Landis Gyr Technology SSMM2TRP Solid State Meter Module User Manual 11 0444 Exhibit Cover

Landis+Gyr Technology, Inc. Solid State Meter Module 11 0444 Exhibit Cover

Manual

Download: Landis Gyr Technology SSMM2TRP Solid State Meter Module User Manual 11 0444   Exhibit Cover
Mirror Download [FCC.gov]Landis Gyr Technology SSMM2TRP Solid State Meter Module User Manual 11 0444   Exhibit Cover
Document ID1947699
Application IDmu2fApMOXud+uRLeHnqGCg==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize28.7kB (358727 bits)
Date Submitted2013-04-22 00:00:00
Date Available2013-04-22 00:00:00
Creation Date2013-01-21 15:45:15
Producing SoftwareScanSoft PDF Create! 7
Document Lastmod2013-01-21 15:45:16
Document TitleMicrosoft Word - 11-0444 - Exhibit Cover.doc
Document CreatorMicrosoft Word - 11-0444 - Exhibit Cover.doc
Document Author: courtney.mcgann

Certification Exhibit
FCC ID: R7PSSMM2TRP
FCC Rule Part: 15.247
ACS Project Number: 11-0444
Manufacturer: Landis+Gyr Technology, Inc.
Model: L+G Solid State Meter Module
Manual
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
12
Landis+Gyr
Solid State Meter Module
Quick Start Guide
ra
ft
12
/7
/2
Publication: 98-1284 Rev AA
LANDIS+GYR CONFIDENTIAL INFORMATION
Limitation on Warranties and Liability
Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr.
In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost profits) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised,
knew, or should have known of the possibility of such damages.
12
Other brands or product names used are the trademarks or registered trademarks of their respective holders.
© 2013 Landis+Gyr, Inc. All Rights Reserved
Publication: 98-1284
ft
12
/7
/2
Elster Solid State Meter Module Quick Start Guide
Revision History
Modification Date
11/8/2012
Revision
AA
ra
Landis+Gyr
30000 Mill Creek Avenue, Suite 100
Alpharetta, GA 30022
Website: www.landisgyr.com
E-mail: solutionsupport.na@landisgyr.com
Technical Support: 1-888-390-5733
Description
In Progress
Copyright© 2013 Landis+Gyr
All rights reserved.
Author
Vicky Costello
Solid State Meter Module
Quick Start Guide
Overview
ra
ft
12
/7
/2
12
The Landis+Gyr Solid State Meter Module (SSMM) is designed to provide active energy (Kilo-Watt
hour) data from Landis+Gyr S4e meters for use in residential and industrial commercial services.
Figure 1 - 1. Landis+Gyr Solid State Meter Module
The meter kit includes:
•
Landis+Gyr Solid State Meter Module
•
Landis+Gyr S4e Meter
•
Antenna
Landis+Gyr Confidential Information
98-1284 Rev AA
Solid State Meter Module Quick Start Guide
Landis+Gyr
Required Software
To work with the endpoint, you need at least one of the following software tools and documentation:
•
UtiliNet Solution Center (USC)
•
Meter Master Lite software
•
•
Meter Master Lite Quick Start Guide, publication number 98-0071
Landis+Gyr 1132Prog\1132Com software
Landis+Gyr recommends you have RF Verify software and the RF Verify User Guide, publication
number 98-0069.
Labels
12
The endpoint contains the following labels:
ft
12
/7
/2
ra
Figure 2. Label Identification
Table 1. Landis+Gyr Label Identification
Label
Description
Landis+Gyr Name Plate
AEP compliant bar code that defines meter manufacturer, form,
base, test voltage and current, watt-hour constant, serial number,
and customer specific information.
Manufacturer or customer specified serial number
Manufacturer model and style number
Landis+Gyr FCC ID
Federal Communications Commission (FCC) Identification (ID)
number assigned to the Landis+Gyr Solid State Meter Module for
use in the Landis+Gyr S4e meter.
Landis+Gyr LAN ID
Identifies the Solid State Meter Module to the Landis+Gyr network.
(printed and barcoded).
98-1284 Rev AA
Landis+Gyr Confidential Information
Landis+Gyr
Solid State Meter Module Quick Start Guide
LAN ID
The LAN ID is a unique identifier for each Landis+Gyr endpoint. Landis+Gyr provides the LAN
address. You cannot change the LAN ID of a radio.
Features and Functions
Endpoint Registration
The endpoint is automatically registered with the host system. No special tools are needed during
installation.
12
Admin packets are sent once each hour at a random time during the hour and play a crucial role in
the automatic discovery of a meter by the Landis+Gyr system. They tell what kind of meter the
module interfaces with, and other characteristics, such as the scaling constant, number of dials, and
the firmware version.
ft
12
/7
/2
Admin packets include:
Table 2. Admin Packet Information
Meter ID
Identifies the customer
Protocol ID
Identifies the type of meter.
Scaling Constant
Tells how to convert meter readings into real units such as kWh
Number of dials
Also referred to as displayed digits.
Maximum Sensor Change Rate
Tells how much the meter reading can change in a certain period of
time.
Firmware Version
Specifies the firmware revision number.
ra
Current Cumulative Reading from the meter
Communication and Retrieving Data
A microprocessor on the communications module counts pulses, records usage over multiple
intervals, and transmits the information to the head end system. Several different packet types are
sent.The most frequently sent packet contains the current rotational count and historical interval data
that is useful for load profiling and time-of-use metering. Another less frequently sent (Admin)
packet contains the current cumulative rotation count, useful for basic automatic meter reading
applications. An Admin packet is sent once hourly and contains the information listed in Table 2.
Power Outage/Restoration
The Solid State Meter Module determines when a meter power failure has occurred. The
communication module saves critical endpoint data to non-volatile memory, creates and sends a
power fail message to the host system that includes the LAN ID.
When power is restored, the communication module sends a Power Up message to the host system.
This message includes the following information:
•
LAN ID
Landis+Gyr Confidential Information
98-1284 Rev AA
Solid State Meter Module Quick Start Guide
•
Total count
•
Last ten interval counts
Landis+Gyr
Customer Service
Contact Landis+Gyr Customer Support at solutionsupport.na@landisgyr.com or call 888-390-5733
with any questions or problems for guidance through the troubleshooting process.
Compliance
12
FCC Class B
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
ft
12
/7
/2
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may
cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
•
Increase the separation between the equipment and receiver.
Consult Landis+Gyr or an experienced radio technician for help.
•
Reorient or relocate the antenna.
ra
•
WARNING: Changes or modifications to this device not expressly approved by Landis+Gyr
could void the user’s authority to operate the equipment.
RF Exposure
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating
element shall be installed such that a minimum separation distance of 20 centimeters will be
maintained.
Host FCC Label Requirement
In the final installation, the following information must be visible:
“Contains FCC ID: R7PSSMM2TRP
98-1284 Rev AA
Landis+Gyr Confidential Information
Landis+Gyr
Solid State Meter Module Quick Start Guide
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
ra
ft
12
/7
/2
12
(2) This device must accept any interference received, including interference that may cause
undesired operation.”
Landis+Gyr Confidential Information
98-1284 Rev AA
Solid State Meter Module Quick Start Guide
Landis+Gyr
Product Specifications
Table 3. Landis+Gyr Solid State Meter Module Specifications
Value or Range
Specification
Landis+Gyr Supported Meter
Forms
Compatible
Meters
NOTE: Contact Landis+Gyr
for additional forms.
Form
Class
1S
200
2S
200
2SE
320
3S
3S
10
20
ft
12
/7
/2
4S
12
Category
20
9S/8S
20
10A/8A
20
25S
200
ra
12S
12SE
320
12K
480
16/15/14S
200
16/15/14A
120
16/15/14SE
320
16/15/14K
480
25S
200
27K
480
29S
20
36A (6A)
20
36S (6S)
20
45A (5A)
20
45S (5S)
20
56S
20
Voltage
8 to 17.1 VDC
Input Current
50mA
Output Power
22-26.5 dBm
Transmit Frequency
917.58 MHz (Fixed))
Electrical
RF
98-1284 Rev AA
Landis+Gyr Confidential Information
Landis+Gyr
Solid State Meter Module Quick Start Guide
Table 3. Landis+Gyr Solid State Meter Module Specifications(Continued)
Standards
Compliance
Specification
Value or Range
FCC Title 47 CFR Part 15
Subpart B & C
Radiated and Conducted
Emissions
IEC 61000 4-2,3,4,5
Electromagnetic Compatibility
ANSI C12.1-2011
Electricity Metering
ANSI C12.20-2002
Electricity Meters Standard
ANSI C37.90.1
Substation Standards - Fast
Transient and Oscillatory
Waveform
ANSI/IPC-A-610-Class 2
Workmanship Standard for
Electronic Assemblies
General Environmental
Operating Temperature Range
Outdoor, rain-protected,
sunlight-exposed
-40 to +85 C (under meter
glass)
ft
12
/7
/2
Environmental
12
Category
Humidity
10% to 95% relative humidity,
non-condensing
Size (Meter & Module)
Refer to Landis+Gyr S4/S4e
Family of Solid State Meters,
Instruction/Technical Manual
for more details.
Weight (Meter & Module)
Refer to Landis+Gyr S4/S4e
Family of Solid State Meters,
Instruction/Technical Manual
for more details.
ra
Mechanical
Landis+Gyr Confidential Information
98-1284 Rev AA
Landis+Gyr
ra
ft
12
/7
/2
12
Solid State Meter Module Quick Start Guide
10
98-1284 Rev AA
Landis+Gyr Confidential Information

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 11
XMP Toolkit                     : 3.1-701
Producer                        : ScanSoft PDF Create! 7
Creator Tool                    : Microsoft Word - 11-0444 - Exhibit Cover.doc
Create Date                     : 2013:01:21 15:45:15-05:00
Modify Date                     : 2013:01:21 15:45:16-05:00
Title                           : Microsoft Word - 11-0444 - Exhibit Cover.doc
Creator                         : courtney.mcgann
Author                          : courtney.mcgann
EXIF Metadata provided by EXIF.tools
FCC ID Filing: R7PSSMM2TRP

Navigation menu