Leica Geosystems CPD CPD0401 Bluetooth Laser Distancemeter User Manual Daumenregister

Leica Geosystems AG, CPD Bluetooth Laser Distancemeter Daumenregister

Contents

Users Manual 1 of 2

2Display Leica DISTO™ plus 1.0.0 GBdeGBfritesnljaD5-Z11st function level2nd function levelDisplayD5-Z21 Laser "on"2 Measurement reference (front/ stand/ rear)3 Information4Bluetooth® on/off5 Display of the mathematical signs/operations6 Main display (e.g. measured distance)7 Distance measurement8 Tracking9Area/ Volume10 min. Tracking11 max. Tracking12 Pythagoras function13 Pythagoras function with partial height14 Units with exponents (²/ ³)15 Time symbol for time delay release16 Save constant17 Contact customer service18 3 auxiliary displays (e.g. previous values)19 SET20 RESET21 Battery display22 2nd function level23 Recall stored constant (max. 10)24 Recall last 15 values25 Illumination (on/ off)26 Beep (on/ off)27 Offset setting1 Distance measuring, Tracking10 Menu22nd - function level 1 or 2 11 Illumination3 Meas. reference 12 Multiply [ x ]/ Timer Release4 Areas, Volumes 13 On/off key5 Measuring 14 Clear6 min. / max. Tracking 15 Mermory, Stack7 Bluetooth® ON/OFF 16 Equals, Enter8 Pythagoras functions 17 Minus [ - ]9Plus [ + ]123456718 19891011121314151617 202122232425262718 delete 23 direction upward19 enter 24 direction downward20 direction left upward 25 direction right downward21 direction left 26 direction right22 direction left downward 27 direction right upward1192364578109 11 12 13151617142325 212722 18202426
3How to Use the InstrumentLeica DISTO™ plus 1.0.0 GBdeGBfritesnljaHow to Use the InstrumentInserting / replacing the batteries1 Depress the locking clip and slide end piece to the right.D5-Z32 Remove battery cover. Replace batteries.Appears on the display if battery voltage is too low.For type of battery, refer to Technical Data.)Fit batteries the right way round.)Use only Alkaline batteries.3 Push in end piece and listen for locking click sound.1st Function levelLeica DISTO™ plus switching on/offBriefly press.The illumination, Battery and Beep symbols are displayed until the first key press.The instrument can be switched off from any menu point.)The instrument switches off automatically after 90 seconds if no key is pressed.)An unwanted switching off of the Bluetooth-data-connection is blocked by special precautions. Please refer to page 11.Clear keyThe clear key may be pressed before or after a measurement/ calculation.The clear key may be pressed before or after a measurement/ calculation.In Menu Mode it resets to Normal Mode.During a function (area, volume or Pythagoras) the single measurements can be deleted step by step and remeasured.In the menu settings, the program is terminated if the Equal (=) and Enter keys are not pressed.IlluminationBriefly press.Illumination is switched on/off with a key press.)Illumination switches off after 30 seconds if no key is pressed.Reference settingPress until desired reference setting appears.
41st Function level Leica DISTO™ plus 1.0.0 GBdeGBfritesnljaPossible settingsD5-Z4front stand rear)At the back of the instrument is a 1/4" camera thread for the stand.)Settings remain valid until the reference level is changed or the instrument is automatically or manually switched off.)Basic setting: rear referenceMeasuringDistance measurementPress and the laser is switched on, the instrument is in "Pointing Mode".A second press starts the distance measurement.The result is displayed immediately in the selected unit.)With the instrument on and the laser off, it is in "Normal Mode".)With the laser on, it is in "Pointing Mode".Measuring from flat planesD5-Z5)For stable measuring turn bumper 90°.Measuring from cornersD5-Z6Continuous measurement (Tracking)Press untilappears on the display.Continuous measurement is started and the result is displayed.Press to end Tracking Mode. Last result is shown in the display.Example: Stake off distanceD5-Z7Laser in continous operationPress until a long "beep" is heard. Now the laser is activated permanently.A distance measurement is triggered each time the key is pressed.Press to end continuous laser operation.
51st Function levelLeica DISTO™ plus 1.0.0 GBdeGBfritesnljaTime delay releaseInstrument must be in Pointing Mode.Press and hold until desired time delay has been reached (max. 60 seconds).appears on the display.Once the key is released, the remaining seconds (e.g. 59, 58, 57...) are displayed, until measuring. The last 5 seconds are counted down with a "beep".After the last "beep", the measurement is made and the value displayed.Example: Measuring without any key activation.D5-Z8CalculationsAreaPress untilappears on the display. The side to be measured blinks.Make 2 measurements (l x w).The result and the two partial results appear on the display.VolumePress untilappears on the display.The side to be measured blinks.Make 3 measurements (l x w x h).The result and the three partial results appear on the display.Menu/ SettingsThe menus allow a free selection of the settings that are to remain valid after switching off the instrument. The functions follow each other endlessly (rollmode).Press to toggle between the functions.D5-Z94 Measure with offset (add/reduce)5 Selecting measuring units6 Beep7 ResetMenü aufrufen:Press until desired menu point appears or with key [+ / -] switch between the various menu points.Confirm selection, activate menu point.or with key [+ / -] change setting as desired.
61st Function level Leica DISTO™ plus 1.0.0 GBdeGBfritesnljaConfirm selection, reset to Normal Mode.)"Clear Entry" may also be used (e.g. to cancel a selection).Selecting units (menu)Selectable units:Measure with offset (menu)D5-Z10Call up menu point.blinks on the display.With key [+ / -] set desired offset (=shifting reference) (e.g. 0,015m); quick set by keeping key pressed.For larger steps hold additionally.)Offset can be positive (add) or negative (reduce)!Confirm setting.Is displayed continuously if offset  ≠ 0.)Subject to set offset, the measured results are displayed.Using this function you can measure with rough size, as an example!Please make this a rule: After rough size measurement always set the Leica DISTO™ plus to offset 0.000: Call up function as described Press.Confirm function.)After making/changing settings, it is imperative that a test measurement is performed.Resetting (menu)Call up menu point.starts blinking on the display.With key [+ / -] select components to be reset. To choose from:Stack/ MermoryStack and ConstantIf additional symbols e.g. units are shown in the display, the following values are reset:– Offset (=0), Beep (On) and Units (meter) Selected components are reset; back to Measuring Mode.Save values (constants)Measure/ calculate desired value (e.g. height of room, area, volume).Press longer.– m (mm) = 0.000 m – 14’ 06’’ 1/16 = ’ ’’ 1/16– m (cm) = 0.00 m – in = 0.0 in– ft = 0.00 ft – in 1/16 = 0 1/16in– ft in 1/16 = 0.00 1/16ft in
71st Function levelLeica DISTO™ plus 1.0.0 GBdeGBfritesnljastarts to blink on the display.With key [+ / -] adjust value as desired (e.g. from 2.297m to 2.300m).For larger steps press and hold additionally.Press to adjust unit (²/³).)The adjustment is for m, m² and m³ rsp. ft, ft² and ft³ only.Confirm.and a number (=memory location) starts to blink.With key [+ / -] select memory location (1-10).Save value.Recalling the constantBriefly press.and the contents of the first constant memory location are displayed (e.g. 2.300m).With key [+ / -] select desired mermory (1 to 10).Confirm; value is ready to be used for (e.g. calculating an area) or Recall last measured value (Stack)Briefly press twiceand the last value in the display is shown.With key [+ / -] select desired value (max. 15!).Confirm; value is ready to be used for (e.g. calculating an area).Tracking - MinimumD5-Z11Determine the minimum dimension, e.g. ceiling height, without having to precisely align to the normal.Press untilappears on the display.Aim Leica DISTO™ plus approximately at the target point.Activate continuos measurement with a brief press.Move the Leica DISTO™ plus a large amount around the target point.Stop continuous measurement.The smallest measurement is displayed (e.g. 3.215m = height of room).)Both planes (e.g. floor/ ceiling, walls) must be nearly parallel to each other.Tracking - MaximumD5-Z12
81st Function level Leica DISTO™ plus 1.0.0 GBdeGBfritesnljaDetermine maximum dimension, e.g. to determine the (room) diagonal.Press untilappears on the display.Move the Leica DISTO™ plus a large amount around the target point.Activate continuous measurement with a brief press.Slowly rotate the Leica DISTO™ plus to the right/ left past the corner.Stop continuous measurement.The largest measurement is displayed (e.g. 12.314m = diagonal of room).CalculationsPartial heights, partial distancesMake measurement.Add by [ + ] key/ Subtract by[ - ] key.Make additional measurements.= Result.)In the same way chain values (= any amount of distance measurements) and sums of areas/ volumes can be added up.)During calculations "Clear" is available as long as the function has not been executed!MultiplicationMake measurement (e.g. 8.375m).Multiplication by pressing [ x ] key.Additional measurements (e.g. 8.375m).= Area (e.g. 29.313m²))The volume can be calculated by an additional multiplication following an area calculation.This function can be used for calculating areas or volumes with individual partial heights/ partial distances.Doubling a measured valueIt is easy to double the measured values, e.g. to determine the length of walls in a room:Make measurement.Add by [ + ] key.Make additional measurements.= Sum (=half circumference)With key [ + ] repeat, double measured value.= Sum (=circumference)D5-Z13Pythagoras, height/ width measure-ment)The measuring sequence must be adhered to in any case!)All three (two) points must be on a vertical or horizontal line in the plane of the wall!
91st Function levelLeica DISTO™ plus 1.0.0 GBdeGBfritesnlja)With each of the distance measurements you can use:• a simple distance measurement,• a value from stack/ mermory or• a measurement with time delay release.)For short distances, a good base behind the instrument is sufficient for mechanical alignment. )You will obtain the best results if the Leica DISTO™ plus is rotated around a fixed point (rear edge, thread position) and the axis of the laser beam passes through this axis. The Leica DISTO™ plus should not be placed on a camera tripod without an adapter, as the axis of the laser beam would be 70 to 100 mm above the instru-ment’s axis of rotation. Without the adapter this would lead to significant height deviations in the measurements. Determination with two pointsFor estimating the height/ width of buildings. Very useful for making measure-ments from standing position (no bending) if the height is determined with two or three distances.Press untilappears on the display; laser is activated and "1 ---" starts blinking.Aim at the upper point (1).Trigger measurement; do not move the instrument!Value is accepted.appears on the display and "2 ---" starts blinking.Point the Leica DISTO™ plus approximately horizontal (2).Press, a continuous measurement is triggered.Move the Leica DISTO™ plus a large amount around the ideal measurement point. Stop of continuous measurement. The height and width are displayed from measurements (Pythagoras).Detemination with 3 pointsPress untilappears on the display; laser is activated and "1 ---" starts blinking.Aim at the upper point (1).Trigger measurement; do not move the instrument!Value is accepted.appears on the display and "2 ---" starts blinking.Point the Leica DISTO™ plus approximately horizontal (2).Press, a continuous measurement is triggered.
102nd Function level Leica DISTO™ plus 1.0.0 GBdeGBfritesnljaMove the Leica DISTO™ plus a large amount around the ideal measurement point. Stop of continuous measurement. Value is accepted and and on the display "3 ---" starts blinking.Aim at the lower point (3).Trigger measurement; do not move the instrument!The height and width are displayed from three measurements (Pythagoras).Determination of a partial height with 3 pointsHeight determination between point 1 and point 2 with three measured points.Press untilappears on the display; laser is activated and"1 ---" starts blinking.Aim at the upper point (1).Trigger measurement; do not move the instrument!Value is accepted and on the display "2 ---" starts blinking.Trigger measurement; do not move the instrument!Value is accepted.appears on the display and "3 ---" starts blinking.Press, a continuous measurement is triggered.Move the Leica DISTO™ plus a large amount around the ideal measurement point.Stop of continuous measurement. The height and width are displayed between point 1 and 2 (Pythagoras).2nd Function level)Only in the second level can measured values be transferred or corrected with the Leica DISTO™ plus.The type and number of functions that can be activated in the second function level depend on the software used.Switching on the Bluetooth® Briefly press.If Bluetooth® is switched on, this icon appears in the display. The data connection must be built up by the application software on a Pocket PC or PC. As long as the connection is being built up, this icon will be blinking.)If during 120 seconds after switching on the Bluetooth® no connection is established with the Pocket PC or PC, then the Bluetooth® is switched off automati-cally.
11 2nd Function levelLeica DISTO™ plus 1.0.0 GBdeGBfritesnljaSwitching off the Bluetooth® )Before switching off the Bluetooth® , always change to the first function level Briefly press.Bluetooth® is switched off,when this icon is no longer visible)If still in the second function level, the Bluetooth® cannot be swictched off. This is a safety precaution to prevent an accidential interruption of the Bluetooth® connection.Before the Leica DISTO™ plus can be switched off, the Bluetooth® function has to be switched off. The direction arrowsD5-Z14The eigth arrow keys below the Leica DISTO™ plus keyboard are used to input directions (orthogonal and diagonal) when generating a spatial drawing. Trigger a measurement in the usual way (even if the second level is active, these keys remian functional), the value appears in the display. Select the arrow key that corresponds to the direction needed for your spatial drawing. When this arrow key is pressed, the distance is transferred according to value and direction to the data receiver (Pocket PC or PC). Depending on the software used, the arrow keys can also control the cursor (e.g. Excel).Transfer of the measured valuesPress the arrow key briefly. A a thin line will be drawn to scale.D5-Z15Confirmation (or deletion) of a trans-ferred measuring valueD5-Z16
12User Information Leica DISTO™ plus 1.0.0 GBdeGBfritesnljaPress briefly to confirm that the correct line was drawn. The line is then drawn thicker with the measurement dispayed.Press briefly to clear a wrong line. .Is the measurement is still displayed in the Leica DISTO™ plus, it can be transferred again by pressing the correct arrow key. Other functions are described in the manual of the software used.During data transferAs long as there is no confirmation of a successful data transfer from the Pocket PC or PC, no new measurement can be triggered. Appears and "240" blinks, if after 2 seconds no data transfer occurs.Press briefly to acknowledge the display. Repeat measurement and data transfer.Remark to the softwareThe two free software progams "plus-draw" and "plus-XL" are included to demonstrate the basic applications of the Leica DISTO™ plus and are designed to perform simple tasks (spatial drawings with measurements , data transfer into an Excel table etc.)Leica Geosystems gives no warranty on the free software nor on their functionality and does not offer any support. Leica Geosystems is not liable for any damage resulting from the use of the free software and is not obligated to make corrections on them or to develop additional functions for them (updates, upgrades etc.).There are a number of commercially available software programs that provide the required functions. Please visit our homepage www.disto.com for details.User InformationRangeIn daylight (outdoors) always work with a laser viewfinder (see page 13). If neceesary, shade the target. If required, use a target plate.Increased range:At night, at dusk and when target area is in the shade.Reduced range / increased measuring time:Against mat and dark surfaces (also plants and trees) a reduction of the range may occur as well as an increase in measuring time. Rough surfacesOn a rough surface (e.g. coarse plaster) measure against the centre of the illuminated area.To avoid measuring to the bottom of plaster joints:Use target plate, 3M "Post-it" or board.Transparent surfacesTo avoid measuring errors, do not measure towards colorless liquids (e.g. water) or (dust free) glass, styropor.or similar semi- permeable surfaces. For materials and liquids unfamiliar to you always take a trial measurement.)When aiming through panes of glass, of if there are several objects in the line-of-sight erroneous measure-ments can occur.
13 Technical DataLeica DISTO™ plus 1.0.0 GBdeGBfritesnljaWet, smooth or high-gloss surfaces1 Aiming at a "Acute" angle deflects the laser beam. The Leica DISTO™ plus may receive a signal that is too weak (error message 255).2 If aiming at a right angle, the Leica DISTO™ plus may receive a signal that is too strong (error message 256).Inclined, round surfacesCan be measured with the laser.Requirement: There is enough area on the target surface for the laser spot.Using a target plateUse target plates 563875 (DIN C6) or 723385 (DIN A4’), if the signal is too weak (e 255), if the targeted surface is too rough, if the surface has poor reflection or during dayligh when measuring from more than 30 meters away. • White surfaces: to up approx. 30 m• Brown surfaces: from approx. 30m to 200 m In the fieldLeica DISTO™ plus is equipped with an integrated telescopic viewfinder (2x magnification).With measurements from a distance of 25 m the laser spot is in the centre of the crosshairs. Below a distance of 25 m the laser spot moves to the edge of the crosshairs.D5 Z_telescopTechnical DataMeasuring accuracy(2x standard deviation) typ.: ± 1.5mm   /   max.:  ± 3mm*Smallest unit displayed 1mm**Range (from about 30m, use target plate) 0.2m up to 200 mTime for a measurement dist / trc 0.5...ca.4s  /  0.16...ca.1s∅ Laser spot (at distance) 6 / 30 / 60 mm  (10 / 50 / 100 m)Integrated telescopic viewfinder Illumination Multiline display Multifunctional bumper Time delay release Pocket calculator Bluetooth®Tracking Constant 10 valuesmin./ max. Tracking. Pythagoras Mermory (Stack) 15 valuesBattery, Type AA, 2x 1.5V up to 10’000 measurements ***(only with Alkaline batteries!)Splash and dustproof IP54 acc. IEC529: splash and dustproofDimension and weight 172 x 73 x 45 mm, 335gMeasuring accuracy of bubble 1°Temperature range StorageOperating-25°C to +70°C(-13°F to +158°F)-10°C to +50°C (-14°F to +122°F)
14Message Codes Leica DISTO™ plus 1.0.0 GBdeGBfritesnlja* Maximum deviation occurs under unfavorable condi-tions, such as in bright sunlight or when measuring to inadequately reflecting surfaces. For distances over 30m-without using a target plate- themaximum devia-tion may increase by ±0.1mm to maximum ± 10mm. For more information, refer to www.disto.com.** As of 100m the measuring units are displayed in cm.*** Reduced when using the Bluetooth® functionMessage CodesError messageappears beside the message number on the display.Please call your local dealership and specify the message code. Should the message continue to appear after several starts, then the instrument is defective. CareLook after the optical surfaces with the same care that you would apply to spectacles, cameras and field glasses.The most current information can be found on our homepage:www.disto.com We publish the addresses of specialized software mannufacturers . However, we are not responsible for the correctness of their specifications or for the performance of their software. For software developers, the Leica DISTO™ plus Online-Interface description is available.All illustrations, descriptions and technical specifica-tions are subject to change without prior notice.Message Code Cause Remedy203 Wrong sequence with Pythagoras meas.Carry out measurement in correct sequence204 Calculation error Repeat procedure240 Transmission error  Repeat procedure252 Temperature too high, above 50°C (measuring)Cool down instrument253 Temperature too low, below -10°C (measuring)Warm up instrument255 Receiver signal too weak, measurement time too long, distance <200 mmUse target plate measurement time >10 sec.256 Received signal too powerfulUse target plate (correct side)257 Wrong measurement, ambient brightness too highUse target plate260 Laser beam interrupted Repeat measurementAll other messages Call service "System"Message Code Cause Remedy