Leica Geosystems CPD IIS01 photogrammetric and laser distance meter User Manual My

Leica Geosystems AG, CPD photogrammetric and laser distance meter My

Contents

  • 1. RFF-IIS01 UserMan
  • 2. RFF-IIS01 User Man

RFF-IIS01 UserMan

Leica BLK3D
Overview 2
Technical data 3
Instrument Set-up 7
Reality Capture 11
Laser 14
Sketch & Document 17
Organiser 21
Care 22
Warranty 23
Safety instructions 24
Leica BLK3D 1
Overview
Ove rview
Components
The Leica BLK3D is a remote meas-
urement tool with a class 2 laser. It
enables to measure distances within a pic-
ture at any time. See chapter Technical
data for scope of use.
1. Measure
2. Touch screen
3. Back
4. Home
5. Measure
6. Recents
7. Camera
8. USB port protection lid
9. USB port
10. ON/OFF
Home screen
1. Status bar
2. Side menu
3. Reality Capture
4. Laser
5. Sketch & Document
6. New Project
7. Organiser
Leica BLK3D 2
Technical data
Te c h n ica lda ta
Distance measurement (ISO 163331-1):
Accuracy with favourable conditions: * ± 1.0 mm / 0.04 in ***
Accuracy with unfavourable conditions: ** ± 2.0 mm / 0.08 in ***
Range with favourable conditions: * 250 m / 820 ft
Range with unfavourable conditions: **** 120 m / 394 ft
Smallest unit displayed: 0.1 mm / 1/32 in
X-Range Power Technology™: yes
Ø laser point at distances: 6 /30 / 60 mm (10 / 50 / 100 m)
Tilt measurement:
Measuring tolerance to laser beam: ***** ± 0.2°
Measuring tolerance to housing: ***** ± 0.2°
Range: 36
* applies for 100 % target reflectivity (white painted wall), low background illumination, 25 ºC
** applies for 10 to 100 % target reflectivity, high background illumination, - 10 ºC to + 50 ºC
*** Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m, to 0.20 mm/m between 30 m to
100 m and to 0.30 mm/m for distances above 100 m
**** applies for 100 % target reflectivity, background illumination of approximately 30'000 lux
***** after user calibration. Additional angle related deviation of +/- 0.01° per degree up to +/-45° in each quadrant.
Leica BLK3D 3
Technical data
P2P measurement with DST 360 (optional):
Working range vertical sensor: -64° to > 90°
Accuracy vertical sensor up to: +/- 0.
Working range horizontal sensor: 36
Accuracy horizontal sensor up to: +/- 0.
Tolerance P2P function at distances
(combination of sensors and distance measuring) approx.:
+/- 2 mm / 2 m
+/- 5 mm / 5 m
+/- 10 mm /10 m
Levelling range: +/- 5°
General:
Dimensions (H x W x D): 180.6 x 77.6 x 27.1 mm (7.11 x 3.06 x 1.07 in)
Weight (with rechargeable battery): 480 g / 17 oz
Temperature range: Storage: -25 to 60 °C / -13 to 140 °F
Operation: -10 to 50 °C / 14 to 122 °F
Charging: 0 to 40 °C / 32 to 104 °F
Tripod adapter: supports 1/4-20 UNC screw adapters
Leica BLK3D 4
Technical data
Technology:
Operating system: Android 7 (Nougat)
Processor (with integrated GPU): Snapdragon 820 QuadCore (2.2 GHz)
RAM Memory: 4 GB
Real-time processor: STM32F446
Screen: 5.0" IPS, HD 720x1280 LCD capacitive multi-touch screen, chemically strengthened, brightness: 450 cd/m2
Stereo camera: Pixels: 2 x 10 MP (15.8 cm diagonal base line)
Field of view: 80°
Focal length: 4.0 mm (22 mm in 35 mm equiv. in 1:1)
Aperture: F3.0
DISTO™ camera: Pixels: 2 MP
Field of view: 14°
I/O: USB Type-C 1.0 for data transfer and charging (water-resistant), integrated speaker and microphone
Keyboard: Three physical buttons (Power, DIST, Camera), four touch buttons (Back, Home, Recents, DIST)
Additional sensors: Compass, 3D accelerometer and 3D gyroscope
Laser class: 2
Laser type: 635 nm, < 1 mW
Storage:
Internal storage: 64 GB
Single shots: 14000 pictures
Multi shots: 5000 pictures
Leica BLK3D 5
Technical data
Communication:
Bluetooth® Smart: Bluetooth v4.1 and v2.1
Radiated power: 1.78 mW (BLE)
Radiated power: 10.00 mW (BT classic)
Frequency: 2402-2480 MHz
WLAN: Standard: 802.11 b/g/n
Radiated power: 6.31 mW
Frequency: 2412-2462 MHz
GPS: A-GPS and GLONASS
Power Management:
Battery: Rechargeable battery pack Li-Ion (3.80 V, 3880 mAh, 14.7 Wh) (included)
Power Management: AC adaptor (input: 100-240 V AC) (included)
External charger (input: 100-240 V AC) (optional)
Charge time: < 3.5 h (with AC adaptor)
< 5 h (with optional external charger)
Operating time: Typical capture*: 4 h / 220 multi-shot captures
Continuous capture*: 2.5 h / 1000 single-shot captures
Laser measurements: 6.5 h / 9500 laser measurements
Auto power off: 3 h
* Wi-Fi, Bluetooth® off, flash off, screen luminosity 50 %
Leica BLK3D 6
Instrument Set-up
Ins trume n tSet-up
Introduction
The safety instructions (see Safety
Instructions) and the user manual
should be read through carefully
before the product is used for the
first time.
The person responsible for the
product must ensure that all users
understand these directions and
adhere to them.
The symbols used have the following
meanings:
WARNING
Indicates a potentially hazardous situation
or an unintended use which, if not avoided,
will result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation
or an unintended use which, if not avoided,
may result in minor injury and/or appre-
ciable material, financial and envir-
onmental damage.
Important paragraphs which must
be adhered to in practice as they
enable the product to be used in a
technically correct and efficient man-
ner.
Charging Li-Ion battery
Charge batteries when battery icon
in status bar is flashing and before
using it for the first time. While char-
ging, the device may heat up. This is
normal and should not affect the
device’s lifespan or performance. If
the battery gets hotter than 40°C /
104°F, the charger stops. At a
recommended storage temperature
of -20°C to +30°C (-4°F to +86°F),
batteries containing a 50% to 100%
charge can be stored up to 1 year.
After this storage period the bat-
teries must be recharged. To save
energy, unplug the charger when not
in use.
CAUTION
Connecting the charger improperly may
cause serious damage to the device. Any
damage caused by misuse is not covered
by the warranty. Use only Leica-approved
chargers, batteries, and cables. Unap-
proved chargers or cables can cause the
battery to explode or damage the device.
Charge Li-Ion battery by USB port
on the device
Use the provided USB-C cable to charge
the BLK3D. Open the lid (1) and plug the
cable into the port of the device (2). Plug
the end of the USB-C cable into one of the
provided adaptors. Select the appropriate
one for your country. The device can also
be charged connecting the USB-C cable to
the computer, but this takes more time. If
the device is connected to the computer
via USB cable, you can download and
upload data. During charging, the device
cannot be used for measuring or acquiring
images.
Charge Li-Ion battery by USB char-
ger (optional)
Remove battery cover (1) by opening the
slider (2) from left to right. Remove battery
(3) and place it into charger (4). Insert the
USB cable into the port (5). Plug the char-
ger into an electrical socket. Charging is
completed when indicator light (6) turns
green.
Leica BLK3D 7
Instrument Set-up
Switching ON/OFF
Switching ON
Press ON/OFF button (1) to switch device
ON.
Switching OFF
Press ON/OFF button (1) for at least 2
seconds to switch device OFF.
Update
Connect the BLK3D to the internet via WiFi
to get the latest updates.
Using the touch screen
It is recommended to use fingers on
the touchscreen. Do not allow the
touch screen to come into contact
with other electrical devices. Elec-
trostatic discharges can cause the
touch screen to malfunction. Do not
allow the touch screen to get in con-
tact with water. The touch screen
may malfunction in humid conditions
or when exposed to water. To avoid
damaging the touch screen, do not
tap it with anything sharp or do not
apply excessive pressure to it with
your fingertips.
Tap
Tap on the display to open an application or
to make a selection.
Drag
Touch and hold object and drag it to the tar-
get position.
Double tap
Double tap on image to zoom it. Double tap
again to return.
Spread and pinch
Spread two fingers apart on image to
zoom. Pinch to zoom out.
Swipe
Swipe from left to right on the screen to
scroll side Menu. Swipe downwards to
scroll through options.
Leica BLK3D 8
Instrument Set-up
Activation
Select language for operating system.
Copy your data from another device or set
up as new.
Connect to a WiFi network. Protect your device with a PIN or a pass-
word (optional).
Leica BLK3D 9
Instrument Set-up
Settings
Select “Settings” menu.
Enter user data. Select measurement unit. Select language.
Leica BLK3D 10
Reality Capture
Rea lityCa p ture
1. Take photo
1
Select "Reality Capture" function.
2
Choose between different settings:
Timer: set a time delay for the
photo acquisition.
Grid: show grid lines on display for
better orientation.
Flash: set the flash ON/OFF.
Cancel: cancel last operation and
go back to home screen.
Menu: show menu for main nav-
igation.
3
Take a photo of the objects you want
to measure.
11
Leica BLK3D
4
To increase measurement accuracy
take an additional photo from a slightly
other perspective.
5
Review photos. Press "Remove" to
delete unwanted photos and "Keep" to
exit Review mode.
6
Go to Measure mode (see 2. Measure
distances in photo).
New: Cancel and create new "Real-
ity Capture" scene.
Reality Capture
2. Measure distances in photo
1
Select "Distance". Place fingers on the
edges of the object you want to meas-
ure. Spread fingers apart to enlarge the
object.
2
Tap a point on photo to start measuring
process.
Snap: Automatic snap to edges in
photo (activated by default).
Delete: delete selected measuring
point/line.
Undo: erase last operation.
3
Tap the second point. The measured
distance is automatically shown above
the line.
4
Tap on any measured point again to
activate Precise mode.
Leica BLK3D 12
5
Drag and spread to precisely center
the point you want to measure in the
hair cross.
Done: confirm measuring point pos-
ition.
Next: jump the next measuring
point for precise point selection.
6
Select Tools to add Tags, Rename or
Delete scene, Move scene to a project
(see Organiser), measure distances
with Laser (see Laser).
7
Select a line and measure the distance
with Laser. Laser measurement is
shown in brackets (see Laser).
8
Choose different options:
New: exits Measure mode to take
a new photo.
Export: export the scene in JPG or
PDF format.
Reality Capture
3. Measure areas in photo
1
Select "Area". Place fingers on the
edges of the object you want to meas-
ure. Spread fingers apart to enlarge the
object.
2
Tap a point on photo to start measuring
process.
Snap: Automatic snap to edges in
photo (activated by default).
Delete: delete selected measuring
point/line.
Undo: erase last operation.
3
Tap on next measuring points to com-
plete the area. Tap on any measured
point again to activate Precise mode.
Define more points to complete the
area. Tap on any point to activate Pre-
cise mode.
4
Drag and spread to precisely center
the point you want to measure in the
hair cross.
Done: confirm measuring point pos-
ition.
Next: jump the next measuring
point for precise point selection.
Leica BLK3D 13
5
Select Tools to add Tags, Rename or
Delete scene, Move scene to a project
(see Organiser), measure distances
with Laser (see Laser).
6
Select a line and measure the distance
with Laser. Laser measurement is
shown in brackets (see Laser).
7
Choose different options:
New: exits Measure mode to take
a new photo.
Export: export the scene in JPG or
PDF format.
Laser
Laser
Distance
14
Leica BLK3D
1
Select "Laser" function.
2
Adjust measuring reference:
Back: Distance is measured from the bot-
tom of the device (default setting).
Front: Distance is measured from the top
of the device.
Corner adaptor: Distance is measured
from the corner adapter (optional).
3
Select "Distance" from "Tools". Aim
laser at the target.
4
Press "Measure" button (see
Overview). Measured distance is
shown at the bottom of the screen.
5
Select "Tools" to choose between dif-
ferent measurements (Distance,
Smart Horizontal, Area and Volume)
and export measurement into a PDF
report.
6
Select "Calc" and choose between
"Add" and "Subtract". Take another
Distance measurement to Add/Sub-
tract to/from the previous one.
7
Swipe right to left to delete a single
measurement, or select "Clear" to can-
cel the measurement list.
Laser
Smart Horizontal
1
Select "Smart Horizontal" from "Tools".
Adjust measure reference if needed.
2
Aim active laser at target. Measure
with "Measure" button.
3
Vertical and horizontal distances are
calculated.
Tracking
Leica BLK3D 15
1
Press or "Measure" button for 2
seconds to activate tracking mode.
2
Press or "Measure" button again to fin-
ish the measurement.
Laser
Area
1
Select "Area" from "Tools". Adjust
measure reference if needed.
2
Measure two distances (length and
width) with "Measure" button.
3
Circumference and Area are auto-
matically calculated.
Volume
Leica BLK3D 16
1
Select "Volue" from "Tools". Adjust
measure reference if needed.
2
Measure three distances (length, width
and height) with "Measure" button.
3
Area, Wall Area, Circumference and
Volume are automatically calculated.
Sketch & Document
Sk e tch &Do c u me n t
Sketch Plan (Advanced)
17
Leica BLK3D
1
Select "Sketch Plan" function from
"Sketch & Document" menu.
2
Select "Line" or "Area" and draw by
dragging or tapping.
3
Select a line and press "Laser" to meas-
ure the length.
4
The sketch is automatically scaled.
Calculated values are in brackets.
5
Alternatively select a line and press
“Enter” to add length.
6
Select a line and press "Opening" to
add doors or windows.
7
Drag the opening to move it or select
the distance from the wall and meas-
ure it.
8
Select opening and press "Modify" to
change type and enter width and
height.
Sketch & Document
9
Switch to "3D" mode. A room height
can be entered.
10
Switch to "Document" and select an
empty placeholder to add Reality Cap-
ture scenes.
11
Select a placeholder to review the
scenes. Press the scene preview to
open it.
12
Select a placeholder to "Delete" or
"Add" Reality Capture scenes.
Leica BLK3D 18
Sketch & Document
Smart Room (Advanced)
1
Select "Smart Room" function from
"Sketch & Document" menu.
2
Keep screen oriented away from the
wall while measuring.
3
Measure room clockwise/anti-clock-
wise. Reverse measurements can be
taken.
4
Room Height can be measured any-
time.
Leica BLK3D 19
5
All measured values are displayed.
After the last measurement press "Fin-
ish".
6
The floorplan can be modified in
"Sketch" mode (see Sketch Plan).
Sketch & Document
Measure Plan (Advanced)
1
Connect BLK3D to Leica DST 360
adapter.
2
Select “Measure Plan” function from
“Sketch & Document” menu.
3
Measure lines, areas or points. Follow
on-screen instructions.
Measure Facade (Advanced)
Leica BLK3D 20
1
Connect BLK3D to Leica DST 360
adapter.
2
Select “Measure Facade” function
from “Sketch & Document” menu.
3
Measure lines, areas or points on a
facade. Follow on-screen instructions.
Organiser
Orga n ise r
1
Select "Organiser" function.
2
All the sketches and scenes are stored
in four categories:
1. All
2. Projects
3. Scenes
4. Plans
3
Open the category "All". All the plans,
Reality Capture scenes and projects
are stored.
4
Use the "Select" button to select an
item. Different actions are available:
Export, Move to Project, Rename, Tag
and Delete.
21
Leica BLK3D
5
Open the category "Projects". Press
the "Project" button to create a new Pro-
ject folder. Plans and scenes can be
moved in project folders.
6
Open the category "Scenes". All the
Reality Capture scenes are stored.
Press "RC" button to add a new scene.
7
Open the category "Plans". All the
plans, including plans with scenes
attached, are stored.
8
Press "S&D" button to add a new plan.
Care
Care
lClean the device with a damp, soft cloth.
lNever immerse the device in water.
lNever use aggressive cleaning agents or
solvents.
Leica BLK3D 22
Warranty
Warran ty
International Limited Warranty
The Leica BLK3D comes with a two year warranty from
Leica Geosystems AG. To receive an additional year war-
ranty, the product must be registered on our website at
http://myworld.leica-geosystems.com within eight
weeks of the purchase date.
If the product is not registered, our two year warranty
applies.
More detailed information about the International Limited
Warranty can be found on the internet at: www.leica-geo-
systems.com/internationalwarranty.
Leica BLK3D 23
Safety instructions
Sa fety ins truc tion s
The person responsible for the instrument must
ensure that all users understand these directions
and adhere to them. The product is permitted to
use for skilled persons only.
Symbols used
The symbols used have the following meanings:
WARNING
Indicates a potentially hazardous situation or an unin-
tended use which, if not avoided, will result in death or
serious injury.
CAUTION
Indicates a potentially hazardous situation or an unin-
tended use which, if not avoided, may result in minor
injury and/or appreciable material, financial and envir-
onmental damage.
Important paragraphs which must be adhered to in
practice as they enable the product to be used in a
technically correct and efficient manner.
Permitted use
lCapture interactive images
lMeasure in interactive images
lMeasure distances
lTilt measurement
lPoint to point measurement
lData transfer with Bluetooth®/WLAN
l2D/3D CAD export
Leica BLK3D 24
Safety instructions
Prohibited use
lUsing the device for the first time without read-
ing instructions
lUsing the device outside the stated limits of
use (see section Limits of use)
lDeactivating safety systems and removing
explanatory and hazard labels
lOpening of the equipment by using tools
(screwdrivers, etc.)
lUsing not approved accessories from other
manufacturers
lDeliberate dazzling of third parties; also in the
dark
lUsing the device in surveying sites with inad-
equate safeguards
lDeliberate or irresponsible behaviour on scaf-
folding, when using ladders, when measuring
near machines which are running or near parts
of machines or installations which are unpro-
tected
lAiming directly in the sun
Hazards in use
WARNING
Watch out for erroneous measurements if the instrument
is defective or if it has been dropped or has been misused
or modified. Carry out periodic test measurements. Par-
ticularly after the instrument has been subject to abnor-
mal use, and before, during and after important
measurements.
CAUTION
Never attempt to repair the product yourself. In case of
damage, contact a local dealer.
WARNING
Changes or modifications not expressly approved could
void the user´s authority to operate the equipment.
CAUTION
Only use chargers recommended by the manufacturer to
charge the batteries.
Limits of use
Refer to section Technical data. The device is
designed for use in areas permanently habitable by
humans. Do not use the product in explosion haz-
ardous areas or in aggressive environments.
Leica BLK3D 25
Safety instructions
Areas of responsibility
Responsibilities of the manufacturer of the ori-
ginal equipment:
Leica Geosystems AG
Heinrich-Wild-Strasse
CH-9435 Heerbrugg
Internet: www.leica-geosystems.com
The company above is responsible for supplying the
product, including the User Manual in a completely safe
condition.
The company above is not responsible for third party
accessories.
Responsibilities of the person in charge of the
instrument:
lTo understand the safety instructions on the
product and the instructions in the User
Manual.
lTo be familiar with local safety regulations relat-
ing to accident prevention.
lAlways prevent access to the product by unau-
thorised personnel.
Disposal
CAUTION
Flat batteries must not be disposed of with household
waste. Care for the environment and take them to the col-
lection points provided in accordance with national or
local regulations.
The product must not be disposed with household
waste. Dispose of the product appropriately in
accordance with the national regulations in force in
your country. Adhere to the national and country
specific regulations.
Product specific treatment and waste management can
be downloaded from our homepage.
Electromagnetic Compatibility
(EMC)
WARNING
The device conforms to the most stringent requirements
of the relevant standards and regulations. However, the
possibility of causing interference in other devices can-
not be totally excluded.
Leica BLK3D 26
Safety instructions
FCC statement (applicable in U.S.)
This equipment has been tested and found to comply
with the limits for a Class B digital instrument, pursuant
to part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful inter-
ference in a residential installation. This equipment gen-
erates, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio com-
munications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television recep-
tion, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
lReorient or relocate the receiving antenna
lIncrease the separation between the equip-
ment and the receiver
lConnect the equipment into an outlet on a cir-
cuit different from that to which the receiver is
connected
lConsult the dealer or an experienced radio/TV
technician for help
This device complies with part 15 of the FCC rules. Oper-
ation is subjected to the following two conditions:
lThis device may not cause harmful inter-
ference, and
lthis device must accept any interference
received, including interference that may
cause undesired operation.
FCC Radiation Exposure Statement
The radiated rf output power of the instrument is below
the FCC radio frequency exposure limits for portable
devices according to KDB 447498.
ISED Statement (applicable in
Canada)
This device complies with Industry Canada's license-
exempt RSSs. Operation is subject to the following two
conditions:
lThis device may not cause harmful inter-
ference, and
lthis device must accept any interference,
including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie
Canada applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux conditions
suivantes :
ll’appareil ne doit pas produire de brouillage;
ll’appareil doit accepter tout brouillage radi-
lectrique subi, même si le brouillage est sus-
ceptible d’en compromettre le fonctionnement.
Radio Frequency (RF) Exposure Compliance
Statement
The radiated rf output power of the instrument is below
the Health Canada's Safety Code 6 exclusion limit for
portable devices (radiated element separation distance
between the radiating element and user and/or bystander
is below 20 cm).
Japanese Radio Law and Japanese
Telecommunications Business Law
Compliance
This device is granted pursuant to the Japanese Radio
Law (電波法) and the Japanese Telecommunications
Business Law (電気通信事業法).
Leica BLK3D 27
Safety instructions
Regulatory
Regulatory information, certification, and compliance
marks are available on BLK3D. Go to Android Settings >
About phone > Regulatory labels.
Use of the product with Bluetooth®
WARNING
Electromagnetic radiation can cause disturbances in
other equipment, in installations (e.g. medical ones such
as pacemakers or hearing aids) and in aircraft. It can also
affect humans and animals.
Precautions:
Although this product conforms to the most stringent
standards and regulations, the possibility of harm to
people and animals cannot be totally excluded.
lDo not use the product near petrol stations,
chemical plants, in areas with a potentially
explosive atmosphere and where blasting
takes place.
lDo not use the product near medical equip-
ment.
lDo not use the product in airplanes.
lDo not use the product near your body for
extended periods.
Leica BLK3D 28
Safety instructions
Laser classification
The device produces visible laser beams, which are emit-
ted from the instrument: It is a Class 2 laser product in
accordance with:
lIEC60825-1 : 2014 „Radiation safety of laser
products“
Laser Class 2 products:
Do not stare into the laser beam or direct it towards other
people unnecessarily. Eye protection is normally
afforded by aversion responses including the blink reflex.
WARNING
Looking directly into the beam with optical aids (e.g. bin-
oculars, telescopes) can be hazardous.
CAUTION
Looking into the laser beam may be hazardous to the
eyes. Don't dazzle other individuals. Pay particular atten-
tion to the direction of the laser beam when remotely oper-
ating the product via an app or software. A measurement
could be triggered at any time.
Wavelength
655 nm
Maximum radiant output power for classification
0.95 mW
Pulse duration
400 ps
Pulse repetition frequency
320 MHz
Beam divergence
0.16 x 0.6 mrad
Labelling
Subject to change (drawings, descriptions and technical
data) without prior notice.
Leica BLK3D 29

RFF-IIS01 User Man

Leica BLK3D
Overview 2
Technical data 3
Instrument Set-up 7
Reality Capture 11
Laser 14
Sketch & Document 17
Organiser 21
Care 22
Warranty 23
Safety instructions 24
Leica BLK3D 1
Overview
Ove rview
Components
The Leica BLK3D is a remote meas-
urement tool with a class 2 laser. It
enables to measure distances within a pic-
ture at any time. See chapter Technical
data for scope of use.
1. Measure
2. Touch screen
3. Back
4. Home
5. Measure
6. Recents
7. Camera
8. USB port protection lid
9. USB port
10. ON/OFF
Home screen
1. Status bar
2. Side menu
3. Reality Capture
4. Laser
5. Sketch & Document
6. New Project
7. Organiser
Leica BLK3D 2
Technical data
Te c h n ica lda ta
Distance measurement (ISO 163331-1):
Accuracy with favourable conditions: * ± 1.0 mm / 0.04 in ***
Accuracy with unfavourable conditions: ** ± 2.0 mm / 0.08 in ***
Range with favourable conditions: * 250 m / 820 ft
Range with unfavourable conditions: **** 120 m / 394 ft
Smallest unit displayed: 0.1 mm / 1/32 in
X-Range Power Technology™: yes
Ø laser point at distances: 6 /30 / 60 mm (10 / 50 / 100 m)
Tilt measurement:
Measuring tolerance to laser beam: ***** ± 0.2°
Measuring tolerance to housing: ***** ± 0.2°
Range: 36
* applies for 100 % target reflectivity (white painted wall), low background illumination, 25 ºC
** applies for 10 to 100 % target reflectivity, high background illumination, - 10 ºC to + 50 ºC
*** Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m, to 0.20 mm/m between 30 m to
100 m and to 0.30 mm/m for distances above 100 m
**** applies for 100 % target reflectivity, background illumination of approximately 30'000 lux
***** after user calibration. Additional angle related deviation of +/- 0.01° per degree up to +/-45° in each quadrant.
Leica BLK3D 3
Technical data
P2P measurement with DST 360 (optional):
Working range vertical sensor: -64° to > 90°
Accuracy vertical sensor up to: +/- 0.
Working range horizontal sensor: 36
Accuracy horizontal sensor up to: +/- 0.
Tolerance P2P function at distances
(combination of sensors and distance measuring) approx.:
+/- 2 mm / 2 m
+/- 5 mm / 5 m
+/- 10 mm /10 m
Levelling range: +/- 5°
General:
Dimensions (H x W x D): 180.6 x 77.6 x 27.1 mm (7.11 x 3.06 x 1.07 in)
Weight (with rechargeable battery): 480 g / 17 oz
Temperature range: Storage: -25 to 60 °C / -13 to 140 °F
Operation: -10 to 50 °C / 14 to 122 °F
Charging: 0 to 40 °C / 32 to 104 °F
Tripod adapter: supports 1/4-20 UNC screw adapters
Leica BLK3D 4
Technical data
Technology:
Operating system: Android 7 (Nougat)
Processor (with integrated GPU): Snapdragon 820 QuadCore (2.2 GHz)
RAM Memory: 4 GB
Real-time processor: STM32F446
Screen: 5.0" IPS, HD 720x1280 LCD capacitive multi-touch screen, chemically strengthened, brightness: 450 cd/m2
Stereo camera: Pixels: 2 x 10 MP (15.8 cm diagonal base line)
Field of view: 80°
Focal length: 4.0 mm (22 mm in 35 mm equiv. in 1:1)
Aperture: F3.0
DISTO™ camera: Pixels: 2 MP
Field of view: 14°
I/O: USB Type-C 1.0 for data transfer and charging (water-resistant), integrated speaker and microphone
Keyboard: Three physical buttons (Power, DIST, Camera), four touch buttons (Back, Home, Recents, DIST)
Additional sensors: Compass, 3D accelerometer and 3D gyroscope
Laser class: 2
Laser type: 635 nm, < 1 mW
Storage:
Internal storage: 64 GB
Single shots: 14000 pictures
Multi shots: 5000 pictures
Leica BLK3D 5
Technical data
Communication:
Bluetooth® Smart: Bluetooth v4.1 and v2.1
Radiated power: 1.78 mW (BLE)
Radiated power: 10.00 mW (BT classic)
Frequency: 2402-2480 MHz
WLAN: Standard: 802.11 b/g/n
Radiated power: 6.31 mW
Frequency: 2412-2462 MHz
GPS: A-GPS and GLONASS
Power Management:
Battery: Rechargeable battery pack Li-Ion (3.80 V, 3880 mAh, 14.7 Wh) (included)
Power Management: AC adaptor (input: 100-240 V AC) (included)
External charger (input: 100-240 V AC) (optional)
Charge time: < 3.5 h (with AC adaptor)
< 5 h (with optional external charger)
Operating time: Typical capture*: 4 h / 220 multi-shot captures
Continuous capture*: 2.5 h / 1000 single-shot captures
Laser measurements: 6.5 h / 9500 laser measurements
Auto power off: 3 h
* Wi-Fi, Bluetooth® off, flash off, screen luminosity 50 %
Leica BLK3D 6
Instrument Set-up
Ins trume n tSet-up
Introduction
The safety instructions (see Safety
Instructions) and the user manual
should be read through carefully
before the product is used for the
first time.
The person responsible for the
product must ensure that all users
understand these directions and
adhere to them.
The symbols used have the following
meanings:
WARNING
Indicates a potentially hazardous situation
or an unintended use which, if not avoided,
will result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation
or an unintended use which, if not avoided,
may result in minor injury and/or appre-
ciable material, financial and envir-
onmental damage.
Important paragraphs which must
be adhered to in practice as they
enable the product to be used in a
technically correct and efficient man-
ner.
Charging Li-Ion battery
Charge batteries when battery icon
in status bar is flashing and before
using it for the first time. While char-
ging, the device may heat up. This is
normal and should not affect the
device’s lifespan or performance. If
the battery gets hotter than 40°C /
104°F, the charger stops. At a
recommended storage temperature
of -20°C to +30°C (-4°F to +86°F),
batteries containing a 50% to 100%
charge can be stored up to 1 year.
After this storage period the bat-
teries must be recharged. To save
energy, unplug the charger when not
in use.
CAUTION
Connecting the charger improperly may
cause serious damage to the device. Any
damage caused by misuse is not covered
by the warranty. Use only Leica-approved
chargers, batteries, and cables. Unap-
proved chargers or cables can cause the
battery to explode or damage the device.
Charge Li-Ion battery by USB port
on the device
Use the provided USB-C cable to charge
the BLK3D. Open the lid (1) and plug the
cable into the port of the device (2). Plug
the end of the USB-C cable into one of the
provided adaptors. Select the appropriate
one for your country. The device can also
be charged connecting the USB-C cable to
the computer, but this takes more time. If
the device is connected to the computer
via USB cable, you can download and
upload data. During charging, the device
cannot be used for measuring or acquiring
images.
Charge Li-Ion battery by USB char-
ger (optional)
Remove battery cover (1) by opening the
slider (2) from left to right. Remove battery
(3) and place it into charger (4). Insert the
USB cable into the port (5). Plug the char-
ger into an electrical socket. Charging is
completed when indicator light (6) turns
green.
Leica BLK3D 7
Instrument Set-up
Switching ON/OFF
Switching ON
Press ON/OFF button (1) to switch device
ON.
Switching OFF
Press ON/OFF button (1) for at least 2
seconds to switch device OFF.
Update
Connect the BLK3D to the internet via WiFi
to get the latest updates.
Using the touch screen
It is recommended to use fingers on
the touchscreen. Do not allow the
touch screen to come into contact
with other electrical devices. Elec-
trostatic discharges can cause the
touch screen to malfunction. Do not
allow the touch screen to get in con-
tact with water. The touch screen
may malfunction in humid conditions
or when exposed to water. To avoid
damaging the touch screen, do not
tap it with anything sharp or do not
apply excessive pressure to it with
your fingertips.
Tap
Tap on the display to open an application or
to make a selection.
Drag
Touch and hold object and drag it to the tar-
get position.
Double tap
Double tap on image to zoom it. Double tap
again to return.
Spread and pinch
Spread two fingers apart on image to
zoom. Pinch to zoom out.
Swipe
Swipe from left to right on the screen to
scroll side Menu. Swipe downwards to
scroll through options.
Leica BLK3D 8
Instrument Set-up
Activation
Select language for operating system.
Copy your data from another device or set
up as new.
Connect to a WiFi network. Protect your device with a PIN or a pass-
word (optional).
Leica BLK3D 9
Instrument Set-up
Settings
Select “Settings” menu.
Enter user data. Select measurement unit. Select language.
Leica BLK3D 10
Reality Capture
Rea lityCa p ture
1. Take photo
1
Select "Reality Capture" function.
2
Choose between different settings:
Timer: set a time delay for the
photo acquisition.
Grid: show grid lines on display for
better orientation.
Flash: set the flash ON/OFF.
Cancel: cancel last operation and
go back to home screen.
Menu: show menu for main nav-
igation.
3
Take a photo of the objects you want
to measure.
11
Leica BLK3D
4
To increase measurement accuracy
take an additional photo from a slightly
other perspective.
5
Review photos. Press "Remove" to
delete unwanted photos and "Keep" to
exit Review mode.
6
Go to Measure mode (see 2. Measure
distances in photo).
New: Cancel and create new "Real-
ity Capture" scene.
Reality Capture
2. Measure distances in photo
1
Select "Distance". Place fingers on the
edges of the object you want to meas-
ure. Spread fingers apart to enlarge the
object.
2
Tap a point on photo to start measuring
process.
Snap: Automatic snap to edges in
photo (activated by default).
Delete: delete selected measuring
point/line.
Undo: erase last operation.
3
Tap the second point. The measured
distance is automatically shown above
the line.
4
Tap on any measured point again to
activate Precise mode.
Leica BLK3D 12
5
Drag and spread to precisely center
the point you want to measure in the
hair cross.
Done: confirm measuring point pos-
ition.
Next: jump the next measuring
point for precise point selection.
6
Select Tools to add Tags, Rename or
Delete scene, Move scene to a project
(see Organiser), measure distances
with Laser (see Laser).
7
Select a line and measure the distance
with Laser. Laser measurement is
shown in brackets (see Laser).
8
Choose different options:
New: exits Measure mode to take
a new photo.
Export: export the scene in JPG or
PDF format.
Reality Capture
3. Measure areas in photo
1
Select "Area". Place fingers on the
edges of the object you want to meas-
ure. Spread fingers apart to enlarge the
object.
2
Tap a point on photo to start measuring
process.
Snap: Automatic snap to edges in
photo (activated by default).
Delete: delete selected measuring
point/line.
Undo: erase last operation.
3
Tap on next measuring points to com-
plete the area. Tap on any measured
point again to activate Precise mode.
Define more points to complete the
area. Tap on any point to activate Pre-
cise mode.
4
Drag and spread to precisely center
the point you want to measure in the
hair cross.
Done: confirm measuring point pos-
ition.
Next: jump the next measuring
point for precise point selection.
Leica BLK3D 13
5
Select Tools to add Tags, Rename or
Delete scene, Move scene to a project
(see Organiser), measure distances
with Laser (see Laser).
6
Select a line and measure the distance
with Laser. Laser measurement is
shown in brackets (see Laser).
7
Choose different options:
New: exits Measure mode to take
a new photo.
Export: export the scene in JPG or
PDF format.
Laser
Laser
Distance
14
Leica BLK3D
1
Select "Laser" function.
2
Adjust measuring reference:
Back: Distance is measured from the bot-
tom of the device (default setting).
Front: Distance is measured from the top
of the device.
Corner adaptor: Distance is measured
from the corner adapter (optional).
3
Select "Distance" from "Tools". Aim
laser at the target.
4
Press "Measure" button (see
Overview). Measured distance is
shown at the bottom of the screen.
5
Select "Tools" to choose between dif-
ferent measurements (Distance,
Smart Horizontal, Area and Volume)
and export measurement into a PDF
report.
6
Select "Calc" and choose between
"Add" and "Subtract". Take another
Distance measurement to Add/Sub-
tract to/from the previous one.
7
Swipe right to left to delete a single
measurement, or select "Clear" to can-
cel the measurement list.
Laser
Smart Horizontal
1
Select "Smart Horizontal" from "Tools".
Adjust measure reference if needed.
2
Aim active laser at target. Measure
with "Measure" button.
3
Vertical and horizontal distances are
calculated.
Tracking
Leica BLK3D 15
1
Press or "Measure" button for 2
seconds to activate tracking mode.
2
Press or "Measure" button again to fin-
ish the measurement.
Laser
Area
1
Select "Area" from "Tools". Adjust
measure reference if needed.
2
Measure two distances (length and
width) with "Measure" button.
3
Circumference and Area are auto-
matically calculated.
Volume
Leica BLK3D 16
1
Select "Volue" from "Tools". Adjust
measure reference if needed.
2
Measure three distances (length, width
and height) with "Measure" button.
3
Area, Wall Area, Circumference and
Volume are automatically calculated.
Sketch & Document
Sk e tch &Do c u me n t
Sketch Plan (Advanced)
17
Leica BLK3D
1
Select "Sketch Plan" function from
"Sketch & Document" menu.
2
Select "Line" or "Area" and draw by
dragging or tapping.
3
Select a line and press "Laser" to meas-
ure the length.
4
The sketch is automatically scaled.
Calculated values are in brackets.
5
Alternatively select a line and press
“Enter” to add length.
6
Select a line and press "Opening" to
add doors or windows.
7
Drag the opening to move it or select
the distance from the wall and meas-
ure it.
8
Select opening and press "Modify" to
change type and enter width and
height.
Sketch & Document
9
Switch to "3D" mode. A room height
can be entered.
10
Switch to "Document" and select an
empty placeholder to add Reality Cap-
ture scenes.
11
Select a placeholder to review the
scenes. Press the scene preview to
open it.
12
Select a placeholder to "Delete" or
"Add" Reality Capture scenes.
Leica BLK3D 18
Sketch & Document
Smart Room (Advanced)
1
Select "Smart Room" function from
"Sketch & Document" menu.
2
Keep screen oriented away from the
wall while measuring.
3
Measure room clockwise/anti-clock-
wise. Reverse measurements can be
taken.
4
Room Height can be measured any-
time.
Leica BLK3D 19
5
All measured values are displayed.
After the last measurement press "Fin-
ish".
6
The floorplan can be modified in
"Sketch" mode (see Sketch Plan).
Sketch & Document
Measure Plan (Advanced)
1
Connect BLK3D to Leica DST 360
adapter.
2
Select “Measure Plan” function from
“Sketch & Document” menu.
3
Measure lines, areas or points. Follow
on-screen instructions.
Measure Facade (Advanced)
Leica BLK3D 20
1
Connect BLK3D to Leica DST 360
adapter.
2
Select “Measure Facade” function
from “Sketch & Document” menu.
3
Measure lines, areas or points on a
facade. Follow on-screen instructions.
Organiser
Orga n ise r
1
Select "Organiser" function.
2
All the sketches and scenes are stored
in four categories:
1. All
2. Projects
3. Scenes
4. Plans
3
Open the category "All". All the plans,
Reality Capture scenes and projects
are stored.
4
Use the "Select" button to select an
item. Different actions are available:
Export, Move to Project, Rename, Tag
and Delete.
21
Leica BLK3D
5
Open the category "Projects". Press
the "Project" button to create a new Pro-
ject folder. Plans and scenes can be
moved in project folders.
6
Open the category "Scenes". All the
Reality Capture scenes are stored.
Press "RC" button to add a new scene.
7
Open the category "Plans". All the
plans, including plans with scenes
attached, are stored.
8
Press "S&D" button to add a new plan.
Care
Care
lClean the device with a damp, soft cloth.
lNever immerse the device in water.
lNever use aggressive cleaning agents or
solvents.
Leica BLK3D 22
Warranty
Warran ty
International Limited Warranty
The Leica BLK3D comes with a two year warranty from
Leica Geosystems AG. To receive an additional year war-
ranty, the product must be registered on our website at
http://myworld.leica-geosystems.com within eight
weeks of the purchase date.
If the product is not registered, our two year warranty
applies.
More detailed information about the International Limited
Warranty can be found on the internet at: www.leica-geo-
systems.com/internationalwarranty.
Leica BLK3D 23
Safety instructions
Sa fety ins truc tion s
The person responsible for the instrument must
ensure that all users understand these directions
and adhere to them. The product is permitted to
use for skilled persons only.
Symbols used
The symbols used have the following meanings:
WARNING
Indicates a potentially hazardous situation or an unin-
tended use which, if not avoided, will result in death or
serious injury.
CAUTION
Indicates a potentially hazardous situation or an unin-
tended use which, if not avoided, may result in minor
injury and/or appreciable material, financial and envir-
onmental damage.
Important paragraphs which must be adhered to in
practice as they enable the product to be used in a
technically correct and efficient manner.
Permitted use
lCapture interactive images
lMeasure in interactive images
lMeasure distances
lTilt measurement
lPoint to point measurement
lData transfer with Bluetooth®/WLAN
l2D/3D CAD export
Leica BLK3D 24
Safety instructions
Prohibited use
lUsing the device for the first time without read-
ing instructions
lUsing the device outside the stated limits of
use (see section Limits of use)
lDeactivating safety systems and removing
explanatory and hazard labels
lOpening of the equipment by using tools
(screwdrivers, etc.)
lUsing not approved accessories from other
manufacturers
lDeliberate dazzling of third parties; also in the
dark
lUsing the device in surveying sites with inad-
equate safeguards
lDeliberate or irresponsible behaviour on scaf-
folding, when using ladders, when measuring
near machines which are running or near parts
of machines or installations which are unpro-
tected
lAiming directly in the sun
Hazards in use
WARNING
Watch out for erroneous measurements if the instrument
is defective or if it has been dropped or has been misused
or modified. Carry out periodic test measurements. Par-
ticularly after the instrument has been subject to abnor-
mal use, and before, during and after important
measurements.
CAUTION
Never attempt to repair the product yourself. In case of
damage, contact a local dealer.
WARNING
Changes or modifications not expressly approved could
void the user´s authority to operate the equipment.
CAUTION
Only use chargers recommended by the manufacturer to
charge the batteries.
Limits of use
Refer to section Technical data. The device is
designed for use in areas permanently habitable by
humans. Do not use the product in explosion haz-
ardous areas or in aggressive environments.
Leica BLK3D 25
Safety instructions
Areas of responsibility
Responsibilities of the manufacturer of the ori-
ginal equipment:
Leica Geosystems AG
Heinrich-Wild-Strasse
CH-9435 Heerbrugg
Internet: www.leica-geosystems.com
The company above is responsible for supplying the
product, including the User Manual in a completely safe
condition.
The company above is not responsible for third party
accessories.
Responsibilities of the person in charge of the
instrument:
lTo understand the safety instructions on the
product and the instructions in the User
Manual.
lTo be familiar with local safety regulations relat-
ing to accident prevention.
lAlways prevent access to the product by unau-
thorised personnel.
Disposal
CAUTION
Flat batteries must not be disposed of with household
waste. Care for the environment and take them to the col-
lection points provided in accordance with national or
local regulations.
The product must not be disposed with household
waste. Dispose of the product appropriately in
accordance with the national regulations in force in
your country. Adhere to the national and country
specific regulations.
Product specific treatment and waste management can
be downloaded from our homepage.
Electromagnetic Compatibility
(EMC)
WARNING
The device conforms to the most stringent requirements
of the relevant standards and regulations. However, the
possibility of causing interference in other devices can-
not be totally excluded.
Leica BLK3D 26
Safety instructions
FCC statement (applicable in U.S.)
This equipment has been tested and found to comply
with the limits for a Class B digital instrument, pursuant
to part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful inter-
ference in a residential installation. This equipment gen-
erates, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio com-
munications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television recep-
tion, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
lReorient or relocate the receiving antenna
lIncrease the separation between the equip-
ment and the receiver
lConnect the equipment into an outlet on a cir-
cuit different from that to which the receiver is
connected
lConsult the dealer or an experienced radio/TV
technician for help
This device complies with part 15 of the FCC rules. Oper-
ation is subjected to the following two conditions:
lThis device may not cause harmful inter-
ference, and
lthis device must accept any interference
received, including interference that may
cause undesired operation.
FCC Radiation Exposure Statement
The radiated rf output power of the instrument is below
the FCC radio frequency exposure limits for portable
devices according to KDB 447498.
ISED Statement (applicable in
Canada)
This device complies with Industry Canada's license-
exempt RSSs. Operation is subject to the following two
conditions:
lThis device may not cause harmful inter-
ference, and
lthis device must accept any interference,
including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie
Canada applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux conditions
suivantes :
ll’appareil ne doit pas produire de brouillage;
ll’appareil doit accepter tout brouillage radi-
lectrique subi, même si le brouillage est sus-
ceptible d’en compromettre le fonctionnement.
Radio Frequency (RF) Exposure Compliance
Statement
The radiated rf output power of the instrument is below
the Health Canada's Safety Code 6 exclusion limit for
portable devices (radiated element separation distance
between the radiating element and user and/or bystander
is below 20 cm).
Japanese Radio Law and Japanese
Telecommunications Business Law
Compliance
This device is granted pursuant to the Japanese Radio
Law (電波法) and the Japanese Telecommunications
Business Law (電気通信事業法).
Leica BLK3D 27
Safety instructions
Regulatory
Regulatory information, certification, and compliance
marks are available on BLK3D. Go to Android Settings >
About phone > Regulatory labels.
Use of the product with Bluetooth®
WARNING
Electromagnetic radiation can cause disturbances in
other equipment, in installations (e.g. medical ones such
as pacemakers or hearing aids) and in aircraft. It can also
affect humans and animals.
Precautions:
Although this product conforms to the most stringent
standards and regulations, the possibility of harm to
people and animals cannot be totally excluded.
lDo not use the product near petrol stations,
chemical plants, in areas with a potentially
explosive atmosphere and where blasting
takes place.
lDo not use the product near medical equip-
ment.
lDo not use the product in airplanes.
lDo not use the product near your body for
extended periods.
Leica BLK3D 28
Safety instructions
Laser classification
The device produces visible laser beams, which are emit-
ted from the instrument: It is a Class 2 laser product in
accordance with:
lIEC60825-1 : 2014 „Radiation safety of laser
products“
Laser Class 2 products:
Do not stare into the laser beam or direct it towards other
people unnecessarily. Eye protection is normally
afforded by aversion responses including the blink reflex.
WARNING
Looking directly into the beam with optical aids (e.g. bin-
oculars, telescopes) can be hazardous.
CAUTION
Looking into the laser beam may be hazardous to the
eyes. Don't dazzle other individuals. Pay particular atten-
tion to the direction of the laser beam when remotely oper-
ating the product via an app or software. A measurement
could be triggered at any time.
Wavelength
655 nm
Maximum radiant output power for classification
0.95 mW
Pulse duration
400 ps
Pulse repetition frequency
320 MHz
Beam divergence
0.16 x 0.6 mrad
Labelling
Subject to change (drawings, descriptions and technical
data) without prior notice.
Leica BLK3D 29