INSTALLATION

INSTRUCTIONS

Litho USA

HEAT EXCHANGER

05/99
Supersedes 01/97

TechnICal
I Publications

FOR HEAT EXCHANGER

REPLACEMENT

REPLACEMENT

KITS

KITS

TABLE 1

kWARNING

HEAT EXCHANGER

HEAT
EXCHANGERK_
FinalAssemblyNo,

80MGF/G24M
Model No. Size Design_ion.

38K92

LB-79824A

2-45A

38K93

LB-79824B

2-45S

38K94

LB-79824C

2-60A

38K95

LB-79824D

2-60S

36K61

LB-79824G

3-60A

36K62

LB-79824H

3-60S

"38K96

LB-79824E

2-75A

"38K97

LB-79824F

2-75S

"36K63

LB-79824J

3-75A

"36K64

LB-79824K

3-75S

"36K65

LB-79824L

4-75A

"36K66

LB-79824M

4-75S

Package 1 of 1 contains:
1 - Heat exchanger assembly, including:
1 - flue box assembly
1 - pressure switch
1 - limit control
I - Plastic bag
1 - Conversion sticker
2- Wire nuts

KIT APPLICATION

HEAT
EXCHANGERK_
Catalog No.

*Note -In 2-75, 3-75, and 4-75 heat exchanger replace-

2 - Wire ties (one of the screw-securing type, one plain)
1 - 4 in flue adapter for the 75 model size only
I - Installation instructions

ment applications

-

a - single appliance
The entire

venting

venting applications

inches in diameter. If the existing
Check all components for shipping damage. If any damage is found, immediately contact the last carrier.

b - multiple appliance
The vent connector,

These kits are for use with the dash 1 and dash 2 versions of the 80MGF and G24M-45/60/75 series gas furnaces. In these units, they replace the existing heat exchanger with the current production heat exchanger,
thereby preventing nuisance flashback (burnback) in the
burners, as well as sooting of the heat exchanger. Refer
to table 1 for heat exchanger kit application.

venting system is 3

inches in diameter, it must be converted
in diameter.

heat exchanger

-

system must be no less than 4

venting applications

to 4 inches

-

for the furnace undergoing this

replacement,

must be no less than 4

inches in diameter. If the existing vent connector is 3
inches in diameter, it must be converted to 4 inches
in diameter.
Failure

to adhere to these requirements,

Io wflue gases to enterthe
injury

Page 1

or death.

living

could

al-

space, resulting

in

1- Beforebeginning
theinstallation,
verifythatthemodel
numbersizedesignation
indicated
onthereplacement
heatexchanger's
I.D.Iabelmatches
thatofthemodel
numbersizedesignation
indicated
ontheunifsrating
plate.Seetable1.
2- Setthethermostat
to itslowestsetting.
3- Turn off all electrical power to the furnace.
4-

21 - In 2-75, 3-75, and 4-75 heat exchanger replacement
applications a - single appliance venting applications The entire venting system must be no less than
4 inches in diameter. If the existing venting system is 3 inches in diameter, convert it to 4 inches
in diameter.
b - multiple appliance venting applications The vent connector, for the furnace undergoing
this heat exchanger replacement, must be no
less than 4 inches in diameter. If the existing
vent connector is 3 inches in diameter, convert
it to 4 inches in diameter.

Turn off the gas at the equipment main manual
shut-off valve.

5 - Remove the fumace access panel.

Note - Failure to adhere to the requirements, in
section a or b above, could allow flue gases to enter the living space, resulting in injury or death.
Install the kit-provided 4 in. flue adapter to the outlet of
the induced blower. Then connect the flue adapter
to the 4 in. vent connector.

6 - Close the fumace gas valve.
7- Disconnect the supply gas line at the furnace gas
valve.
8 - Disconnect the wire harness and the ignition lead
from the ignition control.
9 - Disconnect the flue adapter with attached vent connector from the induced draft blower.
10 -Remove the heat exchanger assembly, with flue
box and burner box assemblies, from the unit.
11 - On the existing heat exchanger, cut the screw-secured
wire tie attached to the burner box top.
12 -Cut the induced draft blower leads between the
plug and the inducer leaving approximately
es (150mm) attached to the plug.

9 inch-

22 - In 2-45, 2-60, and 3-60 heat exchanger replacement
applications Reconnect the existing flue adapterwith vent connector to the outlet of the induced blower.
23 - Affix the conversion sticker adjacent to the rating
plate.
24 - Reconnect the gas supply line to the gas valve.
25 - Turn on the main manual gas shut-off valve.
Carefully check all gas piping connections for leaks.

13 - Labeland then disconnect alIwiring from the burner box to the limit control and pressure switch.
14 - Remove the burner box assembly from the existing heat exchanger and then install it in the replacement heat exchanger. Discard the existing
heat exchanger or return it to Lennox for a warranty claim.

IMPORTANT

15 -On the replacement heat exchanger, using the
screw-securing
type of wire tie (kit-provided),
in
the original wire bundling location, bundle up all of
the Ioosewires, including the induced draft blower
leads. Do not secure the wire tie to the burner box
top at this time.

ILCAUTION

16 - Reconnect the limit control wires and the pressure
switch wires.
17 - Install the replacement heat exchanger in the cabinet.
18 - Splicethe induced draft blower leads using the kitprovided wire nuts.
19 - Reconnect the wire harness and the ignition lead.
20 -Check the final wire routing, and then fasten the
screw-securing
type of wire tie to the burner box
top, and bundle the remaining wires with the kitprovided wire tie (plain-type).

26 -Start the furnace by following the procedures as
indicated in the "Unit Start-Up" section of the
installation instructionsprovidedwiththefurnace.
27 - Monitor unit operation, both start-up operation and at
least 15 minutes of running operation. Repeat this test
two more times. When the test is successful, set the
thermostat to its normal heat setting.

Page 2



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 2
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 4, 0, 0, 13
Create Date                     : Sun Jul 20 21:09:04 2008
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu