GAS KITS AND ACCESSORIES
© 2007 Lennox Industries Inc.
Dallas, Texas, USA

IGNITION CONTROL
REPLACEMENT
KIT

505,313M

0912007
INSTALLATION

INSTRUCTIONS

FOR IGNITION

CONTROL

REPLACEMENT

KIT 30W33

(LB-90701C), USED TO REPLACE A ROBERTSHAW
735L (18G91) OR 745 (97H04) IGNITION
CONTROL, OR A JOHNSON
G776 (63K2401, 41K8701 or 69J3601)
IGNITION
CONTROL
pointing toward the left, so that the widng
connections can be made. Use two #8 - 16 X 1/2"
screws (provided) to secure the ignition control to the
control bracket. See figure 4 for the correct mounting
holes t_ use.

Package 1 of I contains:
I - Replacement ignition control (Honeywell)
2 - Wire nuts
4 - #8- 16 x 1/2" screws

6 - Install the provided flame sensor on the existing pilot
assembly.

4- Wires
1 - Flame sensor

7-

1 - Insulated 1/4 inch quick connect
1 - Control bracket

Rout_ the white sensor wire (provided) from the
flame sensor to the ignition control. Keep this wire
away from other wire routing.

8- See figure 1 for the replacement ignition control
wiring.

1 - Widng diagram
1 - Diagnostic code label

Check equipment for shipping damage. If you find any
damage, immediately contact the last carder.

Use ignition control replacement kit 30W33 (LB-90701C)
with G20, G20R, G23, and G26 units that have a
Robertshaw 735L (18G91) or 745 (97H04) ignition
control or a Johnson G776 ignition control (63K2401,
41K8701 or 69J3601). This replacement kit includes a
Honeywell IPI ignition control.

Replacing a Robertshaw Ignition Control
(G20/G20R)
1 - Disconnect electrical power and gas supply to the
unit.

a-

Connect the whit_esensor wire to ignition control
terminal 8-SENSE.

b-

Reconnect the wire from the blocked vent
switch to ignition control terminal 6-24V.

C-

Reconnect the yellow wire ffom pin position 7 on
jack/plug J20/P20 to ignition control terminal
5-24V (GND).
NOTE - J20/P20 not used on G20R units.

d-

Reconnect the gas valve P/Mterminal blue wire
to ignition control terminal 2-MV/PV.

e-

Reconnect the gas valve terminal M red wire to
the ignition control terminal 1-MV.

f-

Reconnect the gas valve terminal P orange wire
to the ignition control terminal 3-PV.

g-

Reconnect the 1/4 inch quick-connect orange
ignition cable to the ignitionterminal 9-SPARK.

h-

Connect the provided green ground wire to the
ignition control terminal 4-GND (Bumer).
Connect the opposite end of the green ground
wire to the unit ground screw.

i-

Route wires to the right side of the manifold and
use wire tie to bundle them.

2 - Remove the unit access panel.
3-

Mark and disconnect the wires from the existing
ignition control.

4 - Remove the ignition control from the metal stand-off
bracket. Discard the ignition control; but, keep the
stand-off bracket.
5 - Use two provided #8 - 16 X 1/2" screws to secure the
provided control bracket to the existing stand-off
bracket. Positionthe replacement ignition controlon
the right side of the vestibule panel with the t_rminal

9 -Affix the provided wiring diagram sticker adjacent to
the existing unit widng diagram. Affix the diagnostic
code label so that it will be easily seen.
10 - Replace the access panel, and follow the start-up
and adjustment section.

Page 1

TYPICAL

DIAGRAM

G20/G20R

UNITS WITH

EXISTING

Robertshaw Ignition Control Wiring

ROBERTSHAW

CONTROL

Honeywell Ignition Control Wiring

A5
1
THIS UNIT HAS BEEN
I
CONVERTED TO A HONEYWELL
ISNITIDN _NTROL

GNO

1

s,o _
MV/RV

[]


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 4
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 4, 0, 0, 13
Create Date                     : Sun Jul 20 21:07:28 2008
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu