Landis Gyr Technology EG1R1S1 Gridstream Focus AX Integrated User Manual FCC Part 15
Landis+Gyr Technology, Inc. Gridstream Focus AX Integrated FCC Part 15
Manual
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
Certification Exhibit
FCC ID: R7PEG1R1S1
FCC Rule Part: 15.247
ACS Report Number: 09-0075-15C
Manufacturer: Cellnet Technology, Inc.
Model: Gridstream Focus AX Integrated
Manual
GridstreamRFE350FOCUSAX PUBS‐0788‐0001RevA
Gridstream RF E350
FOCUS AX Data Sheet
General
TheGridstreamRFE350FOCUSAXmoduleisanintegratedsolutionwithFOCUS
AXadvancedmeteringelectronicstheGridstreamAMRcommunication
electronicscombinedtogetheronasinglePCB.Itusesfield‐provenDigital
MultiplicationMeasurementTechniquetoensureahighlyaccurateload
performanceanddependabilityduringtheentirelifeoftheproduct.Italso
offersaServiceDisconnectoptionandZigBeeconnectivityforHANapplications
Figure1:Landis+GyrFOCUSAXmeterandtheGridstreamRFE350FOCUSAXmodule
GridstreamRFE350FOCUSAX PUBS‐0788‐0001RevA
FCC Compliance Information
Model:40‐6203(Forms2S,2SSD,2SE,3S,4S),40‐1234(Forms1S,1SSD)
FCCID:R7PEG1R1S1
IC:5294A‐EG1R1S1
Compliance Statement (Part 15.19)
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothe
followingtwoconditions:
1.Thisdevicemaynotcauseharmfulinterference,and
2.Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmay
causeundesiredoperation
Endpoint Location
TocomplywithFCC’sRFexposurelimitsforgeneralpopulation/uncontrolled
exposure,theantenna(e)usedforthistransmittermustbeinstalledtoprovide
aseparationdistanceofatleast20cmfromallpersonsandmustnotbe
collocatedoroperatinginconjunctionwithanyotherantennaortransmitter.
Endpoint Usage
TheGridstreamRFE350FOCUSAXwillbeused:
•Forresidentialandcommercialmeteringapplications
•Athomesandbusinesses
TheGridstreamRFE350FOCUSAXrequiresprofessionalinstallationbyqualified
personnel.
RF Interference
ThisproducthasbeentestedandfoundtocomplywiththelimitsforaClassB
digitaldevice,pursuanttopart15oftheFCCRules.Theselimitsaredesignedto
providereasonableprotectionagainstharmfulradiofrequencyenergyand,if
GridstreamRFE350FOCUSAX PUBS‐0788‐0001RevA
notinstalledandusedinaccordancewiththeinstructions,maycauseharmful
interferencetoradiocommunications.However,thereisnoguaranteethat
interferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoes
causeharmfulinterferencetoradioortelevisionreception,whichcanbe
determinedbyturningthemeteroff,theuserisencouragedtotrytocorrect
theinterferencebyoneormoreofthefollowingmeasures:
•Re‐orientorrelocatethereceivingantenna
•Increasetheseparationbetweentheequipmentandreceiver
•ConsultLandis+Gyroranexperiencedradio/TCtechnicianforhelp
ChangesormodificationsnotexpresslyapprovedbyLandis+Gyrfor
compliancecouldvoidtheuser’sauthoritytooperatetheequipment
Specifications
Table1:MeterCompatibility
S‐BaseMeterForms Voltage Units Comments
1SCL100
2SCL200
2SECL320
3SCL20
3SCL20
4SCL20
120
240
240
120
240
240
Vac
Vac
Vac
Vac
Vac
Vac
Only1Sand2Sare
availablewithService
Disconnect
Table2:GridstreamRadioGeneral
Parameter
Value Units Comments
Min Typ Max
RFFrequencyRange902.1 927.9 MHz
RFBaudRate9.6 19.2 kbps Programmable
Outputpower25.25 26.25 27.25 dBm Overtemperaturerange,
<2:1VSWRload
ReceiveSensitivity
‐112 ‐111 ‐108 dBm At10%PER,dependson
baudrate
AntennaTypeInvertedFPrinted
AntennaGain+5 dBi Peakgain
GridstreamRFE350FOCUSAX PUBS‐0788‐0001RevA
Table3:ZigBeeRadioGeneral
Parameter
Value Units Comments
Min Typ Max
RFFrequencyRange2.400 2.485 GHz
RFBaudRate250 kbps
Outputpower18 20 21 dBm <2:1VSWRload,Approx.
+2dBmoutputpoweron
channel26(2.485GHz)
ReceiveSensitivity‐106 ‐104.5 ‐102 dBm At1%PER
AntennaTypeInvertedFPrinted
AntennaGain+5 dBi Peakgain
Table4:Standards/Compliance
Standards/compliance
FCCTitle47CFRPart15RadiatedandConductedEmissions(incl.intentionalradiators)
IEC610004‐2,3,4,5,6,8,9,11ElectromagneticCompatibility
ANSIC12.20NationalStandardforElectricityMeters‐ 0.2and0.5Accuracy
Classes
ANSIC12.1CodeforElectricityMetering
ANSIC37.90.1(1989)StandardSurgeWithstandCapability(SWC)Tests
Table5:Mechanical
Parameter units
Size 5.5Lx5.0Wx1.5HInches
weight 48.2 g
Table6:Environmental
ParameterMin Max Units Notes
StorageTemperature ‐40 85
°
C
OperatingTemperature ‐40 85
°
C
RelativeHumidity 585 %Non‐condensing
Contact Information
Technical Support: 1-888-390-5733
Internet: www.landisgyr.com
Fax1-218-562-5530
E-mail:solutionsupport.na@landisgyr.com