Lelux Electronics LELUXT018R WIRELESS SECURITY ALARM SYSTEM User Manual T018 SYSTEM

Lelux Electronics Ltd WIRELESS SECURITY ALARM SYSTEM T018 SYSTEM

User Manual Part 4

Download: Lelux Electronics LELUXT018R WIRELESS SECURITY ALARM SYSTEM User Manual T018 SYSTEM
Mirror Download [FCC.gov]Lelux Electronics LELUXT018R WIRELESS SECURITY ALARM SYSTEM User Manual T018 SYSTEM
Document ID738149
Application ID49y6VHx97DVeNPLKgiX2pQ==
Document DescriptionUser Manual Part 4
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize276.17kB (3452168 bits)
Date Submitted2006-12-13 00:00:00
Date Available2006-12-13 00:00:00
Creation Date2006-11-08 09:59:32
Producing SoftwareAdobe PDF library 7.77
Document Lastmod2006-12-13 13:08:21
Document TitleT018 SYSTEM(出版)
Document CreatorAdobe Illustrator CS2

NOTE: Slave PIR unit and water alarm selection option alternative.
PANIC
ARM
DISARM
about 20~30 meters
(open space)
Main unit
( Fig. 2)
(Fig. 2)
Black striped wire
to negative (-)
( Fig.3 )
3. Connect the extended outdoor siren cable to the terminal post located in the back of main unit inside the terminal
compartment. The polarity as shown below. (Fig.3)
NOTE: The outdoor siren (515SK/E)option, not included.
MODEL 200R (Wireless Remote Control)
1.Battery install and replacement (Battery Type-23A 12V)
a. Remove the battery compartment cover by sliding it in the direction of the arrow.
b. Replace with new batteries of the same type.
Make sure the polarity (+ or -) of the batteries match the polarity marks inside the unit. As shown below. (Fig. 1)
c. Replace battery cover.
4. Connect the magnetic sensor (detect door/window is opened, will trigger auto dialer and alarm after "entry delay time").
(NOTE: The magnetic is for optional, not included)
a. Measure the length of wire needed to connect the sensor to the transmitter, then cut the wire to the correct length.
Strip about 1/2 inch of insulation from the wire ends, and twist the wires together.
b. Connect the sensor switch on door to the main terminal post using the wire you just cut. (There is no polarity need to
be taken care of, any terminal will be fine, as long as the wires from a loop).
c. Connect another sensor switch screw to another switch terminal post by using the parallel another wire as shown
below. (Fig.4)
d. Wire not included.
NOTE: If you connect more than one sensor to the main unit, connect them in series as shown below. (Fig.5)
(Fig.1)
LEARNING CODE TO MAIN UNIT
The wireless remote control with the package of this system are completed done the LEARN CODE. The whole units are
standby for use after installed directly. When relearn code operation see main unit manual.
Notes for remote operation
● If radio linked remote control operation range becomes shorten, replace the batteries according to "BATTERIES
REPLACEMENT".
● The battery life should be about six months under normal use, so replace battery at least every 6 months. Effective
range. (Fig. 2)
( Fig.5)
Slave Unit
Sensor Switch
(Mount the door/window frame)
Magnet sensor
(Mount the door/window frame)
Sensor Switch
( Fig.4 )
5. Mount the magnet sensor to the door/window frame by using the double-side tapes and aligned the 2 sensor pieces to
be tidiness and "arrow" facing "arrow" at no more than 1/4 inch apart. (Fig.6)
about 30~40 meters
(open space)
(Fig.2)
arrow facing arrow
( Fig. 6)
OPTIONAL WIRED ACCESSORIES
( Fig. 7 )
1. Connect the PIR slave extended unit (not included, option for 113E)
a. Connect the PIR slave extended unit cable to the terminal post located in back of the main unit inside the terminal
compartment. See polarity below. ( Fig.1A)
b. Plug the 3.5mm diameter male plug of slave extended cable that from the main unit into the jack located on side of
the unit. (Fig.1B)
Black
TROUBLE SHOOTING GUIDE
Slave Unit
Red
From Main Unit
White
Slave Extended Cable
( Fig.1A )
(Fig.1B)
2. Connect the water alarm (not included, option for 760A)
Connect the water alarm to the terminal post located in the back of main unit inside the terminal compartment. The
polarity as shown below. (Fig.2)
- 11 -
6. To mount the outdoor siren use the siren stand as a template, mark locations of holes and install anchors and screws
as shown below (Fig.7). It is recommended that you mount the out door siren at entrance door, top of garage door, or any
location which is sheltered from easy tamper and rain.
1. UNIT WILL NOT ARMED/DISARM
a. Make sure you've entered the correct password, if not, reenter the password.
b. If still doesn't work. use a pen to touch “RESET” button once of unit bottom, then try to ARM/DISARM again.
2. UNIT WILL NOT DIALLING
a. Make sure the telephone line be in good connection.
b. Make sure the telephone number stored.
- 12 -
c. Make sure the system should be setup in Auto dial mode.
3. NOT REMOTE CONTROL FUNCTION
a. Check if battery low and battery replacement.
b. If it doesn't work, re-learn ID code again, according to " TO LEARN WIRELESS SENSOR OR REMOTE CONTROL
ID CODE ".
TIPS
1. Make sure the full telephone has been stored.
2. If you are leaving pets at home while the Auto-Dialer is ON, then make sure the Auto-Dialer has been set in a
location high enough not to detect any animals walking around but not too high to detect other movement.
3. Keep the Auto-Dialer dust free, away from cobwebs that may cause movement in the protected area.
4. Only suitable for single phone lines. Not compatible with fax machines.
NOTE:This valuable manual will let your security system work properly. Please preserve this
manual at your record, and keep reading when need some trouble obviation.
- 13 -
Warning:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications to this unit not expressly approved by the party responsible for
compliance will void the user’s authority to operate the equipment. Any change to the
equipment will void FCC grant.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
--Consult the dealer or an experienced radio/TV technician for help.
The equipment compliance with FCC radiation exposure limit set forth for uncontrolled
Environment
Manufacturer my void users authority to operate this device.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 3
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:2ee4d55c-38eb-4a85-a993-3cb319f14de3
Producer                        : Adobe PDF library 7.77
Creator Tool                    : Adobe Illustrator CS2
Create Date                     : 2006:11:08 09:59:32+08:00
Modify Date                     : 2006:12:13 13:08:21-08:00
Metadata Date                   : 2006:12:13 13:08:21-08:00
Thumbnail Width                 : 120
Thumbnail Height                : 256
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 6783 bytes, use -b option to extract)
Document ID                     : uuid:E8AB4BE4CB6EDB118503F600A0A0E3B9
Instance ID                     : uuid:aeaeae2f-c53b-4516-82f6-70fe154b0a26
Derived From Instance ID        : uuid:E7AB4BE4CB6EDB118503F600A0A0E3B9
Derived From Document ID        : uuid:E5AB4BE4CB6EDB118503F600A0A0E3B9
Format                          : application/pdf
Title                           : T018 SYSTEM(出版)
Creator                         : Adobe Illustrator CS2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NS3LELUXT018R

Navigation menu