Limitation on Warranties and LiabilityInformation in this document is subject to change without notice. This manual or any part of it thereof may not be re-produced in any form unless permitted by contract or by written permission of Landis+Gyr.In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost prof-its) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages.© 2015 Landis+Gyr, Inc. All Rights ReservedM120 Module User GuidePublication: 98-1718Revision HistoryModification Date Revision Description Author06/09/2015 AA Released Charlie Goerges© 2015 Landis+Gyr • All rights reserved.
User Guide 98-1718 Rev AA 3M120 Module User GuideIntroductionThe M120 is a battery operated module designed for automated gas meter reading. The M120 is capable of recording gas consumption data from residential gas meters. It has a 2-way radio that is compatible with electric meters, routers, and mesh extenders for relaying sensor data to the utility.Federal Communication Commission (FCC) Compliance NoticeThis device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:1. This device may not cause harmful interference, and2. This device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:1. Reorient or relocate the receiving antenna.2. Increase the separation between the equipment and receiver.3. Consult Landis+Gyr or an experienced radio technician for help.UWARNING: Changes or modifications to this device not expressly approved by Landis+Gyr will void the equipment warranty.
M120 Module User Guide Landis+Gyr4 98-1718 Rev AA User GuideHost FCC Label RequirementsThe host label(s) must be clearly visible after the device is installed, and display the module FCC ID in the following format:Contains FCC ID: R7PER6R1S2The following statement must also be clearly visible:This device complies with part 15 of theFCC Rules. Operation is subject to thefollowing two conditions:(1) This device may not causeharmful interference, and (2) thisdevice must accept anyinterference received, includinginterference that may causeundesired operation.RF Exposure InformationIn accordance with FCC requirements of human exposure to radio frequency fields, the radiating element shall be installed such that a minimum separation distance of 20 centimeters (8 inches) will be maintained.Electrical CharacteristicsBattery:•Battery type: Lithium-Manganese Dioxide•Nominal voltage: 3.0 V•Capacity: 4800 mAh•Landis+Gyr Part number: 40-1235DC Characteristics:•Operating Voltage Range: 2.4 V - 3.3 V•Typical Sleep Current: 7 uARadio Characteristics:•Typical Antenna Gain: 0 dBi•Frequency Range: 902 MHz - 928 MHz•Modulation Format: FSK•Transmit Output Power (typical)•Single Channel Mode: - 27 dBm•Frequency Hopping Mode: 24 dBm•Receive sensitivity (typical)
Landis+Gyr M120 Module User GuideUser Guide 98-1718 Rev AA 5•9.6 kbps: -112 dBm•19.2 kbps: -110 dBm•38.4 kbps: -108 dBm•115.2 kbps: -101 dBm•Max Input Power, No Damage: 10 dBmFunctional DescriptionThe M120 is a wireless battery endpoint for the application of automatic gas meter reading. The primary function of the module is to record pulses that represent measurement of gas consumption, and then deliver the data to the utility for processing. The block diagram below demonstrates this operation. Figure 1. Operation Block DiagramThe module is designed to record pulses from a Form-C type pulse initiator. The pulse initiator is a sensor board that measures gas volume flow and relays the measurement to the M120 in the form of electrical pulses.The radio has two operating modes, frequency hopping and single channel. The frequency hopping mode is the normal operating mode for network communication. The single channel mode is a low power mode, and is primarily used for field diagnostic purposes.
M120 Module User Guide Landis+Gyr6 98-1718 Rev AA User GuideHost InstallationThe battery is connected to the battery connector. The sensor board is connected to the M120 through a flex-cable. See picture below. Figure 2. Sensor Board and Battery Connection to M120 ModuleThe M120 module and sensor board (pulse initiator) are designed to be heat-staked inside a plastic enclosure. See picture below. Figure 3. M120 Module and Sensor Board Staking LocationsBatteryConnector SensorBoardFlex CableM120ModuleHEAT STAKE THESE PINS TO HOLD SENSOR BOARD TO HOSTHEAT STAKE THESE PINS TO HOLD FLEX-CABLE TO HOSTHEAT STAKE THESE TWO PINS TO HOLD M120 TO HOST