INSTALLATION
LOSS OF CHARGE
INSTRUCTIONS
FOR LOSS OF CHARGE KIT (LB-110135
USED WITH CONDENSING
UNITS AND HEAT PUMPS
KIT
/ 84M23)
Package 1 of 1 contains:
1 - Loss of charge switch ($24)
2 - Wire nuts
NOTE - The depressor tee fitting provided with this kit is
used to install the loss of charge switch on the liquid line
service valve.
1 - Valve depressor tee fitting
The loss of charge kit (LB-110135A/84M23)
is used with
all condensing units and heat pumps which use either
R-22 or R-410A refrigerant. The loss of charge switch
protects the system compressor from damage due to a
loss of charge, The single-pole / single-throw, normally
closed switch is permanently adjusted to open at 25 psig
(+5 psig), The switch automatically resets (closes) at 55
psig (+5 psig),
WARNING
1 - Disconnect power to unit,
2 - Install the provided loss of charge switch on an open
port (no valve core) of the provided valve depressor
tee fitting,
NOTE - The pressure switch must be installed
before the depressor tee fitting is installed in
order to avoid refrigerant loss.
3- Install the depressor tee fitting on the liquid line
service port, See figure 1 for illustration of typical
installation,
4 - Check for leaks,
5-Wire
loss of charge switch in series with the
compressor contactor coil. Refer to wiring diagram on
unit and to field wiring diagrams in figures 2 and 3,
6 - Turn on power to unit,
TYPICAL INSTALLATION LOSS OF CHARGE SWITCH
TOP VIEW
_-=_LIQU
t
ID LINE
!
SERVICE VALVE
:_
I
/
LOSS OF CHARGE
SWITCH
CAUTION "compressorAV°id
shorting controINEwtoSERViCE
_
PORT
VALVE DEPRESSOR
TEE FITTING
CAUTION - Loss of charge switch
must be installed on open side of
tee first to prevent refrigerant loss.
FIGURE 1
04/05
IIIBIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
505,002M
Page 1
IIIBIIIIIIIIIIIIIIIIIIIIIIIIIIB
LOSS OF CHARGE SWITCH WIRING
FOR AIR CONDITIONING UNITS
LOSS OF CHARGE SWITCH WIRING
FOR HEAT PUMP UNITS
9
f
RGE
G
FROM
_]
S24
THERMOSTAT
_
LOS%_/vFTCFH
ARGE
\
PRESSURE
SWITCH
(IF USED)
T H E_R_MOoMs
TAT
H, H
,,_
.,_
_1
*NOTE - If DL15 (compressor
OI
I
will be wired between the loss of charge switch
(S24) and the compressor contactor, Please refer
delay ) is used, it
{_
to wiring diagram located on the unit.
*NOTE-If DL15 (compressor delay ) is used, it will
be wired between the loss of charge switch ($24)
and the high pressure switch ($4), Please refer
to wiring diagram located on the unit.
K1
_LcoMP#SSOR
k
..COMPRESSOR
CONTACTOR
kJ
_
= TO COMMON
FIGURE 2
CONTACTOR
= TO COMMON
FIGURE 3
Page 2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 2 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Mon Jun 30 04:54:53 2008 Author : Title : Subject :EXIF Metadata provided by EXIF.tools