Lifeline Systems 7101MHB GoSafe and GoSafe 2-Mobile Help Button for a Personal Emergency System (PERS) User Manual Manual 2

Lifeline Systems Inc GoSafe and GoSafe 2-Mobile Help Button for a Personal Emergency System (PERS) Manual 2

Manual 2

GoSafe 2 Mobile Medical Alert ServiceInstructions for useMedical Alert ServiceInstructions for useAgency Filing Copy
3Questions? Call 1-800-635-6156Important Notice to User The GoSafe 2 Mobile Pendant is a radio frequency (RF) device that transmits all of its signals to the Lifeline Response Center over a cellular network. As such, it relies upon adequate cellular network availability and signal strength, at the time and location of alarm generation, to send your help signal to the Lifeline Response Center. Cellular signal strength and availability inside of your home is tested during the system setup process, but can vary from time to time depending on multiple factors, and is therefore not guaranteed to remain at that level over time. This variation is not due to the design of GoSafe 2, nor is it unique to a single cellular carrier. It is the general nature of cellular communication, and indicative of the limitations thereof. Please refer to this Instruction for Use, as well as the Terms and Conditions of Sale/Use provided with your System for a full listing of Limitations of cellular service.  Philips Lifeline also provides a GoSafe Mobile System that utilizes a Home Communicator to help provide increased communication capability for signals generated from within your home. If this statement or the Limitations dened herein are unclear to you, if you would like to learn more about the GoSafe Mobile System with Home Communicator, or if you did not receive a copy of the Terms and Conditions of Sale/Use, please contact Philips Lifeline or its representative. Agency Filing Copy
3Questions? Call 1-800-635-6156ContentsAbout This Manual ................................4 TrainingDenitions and TerminologyPhilips Lifeline Service ............................ 9 Welcome to Philips LifelineSetting up your Philips Lifeline ServiceResponders and People to NotifyCalling for helpSignal RangeBattery informationEquipment serviceContact Philips Lifeline or your representativeGoSafe 2 Mobile Medical Alert System General Information ..............................18 Cleaning and CareGeneral Cautions and WarningsGoSafe 2 Mobile Pendant (7150 MHB) ..............21 Charging the batterySleep modeRecommended usageGoSafe 2 Mobile Pendant AlarmsAlarm Descriptions/Summary TablesSafety and Regulatory Compliance ................ 46 IEC regulationsDevice classicationRadio specicationsFCC Notice to UsersIntended UseCompatibilityRisks and BenetsSafetyMaintenanceTechnical SpecicationsAgency Filing Copy
4Questions? Call 1-800-635-6156About This Manual  Training Reading and understanding these Instructions for Use and the Quick Setup Guide serves as adequate training for the installation, use and disposal of the equipment. Users of this product must review and understand the Instructions for Use  document to help provide safe and eective use. If you require further information about training in the use of this product, please contact Philips Lifeline or your Philips Lifeline representative. Denitions & Clarifying Terminology7150MHB: The model name for the GoSafe 2 Mobile Pendant for FDA registration purposes. This name is used in the “Alarms” and “Safety and Regulatory Compliance” sections. Alarm State: When you press the Help Button or when an un-revoked fall is detected, the Pendant will initiate a help call to the Philips Lifeline Response Center. During this time, until the Pendant is reset, the Pendant is in Alarm State. Certain behaviors described herein only take place during Alarm State.Audio Beacon: A very loud, siren-like noise generated by the Pendant that can be activated by the Response Center during Alarm State. It is designed to help responders nd you more easily while searching for you. Refer to page 25.  AutoAlert: The Philips fall detection technology that is used by the GoSafe 2 Mobile Pendant.  Agency Filing Copy
5Questions? Call 1-800-635-6156Cellular Network: The AT&T cellular/wireless network.Charger: The component of your GoSafe 2 Mobile System that is used to re-charge your Mobile Pendant. (See p. 22) Charger Pins: The gold pins on the charger itself that engage with the charging interface contacts.Charging Interface Contacts: The gold circles on the back side of the pendant.  Coverage Area: The area from which your pendant is capable of sending and connecting a help call. As a cellular communication device, the coverage area for GoSafe 2 Mobile Pendant is dened by the cellular network availability and signal in your location, at the time of the alarm. Refer to the “Terms and Conditions of Use” document you received with your system for details on the limitations of cellular service.Critical Charge Indication: The point at which the Pendant no longer has sucient battery power left to operate normally. It will play a voice prompt and turn o at this point. EMS: Emergency Medical Services. Police, Fire or Ambulance service depending on your area. End Device: The device that initiated the alarm. In this case, the GoSafe 2 Mobile Pendant.Fall Revocation: Many Users may experience mild, non-harmful falls from which they are able to self-recover without assistance. As a result, the AutoAlert fall detection technology incorporates a revocation feature. Upon detecting a fall, the system will wait approximately 30 seconds before alarming to the Response Center. If the User self-recovers from the fall Agency Filing Copy
6Questions? Call 1-800-635-6156within that time period, the fall will not be reported. Users should always press the Help Button when they need help if they are able to do so.  Help Button: The Help Button is the depressed square area inside the grey eld on the front of the pendant itself. When pressed, a prompt call to the Philips Lifeline Response Center is placed. To initiate a call to Philips Lifeline, press the Help Button. A voice prompt and red Indicator Light will conrm  that you have activated the Pendant and that your call is  in progress.GoSafe 2: GoSafe 2 is a product-enabled service. The Mobile Pendant that you wear works in conjunction with the mobile network to connect to the Philips Lifeline Response Center. Together, the Pendant, Network and Response Center comprise the service elements.GoSafe 2 Mobile Medical Alert System: Your System is comprised by your GoSafe 2 Mobile Pendant and the  Pendant Charger.Help Alarm Signal: This is the type of signal that the Philips Lifeline Response Center receives from the Pendant when the Help Button is pressed. Indicator Light: A small light just above the Help Button, inside the grey area on the front of the Pendant. It may illuminate either green, orange or red, and either blink or shine consistently depending on what it is indicating. A complete guide to the dierent colors and whether they are blinking or not is included at the back of this Instruction for Use. See Alarm description and summary table, page 37. Agency Filing Copy
7Questions? Call 1-800-635-6156Initial Recharge Indication: The Pendant chimes and the orange Indicator Light starts to blink. This is the point at which you should re-charge your Pendant. Intended Use: The purpose for which the system was specically designed. GoSafe 2 was designed for people to wear and help maintain their independence, knowing that if they need assistance at home or away,* they can access help.  Lifeline: The emergency response service associated with your GoSafe 2 Mobile Pendant. Notify: An individual who will be advised, after the fact, of any alarm whereby assistance was required. A person or persons who you want to be told if you experienced an emergency and Philips Lifeline was engaged to facilitate response.  Noties will not be advised of false alarms or test calls.  See page 12.Pendant: This is the device that you physically wear around your neck. Also, the 7150MHB. Personal Response Associate or Response Associate: A Lifeline operator trained to answer emergency calls. Personal Response Associates are trained to take emergency calls and facilitate assistance for Lifeline subscribers.Philips Lifeline: the name of the company that provides GoSafe 2 and the Lifeline medical alert service. Recommended Usage: How you should use and interact with the Pendant and Response Center for normal use.*  GoSafe 2 coverage inside and outside the home is provided where AT&T wireless network coverage is available. Recharging of the GoSafe 2 Mobile Pendant is done by the user as needed, when connected to the Charger.Agency Filing Copy
8Questions? Call 1-800-635-6156Responder(s): If you should need emergency assistance and activate your Pendant, a responder is someone you want Philips Lifeline to contact to physically go to you and help you. You can have more than one Responder. In an emergency, Philips Lifeline will contact them in prioritized order until we are able to connect with someone that can get to you and help you. See page 11. Response Center: The Philips Lifeline call center where calls from your Pendant are answered.Sleep Mode: The Pendant is essentially turned o. When in Sleep Mode, the Pendant will not detect falls, will not automatically update its location information, and will not make a help call with a single button press. Standby Mode: This is the normal operating mode that the Pendant is most often in while you are wearing it. The Pendant is powered-on, with all systems functioning, but is not in Alarm State. Subscriber: A user of the Philips Lifeline Medical alert service. Also, User.Agency Filing Copy
9Questions? Call 1-800-635-6156Your Philips Lifeline ServiceWelcome to Philips LifelineThank you for choosing the Philips Lifeline Medical  Alert Service. Please refer to the Quick Setup Guide provided for instructions on setting up your equipment. These Instructions for Use will provide you with information about your equipment and the Philips Lifeline Medical Alert Service. Please read this manual and the Quick Setup Guide carefully, and note the Warnings and Cautions. If you have questions, call Philips Lifeline at any time using the number listed at the bottom of the page. Please save this manual. It includes important information you may need to refer to later.Warnings and CautionsPlease pay special attention to all the instructions provided  in the Warning and Caution sections.  Warning alerts you to a potential serious outcome, adverse event or safety hazard. Failure to observe a warning may result in death or serious injury to the user or patient.  Caution alerts you to where special care is necessary for the safe and eective use of the product. Failure to observe a caution may result in minor or moderate personal injury or damage to the product or other property, and possibly in a remote risk of more serious injury, and/or cause environmental pollution. Agency Filing Copy
10 Questions? Call 1-800-635-6156These Instructions for Use and the Quick Setup Guide describe the most extensive conguration of the product. This manual covers the following: GoSafe 2 Mobile Pendant (7150MHB)Works inside and outside*  of your home Can only be worn around the neck as a pendant Can detect falls** inside  your home Can detect falls** outside*  your home Provides 2-way voice communication with Philips Lifeline Waterproof to 1 meter (40”)  for up to 30 minutes *  GoSafe 2 coverage inside and outside the home is provided where AT&T wireless network coverage is available. Recharging of the GoSafe 2 Mobile Pendant is done by the user as needed, when connected to the Charger.** The GoSafe 2 Mobile Pendant provides an extra layer of protection by placing a Help Call if a fall is detected and you can’t push the Help Button. Not all falls can be detected. If you need help, always press the Help Button if you are able to do so.Setting up your Lifeline ServiceBefore you can use your GoSafe 2 System, it must be properly set up. Please see the Quick Setup Guide for instructions on how to set up your system. If you have any questions, please contact Philips Lifeline or your representative. Agency Filing Copy
11Questions? Call 1-800-635-6156Responders and People to NotifyWhat is a “Responder”? As a Philips Lifeline subscriber, you should have designated people who have agreed to be “Responders.” These are people whom Lifeline should call in an emergency, when appropriate. Examples include: neighbors, friends, relatives, your current nursing aide, etc.Choosing a Responder It is best to choose a Responder who:• Has a key to your home or knows where one is located (perhaps in a key lockbox),• Could come to help you at dierent times of the day or night,• Lives or works within 10 minutes of where you live,• Has a phone, preferably a cell phone, • Ideally has a driver’s license and access to a vehicle, and• Is physically capable of assisting you.Since the GoSafe 2 System allows you to call for help both at and away from home, it is best to choose a Responder who can also:• Drive to your location, whether you are at home or away from home, and provide help if needed.Information Philips Lifeline needs about RespondersPlease ensure that Philips Lifeline has the phone number or numbers that each responder is most likely to answer.It is very important that you keep your Responder information up to date. Remember to contact Philips Lifeline if one of your Agency Filing Copy
12 Questions? Call 1-800-635-6156Responders is no longer able to assist you or if they get a new telephone number.Please contact Philips Lifeline for any questions about selecting or being a Responder. Most importantly, if you list someone as a Responder, make sure you tell that person that you have done so, and that they agree to act as a Responder.Who are “People to Notify” or “Noties”?If you use your System to call for help, after response has been facilitated, Philips Lifeline will contact the “People to Notify” identied in your subscription prole to let them know that you received assistance. “People to Notify” will not be contacted to help you, unless they are also on your list of “Responders.” Neither Responders nor Noties will be contacted in the event of a test signal or when you activate your system but do not need help – such as during an accidental Help Button press.Calling for help inside your home1. Press the Help Button on the GoSafe 2  Mobile Pendant. The Pendant will tell you that your call is in progress, and to please wait. Once the call has registered with the Lifeline Response Center, your Pendant will tell you that your call has been connected. This means that our system has compiled all of your information and that your case is being delivered to a Lifeline Personal Response Associate who will speak with you momentarily.   Note: The Response Center is available 24 hours a day, 365 days a year. Your Lifeline subscription provides for unlimited Agency Filing Copy
13Questions? Call 1-800-635-6156calls to the response center without penalty. A trained Personal Response Associate is always available to assist you.Hello, Mrs. Smith.Do you need help?Your help call is in progress.  Please wait.122. Your Pendant calls the Lifeline Response Center. When it dials the Response Center, your Pendant will repeatedly say: “Your Help Call is in progress; please wait.” Once it connects with the Response Center, it will say: “Your call has been connected; Lifeline will be right with you.” It is normal to experience a slight delay prior to speaking with a  Response Associate. 3. The Response Center will answer the call. A Lifeline Response Associate will speak to you through the Pendant’s built-in speaker and hear you through the highly sensitive microphone. The Personal Response Associate will ask if you need help. If you do not need help, just tell them that no help is needed.Note: If you cannot speak or be heard through the Pendant, the Response Associate may try calling you back on your home phone. If you cannot answer or if the Response Associate cannot hear you, Lifeline will contact your Responder(s) or emergency services.*Agency Filing Copy
14 Questions? Call 1-800-635-6156*In the case of a fall detected, if the Response Associate cannot hear you and/or is unable to contact you through your GoSafe 2 Pendant or your alternate contact numbers such as your home or cell phone, emergency services will be contacted to respond. Please contact Philips Lifeline if you wish to opt out of this escalation protocol.4. The Response Center will assess the situation. If help is needed, the Response Associate will begin contacting your list of Responders (or emergency services) in accordance with your request, until they are able to reach someone who accepts the action of going to help you. 5. Once Lifeline has dispatched help, the Response Associate will contact you by calling your home phone or by calling-back your Pendant to conrm that you received the help that you needed. 6. Once Lifeline conrms that you have been assisted, a Response Associate will contact the “People to Notify” you’ve designated, letting them know that you needed and received help.Note: If you accidentally press your Help Button, do not panic. Allow the call to connect. A Response Associate will answer your call and ask if you need help. Simply tell them that “No help is needed”, and conrm to them that you are OK. Don’t be concerned that you are bothering Lifeline; we just want to be sure that you are alright. This is part of the serivce that you are paying for and there is no extra charge for accidental calls. Signal CoveragePlease see the Quick Setup Guide located in the box for instructions on how to set up your GoSafe 2 system. Your Pendant must be tested prior to use by initiating a call to the Response Center. The GoSafe 2 Mobile Pendant is a radio Agency Filing Copy
15Questions? Call 1-800-635-6156frequency (RF) device that transmits a signal to the Lifeline call center over a Cellular network. It relies upon adequate cellular network availability to send your help signal to the Lifeline Response Center. Cellular signal strength and availability inside of your home is tested during the system setup process, but can vary from time to time depending on multiple factors. It is therefore recommended that, once your welcome/setup call is complete, you go to areas of your home where you commonly spend time, as well as areas where you are most likely to have an accident – such as the bedroom, bathroom and kitchen – to check that your GoSafe 2 pendant has sucient cellular signal available to operate reliably from within your home. See the caution section on page 17. Caution: Your GoSafe 2 Pendant is designed to work inside and outside of your home from anywhere sucient connectivity to the AT&T cellular network is available. When you press the Help Button while away from home, help will be sent to your location.* Please refer to page 25 for further information.It is important to note that the ability of your GoSafe 2  Mobile Pendant to make a help call may be aected by environmental factors, including building materials, large masses covering the Pendant (i.e. a person laying on top  of it) and submersion in liquid. * Lifeline may not always be able to determine your location. During an alarm, always tell the Response Associate where you are if you are able to do so.Agency Filing Copy
16 Questions? Call 1-800-635-6156Battery informationYour GoSafe 2 Mobile Pendant contains a rechargeable battery that can only be replaced at the Philips factory. Your Pendant will automatically send a silent maintenance signal to Philips Lifeline when the battery needs to be replaced. Philips Lifeline or our representative will contact you directly to make arrangements for a replacement.Equipment serviceEvery GoSafe 2 Mobile Pendant is manufactured to high quality standards, and can only be factory-serviced by Philips Lifeline, with the exception of the neck cord, which can be replaced by the user. You can only replace the neck cord with a Philips replacement neck cord designed specically for your pendant. Your GoSafe 2 Pendant performs periodic diagnostic self-tests to verify proper functionality. If you ever experience issues with your equipment, or if it becomes damaged, please contact Philips Lifeline or your representative to arrange service or a replacement.Contact Philips Lifeline at the number below if: • you would like to transfer your service to a new or  second home;• your Responder or Notify list needs to be updated. It is important that your list is up to date with the correct people and contact information;Agency Filing Copy
17Questions? Call 1-800-635-6156• someone else in your home needs to use the Lifeline Service. More than one person living in the same household can have the service, but each individual user requires their own Pendant.Safety informationThe GoSafe 2 Mobile Pendant uses the AT&T wireless network to communicate with the Lifeline Response Center. 1.   Caution, the strength of the wireless (cellular) signal may be stronger in some areas of your home than others. Be sure to test your Pendant by pressing the Help Button from places where you spend the majority of your time to help to check the Pendant’s ability to connect to to the cellular network from these areas. A successful test will result in a call to the Response Center. Once connected, tell the Response Associate that you are testing your system and that no help is needed and they will reset your Pendant.  2. If the AT&T wireless network experiences an outage or your Pendant loses its signal, it will not be able to send a Help Call to Lifeline. If this happens, dial 911 for emergency assistance. 3. Your Pendant contains a rechargeable battery. It must be suciently charged to send a signal to the Response Center.Agency Filing Copy
18 Questions? Call 1-800-635-6156GoSafe 2 Mobile  Medical Alert System  General InformationThe information in this section applies to the proper use and care of your GoSafe 2 Mobile Pendant. Cleaning and CareYour GoSafe 2 Mobile Pendant is water resistant to the IPX7 standard. This means that you can submerge it in up to 1 meter (about 40”) of water for up to 30 minutes without damaging it. As such, you can submerge it in warm water for easy cleaning and can also bathe/shower without removing it. 1.  Wash the neck cord with a mild liquid detergent such as liquid dish detergent. Replacement neck cords are available from Philips Lifeline for a nominal fee and include a convenient tool that simplies replacement.2. Wash the Pendant under warm running water. You may also gently wipe it with an isopropyl (rubbing) alcohol wipe or a cotton pad moistened with alcohol. However, do not soak it in alcohol or pour alcohol into the microphone or speaker area of the Pendant. (See pages 22-23)3. Blot excess moisture with a towel and allow the Pendant to nish air-drying while you’re wearing it. Agency Filing Copy
19Questions? Call 1-800-635-6156Note: If you accidentally press the Help Button during cleaning, don’t panic. Allow the call to connect. A Personal Response Associate will answer the call when it connects. Simply tell them that “No help is needed”, and conrm to them that you are OK. Warnings• Any cord worn around the neck can pose a strangulation risk, including the possibility of death and serious injuries. This may be of more concern to wearers in wheelchairs, using walkers, using beds with guard rails, or who might encounter other protruding objects upon which the cord can become tangled.• The neck cord on your GoSafe 2 Mobile Pendant employs a special fuse (see image right). This fuse is designed to break away under certain conditions to reduce the risk of strangulation. If this fuse breaks apart, contact Philips Lifeline or your authorized representative for a replacement,  as the fuse cannot be repaired or re-used. • Do not use any neck cord other than the one provided by Philips Lifeline or your representative. Other neck cords may not provide the feature to break apart therefore increasing the risk of strangulation.• Do not tie a knot in your neck cord since this may prevent the break away feature from working properly. • There are no user-serviceable parts inside the Pendant.• Do not attempt to open or modify the Pendant.8235Model: 7000PHB2000148235-YYYYMMDDFCC: BDZ70 00PHBIC: 655C -7000PH B82352000148235-YYYYMMDDFCC: BDZ70 00AHBIC: 655C -7000AH BModel: 7000AHB82352000148235-YYYYMMDDFCC: BDZ7000AHBIC: 655C-7000AHBModel: 7000AHBAgency Filing Copy
20 Questions? Call 1-800-635-6156• The Pendant contains a lithium battery that must be disposed of properly. Do not discard the Pendant in the trash or expose it to ames or intense heat. • The Pendant is not suitable for use in the presence of ammable anesthetic mixtures with air or with oxygen or nitrous oxide. See page 50.• Do not put your Pendant through the dishwasher, clothes washer or dryer. Please be sure to remove your Pendant from articles of clothing that are being dry-cleaned.• Excessive heat may damage your Pendant. Do not leave your Pendant on the dashboard of your car, a window sill or on any other area that receives intense, direct sunlight. Likewise, do not wear your Pendant into a hot tub or sauna. Normal bathing and showering temperatures WILL NOT damage your Pendant. See page 52 for bathing  temperature limits.Agency Filing Copy
21Questions? Call 1-800-635-6156GoSafe 2 Mobile Pendant  (7150MHB) The GoSafe 2 Mobile Pendant allows you to connect to the Lifeline Response Center 24 hours a day,  7 days a week. It can be used at home, or from any other location in the United States where the AT&T wireless network is available.The GoSafe 2 Mobile Pendant includes Philips AutoAlert fall detection technology, which provides an added layer of protection for the user by automatically calling for help when a fall is detected. AutoAlert technology is highly accurate, but does not detect 100% of falls. If you are able, you should always press your Button when you need help. Agency Filing Copy
22 Questions? Call 1-800-635-6156ChargerExcess cord storageFront viewIndicator light – This light will indicate the status of the GoSafe 2 Mobile Pendant. (see: Alarm Descriptions / Summary Tables section.)Microphone – The GoSafe 2 Mobile Pendant has a microphone that is used to talk to the Response Associate Help Button – The Help Button is the portion of your Pendant that can be pressed to send a Help Call to Philips Lifeline. ChargerThe GoSafe 2 Mobile Pendant has a rechargeable battery. Use only the charger provided with your GoSafe 2 system to recharge the Pendant when the light & voice prompts indicate that the Pendant needs to be charged. See the Charging the battery section on page 29.Help ButtonGoSafe 2 Mobile Pendant (7150MHB)Agency Filing Copy
23Questions? Call 1-800-635-6156Back viewSpeaker – The GoSafe 2 Mobile Pendant has a built-in speaker that allows you to hear the Personal Response Associate, voice prompts and alert sounds. Charging Contacts – The gold circles on the back of the Pendant are the charging interface contacts. When you place your Pendant in the Charger, the Charger  Pins engage with these contact points.Agency Filing Copy
24 Questions? Call 1-800-635-6156Item Descripon1 Philips Lifeline Logo2  NuG mTI bN er3 Refer to IFU Icon4  NuSer mia bl er5  NM uod mbel er6 A  p Papl ri te  d Icon7 L  a 4s  t Digits of Serial Number8  D ofa  t Me anufacture9 Engineering Part Number10 Emmission Icon11 Ingress Protecon (IP) Rang12 FCC,IC code13 Product BarcodeTable 1 – Content Details 7150MHBREF    300000012345  SN    1030148235MDL    7150MHB           YYYY-MM-DD0088483807XXXXFCC ID: BDZ7101MHBIC:     655C-7100MHBPhilips Lifeline LogoIngress Protection (IP) Rating GTIN NumberRefer to IFU IconProduct BarcodeApplied Part IconEngineering Part NumberSerial NumberLast 4 Digits of Serial NumberModel NumberFCC,IC codeEmmission IconDate of ManufactureBack view with labeling descriptionAgency Filing Copy
25Questions? Call 1-800-635-6156Determining your locationWhen in Alarm State, the GoSafe 2 Mobile Pendant is designed to help identify your location, at or away from home. However, you should always tell the Personal Response Associate your exact location if you are able to do so. If you are unable to speak or describe your exact location, Lifeline will contact help to nd and assist you where you are. Lifeline cannot guarantee that your location can be determined at all times.If your Responder or emergency services is having trouble locating you, Lifeline may activate the Audio Beacon feature on the pendant. This is a very loud, siren-like noise that will come from the Pendant speaker and will help responders to nd you more easily. Each time the Audio Beacon is activated, it will sound for 5 minutes. Pressing the Help Button will silence the Audio Beacon and will not initiate another Help Call. Agency Filing Copy
26 Questions? Call 1-800-635-6156What to expect when the AutoAlert fall detection technology in your GoSafe 2 Mobile Pendant  detects a fall • A Help Call is automatically generated after approximately 30 seconds of a fall being detected. While the fall may be detected in only a few seconds, the 30 second period is provided for users to “self-recover” from a fall if able.• If the Pendant detects that you have self-recovered from the fall, within less than approximately 30 seconds of a fall being detected, a Help Call will not be generated.• Do not attempt to stand if you feel unable to do so.• Regardless of whether you have fallen or not, if you think you need assistance, always push the Help Button immediately to initiate the Help Call if you are able to do so. Pushing the Help Button promptly generates the Help Call. If your Pendant has detected a fall but 30 seconds have not yet passed, pressing the Help Button WILL NOT cancel the help call. It will promptly send the help call.About Fall Detection Warning The AutoAlert fall detection technology may not detect every fall. In certain situations, the AutoAlert technology may not detect a fall. Some movements may not register as a fall and would not be detected. Examples include, but are not  limited to: Agency Filing Copy
27Questions? Call 1-800-635-6156• A gradual slide such as from a seated position - such as from a wheelchair. • Lowering oneself slowly to the ground• Bracing the impact of a fall or interrupting the fall in-process, such as by holding-on to a piece of furniture during the fall. • A fall from a height of less than 20 inches (0.5 meters)  CautionCertain conditions can aect the ability of the AutoAlert Technology to detect a fall: • If you live at an altitude above 6,600 feet (2000 meters) • If you are less than 4 feet 6 inches in height (1.4 meters) • If you weigh less than 88 pounds (40 kilograms) Any of these conditions can reduce the fall detection capability of the AutoAlert technology. However, the ability to send a help call by pressing the Help Button is not aected by such conditions.  If you fall and need help, always press the Help Button if you are able to do so. Note that if your Pendant did detect the fall and is already in-process of calling Lifeline, pressing the Help Button WILL NOT cancel or interrupt the call already  in-progress, and will not interfere with system operation in  any way. False “fall detected” alarms may occasionally occur While the GoSafe 2 Mobile Pendant is designed to have very few false alarms, a fall detected alarm might occasionally occur when there was not a fall (i.e., a false alarm). This is considered normal operation. If this occurs, don’t panic.  Agency Filing Copy
28 Questions? Call 1-800-635-6156Allow the call to connect. A Philips Response Associate will answer the call when it connects. Simply tell them that “No help is needed”, and conrm to them that you are OK. There are no additional charges for false alarms. Note: Occasional false alarms do not indicate that the Pendant is malfunctioning. The vent area located on the back of the Pendant is part of the AutoAlert fall detection sensor system and needs to remain clear of obstructions (e.g., lint or food products). A continuous ow of water (e.g., a shower) hitting the vent directly may also temporarily obstruct it. However, your Pendant should be worn at all times as it is waterproof for showering and bathing. CautionPotential InterferenceDo not use the GoSafe 2 Mobile Pendant if you have an implantable cardiac device, such as a debrillator or pacemaker. The GoSafe 2 Mobile Pendant may interfere with certain medical equipment, such as magnetic resonance imaging (MRI), X-ray machines, Automatic External Debrillators, cardiac monitors, pacemakers, insulin pumps, and hearing aids. It may also interfere with metal detectors.  Air TravelBecause it is a cellular communication device, the GoSafe 2 Mobile Pendant may interfere with aircraft communications Back view vent areaAgency Filing Copy
29Questions? Call 1-800-635-6156while in normal Stand-by mode. For this reason, the Pendant has a Sleep Mode. Be sure to place your Pendant in sleep mode during air travel. Please see instructions for putting your Pendant in Sleep Mode on page 32.The GoSafe 2 Mobile Pendant can only place a Help Call  when in Stand-by mode, and when the AT&T wireless  network is available and when it has sucient battery charge.Charging the batteryYour GoSafe 2 Mobile Pendant is powered by a rechargeable battery. This means that it must be re-charged regularly, as indicated, for proper function. The Pendant will chime once and the Indicator Light will ash orange whenever the Pendant initially needs to be charged. Typically, it will take less than 45 minutes to charge your GoSafe 2 Mobile Pendant if you put it in the charger at this initial charge indication point. It will take longer than this if you wait additional time after this indication point to put the Pendant in the charger. Your Pendant is fully charged when it chimes and the Indicator Light turns to a steady green. If you do not charge the Pendant at the time of Initial Charge Indication, the battery charge will continue to deplete and the orange light will continue to blink. Once it reaches a critical power state, the Pendant will reach the Critical Charge Indication. When this happens, the Pendant will play a voice prompt: “Your Help Button is now out of power and will shut down. Please charge your device as soon as possible”. It may take more than one hour to charge your Pendant if it reaches this point, but this will not hurt  the device.  Agency Filing Copy
30 Questions? Call 1-800-635-6156 Warning: once the Critical Charge Warning is played and the Pendant shuts down, it cannot be used to make a help call of any type until it is re-charged. Flashing  orange Indicator Light = charging neededFlashing green  Indicator Light  = charging  in progressWhen connected  to the charger, a steady green Indicator Light  = fully chargedWhen charging:1.  Make sure the charger is plugged into a power outlet (wall plug) that is receiving power. For this reason, we do not recommend plugging the charger into outlets controlled by a wall switch, or power strips unless you can conrm that they are powered on.2. Attach your Pendant to the Charger. You will hear a chime and a voice prompt that says “I am now charging. Agency Filing Copy
31Questions? Call 1-800-635-6156My light will turn solid green when I am ready to use.” to acknowledge that you are charging. The Indicator Light will begin ashing Green. 3. Charge until the Indicator Light shines a steady green.  4. Remove from the charger. The green Indicator Light will turn o, and the Pendant is ready to use.5. To provide the User with the longest possible battery life between charges, there is no constantly illuminated power indicator. Instead, the Pendant includes a “shake to indicate” feature. To determine if your Pendant is powered on, hold it in your hand and shake it briey, watching the Indicator Light while shaking.  • A ashing green Indicator Light when shaken means that  the Pendant has sucient battery power for  normal operation.• No ashing green Indicator Light means that the battery is dead and needs to be charged, or that the Pendant is in  sleep mode.Important reminders • You should continue wearing your Pendant while it is being charged. Please be cautious not to trip on the Charger power cord while doing so.• When you are charging your Pendant while wearing it, be sure to remove it from the Charger prior to standing up. Failure to do so may compromise the fall detection capability of your Pendant. • Do not charge your Pendant while sleeping or bathing.Agency Filing Copy
32 Questions? Call 1-800-635-6156• Battery life varies based on activity level, cellular signal strength in your area, battery age, and actual emergency use. Your GoSafe 2 Mobile Pendant provides audible and visual reminders of when to charge. You should charge it when it indicates charging is needed. Depending on environmental conditions and your level of mobility, you will have to charge your GoSafe 2 Pendant once every 2-3 days.Sleep modeThe GoSafe 2 Mobile Pendant utilizes cellular communication technology. As such, you must turn it o in the following circumstances: • During Air Travel (when ying on an airplane) your Pendant must be placed in Sleep Mode. This is true regardless of whether you are “carrying-on” the pendant into the passenger cabin, or if you pack the Pendant in your checked luggage. • If you are returning the Pendant to LifelineThe Pendant has a Sleep Mode for these situations. To put the Pendant into sleep mode, press and hold down the Help Button for 10 seconds. Your Pendant will say: “If you would like to turn o your Help Button, please press it again.” Release the Help Button and then press and release it again without holding it down. The Pendant will conrm it is entering sleep mode by saying: “Your Help Button is now turning o.”You should take the Pendant out of Sleep Mode as soon as conveniently possible upon exiting the plane to allow it to  Agency Filing Copy
33Questions? Call 1-800-635-6156re-orient to its new location. To exit Sleep Mode, press  the Help Button once and release it. Your Pendant will say: “Your Help Button is now ready to use. If you need help, please press your Help Button again”. This initial button press that wakes the Pendant out of sleep mode will not initiate a Help Call. If you need help in this instance, be sure to press the  Help Button a second time.  CautionYou will not be able to send a Help Call when the Pendant is in Sleep Mode. Be sure to remember to exit Sleep Mode as soon as wireless/electronic device use is allowed, e.g., after the airplane has landed.Note: If you are returning a GoSafe 2 Mobile Pendant to Philips Lifeline for service, replacement or recycling, you must contact Philips Lifeline at the number at the bottom of the page prior to returning it. Philips Lifeline will provide you with special packaging and instructions for return to help ensure that the Pendant does not send help signals while in-transit. Do not ship the Pendant without notifying Philips Lifeline that you are  doing so. Recommended usage• Press the Help Button on your Pendant any time you need help, or in situations/locations outside the home where you want to determine if the AT&T wireless network is available.• Wear your Pendant at ALL times, at and away from home. The GoSafe 2 Mobile Pendant can send a Help Call from any location where the AT&T wireless network is available.Agency Filing Copy
34 Questions? Call 1-800-635-6156• During an alarm, you can talk to Philips Lifeline using the microphone and speaker on your Pendant. For best results, hold the Pendant up and away from your chest when you are speaking to Lifeline. Maintain a minimum separation distance of 10mm/0.394 inches when operating the device in this manner. 10mm is less than the thickness of your nger.  • Your GoSafe 2 Mobile Pendant should be worn while showering or bathing. The Pendant has an IPX7 waterproof rating. This means that it can be submerged to a depth of 1 meter (40”) in water for up to 30 minutes. It is not designed for submersion deeper than 1 meter for any period of time, and should not be left submerged under water at any depth up to and including one meter for longer than 30 minutes. • Do not throw or toss the Pendant onto a bed, table, or other surface because it may interpret this as a fall and accidentally send a Help Call. • Your Pendant may be worn outside of or underneath your clothing depending on your preference. Regardless, it must always be worn as a pendant to help provide  proper function.• Your Pendant can be used while driving. However, when entering and exiting your vehicle, take care to prevent the Pendant from hitting the steering wheel because it may accidentally send a Help Call. Agency Filing Copy
35Questions? Call 1-800-635-6156GoSafe 2 Mobile Pendant – AlarmsIntroduction There are two types of alarms processed by the GoSafe 2 Mobile Pendant.• High Priority – Require immediate response  (by the Response Center)• Medium Priority – Require prompt response  (by the operator/user)Additionally, the Pendant also plays verbal informational messages and conrmation alerts that notify you of conditions that need attention but do not qualify as alarm conditions (e.g. installation prompts).Note: If multiple alarms occur at the same time, all alarms are processed and displayed, but the alarms are ordered rst by priority and then by occurrence, with the newest, highest priority alarms at the top of the list. The alarm precedence is in the following order: high priority, medium priority, and informational messages.Note: Not all alarms are available in every mode (e.g. during installation); some alarms are mode-dependent.Audible and Visual Alarm Indicators When the Pendant detects a High priority alarm: The Indicator Light on the Pendant ashes red, the device audible alarm sounds and a recorded voice message is played.When the Pendant detects a Medium priority alarm: The light on the Pendant ashes orange, the Pendant may play a chime and/or a voice prompt.Agency Filing Copy
36 Questions? Call 1-800-635-6156Silencing Alarms Once a High Priority alarm is detected, it cannot be silenced.During Medium Priority alarms, the Pendant will play a sound and possibly a voice prompt once upon detection of the alarm, but the red Indicator Light ashes until the alarm condition is corrected.Resetting an Alarm – what does reset mean?High Priority alarms are normally reset (cancelled once addressed) by the Response Center after the alarm has been addressed. Additionally, the Pendant may periodically poll the Response Center to see if the alarm should be reset and does so accordingly. If the alarm is not reset by the Response Center, the Pendant will automatically reset the alarm after 30 minutes.Note: Putting the GoSafe 2 Mobile Pendant into Sleep Mode during an active high priority alarm will reset the device, canceling the alarm. However, a prolonged (10 seconds) button press is required to put the Pendant into Sleep Mode and a Voice Message is played requiring the user to conrm this action by pressing the Help Button again to actually enter Sleep Mode. Since the alarm likely has already been reported to the Response Center, Philips Lifeline will likely attempt to contact the Subscriber via alternative means if this happens - such as by calling the home phone or cell phone of the user. If they are not able to contact the user, the Response Center will begin to facilitate response. If an alarm is accidentally initiated by the User, they should not put the Pendant in Sleep Mode to try to cancel the alarm. Instead, the User should wait for the Response Center  Agency Filing Copy
37Questions? Call 1-800-635-6156to establish voice communication and simply state that no help  is needed.The GoSafe 2 Mobile Pendant self-cancels certain Medium Priority alarms if the cause of the alarm is corrected, stopping the orange ashing Indicator Light from illuminating.Alarm Descriptions / Summary TablesHelp Needed – 7150 MHBAlarm Event DescriptionHelp Alarm initiated by the User pressing the Help Button on the End Device.Priority HighDevice Action Operates normallyAlarm Event Reported/ Displayed Locally?Yes. Upon pressing the Help Button on the End Device, a Voice Message plays and the Indicator Light LED ashes red.Alarm Event Reported to Philips Lifeline?Yes. A Help Alarm Signal is sent to the Response Center by the End Device from anywhere wireless signal is available on the AT&T wireless network. Upon receiving the Help Signal, the Response Center calls the End Device to establish contact with the Subscriber and to see what kind of help they need.Agency Filing Copy
38 Questions? Call 1-800-635-6156Help Needed – No Cell Signal AvailableAlarm Event DescriptionHelp Alarm initiated by the User pressing the Help Button on the End Device or by the End Device detecting a fall; and the AT&T wireless network is unavailable: a verbal warning message is delivered by the End Device.Priority HighDevice Action The Help Alarm Signal will be buered in the End Device. The End Device will continue to try to connect to the network and deliver the alarm. It will re-announce the voice prompt every 5 minutes until: the condition is corrected and the alarm signal is delivered, or, 30 minutes has elapsed, or, the battery is exhausted. Alarm Event Reported/ Displayed Locally?Yes. Upon pressing the Help Button on the End Device or when the End Device has detected a fall, a Voice Message plays: “Your call cannot be connected. There is no signal strength. Please move to another area.” The Indicator Light ashes red. This is an alarm that will self-cancel once connection to the AT&T wireless network is re-established.Alarm Event Reported to Philips Lifeline?No. If the AT&T wireless network is unavailable  a Help Alarm Signal cannot be sent to the Response Center.Agency Filing Copy
39Questions? Call 1-800-635-6156Help Needed – Fall Detected by PendantAlarm Event DescriptionHelp Alarm initiated by the End Device detecting a fall.Priority HighDevice Action Operates normallyAlarm Event Reported/ Displayed Locally?Yes. When the End Device has detected a fall, it plays a Voice Message and the Indicator Light ashes red. Voice Message: “Your help call is in progress.  Please wait. For proper use, hold your help button up in front of you.”Alarm Event Reported to Philips Lifeline?Yes. The End Device sends a "fall detected" Help Alarm Signal to the Response Center from anywhere wireless signal is available on the AT&T wireless network. Upon receiving the "fall detected" Help Signal, the Response Center calls the End Device to establish contact with the Subscriber and to see what kind of help they need.Agency Filing Copy
40 Questions? Call 1-800-635-6156Device Error (Medium Priority) Alarms The GoSafe 2 Mobile Pendant alarms described below are automatically generated alarms designed to periodically let the Response Center know that the Pendant is working properly They are part of normal operation and are not the result of intentional action by the User. Alarm Event TypeLow Battery Capacity – 7150 MHBAlarm Event  DescriptionWhen the storage capacity of the battery in the End Device has diminished materially and should be replaced, a Warning Message is displayed.Priority MediumDevice Action Charge cycle frequency increases. Otherwise operates normally until battery is depleted.Alarm Event Reported/Displayed Locally?No.Alarm Event Reported to Philips Lifeline?Yes. A silent Maintenance Signal is sent to the Response Center by the End Device. Upon receiving the Maintenance Signal, the Response Center prioritizes the response and contacts the Subscriber to verify the status of  their equipment.Agency Filing Copy
41Questions? Call 1-800-635-6156Battery Requires Charging – 7150MHBAlarm Event DescriptionWhen the rechargeable battery in the End Device needs to be charged, a visual and audible warning Message is activated on the End Device.Priority MediumDevice Action Operates normally until the battery is critically low.Alarm Event Reported/ Displayed Locally?Yes. The Indicator Light ashes orange and a  single chime is played. This alarm will self cancel once the battery charge reaches an  acceptable level.Alarm Event Reported to Philips Lifeline?No.Depleted Battery – 7150 MHBAlarm Event DescriptionWhen the charge level of the rechargeable battery in the End Device is critically low, a Warning Message is announced.Priority MediumDevice Action End Device shuts-down after the message is announced. Alarm Event Reported/ Displayed Locally?Yes. Indicator Light ashes orange, Voice Prompt plays: “Your help button is now out of power and will shut down. Please charge your device as soon as possible”. This alarm will self cancel once the battery charge reaches an acceptable level.Alarm Event Reported to Lifeline?Yes. A silent Maintenance Signal is sent to the Response Center by the End Device from anywhere wireless signal is available on the AT&T wireless network. Upon receiving the Maintenance Signal, the Response Center stores the status information but no direct action is taken.Agency Filing Copy
42 Questions? Call 1-800-635-6156Device Hardware Failure – 7150 MHBAlarm Event  DescriptionIn the event that internal diagnostics indicate that the End Device has a Hardware Error, a Warning Message is displayed, if possible, based on the nature of the failure.Priority MediumDevice Action May have limited operation, depending on  the nature of the failureAlarm Event Reported/Displayed Locally?No.Alarm Event Reported to Philips Lifeline?Yes. A silent Maintenance Signal is sent to the Response Center if the nature of the failure does not impair the signal transmission function. Upon receiving the Maintenance Signal, the Response Center prioritizes the response and contacts the Subscriber to verify the status of their equipment. Agency Filing Copy
43Questions? Call 1-800-635-6156Software Failure-End Device 7150 MHBAlarm Event DescriptionIn the event that an End Device senses it has a software error, a warning message may be sent to the Response Center depending on the nature of the error. Priority MediumDevice Action May have limited operation, depending on  the failureAlarm Event Reported/Displayed Locally?NoAlarm Event Reported to Lifeline?Yes. A silent maintenance signal is sent to the Response Center if the nature of the error does not impair signal transmission function. Upon receiving the maintenance signal, the Response Center prioritizes the response and contacts the Subscriber to verify the status of their equipment. If the End Device is not capable of sending a signal due to the nature of the error, exception reporting at the Response Center that does not require a signal from the End Device will identify the device as requiring maintenance action. Agency Filing Copy
44 Questions? Call 1-800-635-6156Supervision and Check-in Alarms (Informational Messages) The alarms described below are automatically generated alarms designed to periodically let the Lifeline Response Center know that the End Device is working properly. These alarms are silent and require no immediate action from the User/Subscriber.Alarm Event TypeAuto Test Call 7150 MHBAlarm Event  DescriptionAuto Test calls are automatically generated silent alarms sent by the End Device at regular intervals to the Response Center. They are designed to conrm proper End Device operation. Priority N/ADevice Action Operates normallyAlarm Event Reported/Displayed Locally?No visual or audible alarm is generated by the device.Alarm Event Reported  to Philips Lifeline?Yes. A silent Maintenance Signal is sent to the Response Center by the End Device. Upon receiving the Maintenance Signal, the Response Center prioritizes the response and contacts the Subscriber to verify the status of their equipment. In certain cases, the absence of Auto Test Calls from the End Device may indicate the need for maintenance. In either case, the subscriber is contacted to verify the status of their equipment.Agency Filing Copy
45Questions? Call 1-800-635-6156Delay in Determining Alarms  Reporting high priority help alarms from the GoSafe 2 Mobile Pendant to the Lifeline Response Center is done promptly when generated by a button press, depending on the status of the cellular network and signal strength available. The GoSafe 2 Mobile Pendant provides an added layer of protection. It is designed to detect falls under certain conditions. It takes approximately 35-40 seconds to determine that an activity that resembles a fall has occurred, and that the User has not recovered from the fall on their own. If a fall is detected, the signal is sent directly to the Response Center via the AT&T wireless nework, if available.Logging AlarmsAll alarm events reported to the Response Center are logged by the Response Center. There are no User accessible logs.Agency Filing Copy
46 Questions? Call 1-800-635-6156Safety and Regulatory ComplianceIEC regulationsThe GoSafe 2 Mobile Pendant (7150MHB) complies with the relevant National and International standards listed in the Technical Section. It is classied as medical electrical (ME) equipment in the USA according to the FDA product classication. According to Health Canada the GoSafe 2 Mobile Pendant (7150MHB) is not classied as a medical device. It falls under the Canada Consumer Product Safety Act.Device classicationThe GoSafe 2 Mobile Pendant (7150MHB) is registered as an FDA Class II device. It is an internally powered device for continuous operation.Radio specicationsThe GoSafe 2 Mobile Pendant (7150MHB) complies with the FCC Parts 15, 22 and 24 Subparts B, C and E. Its radio transmitters have the following characteristics:• Cellular 3G (824-849MHz and 1850-1910MHz transmission bands).• Bluetooth ISM band 2.4GHz; maximum EIRP 2 dBm, GFSK modulation• WiFi (a, b, g) ISM bands 2.4GHz and 5GHz; maximum EIRP 15 dBm;  OFDM modulationFCC Notice to UsersThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:1) Device may not cause harmful interference2) Device must accept any interference received, including interference that may cause undesired operation.Pursuant to Part 15.21 of the FCC Rules, any changes or modications not expressly approved by Philips Healthcare, Home Monitoring, Lifeline Systems Inc. could void the user’s authority to operate the equipment. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modications to this equipment.Agency Filing Copy
47Questions? Call 1-800-635-6156Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.Radio interference The equipment complies with FCC RF radiation exposure limits set forth of an uncontrolled environment. For hand-held/body-worn operation, this equipment has been tested and meets the FCC RF exposure guidelines. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Use of other accessories may not ensure compliance with FCC RF guidelines.Do not attempt to repair of modify this equipment. Any repairs or alterations made by the user to the equipment may void the warranty and compliance of the equipment. Changes or modications made to this equipment not expressly approved by Philips may void the FCC authorization to operate this equipment. For assistance visit our website www.philips.com/support or call toll-free 1-800-635-6156.Industry Canada Notice to Users This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:1) Device may not cause interference2)  Device must accept any interference, including interference that may cause undesired operation of the device.Agency Filing Copy
48 Questions? Call 1-800-635-6156Le présent appareil est conforme aux CNR d’Industrie Canada applicables  aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:• l’appareil ne doit pas produire de brouillage• l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si  le brouillage est susceptible d’en compromettre le fonctionnement.Class B digital device notice This Class B digital apparatus complies with Canadian ICES-003, RSS-Gen  and RSS-210.Cet appareil numérique de la classe B est conforme à la norme NMB-003,  CNR-Gen et CNR-210 du Canada.Essential performanceThe GoSafe 2 Mobile Pendant (7150MHB) provides essential performance (EP) under normal operating conditions (includes EMC exposure) by sending Help Calls to the  Lifeline Response Center. If the Pendant is unable to signal to the Response Center, exception reporting at the Response Center will identify the issue in the absence of  a device signal. Intended UseThis Philips product is intended to be installed, used and operated only in accordance with the safety procedures and operating instructions provided in, the Quick Setup Guide and these Instructions for Use for the purpose for which it was designed. The purpose for which the product is intended is given below.The GoSafe 2 Mobile Pendant (7150MHB) is intended to be worn as a pendant and is capable of detecting certain types of falls or being activated manually. The GoSafe 2 Mobile Pendant (7150MHB) is designed to directly connect to an emergency help service via the AT&T wireless network.Uses of the GoSafe 2 Mobile System for purposes other than those intended and expressly stated by Philips Lifeline, as well as incorrect use or operation, may relieve Philips Lifeline (or its agent) from all or some responsibility for resultant non-compliance, damage or injury.Agency Filing Copy
49Questions? Call 1-800-635-6156Contraindications CautionThis device may be contraindicated for any person who is connected to, or has implanted in their body, an a implanted electronic medical device or instrument such as a pacemaker or debrillator. This device may cause the electronic medical device  to malfunction. Philips Lifeline makes no claims or warranties, implied or otherwise, regarding the suitability of this equipment for use with said implantable electronic medical devices, or any inter-compatibility for concurrent operation thereof. Users who have such devices implanted in their body and chose to use this equipment despite these stated Contraindications do so at their own risk and without the consent of Philips Lifeline. In no case may Philips Lifeline be held liable for events arising from use of this equipment concurrent with said implantables within their body. CompatibilityThe products described in this manual are compatible only with the components described herein and should not be used in combination with any other products or components unless such other products or components are expressly recognized as compatible by Philips Lifeline.Changes and/or additions to the product should only be carried out by Philips Lifeline or by third parties expressly authorized by Philips Lifeline to do so. Such changes and/or additions must comply with all applicable laws and regulations that have the force of law within the jurisdiction(s) concerned, and with best engineering practice. WarningChanges and/or additions to the product that are carried out by persons without the appropriate training and/or using unapproved spare parts will void the warranty. As with all complex technical products, maintenance by persons not appropriately qualied and/or using unapproved spare parts carries serious risks of damage to the product and of personal injury.Risks and BenetsThe GoSafe 2 Mobile Pendant (7150MHB) depends on connecting to the AT&T wireless network in order to communicate with the Philips Lifeline Call Center. As with all wireless devices, the availability of the network cannot always be guaranteed. The GoSafe 2 Mobile Pendant (7150MHB) depends on the user being capable of pressing the Help Button when they are in need of help and (re) charging the Pendant when necessary for proper operation.Agency Filing Copy
50 Questions? Call 1-800-635-6156Safety Warnings  Maintenance & faults: If any part of the product is known (or suspected) to be defective or wrongly adjusted, DO NOT USE the product until a repair has been made. Operation of the product with defective or wrongly adjusted components could expose the user or the patient to safety hazards. Safety awareness: Do not use this product for any application until you read and understand the safety information, safety procedures and emergency procedures contained in this SAFETY section. Operation of the product without a proper awareness of how to use it safely could lead to fatal or other serious personal injury. Safety devices: Never attempt to remove, modify, or otherwise defeat any safety device on the product. Interfering with safety devices could lead to fatal or other serious personal injury.Intended use and compatibility: Do not use this product for any purpose other than those for which it is intended. Do not use the product with any product other than that which Philips Lifeline recognizes as compatible. Operation of the product for unintended purposes, or with incompatible product, could lead to fatal or other  serious injury. Electrical safety Warnings  • Do not remove covers or cables from the provided power supply adapter. Dangerous electrical voltages are present within this product. Removing covers or cables could lead to serious or fatal personal injury. • Covers or cables should only be removed by qualied and authorized  service personnel. Explosion safety Warnings  • Do not use this product in the presence of explosive gases or vapors, such as certain anesthetic gases. • Do not use ammable or potentially explosive disinfecting sprays in the presence of this product.• Use of this product in an environment for which it was not designed can lead to re or explosion.Agency Filing Copy
51Questions? Call 1-800-635-6156 CautionPortable and Mobile Phones: Portable and mobile RF communications can aect the GoSafe 2 Mobile Pendant (7150MHB). Use caution when using such communication devices within the specied range of the GoSafe 2 Mobile Pendant (7150MHB). Refer to Table 6 in the EMC section (page 58) for the required separation distances between portable and mobile RF communications equipment and this device.MaintenanceExpected Service Life The Expected Service Life of the GoSafe 2 Mobile Pendant is as follows:• GoSafe 2 Mobile Pendant (7150MHB) – 2-3 years**The Service Life indicated above is primarily based on the expected life of the device’s internal battery. Actual performance may vary depending upon conditions such as battery charge cycling, temperature, cell signal strength in your area and other factors.Power Supplies, Extension Cords and Power strips Do not use extension cords or power strips with this device.Biocompatible materials, Latex-Free This product does not contain natural latex rubber or dry natural rubber in user or operator accessible areas. All materials of construction of this product that come into contact with the skin of the User during normal use are certied biocompatible, per ISO 10993-1, Part 1.Passing the product on to another user As a medical device, and due to the potential for bio-hazardous materials to contaminate the device, this  product cannot be passed to another user by an existing user or re-sold to another user. Please see the Terms and Conditions of Use for more information. In the event the original user wishes to end their service, they must call Philips Lifeline to cancel their service. Technical SpecicationsStandards ComplianceThis device is designed to conform to the following Standards and Regulations:• IEC/ANSI/ AAMI60601-1:2005/R(12)2012, 3rd edition, Part 1- General requirements for basic safety and essential performance.’ Agency Filing Copy
52 Questions? Call 1-800-635-6156• CSA C22.2 # 60601-1:2014 Ed.3 Medical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance• IEC 60601-1-2, 3rd Edition (2007-03), General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests• IEC 62366, 1st Edition (2015), ‘Medical devices – Application of usability engineering to medical devices’• IEC 60601-1-6, 3rd Edition (2013), ‘Collateral standard: Usability’• IEC 60601-1-8, 2nd Edition (2006), ‘Collateral standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems’ • IEC 60601-1-11, 2nd Edition (2015) ‘Collateral standard: Requirements for  medical electrical equipment and medical electrical systems used in the home healthcare environment’• ISO 10993-1 Biological evaluation of medical devices - Part 1: Evaluation and testing (Biocompatibility)• ISO 14971, 2nd Edition (2007), ‘Medical devices – Application of risk management to medical devices’.Open source softwareThe GoSafe 2 Mobile Pendant (7150MHB) utilizes the Wiced™ SDK and associated third party, open-source code and object les which are used under license from their respective providers within the SDK. Wiced is a trademark of Cypress Semiconductor Corporation.Environmental RatingsOperating Storage Bathing*Temperature 32° F to 104° F  (0° C to 40° C)-4° F to 140° F  (-20° C to 60° C)Up to 122° F  (50° C)* Relative  Humidity10 to 90%  (non-condensing)10 to 90%  (non-condensing)10 -90%  (non-condensing)Atmospheric Pressure101 kPa to 80 kPa (approximately 0-6600 ft/0-2000 m)N/A 101 kPa to 80 kPa (approximately 0-6600 ft/0- 2000 m)Altitude 6,600 feet (2 km) MaximumN/A 6,600 feet (2 km) Maximum  * Up to 30 minutes exposure.Agency Filing Copy
53Questions? Call 1-800-635-6156Electrical SpecicationsGoSafe 2 Mobile Pendant (7150MHB)AC Voltage Source[1] (VAC) N/A - EUT battery operated. AC battery charger adapter 100-240Vac 50/60Hz, 0.5ADC Power Source (VDC) 3.7 V, 920mAh[2], Lithium Ion Rechargeable [3] Battery Type of Protection Against Electric ShockClass II (Power Supply Adapter)/GoSafe 2 is Battery operatedDegree of Protection Against Electric ShockType BF Applied PartDegree of Protection Against Ingress of WaterWater Resistant (1 meter, for 30 Minutes), IPX7Mode of Operation Continuous OperationSound Pressure Level 116-123 dB at 1 kHz (measured 1 cm from the speaker)[1] The means of isolating the device from the supply mains is by disconnecting the device from the  wall outlet. [2] The capacity restored by the cell varies according to current drain, temperature and cut-o.[3] Recharging of the GoSafe 2 Mobile Pendant (7150MHB) battery is done by the user as needed, when connected to the charger.Agency Filing Copy
54 Questions? Call 1-800-635-6156Product Disposal – Environmental RequirementsIntroduction Philips Lifeline is committed to protecting the natural environment, and to helping to provide for the continued safe and eective use of this product, through proper support, maintenance and training. Therefore, Philips Lifeline products are designed and manufactured to comply with relevant guidelines for environmental protection. As long as the product is properly operated and maintained, it presents no environmental risks. However, the product may contain materials, which could be harmful to the environment if disposed of incorrectly. Use of such materials is essential to performing the functions of the product, and to meeting statutory and other requirements. Final disposal of the product “Final Disposal” refers to the point at which the User disposes of the product in such a way that it can no longer be used for its intended purpose. In the event a User wishes to end their service or no longer needs the GoSafe 2 Mobile Pendant (7150MHB) and Charger, User may return the device to Philips Lifeline or its representative for proper disposal.Philips supports Users in:• Recovering reusable parts,• Recycling of useful materials by competent disposal companies, and, • The safe and eective disposal of this product.Electromagnetic Comparability – EMC Medical electrical equipment can either generate or receive electromagnetic interference. The GoSafe 2 Mobile Pendant (7150MHB) has been evaluated for electromagnetic compatibility (EMC) with the appropriate accessories according to IEC 6060-1 collateral standard IEC 60601-1-2:2007, the international standard for EMC for medical electrical equipment.The GoSafe 2 Mobile Pendant (7150MHB) complies with relevant laws and standards on electro-magnetic compatibility (EMC) for this type of product when used as intended. Such laws and standards dene both the permissible electromagnetic emission levels  from this product and its required immunity to electromagnetic interference from external sources.The GoSafe 2 Mobile Pendant (7150MHB) must emit electromagnetic energy in order to perform its intended function. Nearby electronic equipment may be aected. Medical  Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the accompanying documents.Agency Filing Copy
55Questions? Call 1-800-635-6156Other electronic products exceeding the limits dened in such EMC standards could, under unusual circumstances, aect the operation of the product.1.  Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the Accompanying Documents.2.  Other equipment such as Portable and Mobile RF Communications Equipment may interfere with the medical device even of the other equipment complies with CISPR emission requirements .3.  The use of accessories and cables other than those specied, with the exception of those sold by the manufacturer may result in increased emissions or decreased immunity of the equipment or system.4.   The equipment or system should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, the equipment or system should be observed to verify normal operation in the conguration in which it will be used.EMC Informational Tables Table 1 – Guidance and Manufacturer’s Declaration – Emissions  The GoSafe 2 Mobile Pendant (7150MHB) is intended for use in the electromagnetic environment specied below. The GoSafe 2 Mobile Pendant (7150MHB) is provided with battery power adapter charger. The customer or User of the GoSafe 2 Mobile Pendant (7150MHB) should ensure that it is used in such an environment.Emissions Test Compliance Electromagnetic Environment – GuidanceRF Emissions CISPR 11Group 2 The GoSafe 2 Mobile Pendant (7150MHB) must emit Electromagnetic energy in order to perform its intended function. Nearby electronic equipment may be aected.RF Emissions CISPR 11Class BHarmonics IEC 61000-3-2N/A for GoSafe 2. Class A for chargerThe GoSafe 2 Mobile Pendant (7150MHB)  is Battery Powered. The GoSafe 2 Mobile Pendant (7150MHB) power charger is suitable for use in all establishments, including domestic, and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.Flicker IEC 61000-3-3CompliesAgency Filing Copy
56 Questions? Call 1-800-635-6156Table 2 – Guidance and Manufacturer’s Declaration – Immunity  The GoSafe 2 Mobile Pendant (7150MHB) is intended for use in the electromagnetic environment specied below. The User of the GoSafe 2 Mobile Pendant (7150MHB) should ensure that it is used in such an environment.Immunity Test EN/IEC 60601  Test LevelCompliance LevelElectromagnetic Environment – GuidanceElectrostatic Discharge (ESD) EN/IEC 61000-4-2±6kV Contact  ±8kV Air±6kV Contact  ±8kV Air Floors should be wood, concrete or ceramic tile. If oors are synthetic the relative humidity should be at least 30%Electrical fast transient/burst EN/IEC 61000-4-4(only for battery charger power supply)±2 kV for power supply lines ±1 kV for input/output lines±2 kV for power supply linesElectrical power quality should be that of a typical commercial or hospital environment.Surge EN/IEC 61000-4-5(only for battery charger power supply)±1 kV line(s) to line(s)±2 kV line(s) to earth±1 kV line(s) to line(s)±2 kV line(s) to earthMains power quality should be that of a typical commercial or hospital environment.Power Frequency 50/60Hz Magnetic Field EN/IEC 61000-4-83A/m 3A/m Power frequency magnetic elds should be that of a typical commercial or hospital environment. Voltage dips,short interruptionsand voltage variations on power supply input lines EN/IEC 61000-4-11(only for battery charger power supply)<5% UT  (>95% dip in UT) for 0.5 cycle. 40% UT (60% dip in UT) for 5 cycles.70% UT (30% dip in UT) for 25 cycles 5% UT (>95% dip in UT) for 5 sec.<5% UT  (>95% dip in UT) for 0.5 cycle. 40% UT (60% dip in UT) for 5 cycles. 70% UT (30% dip in UT) for 25 cycles 5% UT (>95% dip in UT) for 5 sec.Electrical power quality should be that of a typical commercial or hospital environment. During charging, if the the User of the GoSafe 2 Mobile Pendant (7150MHB) requires continued operation during power mains interruptions, it is recommended that the device power adapter is powered from an uninterrupted power supply or a battery.NOTE: UT is the ac mains voltage prior to application of the test level. Agency Filing Copy
57Questions? Call 1-800-635-6156Table 4 – Guidance and Manufacturer’s Declaration – Immunity  The GoSafe 2 Mobile Pendant (7150MHB) is intended for use in the electromagnetic environment specied below. The customer or user of the GoSafe 2 Mobile Pendant (7150MHB) should ensure that it is used in such an environment.Immunity TestEN/IEC 60601 Test LevelCompliance LevelElectromagnetic Environment – GuidanceConducted RF EN/IEC 61000-4-63 Vrms 150 kHz to 80 MHz3 Vrms* D=1.17√P D=0.35√P 80 to 800 MHzD=0.70√P 800 MHz to 2.5 GHzRadiated RF  EN/IEC 61000-4-310 V/m  80 MHz to 2.5 GHz10V/m Portable and mobile communications equipment should be separated from the GoSafe 2 Mobile Pendant (7150MHB) by no less than the distances calculated/listed below*:D=(3.5/V1)(√P) D=(3.5/E1)(√P) 80 to 800 MHz D=(7/Eq)(√P) 800 MHz to 2.5 GHzWhere P is the maximum power in watts (W) and D is the recommended separation distance in meters (m).Field strengths from xed RF transmitters, as determined by an electromagnetic site survey,(a) should be less than the compliance level in each frequency range.(b)Interference may occur in the vicinity of equipment marked with the following  symbol: NOTE: Conducted RF Immunity does not apply to an internal battery operatedNOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is aected by absorption and reection from structures, objects and people.(a) Field strengths from xed transmitters, such as base stations for radio (cellular/ cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to xed RF transmitters, an Agency Filing Copy
58 Questions? Call 1-800-635-6156electromagnetic site survey should be considered. If the measured eld strength in the location in which the GoSafe 2 Mobile Pendant (7150MHB) is used exceeds the applicable RF compliance level above, the GoSafe 2 Mobile Pendant (7150MHB) should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the GoSafe 2 Mobile Pendant (7150MHB).(b) Over the frequency range 150 kHz to 80 MHz, eld strengths should be less  than 3 V/m.Table 6 – Recommended Separations Distances between Portable and Mobile RF Communications equipment and the GoSafe 2 Mobile Pendant (7150MHB)  The GoSafe 2 Mobile Pendant (7150MHB) is intended for use in the electromagnetic environment in which radiated disturbances are controlled. The customer or user of the this device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF Communication Equipment and the GoSafe 2 Mobile Pendant (7150MHB) as recommended below, according to the maximum output power of the communications equipment.Max Output Power (Watts)Separation (m) 150kHz to 80MHz  d = 1.17√P*Separation (m) 80 to 800MHz  d = 0.35√PSeparation (m) 800MHz to 2.5GHz d = 0.70√P0.01 0.117 .035  .07 0.1 0.37 .11068 .2213611.17 .35 .710 3.7 1.1068 2.2136  100 11.7 3.5 7For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is aected by absorption and reection from structures, objects, and people.Agency Filing Copy
59Questions? Call 1-800-635-6156Symbols Symbol DescriptionSymbol for dc (direct current) power.Polarity symbol. Indicates that the center (tip) of the output plug is Positive (+) and the barrel of the output plug is Negative (-).The power supply eciency performance is Level 5, indicating a high standard in use eciencies and no-load power consumption.The CE Mark is a conformity symbol for European countries. The symbol stands for Conformité Européenne.A Class II or double insulated electrical device. This is one which has been designed in such a way that it does not require a safety connection to electrical earth (ground).The TÜV logo is a certication mark of TÜV Rheinland, a Nationally Recognized Testing Laboratory (NRTL). The “C” on the left of the mark denotes compliance in Canada and the “US” on the right indicating compliance for the US.The symbol for WEEE — Waste Electrical and Electronic Equipment. This symbol indicates that when the end-user wishes to discard  this product, it must be sent to separate collection facilities for recovery and recycling. Note: Please return the equipment to  Philips Lifeline or its representative for proper disposal.The ETL Listed Mark – demonstrates compliance to the requirements of widely accepted product safety standards, as determined through independent testing and periodic follow-up inspections by a Nationally Recognized Testing Laboratory (NRTL). The “C” on the left of the mark denotes compliance in Canada and the “US” on the right indicating compliance for the US.Per EN 60529. The IP27 rating indicates (2)protection against  ngers or other object not greater than 12mm in diameter and (7) Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water up to 1 meter of submersion for up  to 30 minutes.Type BF Applied PartAgency Filing Copy
60 Questions? Call 1-800-635-6156Symbol DescriptionConsult accompanying instructions for use.Symbol for non-ionizing radiation. Indicates that the device(s) include(s) RF transmitters.Indicates the device manufacturer.Indicates the date when the device was manufactured.Use by Date.Indicates the manufacturer’s batch code so that the batch or lot can be identied.Indicates the manufacturer’s catalog number so that the device can be identied.Indicates the manufacturer’s serial number so that a specic device can be identied  To identify the temperature limits, for example on transport packaging to indicate limits within which the package has to be  kept and handled. The temperature values may be shown adjacent to the symbol.To indicate the acceptable upper and lower limits of relative humidity for transport and storage.Refer to instruction manual/bookletAgency Filing Copy
61Questions? Call 1-800-635-6156SECURITY and PRIVACY-related controls that are supported by this product:  • The GoSafe 2 Mobile Pendant (7150MHB), the “Device”, is sealed. The user has no access to any of the internal components of the Device without violating/destroying the device enclosure.• Specialized, precision manufacturing equipment is required to access the physical components that store data within the Device.• Data access interactions with the Device can only be facilitated using proprietary equipment not distributed outside of Philips.  • Wireless/network transmissions made by the Device are made using secure protocols and connections. Agency Filing Copy
62 Questions? Call 1-800-635-6156Agency Filing Copy
63Questions? Call 1-800-635-6156Agency Filing Copy
Philips Lifeline111 Lawrence Street Framingham, MA 01702-8156Tel: 1-800-451-0525www.lifelinesystems.com95 Barber Greene Road, Suite 105Toronto, Ontario, Canada M3C 3E9Tel: 1-800-387-8120© 2017.  All rights reserved.Signal range may vary due to environmental factors.P/N 300000234871 Rev. AAgency Filing Copy