33716 OTUMini APG 088861A E

7/3/07

2:55 PM

Page 1

Blood
Glucose
Monitoring
System

Abbreviated Procedure Guide

IMPORTANT: Read detailed
instructions and other important
information in your owner’s booklet.

Coding the meter
1 Insert a test strip into
the test port as shown. The
three contact bars should be
facing you. The meter will turn
on and display the code from
your last test. If you are using
the meter for the first time,
a constant and a flashing
“——” appears instead of a
code.

2 If the code on the meter does not match the code
on the test strip vial, press ▲ or ▼ to match the code
number on the test strip vial. The display will then advance
to the screen with the flashing blood drop icon .
If the flashing blood drop icon
appears before you are
sure the codes match, remove the test strip and re-start
from step 1.

C

CAUTION: This step is essential to obtain accurate results.

Getting a blood sample from your fingertip
1 Hold the OneTouch®
Lancing Device cap firmly
against the side of your finger.
Press the release button.
Remove the OneTouch® Lancing
Device from your finger.

2 Gently squeeze and/or massage your fingertip
until a round drop of blood of at least one microlitre
( actual size) forms on your fingertip.

Applying the blood sample
1

When the flashing
blood drop icon
appears, touch and hold
the drop of blood to the
narrow channel in the
top edge of the test strip
until the confirmation
window is full.

Top edge

Narrow channel
Apply drop here

If your sample does not fill the
confirmation window on the first try,
do not add more blood to that strip.
Instead, test again with a new strip.

2 After the meter counts
down from 5 to 1, your blood
glucose level appears on the
display along with the unit of
measure, and the date and
time of the test.

WARNING: If mmol/L does not appear with the test result,
call the OneTouch® Customer Care Line at 1 800 663-5521.

33716 OTUMini APG 088861A E

7/3/07

2:56 PM

Page 2

Abbreviated Procedure Guide

Getting a blood sample from your forearm or palm
The OneTouch® UltraMini™ Meter allows you to sample blood from your forearm or palm as well as your fingertip. Before using your forearm or palm
for sampling, please speak to your healthcare professional and refer to the owner’s booklet for complete instructions.

2

1
Replace the blue
cap with the
AST™ Clear Cap.

Choose your sample site.

Forearm
Choose a fleshy area of the forearm away
from bone, visible veins and hair.
Palm
Choose a fleshy area on the palm below the
thumb or pinky finger. Select a spot with no
visible veins and away from deep lines.

Forearm

Palm

Forearm

Palm

3 Firmly press and hold the lancing device against your forearm or palm for a few seconds.
Wait until the skin surface under the AST™ Clear Cap changes color (as blood collects beneath
the skin). This tells you there is enough blood flow for a good sample. Then press the release
button while continuing to apply pressure. Keep holding the lancing device against your skin
until a round drop of blood forms under the cap.
When sampling blood from your forearm or palm, make sure the drop of blood is of at least one
microlitre ( actual size) before you release pressure and remove the lancing device.

Reviewing past results
The meter stores a maximum of 50 blood glucose test results. You can review the results stored in the meter memory, starting with the most recent.
With the meter off, press and
release ▼ to turn it on. Your most
recent test result will appear on
the display.

Press ▼ to move to the previous result stored
in the meter. Then, press ▲ or ▼ to move
forward or backward through all of your
results. When you’re finished, press and
hold ▼ for two seconds until the meter turns off.

Setting the time and date
Before using your meter for the first time, you should check and update
these settings. Start with the meter off, then press and hold ▼ for five
seconds until the start-up test screen
appears. After the test screen, the pre-set
time and date will appear on the display
for five seconds.
Note: If a setting does not need to be updated, simply wait five seconds.
The meter display will automatically advance to the next setting.

3

The year will now flash. Press ▲ or ▼
to change the year. When the correct year is
on the display, wait five seconds.

4

With the month flashing on the
display, press ▲ or ▼ to change the month,
then wait five seconds.

5

1

The hour will now start flashing. Press and release ▲ or ▼ to
change the hour. Note that “AM” or “PM”
changes when you pass 12:00.
When the correct hour is on the display,
wait five seconds.
Check AM/PM. If not correct, continue to press ▲ or ▼ until
the hour and “AM” or “PM” are correct.

2 The minutes will now start flashing.
Press ▲ or ▼ to change the minutes, then
wait five seconds.

The day will now flash. Press ▲ or ▼
to change the day, then wait five seconds.

Your time and date settings will appear on
the display for five seconds. Your settings
will be saved and the meter will then turn off.

Need help?
Call the OneTouch® Customer Care Line
1 800 663-5521
or
Visit us at www.OneTouch.ca
Trademarks owned by Johnson & Johnson and used under license.
©2007 LifeScan Canada Ltd., Burnaby, B.C., V5C 6C6

Rev. 2007/03
AW 088861A



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Extract
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 for Macintosh
Modify Date                     : 2007:07:11 09:55:17-07:00
Creator Tool                    : QuarkXPress: pictwpstops filter 1.0
Create Date                     : 2007:07:03 14:56:46-07:00
Metadata Date                   : 2007:07:11 09:55:17-07:00
Format                          : application/pdf
Creator                         : Eleanor
Title                           : 33716 OTUMini APG 088861A E
Document ID                     : uuid:5a8f5042-29b0-11dc-9fda-0017f202abd8
Instance ID                     : uuid:59f481e8-2f2e-4020-92e2-5fdaad0d24c0
Has XFA                         : No
Page Count                      : 2
Author                          : Eleanor
EXIF Metadata provided by EXIF.tools

Navigation menu