LENNOX Package Units(both Units Combined) Manual L0806659
User Manual: LENNOX LENNOX Package Units(both units combined) Manual LENNOX Package Units(both units combined) Owner's Manual, LENNOX Package Units(both units combined) installation guides
Open the PDF directly: View PDF .
Page Count: 28
Download | |
Open PDF In Browser | View PDF |
INSTALLATION INSTRUCTIONS TeCh n i cal blications Litho U.S.A. ,_,_2007 THA024 _,WARNING (2 TON) (2-1/2 TON) (3 TON) THA030 THA036 THA048 (4 TON) THA060 (5 TON) THA072 (6 TON) RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Dimensions ................................. Shipping and Packing List .................... Page 1 Page 2 General Page 2 .................................... Requirements ............................... Unit Support ................................ Page 2 Page 3 Duct Connection ............................ Rigging Unit For Lifting ....................... Page 3 Page 3 Condensate Drains .......................... Electrical Connections ....................... Page 4 Page 6 FILTERS 024,030, 036, 048, 060B: 16 X 20 X2" 060S, 072S: 20 X 20 X 2" INDOOR INDOOR COIL BLOWER MOTOR HEAT PUMP PACKAGED 505,308M 6/2007 Supersedes 505,098M Blower UNITS Operation and Adjustments Heating Start-Up ............................ Page 23 Cooling Start-Up ............................ Page 23 Defrost Control Service Board ............ Page 9 ........................ Page 26 .................................... DEFROST CONTROL BOARD (CMC1) Page 26 OUTDOORFAN TXV OUTDOOR TXV ECONOMIZER (OPTIONAL) CONDENSATE DRAIN ELECTRIC HEAT (OPTIONAL) 06/07 IIIBIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII OUTDOOR COIL REVERSING VALVE TB1 LOW VOLTAGE TERMINAL BLOCK COMPRESSOR 505,308M IIIlllIIIIIIIIIIIIIIIIIHIIIIIIl 45/ .11..1 1/.T18 '_ BOTTOM 47 / Base// I I I I S&q_LY-+ _ I I _1-- BOTTOM I 26-1/2 _ !r \\\_N_z::_j//// CENTER_T_+ _ 53/4 -_ _ _1- BOTTOM CONDENSATE OUTLET _ 38"112"-I_" BOTTOM POWER (3 x 8) ENTRY TOP VIEW (Base) 83-1/4 45 q ELECTRICAL 04 I o_ o o__ o_ i _1- CONDEN- i .. o .. '- _ SATE OUTLET _ _ oo _ _ 5_ oo1_ (Either Side) I,oo _//_ _-- 47 Base LIFTING HOLES (For rigging) " E 261/2 ool _, 5-1/2 _1_" 85-1/4 Base I111 I SIDE VIEW END VIEW III F llII qzz_ OO J FORKLIFT SLOTS (Front, Back and Blower End) // / HORIZONTAL SUPPLY AIR OPENING Page 1 CCCC] 5-!/2 / o I _/2 HORIZONTAL RETURN AIR OPENING P The National Electric Code (ANSI/NFPA No. 70-1984) is available from: Package 1 of 1 contains: National Fire Protection Association 1 - Assembled unit 1 Batterymarch Park PO Box 9101 Check unit for shipping damage. Receiving party should contact last carrier immediately if shipping damage is found, These instructions are intended as a general guide and do not supersede local codes in any way. Authorities having jurisdiction should be consulted before installation, Availability of units and options varies by brand, The THA unit is ETL/CSA certified as a heat pump with cooling and with or without auxiliary electric heat for non-residential use only at the clearances to combustible materials as listed on the unit nameplate and in figure 1. Quincy, MA 02269-9101 Installation of ETL/CSA certified units must also conform with current standard C273.5 "Installation Requirements for Heat Pumps" and applicable local codes. Authorities having jurisdiction should be consulted before installation. Use of this unit as a construction heater or air conditioner is not recommended during any phase of construction. Very low return air temperatures, harmful vapors and operation of the unit with clogged or misplaced filters will damage the unit. If this unit has been used for heating or cooling of buildings or structures under construction, the following conditions must be met or the warranty will be void: Installation of THA heat pumps must conform with standards in National Fire Protection Association (NFPA) "Standard for Installation of Air Conditioning and Ventilating Systems NFPA No. 90A," "Standard for Installation of Residence Type Warm Air Heating and Air conditioning Systems NFPA No. 90B," local municipal building codes and manufacturer's installation instructions. • A room thermostat must control the unit. The use of fixed jumpers that will provide continuous heating or cooling is not allowed. • A pre-filter must be installed at the entry to the return air duct. • The return air duct must be provided and sealed to the unit. • Return air temperature range between 55°F (13°C) and 80°F (27°C) must be maintained. JNIT CLEARANCES t • Air filters must be replaced and pre-filter must be removed upon construction completion. C • The unit components, duct system, air filters and evaporator coil must be thoroughly cleaned following final construction clean-up. • The unit operating conditions (including airflow, cooling operation, and heating operation) must be verified according to these installation instructions. t A ,WARNING FIGURE 1 Clearance 1 Unit A in. (mm) B in. (mm) C in. (mm) D in. (mm) Top Clearance Service Clearance 48 (1219) 36 (914) 36 (914) 36 (914) Unobstructed Minimum Operation Clearance 36 (914) 36 (914) 36 (914) 36 (914) Unobstructed Note - Entire perimeter mounting 1 Service Minimum of unit base requires support when elevated ACAUTION above surface. Clearance Operation - Required Clearance for removal of serviceable - Required clearance parts. for proper unit operation. Page 2 2- Specified installation clearances must be maintained when installing units, Refer to figure 1. 3- Top of support slab should be at least 4" (102mm) above the finished grade and located so no run-off water from higher ground can collect around the unit, 4- Units require support along all four sides of unit base. Supports must be constructed of steel or suitably treated wood materials, klMPORTANT NOTE - Securely fasten roof frame A - Downflow Discharge to roof per local codes. Application Roof Mounting with T1CURB 1- The T1CURB roof mounting frame must be installed, flashed and sealed in accordance with the All exterior ducts, joints, and openings in roof or building walls must be insulated and weatherproofed with flashing and sealing compounds in accordance with applicable codes. Any duct passing through an unconditioned space must be insulated. instructions provided with the frame, CAUTION 2- The TlCURB roof mounting frame should be square and level to 1/16" per linear foot (5mm per linear meter) in any direction, 3- Duct must be attached to the roof mounting frame and not to the unit; supply and return plenums must be installed before setting the unit, Installer's Roof Mounting Frame Many types of roof frames can be used to install the unit, depending upon different roof structures. Items to keep in mind when using the building frame or supports are: 1- The unit base is fully enclosed and insulated, so an enclosed frame is not required. 2- The frames or supports must be constructed with non-combustible materials and should be square and level to 1/16" per linear foot (5mm per linear meter) in any direction, 3- Frame or supports must be high enough to prevent any form of moisture from entering unit. Recommended minimum frame height is 14" (356mm), 4- Duct must be attached to the roof mounting frame and not to the unit. Supply and return plenums must be installed before setting the unit, 5- Units require support along all four sides d unit base. Supports must be constructed of steel or suitably treated wood materials, 1- Detach wooden base protection before rigging, 2- Remove all six base protection brackets before setting unit, A 12" or longer extension is recommended when using a drill gun. 3- Connect rigging to the unit base using both holes in each corner. See figure 2, 4- All panels must be in place for rigging. 5- Place field-provided H-style pick in place just above top edge d unit. Frame must be of adequate strength and length. (H-style pick prevents damage to unit, TH UNIT *Maximum weight with all available installed accessories. CAUTION: DO NOT WALK ON UNIT. NOTE-When installing unit on a combustible surface for downflow discharge applications, the TlCURB roof mounting frame is required, B - Horizontal 1- Discharge Applications Units which are equipped with an optional economizer and installed in horizontal airflow applications must use a horizontal conversion kit, Page 3 FIGURE 2 Lifting Point Should Be Directly Above Center Of Gravity. HORIZONTAL RETURN AIR DUCTWORK WITH OPTIONAL ECONOMIZER Unit is shipped with panels covering the horizontal supply and return air openings. Remove horizontal covers and place over downflow openings for horizontal air discharge, See figure 3, Secure in place with sheet metal screws, UNIT UNIT SUPPLY AND RETURN AIR OPENINGS HORIZONTAL RETURN AIR HORIZONTAL SUPPLY AIR OPENING OPENING __ HORIZONTAL RETURN AIR DUCT INSTALL BAROMETRIC RELIEF DAMPERS AND HOOD IN RETURN AIR DUCT FIGURE 4 DOWNFLOW RETURN AIR OPENING DOWNFLOW SUPPLY AIR OPENING FIGURE 3 Make drain connection to the 3/4" N,P,T, drain coupling provided on unit, Units Equipped With An Optional Economizer 1- Remove the horizontal supply air cover and position over the downflow supply air opening, Secure with sheet metal screws, 2- Leave the horizontal return air cover in place. 3- Locate the separately ordered horizontal air discharge kit, Place the kit panel over the downflow return air opening, 4- Remove and retain the barometric relief dampers and lower hood. 5- Install return air duct beneath outdoor air intake, See figure 4. Install barometric relief damper in lower hood and install in duct as shown in figure 4. Note - The drain pan is made with a glass reinforced engineered plastic capable of withstanding typical joint torque but can be damaged with excessive force, Tighten pipe nipple hand tight and turn an additional quarter turn, A trap must be installed between drain connection and an open vent for proper condensate removal, See figure 5 or 6, It is sometimes acceptable to drain condensate onto the roof or grade; however, a tee should be fitted to the trap to direct condensate downward. The condensate line must be vented. Check local codes concerning condensate disposal. Refer to pages 1 and 2 for condensate drain location, Page 4 CONDENSATE SIDEDRAIN CAULK AROUND CONDENSATE CONNECTION COUPLING. 1Mi;i5mmU2) ;eitth0 ' dX_ (3re) of line I I OPENViNT \ UN,T _ CONDENSATE MULLION II IIII FIGURE 7 If the unit has hinged panels, two hinge screws must be removed in addition to the mullion screws. See figure 8. MOUNTING UNITS WITH HINGED PANELS FRAME "_'P'_ FIGURE 5 CONDENSATE BOTTOM DRAIN CONNECTION UNIT C°NDENSATE REMOVE TWO SCREWS E] CAULK AROUND CONDENSATE DRAIN MULLION E,:I COUPLING FIGURE 8 _ MOUNTING FRAME OPiN VENT Lift the front edge of the drain pan and slide pan out of unit, See figure 9. REMOVE DRAIN PAN Minimum Pitch 1" (25 ram) per 10' (3 m) of line FIGURE 6 Units are shipped with the drain coupling facing the front of the unit, Condensate can be drained from the back or bottom of the unit with the following modifications. The unit can be installed in either downflow or horizontal air discharge regardless of condensate drain location. DRAIN PAN Rear Drain Connection 1- Remove the condensate drain mullion, See figure 7. Remove the two panels on each side of the mullion. Page 5 FIGURE 9 _ Make sure the cap over the unit bottom drain hole is secure. 5- Remove the cap over the unit bottom drain hole, 6- Slide the drain pan back into the unit. 4- Rotate the drain pan until the downward slope is toward the back of the unit. Slide the drain pan back into the unit. Be careful not to dislodge the cap over the bottom drain hole. 7- From the back side of the unit, pull the drain pan coupling through the rear condensate opening, 8- From the front side of the unit, move the drain pan until the bottom coupling settles into the unit bottom drain opening. Once in place, check to make sure the coupling is still positioned through the rear condensate drain hole. 5- From the back side of the unit, pull the drain pan coupling through the rear condensate opening. 6- Replace the condensate drain mullion. Bottom Drain Connection 1- Remove the condensate drain mullion. See figure 7. 2- Lift the front edge of the drain pan and slide pan out of unit. See figure 9. 3- Turn the drain pan upside down and drill a pilot hole through the bottom of the drain pan in the center of the coupling. See figure 10. BOTTOM CONDENSATE CAUTION: Be careful not to damage the coupling threads when drilling the hole. Use a field-provided connection. g- 3/4" plug to seal side drain 10- Replace the condensate drain mullion. POWER SUPPLY Do not apply power or close disconnect DRAIN switch until installation is complete. Refer to start-up directions. Refer closely to unit wiring diagram. Figure 12 shows a typical DRILL A PILOT HOLE IN CENTER OF COUPLING unit wiring diagram. Refer to unit nameplate for minimum circuit ampacity and maximum fuse size. - Units are factory-wired for 240,460,575 volt supply. For 208V supply, remove the insulated terminal cover from the 208V terminal on the control transformer. Move the wire from the transformer 240V terminal to the 208V terminal. Place the insulated terminal cover on the unused 240V terminal. After drilling the pilot hole, drill a 7/8" hole from the inside of the pan. - FIGURE 10 . From the inside of the pan, use a Vari-BiP bit to enlarge the hole to 7/8". Do not damage coupling threads. Page 6 Route power through the bottom power entry area and connect to L1, L2, and L3 on the top of K1 in control area above compressor. Route power to TB2 on units equipped with electric heat. Secure power wiring with factory-installed wire ties provided in control box. See unit wiring diagram. CONTROL WIRING A - Thermostat 3- Connect thermostat wiring to TB1 terminal control board on the lower side of the controls hat section, Location Wire as shown in figure 11 for electro-mechanical and electronic thermostats, If using other Room thermostat mounts vertically on a standard 2" X 4" handy box or on any non-conductive flat surface, temperature control devices or energy management systems see instructions and wiring diagram provided by manufacturer, Locate thermostat approximately 5 feet (1524 mm) above the floor in an area with good air circulation at average temperature, Avoid locating the room thermostat where it might be affected by: IMPORTANT-Terminal connections at the wall plate or subbase must be made securely, Loose control wire connections may allow unit to operate but not with proper response to room demand. -drafts or dead spots behind doors and in corners -hot or cold air from ducts -radiant heat from sun or appliances 24 VOLT FIELD WIRING WITH ELECTRONIC AND ELECTRO-MECHANICAL THERMOSTATS -concealed pipes and chimneys IMPORTANT - Unless field thermostat wires are rated for maximum unit voltage, they must be routed away from fine voltage wiring. Use wire ties located near the lower left corner of the controls hat section to secure thermostat TO CMC1 ; DO NOT REMOVE FACTORY INSTALLED WIRES cable. B - Control Wiring 1- Route thermostat cable or wires from subbase to control area above compressor (refer to unit dimensions to locate bottom and side power entry), I I I I I I I II I II I I,hl I I I III II I II I II I I I I I I I "iii I I I I 1¢iiii w_ _) G_ R_ C_ A_ V_ V_ Use18 AWG wire for all applications using remotely installed electro-mechanical and electronic thermostats, 2- Install thermostat assembly in accordance instructions provided with thermostat, A2 THERMOSTAT NOT ALLTERMINALS AREFOUND ONALL THERMOSTATS Jumper terminals Rand |OC when thermostat has | no night setback terminals. / Note - On electro-mechanical thermostats set anticipator at 0.1 amps. with FIGURE 11 Page 7 TYPICAL THA UNIT WIRING SCHEMATIC 24V /_ NOTE-FOR REFER TO AMPACITY ./2', $40 POWER USE WITH COPPER CONDUCTORS ONLY UNIT RATING PLATE FOR MINIMUM CIRCUIT AND MAXIMUa OVERCURRENT PROTECTION SIZE IS NOT REO'D ON 072 UNITS ECONOMIZER BLOIER(8) HEAT I(!l) HEAT 2(W2] COOL I(YI) ;5 )_ _5 • A6 \PIE ) • K65 ) / PII i Jlt )67 I P4 / DESCRIPTION COMPONENT CONTROL-SOLID STATE ENTHALPY DETECTOR-SMOKE. RETURN AIR DETECTOR-SMOKE, SUPPLY AIR COMPRESSOR MOTOR-BLOWER MOTOR-OUTDOOR FAN MOTOR-DAMPER.ECONOMIZER MOTOR-_XHAU_T FAN _APA_ITOR-OIITDOOR FAN CAPACITOR-BLOWER MOTOR CAPACITOR-EXHAUST FAN KEY A6 AI7 A64 81 B3 B_ 67 610 CI CA C6 J3 24V LI L2 \ J132 /_B_ PIS2 EXHAUST FAN MOTOR DISCONNECT ALL POWER BEFORE OPTIONAL VOLTAGE K3,-I K8.-I.2 _ONTACTOR-BLO_ER RELAY-TRANSFER K58_-I K65,-I,_ LI P4 PIG P35 P43 _45 P132 53 RELAY-LOW AMBIENT KIT RELAY-EXHAUST FAN CALVE-REVERSING _LUO-ECONOMIZER _LUB-EXHAUST FAN _LUO-TEST _LUG-BLO@ER MOTOR _LUG-INPUT _LUG-BLOIER.EXHAUST FAN MOTOR _WITCH-LIMIT,LOW COMP I /COMPRESSOR MONITOR ;WITCH-LIMIT,HI PRESS|MANUAL RESET ;WITCH-DEFROST. COMPRESSOR I ;WITCH-LOW PRESS.LOW AMP KIT FHERMOSTAT-CRANKCASE ;WITCH-FREEZESTAT _ITCH-FIRESTAT I ;WITCH-FIRESTAT 2 _WITCH-LOW PRESS. COMPRESSOR I PRANSFORMER-CONTROL COOLING IT Supersedes COMPONENTS FIELD WIRINGDIAGRAMLL _ UNITS-PACKAGED Form No. I I INSTALLED _) FIGURE 12 Page 8 I THA-036,04-8,060,072- I-Y 208-230/60/3 COOLING SECTION 633 WARNING-ELECTRIC SHOCK HAZARD,CAN CAUSE INJURY OR DEATH. UNIT MUST BE GROUNDED IN ACCORDANCE WITH NATIONAL AND LOCAL CODES DENOTES lAMER-DEFROST, COMPRESSOR I =USE-EXHAUST FAN 4EATER _OMPRE_OR JACK-HEAT JACK-UNIT ECONOMIZER JACK-EXHAUST FAN JACK-TEST JACK-BLOWER,EXHAUST FAN MOTOR 30NTACTOR-COMPRESSOR SERVICING NOTE-IF ANY WIRE IN THIS APPLIANCE IS REPLACEO, MUST BE REPLACED WITH WIRE OF LIKE SIZE, RATING, TERMINATION AND INSULATION THICKNESS. LINE CMCI F6 HRI J2 J3 JIB J35 3132 KI,-I $4 SB SII S€0 _¢g $74 S75 SB7 TI Pi3Z COMMON ZOO6 Net* Form No+ 535,026W Lliho U,S,A, . 2 and2-1/2ton unitsare equippedwith directdrive blowersonly.3,4,and5tonunitsareequipped witheither directdriveorbeltdriveblowers.060Sand072unitsare available withbeltdriveblowersonly. A, IMPORTANT If CFM is lower than the design specified CFM, move the lead from pressure tap 3 or 4 to pressure tap 2. See figure 14. Refer to table 14 for minimum airflow when electric heat is installed. For 460/575V units, remove the isolation lead from speed tap 2 before moving the wire to speed tap 2. Tape the exposed end of the isolation lead and secure away from other components. A - Blower Operation 1- Set thermostat Use tables 2 and 4, the measured static pressure, and the factory-set blower speed to determine CFM DIRECT DRIVE HIGH STATIC APPLICATIONS or temperature control device fan switch to AUTO orON. With fan switch in ON position, blower will operate continuously. With fan switch in AUTO position, the blower will cycle with demand. 2- Blower and entire unit will be off when thermostat or temperature control device system switch is in OFF TERMINAL 1 REMAINS AT COMMON MOVE CONNECTOR TO TERMINAL 2 FOR HIGH STATIC APPLICATIONS BLOWER MOTOR position. B - Determining Unit CFM - Direct Drive Blowers 1- The following measurements must be made with air filters in place. 2- With all access panels in place, measure static pressure external to unit (from supply to return). Add any additional air resistance for options and accessories shown in table 13. BLOWER SHAFT SPEED TAPS 3- Use figure 13 to determine the factory set blower speed. BLOWER SPEED FACTORY SETTINGS 036 Units 024, 030, 048 Units 2 Hi _1Com 3 Med 4 Low* 060 Units 2 Hi _1Com 3 Meal* 4 Low 2 _1Com 460/575V UNITS: Disconnect isolation lead before _ moving speed tap wire. Tape exposed end of isolation lead and secure away from other components. Hi 3 Low* 4 Unused FIGURE 14 *Factory Setting FIGURE 13 Page 9 [_ I_1 1 2 3 4 C - DeterminingUnitCFM- Belt DriveBlowers PULLEY ALIGNMENT 1- Thefollowingmeasurements mustbemadewithair filtersin place. ALIGNED 2- Withall accesspanelsin place,measurestatic pressureexternaltounit(fromsupplytoreturn). 3- MeasuretheindoorblowerwheelRPM. _ I MOTOR PULLEY Referring to tables 5 through 12, use static pressure and RPM readings to determine unit CFM, Use table BELT 13 when installing units with any of the options or accessories listed, Refer to table 14 for minimum airflow when electric heat is installed, NOT ALIGNED 5- The blower RPM can be adjusted at the motor pulley, Loosen Allen screw and turn adjustable pulley clockwise to increase CFM. Turn counterclockwise to decrease CFM See figure 16, Do not exceed minimum and maximum number of pulley turns as shown in table 1. TABLE 1 MINIMUM AND MAXIMUM PULLEY ADJUSTMENT t BLOWER PULLEY FIGURE 15 1- Loosen four bolts securing motor base to mounting frame. See figure 16, 2- To increase belt tension Slide blower motor downward to tighten the belt, This increases the distance between the blower motor and e,tt O'n. turn O Oaxi. turn en tO0en A Section D - Blower No minimum To loosen belt tension - Belt Adjustment Maximum life and wear can be obtained proper pulley alignment Tension the blower housing, 5 Slide blower motor upward to loosen the belt, This decreases the distance between the blower motor from belts only if and belt tension are maintained. and the blower housing, new belts after a 24-48 hour period of operation. This will allow belt to stretch and seat grooves. 3- Tighten Make sure blower and motor pulley are aligned as shown in figure 15, four bolts securing motor base to the mounting frame, BLOWER ASSEMBLY TO INCREASE LOOSEN TURN ALLEN CFM SCREW TO DECREASE & TURN PULLEY CLOCKWISE CFM PULLEY COUNTERCLOCKWISE SIDE VIEW MOTOR LOOSEN ALLEN SCREW TO ADJUST CFM _ ALLEN '-.. 7 TO INCREASE BELT TENSION 1-Loosen four bolts securing motor base to mounting frame. 2-Slide the motor downward to tighter the belt. 3-Tighten four bolts on motor base. LOOSEN FOUR BOLTS AND SLIDE BLOWER MOTOR DOWNWARD TO TIGHTEN BELT FIGURE 16 Page 10 E - Check Belt Tension F-Field-Furnished Overtensioning belts shortens Check belt tension as follows: belt and bearing life. Blower Drives For field-furnished blower drives, use tables 5 through 12 to determine BHP and RPM required. Reference table 15 to determine the drive kit number. 1- Measure span length X. See figure 17. 2- Apply perpendicular force to center of span (X) with enough pressure to deflect belt 1/64" for every inch of MEASURE BELT TENSION span length or 1.5mm per 100mm of span length. Example: Deflection distance of a 40" span would be 40/64" or 5/8". Example: Deflection would be 6mm. 3_ distance of a 400mm span Measure belt deflection force. For a used belt, the deflection force should be 5 Ibs. (35kPa). A new belt deflection force should be 7 Ibs. (48kPa). A force below these values indicates an undertensioned belt. A force above these values indicates an overtensioned DEFLECTION 1/64" PER INCH OF SPAN OR 1.5mm PER 100mm OF SPAN FIGURE 17 belt. Page 11 DIRECT External Static Pressure (in. w.g.) 208 VOLTS High I DRIVE Air Volume (cfm) at Various Blower Speeds 230 VOLTS Med,um I 2 and 2.5 Ton Standard Efficiency (Down-Flow) 0.0 1230 975 0.1 1220 940 0.2 1205 910 0.3 1185 880 0.4 1155 845 0.5 1115 800 0.6 1060 750 0.7 985 685 0.8 890 ...... 0.9 770 ...... 1.0 ......... 2 and 2.5 Ton Standard 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Efficiency 1165 1155 1140 1125 1095 1055 1005 935 845 730 ........ External Static Pressure (in. 208 VOLTS w.g.) High TABLE 2 BLOWER PERFORMANCE (Horizontal) 925 895 865 835 800 760 710 650 ..... ..... Low H,gh I Med,umI 845 815 775 730 680 ------- 1425 1395 1375 1350 1320 1280 1225 1150 1050 920 760 800 770 735 695 645 ---- 1350 1325 1300 1280 1250 1215 1160 1090 995 875 720 THA024S and THA030S 1065 865 1055 830 1030 800 1000 770 955 740 905 700 850 655 785 --720 --645 --...... Air Volume (cfm) at Various 230 VOLTS I Medium 3 and 4 Ton Basic Efficiency (Down-Flow) 0.0 2025 1635 0.1 1965 1605 I Low THA024S and THA030S 1125 910 1110 875 1085 845 1055 815 1010 780 955 740 895 690 830 --755 --680 --...... Low High Medium 1145 1145 2225 2140 Blower Speeds 460/575 VOLTS I Low High 1845 1805 1330 1325 2125 2075 I Medium I Low THA036B and THA048B 1750 1220 1715 1215 0.2 1910 1575 1135 2070 1770 1305 2025 1680 1205 0.3 0.4 1855 1800 1545 1500 1105 1055 2010 1950 1730 1680 1275 1225 1975 1915 1640 1595 1185 1155 0.5 1740 1445 995 1885 1620 1165 1850 1540 1105 0.6 1665 1370 910 1805 1540 1085 1770 1475 1040 0.7 0.8 1575 1460 1280 1165 810 --- 1705 1580 1440 1315 990 --- 1680 1570 1400 1310 950 --- 0.9 1325 1025 --- 1425 1155 --- 1445 1210 --- 1.0 1160 ...... 1230 ...... 1300 ...... 3 and 4 Ton Basic Efficiency 0.0 1920 (Horizontal) 1560 1090 2110 1760 1265 2125 THA036B and THA048B 1770 1265 0.1 0.2 1855 1805 1525 1490 1090 1075 2025 1955 1715 1675 1255 1235 2055 1990 1720 1675 1245 1230 0.3 1755 1455 1045 1900 1635 1205 1930 1635 1210 0.4 0.5 1700 1640 1415 1355 1000 940 1840 1775 1585 1525 1165 1100 1865 1795 1590 1535 1180 1130 0.6 1560 1280 855 1690 1440 1020 1715 1465 1050 0.7 1455 1180 750 1580 1330 920 1620 1370 935 0.8 0.9 1325 1155 1050 885 ----- 1435 1245 1180 995 ----- 1500 1365 1240 1075 ----- 1.0 940 ...... 1000 ...... 1195 ...... Page 12 DIRECT 3 Ton Standard Efficiency (Down-Flow) 0.0 1990 1625 0.1 1935 1595 DRIVE TABLE 3 BLOWER PERFORMANCE 1145 1145 2175 2100 1825 1790 1330 1320 2100 2050 1735 1705 THA036S 1220 1215 0.2 1885 1565 1130 2040 1755 1300 2000 1665 1205 0.3 0.4 1830 1775 1530 1485 1095 1050 1980 1915 1710 1660 1265 1215 1945 1885 1625 1575 1180 1145 0.5 1710 1425 980 1850 1595 1150 1815 1520 1095 0.6 0.7 1630 1540 1350 1255 900 800 1765 1660 1510 1405 1070 975 1735 1640 1450 1375 1025 940 0.8 1425 1140 --- 1535 1280 --- 1530 1285 --- 0.9 1285 1000 --- 1375 1120 --- 1405 1185 --- 1.0 1125 ...... 1180 ...... 1260 ...... 1090 1090 2060 1990 1740 1700 1265 1255 2085 2020 1745 1700 THA036S 1260 1240 3 Ton Standard 0.0 0.1 Efficiency (Horizontal) 1890 1545 1830 1515 0.2 1780 1480 1070 1930 1660 1230 1960 1660 1225 0.3 0.4 1730 1675 1445 1400 1040 995 1870 1810 1615 1565 1200 1150 1900 1835 1620 1575 1205 1170 0.5 1610 1340 930 1740 1500 1090 1760 1515 1115 0.6 1530 1260 845 1650 1410 1010 1680 1440 1035 0.7 0.8 1420 1290 1160 1025 745 --- 1535 1385 1295 1150 905 --- 1580 1460 1340 1210 915 --- 0.9 1120 865 --- 1195 965 --- 1320 1045 --- 1.0 910 ...... 960 ...... 1155 ...... Page 13 TABLE 4 DIRECT DRIVE BLOWER PERFORMANCE External Static Pressure (in. w.g.) Air Volume (cfm) at Various Blower Speeds 230 VOLTS 460/575 VOLTS 208 VOLTS Hig.I Medium I Low 4 Ton Standard Efficiency (Down-Flow) 0.0 1965 1615 0.1 1910 1585 Medium I Low I ed um I Low 1150 1145 2135 2070 1810 1775 1325 1315 2075 2025 1725 1690 THA048S 1220 1215 0.2 0.3 0.4 0.5 1860 1810 1750 1685 1555 1515 1465 1405 1125 1090 1035 970 2010 1950 1890 1815 1740 1695 1635 1565 1290 1255 1200 1135 1975 1920 1855 1785 1650 1610 1555 1500 1200 1175 1135 1085 0.6 0.7 0.8 1600 1505 1390 1325 1230 1115 885 785 --- 1730 1620 1490 1480 1375 1245 1055 955 --- 1700 1605 1495 1430 1350 1260 1015 925 --- 0.9 1.0 1250 1085 975 ...... --- 1330 1135 1085 ...... --- 1365 1220 1160 ...... --- 1090 2025 1725 1260 2055 1730 THA048S 1255 4 Ton Standard 0.0 Efficiency (Horizontal) 1865 1535 0.1 0.2 0.3 1810 1765 1710 1505 1470 1430 1085 1065 1035 1960 1905 1845 1685 1645 1600 1250 1225 1190 1995 1935 1870 1685 1650 1605 1240 1220 1200 0.4 0.5 0.6 0.7 1655 1585 1495 1390 1385 1320 1240 1135 985 915 835 730 1785 1710 1615 1495 1545 1475 1380 1265 1140 1075 990 890 1805 1730 1645 1545 1555 1495 1410 1310 1160 1100 1015 895 0.8 0.9 1.0 1250 1080 875 1000 835 ...... ----- 1340 1150 915 1115 930 ...... ----- 1425 1285 1115 1175 1010 ...... ----- External Static Pressure (in. 208 VOLTS High I 5 Ton Basic Efficiency (Down-Flow) 0.0 2180 230 VOLTS 4601575 VOLTS Low High I Low High I Low 1670 2360 1970 2300 THA060B 1745 0.1 0.2 0.3 2145 2110 2080 1655 1650 1640 2325 2290 2250 1935 1910 1880 2180 2090 2035 1710 1690 1680 0.4 0.5 0.6 2045 2005 1960 1630 1610 1580 2210 2165 2110 1855 1825 1785 1995 1965 1940 1670 1655 1635 0.7 0.8 0.9 1.0 1905 1835 1750 1645 1540 1480 1405 --- 2045 1970 1875 1765 1735 1670 1590 --- 1905 1855 1780 1670 1600 1545 1465 --- 1600 1600 2235 2195 1890 1870 2285 2225 THA060B 1800 1800 5 Ton Basic Efficiency (Horizontal) 0.0 2070 0.1 2030 0.2 0.3 0.4 0.5 1990 1945 1900 1850 1595 1580 1555 1525 2155 2110 2055 2000 1845 1815 1775 1725 2170 2120 2070 2020 1790 1775 1745 1710 0.6 0.7 0.8 0.9 1795 1730 1650 1560 1480 1425 1360 1280 1930 1855 1770 1675 1670 1610 1535 1450 1965 1895 1820 1730 1660 1600 1525 1440 1.0 1460 --- 1565 --- 1620 --- Page 14 BELT DRIVE 0.10 to 0.80 in. w.g. Air Volume (cfm) 0.10 RPM BHP Field TABLE BLOWER 5 PERFORMANCE 3 Ton Basic Efficiency (Down-Flow) 0.20 RPM BHP 0.30 RPM BHP Furnished Low Static External Static (in.w.g.) 0.40 0.50 RPM BHP RPM BHP - Drive THA036B 0.60 RPM BHP 0.70 RPM BHP Kit #1 0.80 RPM BHP Drive Kit #5 9OO 480 0.10 590 0.15 690 0.25 780 0.30 860 0.40 935 0.55 1005 0.65 1065 0.75 1000 510 0.10 610 0.20 705 0.25 790 0.35 870 0.45 945 0.55 1010 0.65 1075 9.80 1100 540 0.15 635 0.20 720 0.30 805 0.35 880 0.45 955 0.60 1020 0.70 1085 0.85 1200 570 0.15 660 0.25 740 0.30 820 0.40 895 0.50 965 0.60 1030 0.75 1095 9.85 1300 605 0.20 685 0.25 765 0.35 840 0.45 910 0.55 980 0.65 1045 0.80 1105 0.90 1400 640 0.25 715 0.30 790 0.40 860 0.50 930 0.60 995 0.70 1055 0.85 1115 9.95 1500 675 0.30 745 0.35 815 0.45 880 0.55 950 0.65 1010 0.75 1070 0.90 1130 1.00 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) RPM BHP High Static THA036B 3 Ton Basic Efficiency (Down-Flow) External Static (in.w.g.) 1.0 I 1.10 RPM BHP I RPM - Drive Kit #5 1.20 1.40 1.30 BHP RPM BHP RPM BHP RPM Field BHP 1.50 RPM 1.60 BHP RPM BHP 1.95 Furnished 900 1125 0.90 1185 1.00 1240 1.15 1290 1.30 1340 1.45 1390 1.60 1435 1.75 1480 1000 1135 0.90 1190 1.05 1245 1.20 1300 1.35 1350 1.50 1395 1.65 1440 1.80 1485 1.95 1100 1145 0.95 1200 1.10 1255 1.25 1305 1.40 1355 1.55 1405 1.70 1450 1.85 1495 2.05 1200 1155 1.00 1210 1.15 1265 1.30 1315 1.45 1365 1.60 1410 1.75 1460 1.95 1505 2.10 1300 1165 1.05 1220 1.20 1270 1.35 1325 1.50 1375 1.65 1420 1.80 1465 2.00 1510 2.15 1400 1175 1.10 1230 1.25 1280 1.40 1335 1.55 1380 1.70 1430 1.90 1475 2.05 1520 2.25 1500 1185 1.15 1240 1.30 1295 1.45 1345 1.60 1390 1.80 1440 1.95 1485 2.15 1530 2.30 0.10 to 0.80 in. w.g. Air Volume (cfm) 0.10 RPM Field BHP 0.20 RPM External Static (in.w.g.) 0.40 0.50 0.30 BHP RPM BHP Furnished 9OO 475 0.10 1000 510 1100 545 1200 1300 THA036B 3 Ton Basic Efficiency (Horizontal) RPM BHP Low Static RPM BHP 0.60 0.70 0.80 RPM BHP RPM BHP RPM BHP - Drive Kit #1 565 0.15 650 0.20 725 0.30 800 0.35 870 0.45 930 0.55 990 0.65 0.10 590 0.15 665 0.25 740 0.30 815 0.40 880 0.50 940 0.60 1000 0.70 0.15 615 0.20 690 0.25 760 0.35 825 0.40 890 0.50 950 0.60 1010 0.75 585 0.20 650 0.25 715 0.30 780 0.40 845 0.45 905 0.55 965 0.65 1020 0.75 625 0.25 680 0.30 740 0.35 800 0.40 860 0.50 920 0.60 980 0.70 1030 0.80 1400 665 0.30 715 0.35 770 0.40 830 0.50 885 0.55 940 0.65 995 0.75 1045 0.85 1500 705 0.35 750 0.40 805 0.45 855 0.55 910 0.60 960 0.70 1010 0.80 1065 0.90 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) RPM BHP High Static 9OO 1045 0.75 THA036B 3 Ton Basic Efficiency (Horizontal) External Static (in.w.g.) 1.0 I 1.10 RPM BHP I RPM - Drive Kit #5 1100 0.90 1150 1.20 1.30 1.40 1.50 1.60 RPM BHP BHP RPM BHP RPM BHP RPM BHP RPM BHP 1.00 1195 1.10 1240 1.25 1285 1.40 1325 1.50 1365 1.65 Field 1000 1055 0.80 1105 0.90 1155 1.05 1205 1.15 1250 1.30 1295 1.45 1335 1.55 1375 1.70 1100 1065 0.85 1115 0.95 1165 1.10 1215 1.20 1260 1.35 1305 1.50 1345 1.60 1385 1.75 1200 1075 0.90 1125 1.00 1175 1.15 1220 1.25 1270 1.40 1310 1.55 1355 1.70 1395 1.80 1300 1085 0.90 1135 1.05 1185 1.20 1230 1.30 1275 1.45 1320 1.60 1365 1.75 1405 1.90 1400 1100 1.00 1150 1.10 1195 1.25 1240 1.35 1285 1.50 1330 1.65 1370 1.80 1415 1.95 1500 1115 1.05 1160 1.15 1210 1.30 1255 1.45 1295 1.55 1340 1.70 1380 1.85 1420 2.00 Page 15 BELT DRIVE 0.10 to 1.00 in. w.g. Air Volume (cfm) Field BHP 6 PERFORMANCE THA036S 3 Ton Standard Efficiency (Down-Flow) External Static (in.w.g.) 0.10 RPM TABLE BLOWER 0.20 RPM 0.30 BHP RPM Furnished 0.40 BHP RPM 0.50 BHP 0.60 0.70 0.80 RPM BHP RPM BHP RPM BHP BHP Low Static 9OO 485 0.10 595 0.15 690 0.20 780 0.30 860 0.40 930 0.50 1000 0.60 1065 0.75 1000 520 0.10 615 0.20 705 0.25 790 0.35 870 0.45 945 0.55 1010 0.65 1075 0.75 1100 550 0.15 640 0.20 725 0.30 805 0.35 885 0.45 955 0.55 1020 0.70 1085 0.80 1200 585 0.20 665 0.25 745 0.30 825 0.40 900 0.50 965 0.60 1030 0.70 1095 0.85 1300 620 0.20 695 0.30 770 0.35 845 0.45 915 0.55 980 0.65 1045 0.75 1105 0.90 1400 660 0.25 730 0.35 795 0.40 865 0.50 935 0.60 995 0.70 1060 0.80 1120 0.95 1500 695 0.30 760 0.40 825 0.45 890 0.55 955 0.65 1015 0.75 1075 0.85 1135 1.00 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) RPM BHP High Static 900 1125 0.85 - Drive Kit #1 RPM Kit 5 THA036S 3 Ton Standard Efficiency (Down-Flow) External Static (in.w.g.) 1.0 I 1.10 RPM BHP I RPM - Drive Kit #5 1180 1.00 1230 1.20 BHP RPM 1.40 1.30 BHP RPM BHP RPM Field BHP 1.50 RPM 1.60 BHP RPM BHP Furnished 1.10 1285 1.25 1330 1.35 1380 1.50 1425 1.65 1465 1.80 1000 1130 0.90 1190 1.00 1240 1.15 1295 1.30 1340 1.40 1390 1.60 1435 1.75 1475 1.85 1100 1140 0.90 1200 1.05 1250 1.20 1300 1.35 1350 1.50 1400 1.65 1445 1.80 1485 1.95 1200 1150 0.95 1210 1.10 1260 1.25 1310 1.40 1360 1.55 1410 1.70 1455 1.85 1495 2.00 1300 1165 1.00 1220 1.15 1270 1.30 1320 1.45 1370 1.60 1415 1.75 1465 1.90 1505 2.05 1400 1175 1.05 1230 1.20 1280 1.35 1330 1.50 1380 1.65 1425 1.80 1470 1.95 1515 2.15 1500 1190 1.15 1240 1.25 1295 1.40 1345 1.55 1390 1.70 1435 1.90 1480 2.05 1525 2.20 0.10 to 0.80 in. w.g. Air Volume 0.10 (cfm) RPM BHP Field THA036S 3 Ton Standard Efficiency (Horizontal) 0.20 RPM External Static (in.w.g.) 0.40 0.50 0.30 BHP RPM BHP Furnished RPM BHP Low Static RPM BHP 0.60 0.70 0.80 RPM BHP RPM BHP RPM BHP - Drive Kit #1 900 480 0.10 570 0.15 655 0.20 735 0.30 810 0.35 875 0.45 940 0.55 1000 0.65 1000 520 0.15 595 0.15 675 0.25 750 0.30 820 0.40 890 0.50 950 0.60 1010 0.70 1100 555 0.15 625 0.20 695 0.25 765 0.35 835 0.45 900 0.50 960 0.60 1020 0.75 1200 595 0.20 660 0.25 725 0.30 790 0.40 850 0.45 915 0.55 975 0.65 1030 0.75 1300 635 0.25 690 0.30 750 0.35 810 0.40 870 0.50 930 0.60 990 0.70 1045 0.80 1400 675 0.30 730 0.35 785 0.40 840 0.50 895 0.55 950 0.65 1005 0.75 1060 0.85 1500 720 0.35 765 0.40 815 0.45 870 0.55 920 0.60 970 0.70 1025 0.80 1075 0.95 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) RPM BHP High Static 9OO 1055 0.75 THA036S 3 Ton Standard Efficiency (Horizontal) External Static (in.w.g.) 1.0 I 1.10 RPM BHP I RPM - Drive Kit #5 1105 0.90 1155 1.20 BHP RPM BHP 1.30 RPM BHP 1.40 RPM BHP 1.50 RPM BHP 1.00 1200 1.10 1245 1.25 1285 1.35 1325 1.50 1.60 RPM BHP Field 1365 1.60 1000 1065 0.80 1115 0.90 1165 1.05 1210 1.15 1255 1.30 1300 1.40 1340 1.55 1380 1.70 1100 1075 0.85 1125 0.95 1175 1.10 1220 1.20 1265 1.35 1310 1.50 1350 1.60 1395 1.75 1200 1085 0.90 1135 1.00 1185 1.15 1235 1.25 1280 1.40 1320 1.55 1365 1.70 1405 1.85 1300 1095 0.95 1145 1.05 1195 1.20 1245 1.30 1290 1.45 1330 1.60 1375 1.75 1415 1.90 1400 1110 1.00 1160 1.10 1210 1.25 1255 1.40 1300 1.50 1340 1.65 1385 1.80 1425 1.95 1500 1125 1.05 1175 1.15 1220 1.30 1265 1.45 1310 1.60 1355 1.75 1395 1.85 1435 2.05 Page 16 BELT DRIVE 0.10to 0.80 Air Volume (cfm) 1200 1300 1400 1500 1600 1700 1800 1900 2000 in. w.g. 0.10 0.20 RPM BHP RPM BHP Field Furnished 570 0.15 655 0.20 605 0.20 680 0.25 640 0.25 710 0.30 675 0.25 740 0.35 710 0.30 775 0.40 745 0.40 805 0.45 785 0.45 840 0.50 820 860 0.50 0.60 875 910 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) 0.60 0.65 1.00 RPM - Drive 1190 1200 1210 1225 1235 TABLE BLOWER 7 PERFORMANCE 4 Ton Basic Efficiency (Down-Flow) External Static (in.w.g.) 0.30 0.40 0.50 0.60 RPM BHP RPM BHP RPM BHP RPM BHP Low Static - Drive Kit #2 735 0.30 815 0.35 885 0.45 955 0.55 0.70 RPM BHP 0.80 RPM BHP 1015 0.65 1075 0.75 760 785 810 835 865 895 0.30 0.35 0.40 0.45 0.50 0.60 830 855 875 900 925 955 0.40 0.45 0.50 0.55 0.60 0.70 900 920 940 960 985 1010 0.50 0.55 0.60 0.65 0.70 0.80 965 985 1000 1020 1040 1065 0.60 0.65 0.70 0.75 0.80 0.90 1030 1045 1060 1080 1095 1115 0.70 0.75 0.80 0.85 0.90 1.00 1090 1100 1115 1135 1150 1170 0.80 0.85 0.90 0.95 1.05 1.10 930 960 0.65 0.75 980 1010 0.75 0.85 1035 1065 0.85 0.95 1090 1115 0.95 1.05 1140 1165 1.10 1.15 1190 1210 1.20 1.30 THA048B 4 Ton Basic Efficiency (Down-Flow) External Static (in.w.g.) 1.10 1.20 1.30 I THA048B BHP I RPM Kit #6 1.00 1240 1.05 1250 1.10 1260 1.15 1275 1.20 1285 BHP RPM BHP RPM BHP RPM 1.40 BHP 1.10 1.15 1.20 1.30 1.35 1290 1300 1310 1325 1335 1.25 1.30 1.35 1.40 1.50 1340 1350 1360 1370 1380 1.35 1.45 1.50 1.55 1.60 1.50 1.55 1.65 1.70 1.75 1.85 1.50 1.60 RPM BHP RPM BHP Field Furnished 1430 1.65 1475 1.80 1440 1.70 1485 1.85 1450 1.75 1490 1.90 1460 1.85 1500 2.00 1470 1.90 1515 2.10 1480 2.00 1525 2.15 1.90 2.00 2.10 1495 1505 1520 1200 1300 1400 1500 1600 RPM BHP High Static 1135 0.85 1145 0.90 1160 0.95 1170 1.00 1185 1.10 1700 1200 1.15 1255 1.30 1300 1.40 1350 1.55 1395 1.70 1385 1395 1405 1415 1425 1440 1800 1900 2000 1220 1240 1260 1.25 1.30 1.40 1270 1285 1305 1.35 1.45 1.55 1315 1335 1350 1.50 1.60 1.70 1365 1380 1395 1.65 1.75 1.80 1410 1420 1440 1.80 1.85 2.00 1450 1465 1480 0.10 to 0.80 in. w.g. Air Volume 0.10 0.20 (cfm) RPM BHP RPM BHP Field Furnished 1200 580 0.15 645 0.20 1300 620 0.20 675 0.25 1400 660 0.25 710 0.30 4 Ton Basic Efficiency (Horizontal) External Static (in.w.g.) 0.30 0.40 0.50 RPM BHP RPM BHP RPM BHP Low Static - Drive Kit #2 710 0.25 770 0.35 835 0.40 735 0.30 795 0.35 855 0.45 765 0.35 820 0.40 875 0.50 2.10 2.15 2.25 0.60 RPM BHP 0.70 RPM BHP 0.80 RPM BHP 895 910 930 0.50 0.50 0.55 950 0.55 965 0.60 1005 1020 1035 0.65 0.70 0.75 1050 1070 1090 1115 1140 0.80 0.85 0.95 1.00 1.10 985 0.65 700 740 780 820 860 0.30 0.35 0.45 0.50 0.60 745 785 820 860 900 0.35 0.40 0.50 0.55 0.65 800 830 865 900 940 0.40 0.45 0.55 0.60 0.70 850 880 910 945 980 0.50 0.55 0.60 0.70 0.80 900 930 955 985 1020 0.55 0.60 0.70 0.75 0.85 950 975 1000 1030 1060 0.60 0.70 0.75 0.85 0.95 1000 0.70 1025 0.80 1045 0.85 1070 0.90 1100 1.00 2000 905 0.70 940 0.75 975 0.80 1015 0.90 1050 0.95 1090 1.05 1130 1.10 1.00 RPM BHP High Static 1110 0.85 1120 0.90 4 Ton Basic Efficiency (Horizontal) External Static (in.w.g.) I 1.10 1.20 1.30 I RPM BHP RPM BHP RPM BHP - Drive Kit #6 1155 0.95 1205 1.05 1245 1.15 1165 1.00 1210 1.10 1255 1.20 2.25 2.35 2.45 THA048B 1500 1600 1700 1800 1900 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) RPM BHP Kit 2 1200 1060 0.75 1300 1070 0.80 1400 1085 0.85 1500 1100 0.90 1535 1550 1560 1165 1.20 THA048B 1.40 RPM BHP 1.50 RPM BHP 1.60 RPM BHP 1290 1300 1.30 1.35 1330 1340 1.40 1.45 1370 1380 1.55 1.60 1130 1145 0.95 1.00 1180 1190 1.05 1.10 1225 1235 1.15 1.20 1265 1280 1.25 1.35 1310 1320 1.40 1.45 1350 1360 1.50 1.60 1390 1400 1.65 1.70 1600 1700 1800 1900 1115 1135 1155 1180 0.95 1.05 1.10 1.20 1160 1180 1200 1220 1.05 1.15 1.20 1.30 1205 1220 1240 1260 1.15 1.25 1.35 1.40 1250 1265 1280 1300 1.30 1.35 1.45 1.55 1290 1305 1320 1340 1.40 1.50 1.55 1.65 1330 1345 1360 1375 1.50 1.60 1.70 1.75 1370 1385 1400 1415 1.65 1.75 1.80 1.90 1410 1425 1435 1450 1.80 1.85 1.95 2.05 2000 1205 1.30 1245 1.40 1280 1.50 1320 1.65 1355 1.75 1395 1.90 1430 2.00 1465 2.15 Page 17 0.10to 0.80 Air Volume (cfm) 1200 1300 1400 1500 1600 1700 1800 1900 2000 in. w.g. 0.10 0.20 RPM BHP RPM BHP Field Furnished 590 0.15 670 0.20 630 0.20 700 0.25 670 0.25 735 0.30 705 0.30 765 0.35 745 785 825 865 910 0.35 0.40 0.50 0.55 0.65 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) RPM BHP High Static 1200 1135 0.80 1300 1145 0.85 800 840 875 915 950 0.40 0.50 0.55 0.65 0.70 0.60 RPM BHP 0.70 RPM BHP 0.80 RPM BHP 955 970 990 0.50 0.55 0.60 1020 1035 1050 0.60 0.65 0.70 1080 1090 1105 0.70 0.75 0.80 830 860 895 925 960 995 1010 1030 1055 1080 1105 1135 0.65 0.70 0.80 0.85 0.95 1.05 1070 1085 1110 1130 1155 1180 0.75 0.80 0.90 0.95 1.05 1.15 1125 1140 1160 1180 1205 1230 0.85 0.90 1.00 1.05 1.15 1.25 0.40 0.50 0.55 0.60 0.70 0.80 890 0.50 920 0.55 945 0.60 980 0.70 1010 0.80 1045 0.90 950 975 1000 1030 1060 1090 0.55 0.65 0.70 0.80 0.85 0.95 THA048S THA048S 4 Ton Standard Efficiency (Down-Flow) External Static (in.w.g.) 1.10 1.20 1.30 BHP I RPM Kit #6 0.90 1235 0.95 1250 BHP RPM BHP RPM BHP RPM BHP RPM BHP 1.00 1.05 1285 1300 1.15 1.20 1330 1345 1.25 1.30 1375 1390 1.35 1.45 1.50 1.55 1.60 1.70 1.60 RPM BHP Field 1460 1.60 1475 1.70 1485 1.75 1500 1.85 1.00 RPM - Drive 1185 1200 TABLE 8 BELT DRIVE BLOWER PERFORMANCE 4 Ton Standard Efficiency (Down-Flow) External Static (in.w.g.) 0.30 0.40 0.50 RPM BHP RPM BHP RPM BHP Low Static - Drive Kit #2 745 0.30 820 0.35 890 0.45 770 0.30 840 0.40 910 0.45 800 0.35 865 0.45 930 0.50 I 1.40 1.50 1400 1500 1160 1175 0.90 0.95 1215 1225 1.00 1.05 1265 1275 1.15 1.20 1310 1325 1.25 1.30 1355 1370 1.35 1.45 1400 1415 1.50 1.55 1420 1435 1445 1460 1600 1700 1800 1900 1195 1210 1230 1250 1.05 1.10 1.20 1.25 1245 1260 1275 1295 1.15 1.20 1.30 1.40 1290 1305 1325 1340 1.25 1.35 1.40 1.50 1340 1355 1370 1385 1.40 1.45 1.55 1.65 1385 1400 1415 1430 1.50 1.60 1.70 1.75 1430 1440 1455 1470 1.65 1.70 1.80 1.90 1470 1485 1500 1515 1.75 1.85 1.95 2.05 1510 1525 1540 1555 2000 1275 1.35 1320 1.50 1360 1490 2.00 1530 2.15 1570 2.30 THA048S 0.60 RPM BHP 0.70 RPM BHP 0.80 RPM BHP 915 935 955 975 0.50 0.55 0.60 0.65 975 990 1005 1025 0.60 0.60 0.65 0.75 1030 1045 1060 1075 0.70 0.70 0.75 0.80 1.60 1405 1.75 1445 1.85 4 Ton Standard Efficiency (Horizontal) External Static (in.w.g.) 0.30 0.40 0.50 RPM BHP RPM BHP RPM BHP Low Static - Drive Kit #2 725 0.25 790 0.35 855 0.40 755 0.30 815 0.40 875 0.45 790 0.35 845 0.45 900 0.50 820 0.40 870 0.50 925 0.55 0.10 to 0.80 in. w.g. Air Volume 0.10 0.20 (cfm) RPM BHP RPM BHP Field Furnished 1200 600 0.20 660 0.20 1300 640 0.20 695 0.25 1400 685 0.25 735 0.30 1500 725 0.35 770 0.35 1.90 2.00 2.10 2.20 1600 1700 1800 1900 770 810 855 900 0.40 0.45 0.55 0.65 810 850 890 935 0.45 0.50 0.60 0.70 855 895 930 970 0.50 0.55 0.65 0.75 905 935 970 1010 0.55 0.65 0.70 0.80 950 980 1015 1050 0.60 0.70 0.80 0.90 1000 1030 1055 1090 0.70 0.80 0.85 0.95 1050 1075 1100 1130 0.80 0.85 0.95 1.05 1095 1120 1145 1170 0.90 0.95 1.05 1.15 2000 940 0.75 975 0.80 1010 0.85 1045 0.90 1085 1.00 1120 1.05 1160 1.15 1195 1.25 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) RPM BHP High Static 1200 1080 0.75 1300 1095 0.80 1400 1110 0.85 1500 1125 0.90 4 Ton Standard 1.0 RPM - Drive 1130 1145 1160 1175 I Efficiency 1.10 THA048S (Horizontal) External Static (in.w.g.) 1.20 1.30 1.40 1.50 1.60 BHP I RPM Kit #6 0.85 1180 0.90 1190 1.00 1205 1.05 1220 BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1.00 1.00 1.10 1.15 1225 1235 1250 1265 1.10 1.15 1.20 1.25 1265 1280 1295 1305 1.20 1.25 1.30 1.35 1305 1320 1335 1350 1.30 1.35 1.45 1.50 1345 1360 1375 1390 1.40 1.50 1.55 1.65 1.55 1.60 1.70 1.75 1.80 1.90 1600 1700 1145 1165 1.00 1.05 1190 1210 1.10 1.15 1235 1255 1.20 1.30 1280 1295 1.35 1.40 1320 1335 1.45 1.50 1365 1380 1.60 1.65 1405 1415 1.70 1.75 1385 1400 1415 1430 1440 1455 1800 1900 1185 1210 1.15 1.25 1230 1250 1.25 1.35 1270 1290 1.35 1.45 1315 1330 1.50 1.55 1355 1370 1.60 1.70 1395 1410 1.75 1.80 1430 1450 1.85 1.95 1470 1485 2.00 2.10 2000 1235 1.35 1275 1.45 1315 1.55 1355 1.70 1390 1.80 1430 1.95 1465 2.05 1500 2.20 Page 18 BELT DRIVE 0.10to 0.80 Air Volume (cfm) 1600 1700 in. w.g. 0.10 0.20 RPM BHP RPM BHP Field Furnished 705 0.30 765 0.35 740 0.35 800 0.40 TABLE BLOWER 9 PERFORMANCE 5 Ton Basic Efficiency (Down-Flow) External Static (in.w.g.) 0.30 0.40 0.50 0.60 RPM BHP RPM BHP RPM BHP RPM BHP Low Static - Drive Kit #3 825 0.40 880 0.50 935 0.55 990 0.60 THA060B 0.70 RPM BHP 0.80 RPM BHP 1040 0.70 1090 0.75 1800 1900 2000 2100 2200 780 815 855 890 930 0.40 0.50 0.55 0.65 0.70 835 870 905 940 975 0.50 0.55 0.60 0.70 0.80 855 885 920 950 985 1020 0.50 0.55 0.60 0.70 0.80 0.85 910 940 970 1000 1030 1065 0.55 0.60 0.70 0.75 0.85 0.95 960 990 1015 1045 1075 1105 0.60 0.70 0.75 0.85 0.95 1.05 1010 1035 1065 1090 1120 1145 0.70 0.75 0.85 0.90 1.00 1.10 1060 1085 1110 1135 1160 1190 0.75 0.85 0.90 1.00 1.10 1.20 1110 1130 1155 1180 1205 1230 0.85 0.90 1.00 1.10 1.20 1.30 2300 2400 970 1005 0.80 0.90 1010 1050 0.90 1.00 1055 1090 0.95 1.10 1095 1130 1.05 1.15 1135 1170 1.15 1.25 1175 1210 1.20 1.35 1215 1245 1.30 1.45 1255 1285 1.40 1.55 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) RPM BHP Low Static #3 1600 1135 0.85 1700 1155 0.90 1800 1175 1.00 1900 1200 1.10 2000 2100 2200 2300 2400 1220 1245 1270 1295 1320 1.15 1.25 1.40 1.50 1.60 1.00 RPM BHP - Drive Kit 5 Ton Basic Efficiency (Down-Flow) External Static (in.w.g.) 1.10 1.20 1.30 RPM BHP RPM BHP RPM BHP High Static 1275 1290 1.10 1.20 1315 1330 1.20 1.30 1355 1370 1.30 1.35 1400 1410 1.40 1.45 1440 1450 1.50 1.60 1220 1240 1.10 1.15 1265 1280 1.15 1.25 1305 1325 1.25 1.35 1345 1365 1.35 1.45 1385 1400 1.45 1.55 1425 1440 1.55 1.65 1465 1480 1.65 1.75 1260 1285 1310 1335 1360 1.25 1.35 1.50 1.60 1.70 1300 1325 1345 1370 1395 1.35 1.45 1.55 1.70 1.80 1340 1360 1385 1405 1430 1.45 1.55 1.65 1.80 1.90 1380 1400 1420 1445 1465 1.55 1.65 1.75 1.90 2.05 1420 1440 1460 1480 1500 1.65 1.75 1.90 2.00 2.15 1455 1475 1495 1515 1535 1.75 1.85 2.00 2.10 2.25 1495 1510 1530 1550 1570 1.85 1.95 2.10 2.20 2.35 5 Ton Basic Efficiency (Horizontal) External Static (in.w.g.) 0.30 0.40 0.50 0.60 RPM BHP RPM BHP RPM BHP RPM BHP Low Static - Drive Kit #3 825 0.45 875 0.50 925 0.55 975 0.65 0.70 RPM BHP 0.80 RPM BHP 1025 0.70 1070 0.80 0.50 0.60 0.65 0.75 0.85 0.95 1.10 905 940 975 1010 1045 1080 1115 0.55 0.65 0.75 0.80 0.90 1.05 1.15 955 985 1015 1045 1080 1115 1150 0.65 0.70 0.80 0.90 1.00 1.10 1.20 1000 1025 1055 1085 1115 1150 1185 0.70 0.80 0.85 0.95 1.05 1.20 1.30 1045 1070 1095 1125 1155 1185 1215 0.80 0.85 0.95 1.05 1.15 1.25 1.35 1090 1115 1140 1165 1190 1220 1250 0.85 0.95 1.05 1.10 1.20 1.35 1.45 1.20 1155 1.30 1185 1.35 1215 1.45 1250 1.50 1280 1.60 0.50 0.55 0.65 0.75 0.85 0.95 855 895 935 970 1010 1050 0.55 0.60 0.70 0.80 0.90 1.00 2400 1065 1.10 1095 1.15 1125 2400 1315 1.70 - Drive Kit #7 1.00 1.10 815 855 895 940 980 1020 1.00 1.10 1.20 1.30 1.40 1.55 1.60 RPM BHP 1230 1245 1800 1900 2000 2100 2200 2300 1155 1180 1205 1230 1255 1285 1.50 RPM BHP 0.95 1.00 860 895 935 970 1005 1045 1085 1800 1900 2000 2100 2200 2300 1.40 RPM BHP 1185 1200 0.10 to 0.80 in. w.g. Air Volume 0.10 0.20 (cfm) RPM BHP RPM BHP Field Furnished 1600 735 0.35 780 0.40 1700 775 0.40 815 0.45 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) RPM BHP Low Static 1600 1120 0.90 1700 1135 0.95 THA060B 5 Ton Basic Efficiency (Horizontal) External Static (in.w.g.) 1.20 1.30 1.00 I 1.10 RPM BHP RPM BHP RPM BHP I RPM BHP - Drive Kit #3 High Static - Drive Kit #7 1165 1.00 1210 1.10 1255 1.20 1295 1.30 1180 1.05 1225 1.15 1270 1.25 1310 1.35 1200 1.10 1240 1.20 1285 1.30 1325 1.45 1220 1.20 1260 1.30 1300 1.40 1340 1.50 1245 1.30 1280 1.40 1320 1.50 1360 1.60 1265 1.40 1305 1.50 1340 1.60 1380 1.70 1290 1.50 1330 1.60 1365 1.70 1400 1.85 1320 1.65 1355 1.75 1385 1.85 1420 1.95 1345 1.75 1380 1.90 1415 2.00 Page 19 1445 2.10 THA060B THA060B 1.40 RPM BHP 1.50 RPM BHP 1.60 RPM BHP 1340 1350 1365 1380 1395 1415 1435 1455 1.40 1.45 1.55 1.65 1.70 1.80 1.95 2.05 1380 1390 1405 1415 1435 1450 1470 1490 1.50 1.60 1.65 1.75 1.85 1.95 2.05 2.20 1420 1430 1440 1455 1470 1485 1505 1520 1.65 1.70 1.75 1.85 1.95 2.05 2.15 2.30 1480 2.20 1510 2.30 1545 2.45 BELT DRIVE 0.10to 0.80 Air Volume (cfm) 1600 1700 1800 1900 2000 2100 2200 2300 2400 in. w.g. 0.10 0.20 RPM BHP RPM BHP Field Furnished 675 0.30 730 0.35 710 0.35 760 0.40 745 0.45 795 0.50 780 0.50 830 0.55 820 855 890 930 965 0.60 0.65 0.75 0.85 0.95 10 PERFORMANCE 5 Ton Standard Efficiency (Down-Flow) External Static (in.w.g.) 0.30 0.40 0.50 RPM BHP RPM BHP RPM BHP Low Static - Drive Kit #3 785 0.40 835 0.45 885 0.50 815 0.45 860 0.50 910 0.60 845 0.55 890 0.60 935 0.65 875 0.60 920 0.65 965 0.75 905 0.70 950 0.75 990 0.80 940 0.80 980 0.85 1020 0.90 970 0.85 1010 0.95 1050 1.00 1005 1.00 1045 1.05 1080 1.10 1040 1.10 1075 1.15 1115 1.25 5 Ton Standard Efficiency (Down-Flow) 0.90 to 1.60 in. w.g. Air External Static (in.w.g.) Volume 1.30 0.90 1.00 I 1.10 1.20 (cfm) RPM BHP RPM BHP RPM BHP I RPM BHP RPM I BHP Low Static - Drive Kit #3 High Static 1600 1075 0.80 1120 0.85 1160 0.95 1200 1.05 1240 1.10 1700 1090 0.85 1135 0.95 1175 1.00 1215 1.10 1255 1.20 1800 1110 0.95 1155 1.00 1195 1.10 1230 1.20 1270 1.25 1900 1135 1.05 1170 1.10 1210 1.20 1250 1.25 1285 1.35 2000 1155 1.10 1195 1.20 1230 1.30 1270 1.35 1305 1.45 2100 1180 1.20 2200 1200 1.30 2300 1225 1.45 2400 1255 1.55 0.10 to 0.80 in. w.g. Air Volume 0.10 (cfm) RPM BHP Field 1600 785 0.40 1700 825 0.45 865 900 935 970 1005 TABLE BLOWER 0.65 0.70 0.80 0.90 1.05 THA060S 0.60 RPM BHP 0.70 RPM BHP 0.80 RPM BHP 935 960 980 1010 0.60 0.65 0.70 0.80 985 1005 1025 1050 0.65 0.70 0.80 0.85 1030 1050 1070 1090 1035 1060 1090 1120 1150 0.90 1.00 1.10 1.20 1.30 1075 1100 1130 1155 1185 0.95 1.05 1.15 1.25 1.40 1115 1.05 1140 1.15 1165 1.25 1190 1.35 1220 1.50 THA060S 1.50 RPM BHP 1.60 RPM BHP 1.40 RPM BHP - Drive Kit #7 1280 1.20 1320 0.70 0.80 0.85 0.95 1.30 1355 1.35 1295 1310 1325 1340 1.30 1.35 1.45 1.55 1330 1345 1360 1375 1.35 1.45 1.55 1.65 1365 1380 1395 1410 1.45 1.55 1.65 1.75 1250 1.40 1290 1.45 1325 1.55 1275 1.50 1310 1.60 1345 1.70 1295 1.60 1330 1.70 1365 1.80 1320 1.75 1355 1.85 1385 1.90 5 Ton Standard Efficiency (Horizontal) External Static (in.w.g.) 0.20 I 0.30 0.40 0.50 RPM BHP I RPM BHP RPM BHP RPM BHP Low Static - Drive Kit #3 845 0.45 900 0.50 955 0.55 1010 0.65 880 0.50 935 0.60 990 0.65 1040 0.70 1360 1380 1400 1420 1.65 1.80 1.90 2.05 1395 1410 1430 1450 1.75 1.85 2.00 2.10 1425 1.85 1445 1.95 1465 2.10 1480 2.20 THA060S 0.60 RPM BHP 0.70 RPM BHP 0.80 RPM BHP 1060 1090 0.70 0.80 1110 1135 0.80 0.85 1160 1185 0.90 0.95 1215 1240 1260 1285 1.30 1.40 1.50 1.65 1800 1900 2000 865 910 950 0.50 0.60 0.70 920 960 1000 0.60 0.70 0.80 975 1010 1050 0.65 0.75 0.85 1020 1060 1095 0.75 0.85 0.95 1070 1105 1140 0.80 0.90 1.00 1120 1150 1185 0.90 1.00 1.10 1165 1195 1225 0.95 1.05 1.15 1210 1240 1265 1.05 1.15 1.25 2100 2200 995 1040 0.80 0.95 1040 1085 0.90 1.00 1085 1125 0.95 1.10 1130 1170 1.05 1.15 1175 1210 1.15 1.25 1215 1250 1.20 1.35 1260 1290 1.30 1.40 1300 1330 1.40 1.50 2300 2400 1080 1125 1.05 1.20 1125 1165 1.15 1.25 1165 1205 1.20 1.35 1205 1245 1.30 1.45 1245 1285 1.40 1.55 1285 1320 1.45 1.60 1325 1360 1.55 1.70 1360 1.65 1395 1.80 THA060S 1.40 RPM BHP 1.50 RPM BHP 1.60 RPM BHP 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) RPM BHP Drive Kit #3 1600 1210 0.95 1700 1230 1.05 5 Ton Standard Efficiency (Horizontal External Static (in.w.g.) 1.00 I 1.10 1.20 1.30 RPM BHP I RPM BHP RPM BHP RPM BHP High Static - Drive Kit #7 1255 1.05 1305 1.15 1350 1.30 1395 1.40 1440 1.55 1485 1.65 1530 1.80 1.15 1.25 1.35 1.45 1.55 1320 1340 1365 1390 1415 1.25 1.35 1.45 1.55 1.65 1365 1385 1405 1430 1455 1.35 1.45 1.55 1.65 1.80 1410 1425 1445 1470 1490 1.45 1.55 1.65 1.75 1.90 1455 1470 1485 1505 1530 1.60 1.70 1.75 1.85 2.00 1495 1510 1525 1545 1.70 1.80 1.90 2.00 1540 1550 1565 1585 1.85 1.95 2.00 2.15 1565 2.10 1605 2.25 1800 1900 2000 2100 1255 1280 1310 1340 1.15 1.25 1.35 1.50 1275 1300 1325 1350 1375 2200 2300 1370 1400 1.60 1.75 1405 1435 1.70 1.85 1445 1470 1.80 1.95 1480 1510 1.90 2.05 1515 1545 2.00 2.20 1555 1580 2.15 2.30 1590 1615 2.25 2.40 1625 1650 2.40 2.55 2400 1430 1.90 1465 2.00 1505 2.15 1535 2.20 1570 2.35 1605 2.45 1640 2.60 1675 2.70 Page 20 TABLE 11 BELT DRIVE BLOWER PERFORMANCE 0.10 to 0.80 in. w.g. Air Volume (cfm) THA072S 6 Ton Standard Efficiency (Down-Flow) External Static (in.w.g.) 0.10 RPM Field BHP 0.20 RPM 0.30 BHP RPM 0.40 BHP RPM 0.50 BHP RPM 0.60 BHP Furnished RPM Low 0.70 BHP Static RPM 0.80 BHP RPM BHP - Drive Kit #4 1900 775 0.45 820 0.50 870 0.55 915 0.65 965 0.70 1010 0.75 1060 0.85 1105 0.90 2000 810 0.55 855 0.60 900 0.65 945 0.70 990 0.75 1035 0.85 1080 0.90 1125 1.00 2100 850 0.60 890 0.65 935 0.75 975 0.80 1020 0.85 1060 0.95 1105 1.00 1145 1.10 2200 885 0.70 925 0.75 965 0.80 1005 0.90 1045 0.95 1090 1.05 1130 1.10 1170 1.20 2300 920 0.80 960 0.85 1000 0.90 1035 1.00 1075 1.05 1115 1.15 1155 1.20 1195 1.30 2400 960 0.90 995 0.95 1030 1.05 1070 1.10 1105 1.15 1145 1.25 1180 1.30 1220 1.40 2500 995 1.00 1030 1.10 1065 1.15 1100 1.20 1135 1.30 1175 1.35 1210 1.45 1245 1.50 2600 1035 1.15 1065 1.20 1100 1.25 1135 1.35 1170 1.40 1205 1.50 1240 1.60 1275 1.65 2700 1070 1.30 1100 1.35 1135 1.40 1170 1.50 1200 1.55 1235 1.65 1265 1.70 1300 1.80 2800 1105 1.40 1140 1.50 1170 1.55 1200 1.65 1235 1.70 1265 1.80 1295 1.85 1330 1.95 2900 1145 1.60 1175 1.65 1205 1.70 1235 1.80 1265 1.85 1295 1.95 1330 2.05 1360 2.10 Air Volume (cfm) THA072S 6 Ton Standard Efficiency (Down-Flow) 0.90 to 1.60 in. w.g. External Static (in.w.g.) 0.90 RPM Low BHP Static 1.00 RPM BHP - Kit #4 1.10 RPM BHP High Static 1.20 RPM BHP 1.30 1.40 1.50 1.60 RPM BHP RPM BHP RPM BHP RPM BHP - Drive Kit #8 1900 1150 1.00 1190 1.10 1235 1.20 1275 1.25 1315 1.35 1355 1.45 1395 1.55 1435 1.65 2000 1165 1.10 1210 1.15 1250 1.25 1290 1.35 1330 1.45 1370 1.55 1410 1.65 1445 1.75 2100 1190 1.15 1230 1.25 1270 1.35 1310 1.45 1350 1.55 1385 1.65 1425 1.75 1460 1.85 2200 1210 1.25 1250 1.35 1290 1.45 1325 1.55 1365 1.65 1400 1.75 1440 1.85 1475 1.95 2300 1235 1.40 1270 1.45 1310 1.55 1345 1.65 1385 1.75 1420 1.85 1455 1.95 1490 2.05 2400 1255 1.50 1295 1.60 1330 1.65 1365 1.75 1400 1.85 1440 2.00 1475 2.10 1505 2.20 2500 1280 1.60 1315 1.70 1355 1.80 1390 1.90 1425 2.00 1455 2.10 1490 2.20 1525 2.30 2600 1310 1.75 1340 1.85 1375 1.95 1410 2.05 1445 2.15 1480 2.25 1510 2.35 1545 2.45 2700 1335 1.90 1370 2.00 1400 2.10 1435 2.20 1465 2.30 1500 2.40 1530 2.50 1565 2.60 2800 1360 2.05 1395 2.15 1425 2.25 1460 2.35 1490 2.45 1520 2.55 1555 2.65 1585 2.80 2900 1390 2.20 1420 2.30 1450 2.40 1485 2.50 1515 2.60 1545 2.70 1575 2.85 1605 2.95 Page 21 TABLE BLOWER BELT DRIVE 6 Ton Standard Efficiency (Horizontal) 0.10 to 0.80 in. w.g. Air Volume (cfm) 0.10 RPM Field 0.20 BHP 12 PERFORMANCE RPM External Static (in.w.g.) 0.40 0.50 0.30 BHP RPM Furnished BHP Low Static RPM BHP THA072S 0.60 0.70 0.80 RPM BHP RPM BHP RPM BHP RPM BHP - Drive Kit #4 1900 905 0.60 955 0.65 1000 0.70 1045 0.75 1090 0.85 1135 0.90 1175 0.95 1215 1.05 2000 945 0.65 995 0.75 1040 0.80 1085 0.85 1125 0.95 1170 1.00 1210 1.05 1250 1.15 2100 990 0.75 1035 0.85 1080 0.90 1120 0.95 1160 1.05 1205 1.10 1240 1.20 1280 1.25 2200 1030 0.85 1075 0.95 1115 1.00 1160 1.10 1200 1.15 1235 1.25 1275 1.30 1310 1.40 2300 1075 1.00 1115 1.05 1155 1.15 1195 1.20 1235 1.30 1275 1.35 1310 1.45 1345 1.50 2400 1115 1.10 1155 1.20 1195 1.25 1235 1.35 1275 1.45 1310 1.50 1345 1.60 1380 1.70 2500 1160 1.25 1200 1.35 1235 1.40 1275 1.50 1310 1.60 1345 1.65 1380 1.75 1415 1.85 2600 1205 1.40 1240 1.50 1275 1.55 1315 1.65 1350 1.75 1385 1.85 1415 1.90 1450 2.00 2700 1245 1.55 1285 1.65 1320 1.75 1355 1.85 1390 1.95 1420 2.00 1455 2.10 1485 2.20 2800 1290 1.75 1325 1.85 1360 1.95 1395 2.00 1425 2.10 1460 2.20 1490 2.30 1520 2.40 2900 1335 1.95 1365 2.00 1400 2.10 1435 2.20 1465 2.30 1500 2.40 1530 2.50 1560 2.60 0.90 to 1.60 in. w.g. Air Volume 0.90 (cfm) RPM BHP High Static THA0728 6 Ton Standard Efficiency (Horizontal) External Static (in.w.g.) 1.00 I 1.10 RPM BHP I RPM - Drive Kit #8 1.20 1.30 1.40 1.50 1.60 BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1900 1255 1.10 1295 1.15 1335 1.25 1370 1.30 1405 1.40 1440 1.45 1475 1.55 1510 1.65 2000 1285 1.20 1325 1.30 1360 1.35 1395 1.45 1430 1.50 1465 1.60 1500 1.70 1530 1.75 2100 1315 1.35 1355 1.40 1390 1.50 1425 1.55 1460 1.65 1490 1.70 1525 1.80 1555 1.90 2200 1350 1.45 1385 1.55 1420 1.65 1455 1.70 1485 1.80 1520 1.85 1550 1.95 1585 2.05 2300 1380 1.60 1415 1.70 1450 1.75 1480 1.85 1515 1.95 1545 2.00 1580 2.10 1610 2.20 2400 1415 1.75 1450 1.85 1480 1.90 1515 2.00 1545 2.10 1575 2.20 1605 2.25 1635 2.35 2500 1450 1.95 1480 2.00 1515 2.10 1545 2.20 1575 2.25 1605 2.35 1635 2.45 1665 2.55 2600 1480 2.10 1515 2.20 1545 2.25 1575 2.35 1605 2.45 1635 2.55 1665 2.65 1695 2.75 2700 1520 2.30 1550 2.40 1580 2.45 1610 2.55 1640 2.65 1670 2.75 1695 2.85 1725 2.95 2800 1555 2.50 1585 2.60 1615 2.70 1645 2.80 1670 2.85 1700 2.95 1730 3.05 1760 3.20 2900 1590 2.70 1620 2.80 1650 2.90 1675 3.00 1705 3.10 1735 3.20 1760 3.30 1790 3.40 ADDITIONAL Air Volume cfm 8OO 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 TABLE 13 ACCESSORY AIR RESISTANCE Economizer Electric Heat 0.04 0.04 0.04 0.04 0.04 0.05 0.05 0.05 0.05 0.06 0.06 0.06 0.01 0.03 0.06 0.09 0.12 0.15 0.18 0.20 0.22 0.24 0.26 0.28 TABLE 14 MINIMUM AIRFLOW TH (BELT DRIVE) UNITS WITH ELECTRIC HEAT CFM Kw Downflow Horizontal 30 22,5 2250 1750 2050 1800 15 7,5 1250 1050 1350 1200 Direct drive units with electric heat (7.5-22.5kW) speed up to 0.6"w.g, maximum static pressure. Page 22 can operate on low TABLE 15 DRIVE KIT SPECIFICATIONS Motor hp Nominal Maximum 1.5 1.7 2 2.3 6731010 Drive 2 Drive 3 745-1117 833-1250 RPM Range Drive 4 Drive 5 968-1340 Drive 6 897-1346 1071-1429 Drive 7 Drive 8 12121548 1193-1591 *Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor hp required. Maximum usable hp of motors furnished by Lennox are shown. In Canada, nominal motor hp is also maximum usable motor hp. if motors of comparable hp are used, be sure to keep within the service factor bimitations outlined on the motor nameplate. B - Three Phase Scroll Compressor Three 1- Set thermostat or temperature control device to phase sequentially scroll compressors Voltage Phasing must be phased to ensure correct compressor and blower rotation and operation. Compressor and blower are wired initiate a first-stage heating demand. in phase at the factory. Power wires are color-coded as A first-stage heating demand (W1) will energize compressors 1 and the outdoor fan. Note - L1 reversing valve is de-energized in the heating mode. THA Units With Optional Electric Heat An increased heating demand (W2) will energize electric heat. Electric heat is also energized during the defrost cycle (W1) to maintain discharge air temperature. follows: line 1-red, line 2-yellow, line 3-blue. 1- Observe suction and discharge blower rotation on unit start-up. pressures and 2- Suction pressure must drop, discharge pressure must rise, and blower rotation must match rotation marking. If pressure differential is not observed or blower rotation is not correct: 3- Disconnect all remote electrical power supplies. 4- Reverse any two field-installed wires connected to the line side d K1 contactor. Do not reverse wires at blower contactor. Make sure the connections are tight. ,&,IMPORTANT Discharge and suction pressures should operate at their normal start-up ranges. C - Refrigerant Charge and Check WARNING-Do not exceed nameplate charge under any condition. This unit is factory charged and should require no further A - Start-Up 1- Set thermostat or temperature control device fan switch to AUTO or ON. Set thermostat or temperature control device to initiate a first-stage cooling demand. A first-stage Y1 cooling demand will energize reversing valve solenoid and compressor 1, L1 Units With Optional Economizer The optional economizer will start on a first stage (Y1) cooling demand when outdoor air enthalpy is suitable, An increased cooling demand (Y2) will energize compressor 1, 2- Refrigerant circuits are factory charged with HCFC-22 refrigerant. See unit rating plate for correct amount of charge. adjustment. If the system requires charge, reclaim the charge, evacuate the system, and add required nameplate charge. NOTE - System charging is not recommended below 60'_F (15_C). In temperatures below 60'_F (15_C) , the charge must be weighed into the system. If weighing facilities are not available, or to check the charge, use the following procedure: 1- Attach gauge manifolds and operate unit in cooling mode until system stabilizes (approximately five minutes). 2- Check each operating. system separately with all stages 3- Use a thermometer to accurately outdoor ambient temperature. measure the 4- Apply the outdoor temperature to tables 18 through 24 to determine normal operating pressures. Page 23 5- Comparethe normaloperatingpressuresto the pressures obtained from the gauges, Minor variationsinthesepressures maybeexpected dueto differencesin installations.Significantdifferences couldmeanthatthesystemis notproperlycharged or thata problemexistswithsomecomponent inthe system,Correct any system problems before proceeding. TABLE 16 TH 024S NORMAL OPERATING PRESSURES Outdoor Coil Entering Air Temp 65°F Dis. +10 psig Suct. +5 psig 141 82 163 84 85 oF 189 85 95°F 219 86 105°F 252 87 115°F 289 89 75 oF TABLE 17 TH 030S NORMAL OPERATING Outdoor Coil Entering Air Temp 65°F TABLE 20 TH 048B NORMAL OPERATING PRESSURES Outdoor Coil Entering Air Temp 65 ° F Dis. + 10 psig Suct. +5 psig 185 76 75 ° F 212 78 85 ° F 242 80 95 o F 276 81 105 o F 312 82 115 ° F 351 84 TH 048S NORMAL Outdoor Coil Entering Air Temp 65 ° F TABLE 21 OPERATING PRESSURES Dis. + 10 psig Suct. +5 psig 171 86 75 ° F 85 ° F 95 ° F 197 227 259 86 88 89 105 ° F 295 90 115 ° F 335 91 PRESSURES TABLE 22 TH 060B NORMAL OPERATING Outdoor Coil Entering Air Dis. + 10 psig Temp PRESSURES Dis. +10 psig Suct. +5 psig 146 81 75 oF 167 82 65 o F 174 68 85 oF 194 84 75 o F 201 71 95°F 227 85 85 o F 232 73 105°F 261 87 95 ° F 267 77 115°F 298 89 105 o F 305 80 115 o F 346 84 TABLE 18 TH 036B NORMAL OPERATING Outdoor Coil Entering Air Temp 65°F PRESSURES Dis. +10 psig Suct. +5 psig 169 81 75 oF 196 82 85°F 226 84 95°F 259 85 105°F 296 86 115°F 336 87 TABLE 19 TH 036S NORMAL OPERATING TABLE 23 TH 060S NORMAL OPERATING Outdoor Coil Entering Air Dis. + 10 psig Temp 65 ° F 163 75 ° F 189 PRESSURES Suct. +5 psig 81 82 85 ° F 95 ° F 217 259 84 85 105 ° F 285 86 115 ° F 323 88 TABLE 24 TH 072S NORMAL OPERATING Outdoor Coil Entering Air Dis. + 10 psig Temp PRESSURES Suct. +5 psig PRESSURES Outdoor Coil Entering Air Temp Dis. +10 psig Suct. +5 psig 65 o F 154 83 65 ° F 173 70 75 o F 178 83 75 ° F 203 76 85 ° F 2O5 84 85 ° F 234 81 Suct. +5 psig 95 ° F 236 86 95 ° F 267 84 105 o F 269 88 105 ° F 304 86 115 ° F 306 89 115 ° F 343 87 Page 24 6- If discharge pressure is high, remove refrigerant from the system, If discharge pressure is low, add refrigerant to the system. • Add or remove charge in increments. • Allow the system to stabilize each refrigerant is added or removed. E - Compressor Controls See unit wiring diagram to determine which controls are used in each unit, Optional controls are identified on wiring diagrams by arrows at junction points. time - 7- Use the following approach method along with the normal operating pressures to confirm readings. D - Charge Verification - Approach Method 8-Using the same thermometer, compare temperature to outdoor ambient temperature, Approach Temperature ambient temperature, = Liquid temperature freeze-up, Switch resets when temperature reaches 58 _F (15<_C). liquid minus . 9- Approach temperature should match values in table 25. An approach temperature greater than value shown indicates an undercharge. An approach temperature less than value shown indicates an overcharge, 10- Do not use the approach method if system pressures do not match pressures in tables 18 through 24, The approach method is not valid for grossly over or undercharged systems. TABLE 25 APPROACH TEMPERATURE Unit Liquid Temp. Minus Ambient Temp. 024S 7°F + 1 (3.9°C + 0.5) 030S 8°F + 1 (4.4°C + 0.5) 036B 8°F + 1 (4.4°C + 0.5) 036S 7°F + 1 (3.9°C + 0.5) 048B 16°F+ 1 (8.9°C + 0.5) 048S 10°F+ 1 (5.6°C + 0.5) 060B 12°F+ 1 (6.7°C + 0.5) 060S 6°F + 1 (3.3°C + 0.5) 072S 11°F+ 1 (6.1°C +0.5) Freezestat (S49) Switch de-energizes compressor when indoor coil temperature falls below 29_F (-2<_C)to prevent coil indoor coil Defrost Switch ($6) Defrost switch closes to initiate defrost when liquid line temperature falls to 42°F (5.6°C), Defrost switch opens when liquid line temperature reaches 70°F (21°C) to terminate defrost. If the liquid line temperature does not rise above 70°F (21°C), the CMC1 will terminate defrost after 14 minutes. The defrost switch is located on the liquid line between the outdoor expansion valve and the distributor _ Defrost Control (CMC1) Defrost is liquid line temperature initiated and operates for 14 minutes unless terminated by liquid line temperature. When the liquid line temperature drops below 42°F (5.6°C), the defrost switch closes and signals the defrost control that a defrost cycle is needed, If the defrost switch is still closed after 60 minutes (default), a defrost cycle begins and operates for 14 minutes. The defrost switch can terminate the defrost cycle before the 14 minutes elapses temperature reaches 70°F (21°C) if liquid line Electric heat is energized during defrost to maintain discharge air temperature. Page 25 The defrostthermostatand the defrostcontrolwork togethertoensurethattheheatpumpoutdoorcoildoes noticeexcessively duringtheheatingmode. Compressor Accumulated Run-Time Interval The defrost control will not energize a defrost cycle unless the unit has been operating in heating mode for an accumulated 60 minutes (default). The run time interval can be changed by moving the jumper on the CMC board timing pins. See figure 18. DEFROST CONTROLBOARD P} TIMING JUMPER ©" I_s/ \/' Anti-short cycle lockout REtAY DIAGNOSTIC LEDS ___ 0 Ds2 TEST P5 / J K2 RELAY _i-[I Alternating Slow FLASH Low pressure switch, OFF freezestat fault Slow FLASH Low pressure switch, OFF freezestat lockout ON High pressure switch Slow FLASH fault OFF High pressure switch ON lockout P2 REMOVEFOR COMPRESSOR DELAY PS The OFF OFF Simultaneous Slow FLASH ................................................. 0 OUT I0 The defrost board uses two LEDs for diagnostics. LEDs flash a sequence according to the condition. TABLE 26 No power to control Normal operation / power to control FA KI Diagnostic LEDs Defrost Control Board Diagnostic LED Green LED Mode (DS2) Red LED (DS1) CMC1 @ removed before an additional 5-second period has elapsed (7 seconds total), the unit will remain in defrost mode until the defrost pressure switch opens or 14 minutes have passed. If the jumper is not removed until after the additional 5-second period has elapsed, the defrost will terminate and the test option will not function again until the jumper is removed and re-applied. OFF C The unit should be inspected once a year by a qualified service technician. 24V .......... ,WARNING FIGURE 18 The defrost interval can be adjusted to 30, 60, or 90 minutes. The defrost timing jumper is factory-installed to provide a 60-minute defrost interval. If the timing selector jumper is not in place, the control defaults to a 90-minute defrost interval. ,CAUTION Defrost Test Option A TEST option is provided for troubleshooting. The TEST mode may be started any time the unit is in the heating mode and the defrost thermostat is closed or jumpered. If the timing jumper is in the TEST position at power-up, the defrost control will ignore the test pins. When the jumper is placed across the TEST pins for two seconds, the control will enter the defrost mode. If the jumper is A - Lubrication All motors are lubricated lubrication is required, Page 26 at the factory. No further B - Filters E - Outdoor Coil Units are equipped with temporary flters which need to be replaced before the building is occupied. See table 27 for correct filter size. Refer to local codes or appropriate jurisdiction for approved filters. Clean outdoor coil annually with detergent or commercial coil cleaner and inspect monthly during the cooling season. Approved filters should be checked monthly and replaced when necessary. Take note of air flow direction marking on filter frame when reinstalling filters. See figure 19. &WARNING Outdoor coils are made of single and two formed slabs. On units with two slabs, dirt and debris may become trapped between the slabs. To clean between slabs, carefully separate coil slabs and wash them thoroughly. See figure 20. Flush coils with water following cleaning. Note - Remove all screws and gaskets prior to cleaning procedure and replace upon completion. F - Filter Drier The unit is equipped with a biflow filter drier, if replacement is necessary, order another of like design. TABLE 27 UNIT FILTERS Qt Unit Y Filter Size - inches REMOVE FILTERS (mm) 024, 030, 036, 048,060B 4 16 X 20 X 2 (406 X 508 X 51) 060S, 072 4 20 X 20 X 2(508 X 508 X 51) NOTE-Filtersmust usein Canada. be U.L.C. certified or equivalent _r PULL TO REMOVE FILTERS C - Supply Air Blower Wheel Annually inspect supply air blower wheel for accumulated dirt or dust. Turn off power before attempting to remove access panel or to clean blower wheel. D - Indoor Coil Inspect and clean coil at beginning of each cooling and heating season. Clean using mild detergent or commercial coil cleanser. Flush coil and condensate FIGURE 19 drain with water taking care not to get insulation, filters and return air ducts wet. CLEAN OUTDOOR COIL TOP VIEW ENDPLATE IS SECURED TO MULLION 12- Remove screws securing coil end plate to mullion. Remove clips connecting coils slabs and separate slabs 3-4" (76-102mm). 0_ 3- Clean coils with detergent or commercial coil cleaner. 4- Rinse thoroughly with water and reassemble. OUTDOOR COILS FIGURE 20 Page 27
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 28 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Wed Jul 02 04:13:44 2008 Author : Title : Subject :EXIF Metadata provided by EXIF.tools