Leonardo S p a TRA100B Part 87 Aircraft Licensed Transmitter operating at 1090MHz User Manual Data Download Equipment DDE
LEONARDO S.p.a. Part 87 Aircraft Licensed Transmitter operating at 1090MHz Data Download Equipment DDE
Contents
- 1. Users manual 1
- 2. Users manual 2
Users manual 2
UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ TRA-100B Mode S Transponder (TRA-100B) Honeywell Installation Manual (IM) MAN-1168/01 T Issue No. 01 Date 04-08-2016 Leonardo Finmeccanica S.p.A. Piazza Montegrappa, 4 00195 - Roma ITALY ______________________________________________________________________________ Page 1 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ Page left intentionally blank ______________________________________________________________________________ Page 2 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ Revision List Date of Issue 04-08-2016 Issue Number Revision History 01 First Issue This document is composed of 22 pages. ______________________________________________________________________________ Page 3 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ TABLE OF CONTENTS 1. 2. GENERAL ........................................................................................................................................................... 6 1.1 TRA-100B MODE S TRANSPONDER - LIST OF ABBREVIATIONS .......................................................................................... 6 1.2 TRA-100B MODE S TRANSPONDER – CONFIGURATION .................................................................................................. 7 1.3 TRA-100B MODE S TRANSPONDER – INTRODUCTION .................................................................................................... 8 1.4 TRA-100B MODE S TRANSPONDER - SCHEMATIC DIAGRAM ............................................................................................ 9 1.5 TRA-100B MODE S TRANSPONDER – GENERAL WARNINGS AND CAUTIONS AND RELATED SAFETY DATA ................................ 10 1.5.1 General Safety .......................................................................................................................................... 10 1.5.2 List of Warnings and Cautions .................................................................................................................. 10 TECHNICAL DATA ............................................................................................................................................ 12 2.1 3. TRA-100B MODE S TRANSPONDER – TECHNICAL DATA ............................................................................................. 12 2.1.1 General Technical Data ............................................................................................................................ 12 2.1.2 Labels Data ............................................................................................................................................... 12 INSTALLATION................................................................................................................................................. 21 3.1 TRA-100B MODE S TRANSPONDER – REPLACE PROCEDURES......................................................................................... 21 ______________________________________________________________________________ Page 4 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ LIST OF ILLUSTRATIONS FIGURE 1-1 – TRA-100B MODE S TRANSPONDER - CONFIGURATION .................................................................... 7 FIGURE 1-2 – TRA-100B MODE S TRANSPONDER - SCHEMATIC DIAGRAM............................................................. 9 FIGURE 2-1 – TRA-100B MODE S TRANSPONDER – LABELS LAYOUT .................................................................. 14 FIGURE 2-2 – TRA-100B MODE S TRANSPONDER – CONNECTORS ..................................................................... 15 FIGURE 3-1 – TRA-100B MODE S TRANSPONDER - REPLACE PROCEDURES ....................................................... 22 LIST OF TABLES TABLE 1-1 - LIST OF ABBREVIATIONS .................................................................................................................... 6 TABLE 1-2 – TRA-100B - CONFIGURATION DATA ................................................................................................. 7 TABLE 1-3 - GENERAL W ARNINGS, CAUTIONS AND RELATED SAFETY DATA ......................................................... 10 TABLE 2-1 – TRA-100B - TECHNICAL DATA – GENERAL ...................................................................................... 12 TABLE 2-2 – TRA-100B - TECHNICAL DATA – CONNECTORS ............................................................................... 15 TABLE 2-3 – TRA-100B - TECHNICAL DATA – MAIN CONNECTORS PIN MAPPING .................................................. 16 TABLE 2-4 – TRA-100B - TECHNICAL DATA – TEST CONNECTORS PIN MAPPING .................................................. 20 ______________________________________________________________________________ Page 5 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ 1. GENERAL 1.1 TRA-100B MODE S TRANSPONDER - LIST OF ABBREVIATIONS Table 1-1 - List of Abbreviations Symbol Instruction AC AD, A/D BIT BITE CBIT DC GND HF IBIT LRU MT NSN PBIT RF RX TX Alternate Current Analogue to Digital Built In Test Built In Test Equipment Continuous Built In Test Direct Current GrouND High Frequency Interruptive Built In Test Line Replaceable Unit Mounting Tray NATO Stock Number Power-on Built In Test Radio Frequency Receiver Transmitter ______________________________________________________________________________ Page 6 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ 1.2 TRA-100B MODE S TRANSPONDER – CONFIGURATION This manual is applicable to the following TRA-100B Mode S Transponder Part Numbers (Table 12): Table 1-2 – TRA-100B - Configuration Data Description TRA-100B Mode S Transponder Part Number Qty TAC-6001/03 TAC-6003/03 TAC-6004/03 Figure 1-1 – TRA-100B Mode S Transponder - Configuration ______________________________________________________________________________ Page 7 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ 1.3 TRA-100B Mode S TRANSPONDER – INTRODUCTION The TRA-100B Mode S Transponder is a remote mounted avionics device which provides the Mode S Transponder function required by Technical Standard Order (ETSO-C112d). The XPDR also provides Extended Squitter ADS-B Out function required by ETSO-C166b. The TRA-100B Modes S Transponder is designed to be a Level 2 transponder. It includes the capabilities of a Level 1 Transponder: • Mode A identity and Mode C pressure-altitude reporting, • Air Traffic Control Radar Beacon System (ATCRBS)/Mode-S and Mode S all-call transactions, • Addressed surveillance altitude and identity transaction, • Lockout protocols, • Basic data protocols except data link capability reporting, and • Air-to-air service and squitter transactions. The TRA-100B includes the capabilities of a Level 2 Transponder: • Bi-directional air-to-air information exchange • Ground-to-air data uplink, Comm-A • Air-to-ground data downlink, Comm-B • Multisite message protocol • Data link capability reporting • Aircraft identification reporting • Traffic Alert and Collision Avoidance System (TCAS)/Airborne Collision Avoidance System (ACAS) crosslink capability • Overlay Command Capability In addition, the Transponder contains the following optional additional features: • TCAS Compatibility (a) • Antenna Diversity (d) • Extended Squitter (e) • Enhanced Surveillance (including Elementary Surveillance) (n) • Surveillance Identifier Code (s) ______________________________________________________________________________ Page 8 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________________________________________________________________________________________________________________________ 1.4 TRA-100B Mode S TRANSPONDER - SCHEMATIC DIAGRAM Figure 1-2 – TRA-100B Mode S Transponder - Schematic Diagram ___________________________________________________________________________________________________________________________________________________________________ Page 9 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ 1.5 TRA-100B MODE S TRANSPONDER – GENERAL WARNINGS AND CAUTIONS AND RELATED SAFETY DATA 1.5.1 General Safety 1.5.2 Before you do maintenance procedures on the Unit make sure that you know the necessary safety data. Before you work on the Unit, make sure that the electrical power supply is removed from the Unit. Energized circuits can cause injury to persons. Before you work on the Unit, make sure that you have the correct personal safety equipment. You must use or wear the correct personal safety equipment to prevent injuries. Handle all the equipment carefully. This will help to prevent damage to it. List of Warnings and Cautions Table 1-3 - General Warnings, Cautions And Related Safety Data Symbol Message WARNING Make sure that the equipment is disconnected from all electrical power sources before you do any maintenance work. WARNING The internal components use high voltages that can cause injury or death to personnel. WARNING Perform task in ventilated area and use protective clothing. WARNING Denatured Alcohol, Electro Contact Cleaner and Conductive Antiseizure Compound are dangerous materials. Make sure that you know the safety precautions and the first aid instructions. ______________________________________________________________________________ Page 10 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ CAUTION The internal components of the equipment are Electro-Static Discharge (ESD) sensitive devices. Do not touch the pins of the electrical connectors. Electrostatic discharge can cause damage to these components. Install protective caps on all electrical connectors immediately after you disconnect them to prevent the ingress of dirt. WARNING Always handle the equipment with care to prevent damage. ______________________________________________________________________________ Page 11 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ 2. TECHNICAL DATA 2.1 TRA-100B MODE S TRANSPONDER – TECHNICAL DATA 2.1.1 General Technical Data Table 2-1 – TRA-100B - Technical data – General Data Value Manufacturers Part Numbers TAC-6001/03 TAC-6003/03 TAC-6004/03 Weight (Total mass) < 7 Kg. Dimensions 194 mm x 124 x 318 (Height x Width x Depth) Output power 400W ± 100 W Operating temperature -55°C +70°C Storage Conditions -55°C +70°C 2.1.2 Labels Data The TRA-100B provide three different labels (ref. Figure 2-1): Leonardo Finmeccanica Id. Label (1) Honeywell Id. Label (2) Certifications Label (3) ______________________________________________________________________________ Page 12 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ The Leonardo Finmeccanica Id. Label contains the following info: Data Value Manufacturers Part Numbers TAC-6001/03 TAC-6003/03 TAC-6004/03 Manufacturer Leonardo Finmeccanica Manufacturing Site Montevarchi Manufacturing Country Italy SER. Serial Number MFR. Manufacturer SNS (A0610) DMF Date of Manufacturing (mmyyy) AMDT Amendement Weight (Total mass) 14.5 Lbs. (6.58 Kg) Power 115 VAC/380-420 Hz. The Honeywell Id. Label contains the following info: Data Value Owner HONEYWELL, International Owner Part Number PNR 066-01212-0101 PNR 066-01212-0301 PNR 066-01212-0301 Amendement ______________________________________________________________________________ Page 13 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ The Certification Label contains the following info: Data Value ETSO/TSO Certification REMOVE COVER TO ACCESS SUPPORT TEST CONNECTORS DO/ED ETSO C112d: L2 adens, Class 1 ETSO C166b: Class A2 Tx only 178B/12B B: D 254/80 B 160/14G Selex ES S.p.A 11 12 13 14 15 16 17 18 19 20 WEIGHT 14,5 Lbs (6,58 Kg) POWER 115 VAC/380-420 Hz TRA-100B TRANSPONDER SER M00000000 MFR A0069 DMF 01/2013 AMDT 01 02 03 04 05 06 07 08 09 10 MFR PNR 0 A TAC-6001/01 1 PNR 066-01212-0101 TSO C112d: xxx C166b: xxx DO-178B: B,D DO-160G Figure 2-1 – TRA-100B Mode S Transponder – Labels Layout ______________________________________________________________________________ Page 14 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ Table 2-2 – TRA-100B - Technical data – Connectors Ref. Figure 2-2 Connector Function Main Connector Data and Control I/O Test Connector Maintenance Retrieval Figure 2-2 – TRA-100B Mode S Transponder – Connectors ______________________________________________________________________________ Page 15 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ Table 2-3 – TRA-100B - Technical data – Main Connectors Pin Mapping TP Section Pin TP 1A TP 1B TP 1C TP 1D TP 1E TP 1F TP 1G TP 1H TP 1J TP 1K TP 2A TP 2B TP 2C TP 2D TP 2E TP 2F TP 2G TP 2H TP 2J TP 2K TP 3A TP 3B TP 3C TP 3D TP 3E TP 3F TP 3G TP 3H TP 3J TP 3K TP 4A TP 4B TP 4C TP 4D TP 4E TP 4F TP 4G TP 4H TP 4J TP 4K TP 5A TP 5B TP 5C TP 5D TP 5E I/O Input Input Input Input Input Input Input Input Input Input Input Input Input Input Output Output Input Input Input Input Output Output Input Input Input Common Input Input Common Common N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Input Input Input Common Input Type Program Program Strobed Program Strobed Program Strobed Program Strobed Program Strobed Program Strobed Program Strobed Differential Differential 429 429 429 429 429 429 429 429 Discrete Program Discrete Discrete Program Program Program Common Discrete Discrete Common Common N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Program Program Program Common 429 Description AC Length/Width A MSB AC Length/Width B AC Length/Width C LSB GPS Ant Long Off A (MSB) GPS Ant Long Off B GPS Ant Long Off C (LSB) Navigation Accuracy Category Velocity (NACV) System Design Assurance (SDA) GPS Time Mark 1A GPS Time Mark 1B FMC/GNSS #1 In #1 A FMC/GNSS #1 In #1 B IRS/FMS/Data Conc. A IRS/FMS/Data Conc. B General Output #1 A General Output #1 B ATSU In A ATSU In B Data Load Enable ADS-B FAIL Disable ADS-B Fail Disc Out Transponder fail #2 Disc output Cable Delay Program Top/Bot Cable Delay Program Value #1 Cable Delay Program Value #2 Common SDI 429 Bus Address Logic Input SDI 429 Bus Address Logic Input Common Common No Connect No Connect No Connect No Connect No Connect No Connect No Connect No Connect No Connect No Connect Maximum Airspeed 17 Maximum Airspeed 16 Maximum Airspeed 15 Top Plug Common TX Coordination A ______________________________________________________________________________ Page 16 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ TP Section Pin TP 5F TP 5G TP 5H TP 5J TP 5K TP 6A TP 6B TP 6C TP 6D TP 6E TP 6F I/O Input Output Output Input Input Input Input Output Input Input Input Type 429 429 429 Discrete Discrete 429 429 Discrete Discrete Discrete Discrete TP 6G TP 6H TP 6J TP 6K TP 7A TP 7B TP 7C TP 7D TP 7E TP 7F TP 7G TP 7H TP 7J TP 7K Input N/A N/A Input Input Input N/A Input Input Input Input Input Input N/A Discrete N/A N/A Program 429 429 N/A Discrete 429 429 Discrete 429 429 N/A Description TX Coordination B XT Coordination A XT Coordination B Air/Ground Discrete #2 Air/Ground Discrete #1 FMC #1 / Gen In #2 A FMC #1 / Gen In #2 B Reserved GPS Time Mark 2A GPS Time Mark 2B Reserved Reserved (-0101/-0301); FAA - L_Sense Activate (-0201) No Connect No Connect Antenna Program Control Data 'A' or FCC #1/MCP #1/VHF #1 A Control Data 'A' or FCC #1/MCP #1/VHF #1 B No Connect Control Data Port Select Control Data 'B' A Control Data 'B' B Standby/On Discrete ARINC 706/575 Air Data Input Port 1A ARINC 706/575 Air Data Input Port 1B No Connect MP Section Pin I/O Type Description MP 1A Input Program Mode S Address A1 (MSB) MP 1B Input Program Mode S Address A2 MP 1C Input Program Mode S Address A3 MP 1D Input Program Mode S Address A4 MP 1E Input Program Mode S Address A5 MP 1F Input Program Mode S Address A6 MP 1G Input Program Mode S Address A7 MP 1H Input Program Mode S Address A8 MP 1J Input Program Mode S Address A9 MP 1K Input Program Mode S Address A10 MP 2A Input Program Mode S Address A11 MP 2B Input Program Mode S Address A12 MP 2C Input Program Mode S Address A13 MP 2D Input Program Mode S Address A14 MP 2E Input Program Mode S Address A15 MP 2F Input Program Mode S Address A16 MP 2G Input Program Mode S Address A17 MP 2H Input Program Mode S Address A18 MP 2J Input Program Mode S Address A19 MP 2K Input Program Mode S Address A20 ______________________________________________________________________________ Page 17 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ MP Section Pin I/O Type Description MP 3A Input Program Mode S Address A21 MP 3B Input Program Mode S Address A22 MP 3C Input Program Mode S Address A23 MP 3D Input Program Mode S Address A24 (LSB) MP 3E Common Common Common MP 3F Input 429 Spare 429 Input 1A MP 3G Input 429 Spare 429 Input 1B MP 3H Input Discrete Functional Test MP 3J Output Discrete Out Spare 1 MP 3K Output Discrete Transponder Fail # 1 discrete output MP 4A Input Discrete Spare In1 MP 4B Input Discrete Spare In2 MP 4C Input 429 FMC/GNSS #2 In #1 A MP 4D Input 429 FMC/GNSS #2 In #1 B MP 4E Input Program Strobed Aircraft Category A (MSB) MP 4F Input Program Strobed Aircraft Category B (LSB) MP 4G Input Program ADS-B Configuration Parity MP 4H Input Program Strobed ADS-B Receive Capability MP 4J Input Discrete Spare In3 MP 4K Input Discrete Spare In4 MP 5A Input 429 ARINC 706/575 Air Data Input Port 2A MP 5B MP 5C MP 5D MP 5E MP 5F Input N/A N/A Output Output 429 N/A N/A 429 429 ARINC 706/575 Air Data Input Port 2B No Connect No Connect ATSU Out #1 A ATSU Out #1 B MP 5G Input Discrete Extended Squitter Disable MP 5H Input Discrete Spare In5 (Mode S DL/DLP Program) MP 5J Input Program Antenna BITE Program MP 5K Input Discrete Spare In6 MP 6A Input 429 Maintenance Data Input Port A MP 6B MP 6C MP 6D Input Output Output 429 429 429 Maintenance Data Input Port B Maintenance Data Output Port A Maintenance Data Output Port B MP 6E Input Discrete Alternate Air Data Source Select MP 6F Input Program Altitude Type Select A Discrete Input MP 6G Input Program Altitude Type Select B Discrete Input MP 6H MP 6J Common N/A Common N/A Middle Plug Common No Connect MP 6K MP 7A MP 7B MP 7C MP 7D MP 7E MP 7F MP 7G Common N/A N/A N/A N/A N/A N/A N/A Common N/A N/A N/A N/A N/A N/A N/A Common No Connect No Connect No Connect No Connect No Connect No Connect No Connect ______________________________________________________________________________ Page 18 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ MP Section Pin MP 7H MP 7J I/O N/A N/A Type N/A N/A Description No Connect No Connect MP 7K Input Discrete Acquisition Squitter Inhibit (Honeywell Defined) BP Section Pin I/O Type Description BP 1 Input Power 115 VAC Primary Power Hot BP 2 N/A N/A No Connect BP 3 N/A N/A No Connect BP 4 N/A N/A No Connect BP 5 N/A N/A No Connect BP 6 N/A N/A No Connect BP 7 Input Power 115 VAC Primary Power Cold BP 8 Input Ground Signal Ground BP 9 N/A N/A No Connect BP 10 N/A N/A No Connect BP 11 Input Ground Chassis Ground BP 12 Input/Output Suppression Suppression Pulse BP 13 Input/Output Suppression Suppression Pulse - Daisy Chaining ______________________________________________________________________________ Page 19 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ Table 2-4 – TRA-100B - Technical data – Test Connectors Pin Mapping Test Connector Pin Signal Name TEST_RESET GND UP_HRESET Out Test Point Test Point VID_ENV_TOP_TP Out Test Point Test Point TEST_DG18 ST_GATE TEST_DG19 Internal Purpose Only TEST_DG20 Internal Purpose Only 10 TEST_DG21 Internal Purpose Only 11 TEST_DG22 12 ACQ_SQ_INH_EN In Discrete In 1 Acquisition Squitter Inhibit Enable 13 PULSE_GATE Out Test Point Test Point 14 OP_MAINT_1 In Discrete In 1 Maintanance Mode Selection 15 OP_MAINT_0 In Discrete In 1 Maintanance Mode Selection 16 VID_ENV_BOT_TP Out Test Point Test Point 17 FPGA _SIN 18 FPGA _SOUT 19 DG_INT_PWRFL Out Test Point Test Point 20 SUPP_TP Out Test Point 21 E2C_SCL_PN In 22 E2C_SDA_PN Bdir 23 WR_UNPROTECT In 24 GND_EXT 25 5V_EXT Test Point Service I2C Bus Ctrl/Clk In Service I2C Bus Data Service I2C Bus Ctrl/Clk In Service I2C Bus Supply In Service I2C Bus Supply In I/O Type Discrete In 1 Description Switch Ethernet Out Test Point Test Point SWITCH_ETH Power GND Internal Purpose Only Out Test Point Test Point Internal Purpose Only Internal Purpose Only Internal Purpose Only In Service I2C Bus Serial Clock Service I2C Bus Serial Data Service I2C Bus Control Signal Service I2C Bus Power Supply Ground Power Supply Source for Service I2C Bus ______________________________________________________________________________ Page 20 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ 3. INSTALLATION 3.1 TRA-100B MODE S TRANSPONDER – REPLACE PROCEDURES Standard Equipment Description Identification Nr. Qty Identification Nr. Qty Description Identification Nr. Qty TRA-100B Mode S Transponder TAC-6001/03 TAC-6003/03 TAC-6004/03 None Materials Description None Spares Safety Precautions WARNING MAKE SURE THAT THE EQUIPMENT IS DISCONNECTED FROM ALL ELECTRICAL POWER SOURCES BEFORE YOU DO ANY MAINTENANCE WORK. ______________________________________________________________________________ Page 21 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED UNCLASSIFIED MAN-1168/01 T01 ___________________________________________________________________________________________________________ Preliminary Operations 1. Make sure the platform is safe for maintenance Procedure 1. Removal Procedure 1.1. Loosen by hand the two hold-down screws on the front of Mounting Tray (1) 1.2. Pull the Transceiver by the handle 1.3. Carefully slide the Transponder from the Mounting Tray 2. Install Procedure 2.1. Carefully put the TRA-100 B Modes S Transponder into the Mounting Tray, aligning the TRA-100B connector guide pins with the platform connector. 2.2. Tighten by hand the two hold-down screws (1) on the front of Mounting Tray Figure 3-1 – TRA-100B Mode S Transponder - Replace Procedures Close up 1) Removal all the tools, the materials and the equipment from your work area. ______________________________________________________________________________ Page 22 © Copyright Leonardo Finmeccanica S.p.A. – All rights reserved UNCLASSIFIED
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 22 Language : it-IT Tagged PDF : Yes Title : Data Download Equipment (DDE) Author : Selex Communications Creator : Microsoft® Word 2010 Create Date : 2016:08:05 15:18:25+02:00 Modify Date : 2016:08:05 15:18:25+02:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools