LINAK A S HBGL Remote Control User Manual

LINAK A/S Remote Control

user manual

                                  FLAT BUTTON Press and hold to lower the base to flat position.  This will also turn off massage motors LOCK BUTTON Press and hold for 3 seconds to lock or unlock remote. Backlight will flash 3 times confirming the change. HEAD UP/DOWN BUTTONS Press and hold to adjust the head section   FOOT UP/DOWN BUTTONS Press and hold to adjust the foot section   UNDERBED LIGHT BUTTON Press and release to toggle underbed light SET BUTTON Simultaneously press and hold this button AND “MEM1” or “MEM2” or “SNORE” or “ZGRAV” to program a new memory position.  The massage motors will chirp once to confirm a new position has been set. SNORE BUTTON Press and hold to adjust the head section of your partner’s side to a 15° angle.  This will go down to flat after 15 minutes ZERO GRAVITY BUTTON Press and hold to adjust the base to the “Zero Gravity” position. Massage setting can also be saved in this position. MEM 1 / MEM 2 BUTTONS Press and hold to adjust the base to the programmed position.  Massage settings can also be saved in these positions. WAVE BUTTON Press and release to turn on the massage motors in wave mode.  If already in wave mode, the massage motors will go back to constant mode. HEAD MASSAGE UP/DOWN BUTTONS Press and release adjust the intensity of the head massage motor up or down.  There are 3 levels: low, medium, and high.  Pushing the DOWN button when in low level will turn the massage off.  Massage will automatically shut off after 30 minutes.   FOOT MASSAGE UP/DOWN BUTTONS Press and release adjust the intensity of the foot massage motor up or down.  There are 3 levels: low, medium, and high.  Pushing the DOWN button when in low level will turn the massage off.  Massage will automatically shut off after 30 minutes.   PRESS & HOLD TO ONE TOUCH. To change the remote from “press & hold” mode to “one touch” mode, simultaneously press the FLAT and HEADUP buttons for 3 seconds.   The massage motors will chirp once to confirm the change.   Use the same process to switch from “one touch” mode back to “press & hold” mode.   When in “one touch” mode: - Press & release Mem 1, Mem 2, or Z-GRAVand the base will automatically adjust to the programmed memory position (including massage settings).  Press any other button to stop the base during movement.   - Press & release FLAT and the base will turn off massage motors and automatically adjust the base to the flat position.  Press any other button to stop the base during movement.   To revert back to factory settings, simultaneously press and hold the FLAT and HEADDOWN buttons for 3 seconds.  The massage motors will chirp confirming the change and your base is now back to factory settings.   SCAPE + REMOTE CONTROL FUNCTIONALITY HBGL-U001-XX Gladiator remote
 FCC ID: XBE-HBGL IC: 12338B-HBGL This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Changes or modifications to this unit not expressly approved by the party responsible forcompliance could void the user's authority to operate the equipment. Statement for digital devices for class B: NOTE: This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protectionagainst harmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, may causeharmful interference to radio communications. However, there is no guarantee that interference will notoccur in a particular installation. If this equipment does cause harmful interference to radio or televisionreception, which can be determined by turning the equipment off and on, the user is encouraged to try tocorrect the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiverisconnected. —Consult the dealer or an experienced radio/TV technician for help.  This device complies with Industry Canada license-exempt RSS standard(s).  Operation issubject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Navigation menu