Landis Gyr Technology IWRS5 Gridstream Series-5 IWR User Manual 12 0336 Exhibit Cover
Landis+Gyr Technology, Inc. Gridstream Series-5 IWR 12 0336 Exhibit Cover
Manual
Certification Exhibit FCC ID: R7PIWRS5 IC: 5294A-IWRS5 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Project Number: 12-0336 Manufacturer: Landis+Gyr Technology, Inc. Model: Gridstream Series-5 IWR Manual 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 20 13 Landis+Gyr Gridstream Series-5 IWR Data Sheet AF 01 /1 0/ Publication: 98-1297 Rev AA LANDIS+GYR CONFIDENTIAL INFORMATION Limitation on Warranties and Liability Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr. In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost profits) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages. Landis+Gyr Gridstream Series-5 IWR Data Sheet Publication: 98-1297 Rev AA Revision History Revision AA AF Landis+Gyr 6436 County Road 11 Pequot Lakes, MN 56472 Website: www.landisgyr.com E-mail: solutionsupport.na@landisgyr.com Technical Support: 1-888-390-5733 Work in progress 01 01/10/2013 Description /1 0/ Modification Date 20 13 © 201# Landis+Gyr, Inc. All Rights Reserved Author Kim Utesch © 2013 Landis+Gyr All rights reserved. Landis+Gyr Gridstream Series-5 IWR Data Sheet General The Landis+Gyr Gridstream Series-5 IWR provides a basis for a powerful RF wireless mesh network for remote data collection and end device monitoring and control. The radio provides full two-way peer-to-peer communication to all devices within the network. The IWR also offers advanced functionality, such as individual message prioritization, additional memory for localized intelligence, and a programming language Device Control Word (DCW) used to provide interface and control to distributed automation equipment. AF 01 /1 0/ 20 13 The IWR has one RS-232 serial port for the LAN Packet Port (LPP) and one RS-232/485 serial port for the Transparent Packet Port (TPP). The LAN Packet Protocol Port is used to communicate to devices that use the Gridstream IWR LAN Packet Protocol, such as a PC with configuration or diagnostic software. The Transparent Packet Port is a general-purpose data port that is used to transport byteoriented data, such as DNP 3.0, Modbus, or DF1. Figure 1. Landis+Gyr Gridstream Series-5 IWR Data Sheet 98-1297 Rev AA Landis+Gyr Gridstream Series-5 IWR Data Sheet Landis+Gyr IWR Usage The IWR was engineered specifically for varied needs of residential and commercial applications. It enables access to the RF mesh network using a standard RS-232 connection. Useful features of the IWR include: • User-friendly interface via RadioShop for configuring the IWR. The interface provides: • Current status information • Logical configurations for: • LPP port • TPP port Simultaneous connections per RS-232 interface by: • LPP applications • TPP applications 20 13 • /1 0/ FCC and Industry Canada Compliance FCC Class B 01 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and AF 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Consult Landis+Gyr or an experienced radio technician for help WARNING: Changes or modifications to this device not expressly approved by Landis+Gyr could void the user’s authority to operate the equipment. 98-1297 Rev AA Data Sheet Landis+Gyr Landis+Gyr Gridstream Series-5 IWR Data Sheet RF Exposure This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 22 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Industry Canada This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. 20 13 Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. /1 0/ This radio transmitter (5294A-IWRS5) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. 01 Approved Antenna: Omni-directional antenna, 5.5 dBi gain, 902-928 MHz, antenna impedance is 50 ohms. AF Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le présent émetteur radio (5294A-IWRS5) a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. Host FCC Label Requirement In the final installation, the following information must be visible: Data Sheet • Contains FCC ID: R7PIWRS5 • Contains IC: 5294A-IWRS5 • Module Model: Gridstream Series-5 IWR 98-1297 Rev AA Landis+Gyr Gridstream Series-5 IWR Data Sheet Landis+Gyr This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Gridstream Series-5 IWR Specifications Table 1. General Series-5 IWR Specifications Electrical (General) 6 - 28 VDC Input Current (in transmitting mode) 320 mA typical (12 VDC operation) Input Current (in receiving mode) 38 mA typical (12 VDC operation) RF Frequency Range 20 13 Input Voltage Range 902-928 MHz Channel Spacing 100 or 300 kHz depending on the mode RF Data Rate 9.6-115.2 Kbps /1 0/ Receiver -112 dBm (9.6 Kbps) Typical / -101 dBm (115.2 Kbps) Typical Co-channel rejection 10 dB Typical 01 Sensitivity (at 10% packet error rate) 30 dB Typical Alternate Channel Rejection 45 dB Typical AF Adjacent Channel Rejection Transmitter 21/25/30 dBm (user selectable) Modulation Type 2-FSK, GFSK Modulation Index Out-of-band Spurious Emissions <-70 dBc Output Power (at Antenna Connector) 98-1297 Rev AA Data Sheet
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 7 XMP Toolkit : 3.1-701 Producer : ScanSoft PDF Create! 7 Creator Tool : Microsoft Word - 12-0336 - Exhibit Cover.doc Create Date : 2013:01:25 15:13:54-05:00 Modify Date : 2013:01:25 15:13:55-05:00 Title : Microsoft Word - 12-0336 - Exhibit Cover.doc Creator : courtney.mcgann Author : courtney.mcgannEXIF Metadata provided by EXIF.tools