Lelux Electronics 763T WIRELESS TEMPERATURE SENSOR WITH ALARM User Manual 763T

Lelux Electronics Ltd WIRELESS TEMPERATURE SENSOR WITH ALARM 763T

Users Manual

Download: Lelux Electronics 763T WIRELESS TEMPERATURE SENSOR WITH ALARM User Manual 763T
Mirror Download [FCC.gov]Lelux Electronics 763T WIRELESS TEMPERATURE SENSOR WITH ALARM User Manual 763T
Document ID1321993
Application IDZDuoPH5dqZm2CT/lxNd/AA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize48.79kB (609929 bits)
Date Submitted2010-08-04 00:00:00
Date Available2010-08-04 00:00:00
Creation Date2010-07-27 11:17:42
Producing SoftwareAdobe PDF library 7.77
Document Lastmod2010-07-28 11:47:48
Document Title763T
Document CreatorAdobe Illustrator CS2

INSTALLATION
1.Remove the screw from the battery compartment cover. (fig.1)
2.Install 3 "AAA" batteries (Not included) to the battery
compartment make sure install with correct polarity. (Fig. 1).
wait for 30 minutes again, if the temperature return normal sensor
will into standby mode; if the temperature still was less than or
equal to the cold temperature setting (13°C or 5°C) or greater than
or equal to the high temperature value (35°C), the alarm would
sound again for 45 seconds and sending wireless trigger signal.
(Cycle 3) ---- Wait 30 minutes again, when the temperature still not
return normal will stop alarm.
In alarming, you can turn alarm or turn power switch to off the
sensor.
BATTERY LOW INDICATION
(Fig. 1)
3.Replace the battery cover and screw.
4.Learning ID code to main unit
NOTE:
a.The wireless temperature sensor output RF signal compatible
trigger auto dialer (T015S, T016S, T055S, T056S, T018S,
T068S) and wireless outdoor siren (526L, 526F, 527SL) and
wireless alarm receiver(625RX) and wireless control AC socket (
422R, 688R) function, must learn ID code to main unit then use.
learn ID operation: First make auto dialer or wireless siren or AC
socket enter learning mode (refer the their own manual), then
turn alarm switch to OFF and press TEST button of local unit,
you will hear the sound of telling you learn ID code successfully.
b.After select a location, you should test the sensor transmitting
range before mount it permanently, turn local power switch to ON
and alarm switch to OFF, turn the CHIME switch to ON of T015S,
T016S main unit or press HOME button of T055S, T056S,
T018S, T068S, after 60 seconds, press “TEST” button of local
unit back, you will hear the main unit sounds “DING DONG”
chime if signal is received successfully, if not , change location is
required.
5.Mount the main unit at the desired location with anchors and
screw (included).
6.Using the double-side tapes (included) stick external temperature
detector on the desired location.
OPERATION
Select you want detect temperature 13°C (55.4 ºF) or 5°C (41ºF)
by switch. Turn power switch and alarm switch to ON, the unit will
into stand by mode. When temperature from normal down to
13°C/5°C (55.4ºF/41ºF) or from normal rise to 35°C (95ºF) will
send wireless trigger signal auto dialer and activate 45 seconds
(Cycle 1)
wait for 30 minutes, if the temperature return normal sensor will
into standby mode; if the temperature was less than or equal to the
cold temperature setting (13°C or 5°C) or greater than or equal to
the high temperature value (35°C), the alarm would sound again
for 45 seconds and sending wireless trigger signal. (Cycle 2)
wait for 30 minutes again, if the temperature return normal sensor
will into standby mode; if the temperature still was less than or
When battery goes lower, the BAT.LOW LED will flash, change a
new batteries immediately, to avoid the sensor might not detection
properly.
NOTE:
1. If the units will not be used for a long period, please remove all
of the batteries, otherwise, the batteries will leak and damage
the units.
2. Avoid mixing the old batteries and the new ones and do not put
them into the fire in case of exploding.
Warning:
Changes or modifications to this unit not expressly approved by
the party responsible for compliance will void the user's authority to
operate the equipment. Any change to the equipment will void FCC
grant.
This equipment has been tested and found to comply with the
limits for a Class C digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for
help.
-2-
-1-
size: 95x190mm
p/n: 610-763XX-000R
white paper print black words
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation
WIRELESS TEMPERATURE
SENSOR WITH ALARM
MODEL:763T
BAT.LOW
OWNER'S MANUAL
-3-
610-763TX-000R

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Format                          : application/pdf
Title                           : 763T
Creator Tool                    : Adobe Illustrator CS2
Create Date                     : 2010:07:27 11:17:42+08:00
Modify Date                     : 2010:07:28 11:47:48+08:00
Metadata Date                   : 2010:07:28 11:47:48+08:00
Thumbnail Width                 : 136
Thumbnail Height                : 256
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 11627 bytes, use -b option to extract)
Document ID                     : uuid:4F7A40812D99DF11AAE3D29A27B07FE9
Instance ID                     : uuid:089daecd-4edd-43c3-8809-57cd993024f8
Derived From Document Name      : uuid:682d97dc-9927-11df-aedd-000393d1df40
Derived From Instance ID        : uuid:efff2817-a748-469e-83da-c88d3fb97d5f
Derived From Document ID        : xmp.did:E85A9FC45E82DF118DDDD8D5E4EB39E5
Derived From Rendition Class    : proof:pdf
Startup Profile                 : Print
Type                            : Document
Producer                        : Adobe PDF library 7.77
Page Count                      : 1
Container Version               : 9
Creator Version                 : 12
Creator                         : Adobe Illustrator(R) 12.0
For                             : User, -
Bounding Box                    : -94 -224 575 1056
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NS3-763T

Navigation menu