Liebert Refrigerator Xdp160Ra Users Manual 16644
XDP160RC to the manual 0fcf2848-72ad-4921-9f3d-1882e8efeaf5
2015-02-09
: Liebert Liebert-Liebert-Refrigerator-Xdp160Ra-Users-Manual-571446 liebert-liebert-refrigerator-xdp160ra-users-manual-571446 liebert pdf
Open the PDF directly: View PDF
Page Count: 80
- Important Safety Instructions
- 1.0 Product Description
- 1.1 General Product Information
- 1.2 Equipment Inspection
- 1.3 Equipment Handling
- 2.0 Installation
- 3.0 Piping
- 3.1 European Union Fluorinated Greenhouse Gas Requirements
- 3.2 Connection Sizes
- 3.3 Liebert XDP Interconnection with Liebert XD Cooling Modules
- 3.4 Piping Installation Methods
- 3.5 Piping Details—Shutoff/Isolation Valves
- 3.6 Filling the Pumped Circuit—R-134a
- Table 6 System R-134a charge for a Liebert XDP with any model Liebert XDH/Liebert XDO/Liebert XDV/Liebert XDCF/Liebert XDR
- Table 7 System refrigerant charge for the supply and return mains
- Table 8 R-134a refrigerant charge for hard-piped connector lines to and from any model Liebert XDH/Liebert XDO/Liebert XDV/Liebert XDCF/Liebert XDR
- Table 9 R-134a refrigerant charge for Flex Pipe connector lines to and from any model Liebert XDO/Liebert XDH/Liebert XDV/Liebert XDCF/Liebert XDR
- 3.6.1 Calculating Refrigerant Charge—Example
- 3.7 Checklist for Proper Installation
- 4.0 Liebert iCOM Control—Firmware Version XP1.00.010.STD
- 4.1 Liebert iCOM Components and Functions
- 4.2 Display Lamp Indicators
- 4.3 Navigating Through the Liebert iCOM Display
- 4.4 Changing Liebert iCOM’s Display Settings
- 4.5 Changing Operational Settings
- 4.6 Graphical Data Record
- 4.7 Liebert iCOM User Menu Icons and Legend
- 4.8 Liebert iCOM User Menu Screens
- Figure 31 Setpoints screen
- Spare Parts
- Event Log
- Figure 32 Set Alarms screen
- Figure 33 Sensor Data screen, page 1 of 2
- Figure 34 Sensor Data screen, page 2 of 2
- Figure 35 Display Setup screen
- Figure 36 Module Status screen, page 1 of 20
- Figure 37 Liebert XDV Smart Module Status screen
- Figure 38 Liebert XDH Smart Module Status screen—each bank shown separately
- Figure 39 Liebert XDO Smart Module Status screen
- Figure 40 Total Run Hours screen
- 4.9 Liebert iCOM Service Menu Icons and Legend
- 4.10 Liebert iCOM Service Menu Screens
- Figure 43 Setpoints screen
- Figure 44 Maintenance—Basic Settings screen, page 1 of 7
- Figure 45 Maintenance—Pump 1 Settings screen, page 2 of 7
- Figure 46 Maintenance—Pump 2 Settings screen, page 3 of 7
- Figure 47 Maintenance screens, pages 4 through 7
- Figure 48 Diagnostics/Service Mode screen, page 1 of 6
- Figure 49 Diagnostics/Service Mode screen, page 2 of 6
- Figure 50 Diagnostics/Service Mode screen, page 3 of 6
- Figure 51 Diagnostics/Service Mode screen, page 4 of 6
- Figure 52 Diagnostics/Service Mode screen, page 5 of 6
- Figure 53 Diagnostics/Service Mode screen, page 6 of 6
- Figure 54 Set Alarms screen, page 1 of 7
- Figure 55 Set Alarms screen, page 2 of 7
- Figure 56 Set Alarms screen, page 3 of 7
- Figure 57 Set Alarms screen, page 4 of 7
- Figure 58 Set Alarms screens, pages 5 and 6
- Figure 59 Set Alarms screen, page 7 of 7
- Figure 60 Sensor Calibration/Setup screen, page 1 of 3
- Figure 61 Sensor Calibration/Setup screen, page 2 of 3
- Figure 62 Sensor Calibration/Setup screen, page 3 of 3
- Figure 63 System/Network Setup screen—System, page 1 of 2
- Figure 64 System/Network Setup screen—System, page 2 of 2
- Figure 65 System/Network Setup screen—Unit, page 1 of 2
- Figure 66 System/Network Setup screen—Unit, page 2 of 2
- Figure 67 Options Setup screen, page 1 of 2
- Figure 68 Options Setup screen, page 2 of 2
- Figure 69 Module Setup screen, page 1 of 20
- Figure 70 Module Setup screen, page 1 of 20
- 5.0 Start the Liebert XDP with Liebert iCOM
- 6.0 Alarm Descriptions and Solutions
- 7.0 Troubleshooting
- 8.0 Maintenance
- 9.0 Specifications