Instruction Insert Smoke Detector P/N 95-0146-00
SMOKE DETECTOR PROGRAMMING INSTRUCTIONS
FOR USE WITH THE MAINSTREET MESSENGER
IMPORTANT
The Smoke Detector when activated, transmits an unique ID Code which must be
“learned” by the Mainstreet Messenger before the detector can be used.
Teach The Mainstreet Messenger the Smoke Detector ID Code
1. Install the two Lithium 2/3AA Batteries into the smoke detector. The
compartment allows installation is only one orientation.
2. Wait 10 seconds after batteries installed, press and hold the smoke detector Test
button until the alarm sounds, this will take about 15 seconds, to verify that the
unit is functioning.
3. Press the Options button on the Mainstreet Messenger (opening tones).
4. Enter the passkey on the Mainstreet Messenger. The default passkey is #1234
(accepted with a single beep).
5. Press *02, the three memory buttons on the right will flash.
6. Press memory button 2 or 3 (memory 1, top button, is usually assigned to the
portable Call Button).
7. Press and hold the smoke detector Test button. The moment the alarm sounds,
release the Test button, the unit’s ID code was transmitted.
8. The Mainstreet Messenger’s top row of three buttons will flash to indicate that it
received an ID Code.
9. The type of alarm needs to be indicated as Fire by pressing the Reminder
Button.
10. Press the Options button to finish.
Installing More Than One Smoke Detector On The Same Mainstreet Messenger
1 of 3
Instruction Insert Smoke Detector P/N 95-0146-00
1. All smoke detectors installed to operate through the same Mainstreet Messenger
must all have the same ID code.
2. Programming the ID Code can only be achieved using a special Elcombe Systems
Programmer.
Location Of Smoke Detectors
IMPORTANT
DO NOT INSTALL the Smoke Detector near large metal objects such as refrigerators
and ovens as they may interfere with the transmitted RF signal.
1. The Smoke Detector is for Indoor Use ONLY.
2. Typically, the Mainstreet Messenger can receive the transmission from the
Smoke Detector up to 50 feet away. Once a location has been chosen, test that
the Mainstreet Messsenger reacts by pressing the Test button on the Smoke
Detector.
OPERATION
Smoke Detector Programmed With 12-Bit ID Code
The Smoke Detector monitors the condition of its batteries and will report a low
battery condition to the Mainstreet Messenger only during a real smoke alarm or
when a smoke detector Test button is initiated. The Mainstreet Messenger
responds to a low battery report from the Smoke Detector in the same manner that
would be reported as with a low battery Call Button.
That is, after the Test Button and the Alert at the Mainstreet Messenger has been
cancelled, the Mainstreet Messenger will flash the Cancel Button and beep
periodically.
Follow the instructions in the Mainstreet Messenger User’s Guide to verify the
battery condition of the smoke detector.
Smoke Detector Programmed With 20-Bit ID Code
The Smoke Detector monitors the condition of its batteries and reports the low
2 of 3
Instruction Insert Smoke Detector P/N 95-0146-00
battery condition in the same manner as detailed for the 12-Bit ID Code.
The added benefit of the 20-Bit ID Code is that the smoke detector can be set to
report its battery condition every 8 hours regardless of good or bad battery.
Similarly, the smoke detector can be set to report every 8 hours only when the
battery is low.
TESTING
The Smoke Detector should be tested weekly by pressing the Test button.
Verify that the alarm sounds and that the Mainstreet Messenger responds
correctly.
FUNCTIONAL DESCRIPTION
Refer to the OEM Instruction Manual which is shipped in the carton with every
unit for detailed functional information.
Telephone 613-591-5678
Fax 613-591-1566
Technical Support 1-800-267-9004
3 of 3

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2000:07:04 08:22:47
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2000:07:04 08:22:49-04:00
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JOK90-2359

Navigation menu