OPTIONAL UNITSTAND-OFF KIT (4)_ "(Field Installed)COIL DRAIN OUTLETS_""_I(Around perimeter of base)/SUCTION LINECONNECTION (162)LIQUID LINECONNECTIONELECTRICALINLETSTOP VIEW BASE SECTIONOUTDOORCOIL FANCOMPRESSORSUCTION &LIQUID LINECONNECTIONOPTIONAL UNITSTAND-OFF KIT (4)_(Field Installed) /(70)SIDE VIEWModel No, A B CHS40-018HS40-024 mm 635 616 616HS40-036HS40-048 mm 838 819 616HS40-065 mm 946 927 718Page 2

Navigation menu