Landis+Gyr Confidential Information 98-9112 Rev AA 3High Speed FOCUS AX Modular Gridstream RF Endpoint Data SheetGeneralThe FOCUS AX Modular Gridstream RF endpoint is designed to accommodate Landis+Gyr FOCUS AX meters for use in residential and light industrial services. The FOCUS AX Advanced Function meter is an Active Energy kWh/kW/TOU Meter. The meter features Digital Multiplication Measurement Technique, meets ANSI standards for performance and utilizes ANSI C12.19 protocol (between meter and AMR device).Figure 1 - 1. The FOCUS AX Modular Gridstream RF Endpoint Module andthe Landis+Gyr FOCUS AX MeterFCC Compliance InformationModel: FASY-0864FCCID: TEB-HUNTSU864IC: 5931A-HUNTSU864500158E2Hunt TechnologiesModel 0864CONTAINS FCC ID: TEB-HUNTSU864 CONTAINS IC: 5931A-HUNTSU864RF GRIDSTREAM
High Speed FOCUS AX Modular Gridstream RF Endpoint Data Sheet Landis+Gyr4 98-9112 Rev AA Landis+Gyr Confidential InformationCompliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:1. This device may not cause harmful interference, and2. This device must accept any interference received, including interference that may cause undesired operation.$Changes or modifications not expressly approved by Landis+Gyr for compliance could void the user’s authority to operate the equipment.Endpoint LocationTo comply with FCC’s RF exposure limits for general population/uncontrolled exposure, the antenna(e) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.Endpoint UsageThe FOCUS AX Modular Gridstream RF endpoint will be used:• for residential and commercial metering applications.• at homes and businesses.The FOCUS AX Modular Gridstream RF endpoint requires professional installation by qualified personnel.RF InterferenceThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the meter off, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Consult Landis+Gyr or an experienced radio/TC technician for help.Required SoftwareTo work with the endpoint, you need one of the following software tools:
Landis+Gyr High Speed FOCUS AX Modular Gridstream RF Endpoint Data SheetLandis+Gyr Confidential Information 98-9112 Rev AA 5• Command Center 4.1 or greater.• RadioShop.• Network Configuration Manager.• Landis+Gyr 1132Prog application.• Endpoint Testing Manager.• Endpoint Implementation Manager.SpecificationsTable 1-1. FOCUS AX Modular Gridstream RF Endpoint SpecificationsCategory Specification Value or RangeCompatible MetersLandis+Gyr FOCUS AX Supported Meter FormsFOCUS AX FOCUS AX-SDForm Class Form Class1S 100 1S 1002S 200 2S 2002SE 320 12S 2002K 480 25S 2003S 120V 10/203S 240V 10/204S 10/2012S/25 20012SE/25 32016S 20016SE 32036(6)S 209(8)S 2045S 20Electrical Voltage 9-16V (from meter’s power supply)Power Max: 1.0WTypical: 0.6WRF 900 MHz Output Power +26 dBm +/-1 dBmAdjacent Channel Power 39 dBc NominalTransmit Frequency 902 to 928 MHz ISM unlicensed (FCC Part 15)Communication Protocol Grid Stream Protocol for Command CenterReceive Sensitivity  -108 dBm Nominal
High Speed FOCUS AX Modular Gridstream RF Endpoint Data Sheet Landis+Gyr6 98-9112 Rev AA Landis+Gyr Confidential InformationRF ZigBee Output Power +20 dBm +/-Adjacent Channel Power 40 dBc NominalTransmit Frequency 2405-2480 MHzCommunication Protocol ZigBee ProtocolReceive Sensitivity  -104 dBm MinimumStandards ComplianceFCC Title 47 CFR Part 15 Radiated and Conducted Emissions (incl. intentional radiators)IEC 61000 4-2,3,4,5,11,12 Electromagnetic CompatibilityANSI C12.19 Compatible with Utility Industry End Device TablesANSI C12.20 National Standard for Electricity Meters - 0.2 and 0.5 Accuracy ClassesANSI C12.21 Code for Electricity Metering ANSI C37.90.1 (1989) Standard Surge Withstand Capability (SWC) TestsEnvironmentalGeneral Environmental Outdoor, rain-protected, sunlight-exposedOperating Temperature Range -40 to +70 C (under meter glass)Humidity 0 to 95% relative humidity, non-condensingMechanical Size 3.242 L x 5.315 W x .094 inches, typicalWeight 2.0 ounces (56.7 g), typicalTable 1-1. FOCUS AX Modular Gridstream RF Endpoint SpecificationsCategory Specification Value or Range

Navigation menu