Landis Gyr Technology SSMM2TRP Solid State Meter Module User Manual 11 0444 Exhibit Cover

Landis+Gyr Technology, Inc. Solid State Meter Module 11 0444 Exhibit Cover

Manual

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598Certification ExhibitFCC ID: R7PSSMM2TRPFCC Rule Part: 15.247ACS Project Number: 11-0444Manufacturer: Landis+Gyr Technology, Inc.Model: L+G Solid State Meter ModuleManual
Draft 12/7/2012LANDIS+GYR CONFIDENTIAL INFORMATIONL a n d i s + G y r                                           Solid State Meter ModuleQuick Start GuidePublication: 98-1284 Rev AA
Draft 12/7/2012Limitation on Warranties and LiabilityInformation in this document is subject to change without notice. This manual or any part of it thereof may not be re-produced in any form unless permitted by contract or by written permission of Landis+Gyr.In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost prof-its) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages.Other brands or product names used are the trademarks or registered trademarks of their respective holders.© 2013 Landis+Gyr, Inc. All Rights ReservedElster Solid State Meter Module Quick Start GuidePublication: 98-1284Revision HistoryModification Date Revision Description Author11/8/2012 AA In Progress Vicky CostelloLandis+Gyr30000 Mill Creek Avenue, Suite 100Alpharetta, GA 30022Website: www.landisgyr.comE-mail: solutionsupport.na@landisgyr.comTechnical Support: 1-888-390-5733Copyright© 2013 Landis+GyrAll rights reserved.
Draft 12/7/2012Landis+Gyr Confidential Information 98-1284 Rev AA 3Solid State Meter Module Quick Start GuideOverviewThe Landis+Gyr Solid State Meter Module (SSMM) is designed to provide active energy (Kilo-Watt hour) data from Landis+Gyr S4e meters for use in residential and industrial commercial services. Figure 1 - 1.  Landis+Gyr Solid State Meter ModuleThe meter kit includes:•Landis+Gyr Solid State Meter Module•Landis+Gyr S4e Meter•Antenna
Draft 12/7/2012Solid State Meter Module Quick Start Guide Landis+Gyr4 98-1284 Rev AA Landis+Gyr Confidential InformationRequired SoftwareTo work with the endpoint, you need at least one of the following software tools and documentation:•UtiliNet Solution Center (USC)•Meter Master Lite software•Meter Master Lite Quick Start Guide, publication number 98-0071•Landis+Gyr 1132Prog\1132Com softwareLandis+Gyr recommends you have RF Verify software and the RF Verify User Guide, publication number 98-0069.LabelsThe endpoint contains the following labels:Figure 2.  Label IdentificationTable 1. Landis+Gyr Label Identification         Label Description1 Landis+Gyr Name Plate AEP compliant bar code that defines meter manufacturer, form, base, test voltage and current, watt-hour constant, serial number, and customer specific information.Manufacturer or customer specified serial numberManufacturer model and style number2 Landis+Gyr FCC ID Federal Communications Commission (FCC) Identification (ID) number assigned to the Landis+Gyr Solid State Meter Module for use in the Landis+Gyr S4e meter. 3 Landis+Gyr LAN ID Identifies the Solid State Meter Module to the Landis+Gyr network. (printed and barcoded).123
Draft 12/7/2012Landis+Gyr Solid State Meter Module Quick Start GuideLandis+Gyr Confidential Information 98-1284 Rev AA 5LAN IDThe LAN ID is a unique identifier for each Landis+Gyr endpoint. Landis+Gyr provides the LAN address. You cannot change the LAN ID of a radio.Features and FunctionsEndpoint RegistrationThe endpoint is automatically registered with the host system. No special tools are needed during installation.Admin packets are sent once each hour at a random time during the hour and play a crucial role in the automatic discovery of a meter by the Landis+Gyr system. They tell what kind of meter the module interfaces with, and other characteristics, such as the scaling constant, number of dials, and the firmware version.Admin packets include:Communication and Retrieving DataA microprocessor on the communications module counts pulses, records usage over multiple intervals, and transmits the information to the head end system. Several different packet types are sent.The most frequently sent packet contains the current rotational count and historical interval data that is useful for load profiling and time-of-use metering. Another less frequently sent (Admin) packet contains the current cumulative rotation count, useful for basic automatic meter reading applications. An Admin packet is sent once hourly and contains the information listed in Table 2.Power Outage/RestorationThe Solid State Meter Module determines when a meter power failure has occurred. The communication module saves critical endpoint data to non-volatile memory, creates and sends a power fail message to the host system that includes the LAN ID.When power is restored, the communication module sends a Power Up message to the host system. This message includes the following information:•LAN IDTable 2. Admin Packet InformationMeter ID Identifies the customerProtocol ID Identifies the type of meter.Scaling Constant Tells how to convert meter readings into real units such as kWhNumber of dials Also referred to as displayed digits.Maximum Sensor Change Rate Tells how much the meter reading can change in a certain period of time.Firmware Version Specifies the firmware revision number.Current Cumulative Reading from the meter
Draft 12/7/2012Solid State Meter Module Quick Start Guide Landis+Gyr6 98-1284 Rev AA Landis+Gyr Confidential Information•Total count•Last ten interval countsCustomer ServiceContact Landis+Gyr Customer Support at solutionsupport.na@landisgyr.com or call 888-390-5733 with any questions or problems for guidance through the troubleshooting process.ComplianceFCC Class BThis device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the antenna.•Increase the separation between the equipment and receiver.•Consult Landis+Gyr or an experienced radio technician for help.UWARNING: Changes or modifications to this device not expressly approved by Landis+Gyr could void the user’s authority to operate the equipment.RF ExposureIn accordance with FCC requirements of human exposure to radio frequency fields, the radiating element shall be installed such that a minimum separation distance of 20 centimeters will be maintained.Host FCC Label RequirementIn the final installation, the following information must be visible:“Contains FCC ID: R7PSSMM2TRP
Draft 12/7/2012Landis+Gyr Solid State Meter Module Quick Start GuideLandis+Gyr Confidential Information 98-1284 Rev AA 7This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.”
Draft 12/7/2012Solid State Meter Module Quick Start Guide Landis+Gyr8 98-1284 Rev AA Landis+Gyr Confidential InformationProduct SpecificationsTable 3. Landis+Gyr Solid State Meter Module SpecificationsCategory Specification Value or RangeCompatible MetersLandis+Gyr Supported Meter FormsNOTE: Contact Landis+Gyr for additional forms.Form Class1S 2002S 2002SE 3203S 103S 204S 209S/8S 2010A/8A 2025S20012S12SE 32012K 48016/15/14S 20016/15/14A 12016/15/14SE 32016/15/14K 48025S 20027K 48029S 2036A (6A) 2036S (6S) 2045A (5A) 2045S (5S) 2056S 20ElectricalVoltage 8 to 17.1 VDC Input Current 50mARFOutput Power 22-26.5 dBm Transmit Frequency 917.58 MHz (Fixed))
Draft 12/7/2012Landis+Gyr Solid State Meter Module Quick Start GuideLandis+Gyr Confidential Information 98-1284 Rev AA 9Standards ComplianceFCC Title 47 CFR Part 15 Subpart B & CRadiated and Conducted EmissionsIEC 61000 4-2,3,4,5 Electromagnetic CompatibilityANSI C12.1-2011 Electricity MeteringANSI C12.20-2002 Electricity Meters StandardANSI C37.90.1Substation Standards - Fast Transient and Oscillatory WaveformANSI/IPC-A-610-Class 2 Workmanship Standard for Electronic AssembliesEnvironmentalGeneral Environmental Outdoor, rain-protected, sunlight-exposedOperating Temperature Range -40 to +85 C (under meter glass)Humidity 10% to 95% relative humidity, non-condensingMechanicalSize (Meter & Module)Refer to Landis+Gyr S4/S4e Family of Solid State Meters, Instruction/Technical Manual for more details.Weight (Meter & Module)Refer to Landis+Gyr S4/S4e Family of Solid State Meters, Instruction/Technical Manual for more details.Table 3. Landis+Gyr Solid State Meter Module Specifications(Continued)Category Specification Value or Range
Draft 12/7/2012Solid State Meter Module Quick Start Guide Landis+Gyr10 98-1284 Rev AA Landis+Gyr Confidential Information

Navigation menu