Landis Gyr Technology EG1R1S1 Gridstream Focus AX Integrated User Manual FCC Part 15
Landis+Gyr Technology, Inc. Gridstream Focus AX Integrated FCC Part 15
Manual
Certification Exhibit FCC ID: R7PEG1R1S1 FCC Rule Part: 15.247 ACS Report Number: 09-0075-15C Manufacturer: Cellnet Technology, Inc. Model: Gridstream Focus AX Integrated Manual 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Gridstream RF E350 FOCUS AX Data Sheet General The Gridstream RF E350 FOCUS AX module is an integrated solution with FOCUS AX advanced metering electronics the Gridstream AMR communication electronics combined together on a single PCB. It uses field‐proven Digital Multiplication Measurement Technique to ensure a highly accurate load performance and dependability during the entire life of the product. It also offers a Service Disconnect option and ZigBee connectivity for HAN applications Figure 1: Landis+Gyr FOCUS AX meter and the Gridstream RF E350 FOCUS AX module Gridstream RF E350 FOCUS AX PUBS‐0788‐0001 Rev A FCC Compliance Information Model: 40‐6203 (Forms 2S, 2S SD, 2SE, 3S, 4S), 40‐1234 (Forms 1S, 1S SD) FCC ID: R7PEG1R1S1 IC: 5294A‐EG1R1S1 Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation Endpoint Location To comply with FCC’s RF exposure limits for general population/uncontrolled exposure, the antenna(e) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Endpoint Usage The Gridstream RF E350 FOCUS AX will be used: • For residential and commercial metering applications • At homes and businesses The Gridstream RF E350 FOCUS AX requires professional installation by qualified personnel. RF Interference This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful radio frequency energy and, if Gridstream RF E350 FOCUS AX PUBS‐0788‐0001 Rev A not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the meter off, the user is encouraged to try to correct the interference by one or more of the following measures: • Re‐orient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Consult Landis+Gyr or an experienced radio/TC technician for help Changes or modifications not expressly approved by Landis+Gyr for compliance could void the user’s authority to operate the equipment Specifications Table 1: Meter Compatibility S‐Base Meter Forms 1S CL100 2S CL200 2SE CL320 3S CL20 3S CL20 4S CL20 Voltage 120 240 240 120 240 240 Units Vac Vac Vac Vac Vac Vac Comments Only 1S and 2S are available with Service Disconnect Table 2: Gridstream Radio General Parameter RF Frequency Range RF Baud Rate Output power Value Min 902.1 9.6 25.25 Receive Sensitivity ‐112 Antenna Type Antenna Gain Gridstream RF E350 FOCUS AX Units Typ 26.25 Max 927.9 19.2 27.25 MHz kbps dBm ‐111 ‐108 dBm Inverted F +5 PUBS‐0788‐0001 Rev A dBi Comments Programmable Over temperature range, <2:1 VSWR load At 10% PER , depends on baud rate Printed Peak gain Table 3: ZigBee Radio General Parameter Value Min 2.400 RF Frequency Range RF Baud Rate Output power 250 20 18 Receive Sensitivity Antenna Type Antenna Gain Units Typ ‐106 Max 2.485 21 ‐104.5 ‐102 Inverted F +5 GHz kbps dBm dBm dBi Comments <2:1 VSWR load, Approx. +2dBm output power on channel 26 (2.485 GHz) At 1% PER Printed Peak gain Table 4: Standards/Compliance Standards/compliance FCC Title 47 CFR Part 15 IEC 61000 4‐2,3,4,5,6,8,9,11 ANSI C12.20 ANSI C12.1 ANSI C37.90.1 (1989) Radiated and Conducted Emissions (incl. intentional radiators) Electromagnetic Compatibility National Standard for Electricity Meters ‐ 0.2 and 0.5 Accuracy Classes Code for Electricity Metering Standard Surge Withstand Capability (SWC) Tests Table 5: Mechanical Parameter Size weight 5.5L x 5.0 W x 1.5 H 48.2 units Inches Table 6: Environmental Parameter Storage Temperature Operating Temperature Relative Humidity Min ‐40 ‐40 Max 85 85 85 Units °C °C Contact Information Technical Support: 1-888-390-5733 Internet: www.landisgyr.com Fax1-218-562-5530 E-mail:solutionsupport.na@landisgyr.com Gridstream RF E350 FOCUS AX PUBS‐0788‐0001 Rev A Notes Non‐condensing
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Tagged PDF : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Modify Date : 2009:10:19 10:34:09-04:00 Create Date : 2009:10:19 10:34:09-04:00 Metadata Date : 2009:10:19 10:34:09-04:00 Creator Tool : Adobe Acrobat 8.1 Combine Files Format : application/pdf Title : FCC Part 15 Creator : Brooke Copeland Document ID : uuid:97740754-9ed0-4df5-94c5-3456139ad1c7 Instance ID : uuid:a0b5a969-e638-4081-9b1c-5febfd80293f Producer : Adobe Acrobat 8.1 Page Count : 5 Author : Brooke CopelandEXIF Metadata provided by EXIF.tools