Liftmaster Mh Quick Start Guide 01 34219
2014-07-19
: Liftmaster Liftmaster-Mh-Quick-Start-Guide liftmaster-mh-quick-start-guide liftmaster pdf
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
QuickStart for the Model MJ/MH/MHS/MGJ Door Operator MEDIUM DUTY LOGIC This QuickStart is intended to highlight a typical installation. These instructions are not intended to be comprehensive. Since each application is unique, it is the responsibility of the purchaser, designer, installer and end user to ensure that the total door system is safe for its intended use. Please consult the manual and/or a qualified technician for further information. NOTE: Intended for Professional Installation Only. Visit www.liftmaster.com to locate a professional installing dealer in your area. MANUAL DISCONNECT This operator has provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate instructions below for your model operator. AN ENTRAPMENT PROTECTION DEVICE IS HIGHLY RECOMMENDED Turn off power to the operator BEFORE manually operating your door. INSTALLATION Model MH Determine Mounting Location for Operator Wall Mount Bracket Shelf Mount These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used. Wall Mount: The operator should generally be installed below the door shaft, and as close to the door as possible. 1 Pull the disconnect chain (sash chain) to engage the hoist mechanism. The disconnect Bracket Shelf Mount: The operator may be mounted either above or below the door shaft. chain may be locked in position by slipping the end through the keyhole of the chain keeper mounted on the wall. NOTE: The optimum distance between the door shaft and operator drive shaft is between 12 - 15 inches. 2 Operate the door in the desired direction by pulling on one side or the other of the continuous loop hoist chain. Install the Operator 1 Place door sprocket on the door shaft. Do not insert the key at 3 The disconnect chain must be released from the chain retaining bracket before the door will operate again electrically. this time. 2 Place drive sprocket on the appropriate side of the operator. Do not insert the key or set screw at this time. 3 Wrap chain drive around door sprocket and join roller chain ends together with master link. Model MHS Optimum Distance 12" - 15" Optimum Distance 12" - 15" 1 Refer to Model MH instructions for hoist operation. 4 Raise operator to approximate mounting position and position chain over operator sprocket. 2 Refer to Model MJ instructions for manual operation. 5 Raise or lower operator until the chain is taut (not tight). Make sure the operator output shaft is parallel to door shaft and sprockets are aligned. When in position, secure the operator to wall or mounting bracket. 6 7 Optional Mounting Bracket When operator is disconnected by manual operation chain, hoist and electrical operation will not function. Align sprockets, insert key into keyway, and secure. Models MJ and MGJ Place hand chain around hand chain wheel (if provided). This operator has a floor level disconnect chain to disconnect the door from the door operator. 1 To disengage, pull the chain and secure in the disengaged position by slipping the end Power and Ground Wiring Connections 8 Run the power wires through the power wiring conduit hole in Run control wires through the control wiring conduit hole in the electrical box enclosure. Follow ALL local electrical codes. Adjustments 10 Adjust the limit switches to open and close door properly. Make sure the limit nuts are positioned between the limit switches before proceeding with adjustments. through the keyhole bracket mounted on the wall. Or if emergency egress device is used, pull handle to disengage operator from door. Door Sprocket the electrical box enclosure. Connect the power to the operator. Connect the earth ground to the ground screw in the electrical box enclosure. Follow ALL local electrical codes. 9 This operator includes both a floor level disconnect sash chain to disconnect the door from the door operator and a disconnect sash chain with manual hoist operation that electrically disables the operator controls. Door Shaft Drive Chain Operator Drive Sprocket Be sure door sprocket is properly aligned with operator drive sprocket before securing to the shaft. Hand Chain Wheel Troubleshooting instructions inside cover of operator. again electronically. ELECTRICAL INTERLOCK WITH HOIST FOR MODELS MH AND MHS Chain Keeper Clutch Shaft Hand Chain 11 Remove cotter pin from nut on the clutch shaft. Back off clutch nut until there is very little tension on the clutch spring. Tighten clutch nut gradually until there is just enough tension to permit the operator to move the door smoothly but to allow the clutch to slip if the door is obstructed. Reinstall cotter pin when finished. 2 The door may now be pushed up or pulled down manually. 3 Release the disconnect chain or reset the emergency egress device to operate the door Chain Retaining Bracket (4 feet above floor) MANUAL DISCONNECT FOR MODELS MJ Keyhole Bracket QuickStart for the Model MJ/MH/MHS/MGJ Door Operator MEDIUM DUTY LOGIC This QuickStart is intended to highlight a typical installation. These instructions are not intended to be comprehensive. Since each application is unique, it is the responsibility of the purchaser, designer, installer and end user to ensure that the total door system is safe for its intended use. Please consult the manual and/or a qualified technician for further information. NOTE: Intended for Professional Installation Only. Visit www.liftmaster.com to locate a professional installing dealer in your area. PROGRAMMING Requires LiftMaster Monitored Entrapment Protection (LMEP) device. See installation manual for LiftMaster Monitored Entrapment Protection (LMEP) device selection and installation. AN ENTRAPMENT PROTECTION DEVICE IS HIGHLY RECOMMENDED LIMIT SWITCHES REMOTE CONTROLS 115 V PH. 1 Power Connection Built in 315 MHz radio receiver permits as many as 20 Security✚® remote controls or dip switch remote controls in any combination. 9 L1 L2 Single Button Remote Control and hold the button on the remote and release the LEARN 1 Press 2 Press control until the LED flashes rapidly, then button (LED will light). Retaining Plate POWER WIRING E LOS OP EN C Limit Nuts release to complete programming (LED will go out). R27 Power Wiring ONLY! LEARN TTC STOP CLOSE OPEN D14 LED 1 2 3 4 5 6 To Erase All Remote Controls and hold the LEARN button (over 5 1 Press seconds) until the LED goes out. All programmed remote controls will be erased. 7 R27 LEARN TTC STOP CLOSE OPEN D14 LED LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN 1 POWER WIRING USE COPPER WIRE ONLY AUX AUX ANT 3 4 5 6 7 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN ^^^^ ANT 2 AUX ANT LEARN TTC STOP CLOSE OPEN D14 LED 1 2 3 4 5 6 7 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN SAF Repeat steps 1 and 2 for additional remote controls. ETY 14 AWG Minimum Push 3-Button Remote Control to Operate as a Wireless 3-Button Control Station Follow ALL local electrical codes NOTE: The feature will use 3 of the 20 memory channels in the operator. 1 Direction Limit Nut Will Move During Travel Press and release the LEARN button (LED will light). 2 Press the desired button on the logic board (OPEN, CLOSE or STOP). Release both buttons. Press and hold the desired button of the remote control until LED flashes rapidly, then release. 3 R27 LEARN TTC D7 U4 D6 014A1030 C20 1 U1 C21 CLOSE OPEN R27 LEARN TTC STOP CLOSE OPEN D14 LED R25 C9 STOP D14 LED D4 C32 2 3 4 5 6 7 C31 TP1 D5 J4 1 2 3 4 5 6 7 L5 ^^^^ AUX AUX ANT ANT LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN C18 R27 J2 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN TTC D14 LEARN STOP CLOSE OPEN LED 1 2 3 4 5 6 7 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN K2 LT C29 R24 P1 AUX AUX ANT ANT ^^^^ AUX ANT LEARN TTC STOP CLOSE OPEN D14 LED 1 2 3 4 5 6 7 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN D9 Repeat steps 1 through 3 to program additional buttons. TIMER-TO-CLOSE 1 2 3 4 USE COPPER WIRE ONLY 5 6 Timer-to-Close feature enables the operator to close from the open limit after a preset time, adjustable from 5 to 60 seconds. 7 Timer Defeat To Program OPEN CLOSE STOP INTRLK COM LMEP2 LMEP1 Begin with the door in fully closed position. Press and release the LEARN Press and release the TCC button (LED will light). button. 1 CONTROL WIRING 2 R27 16-22 AWG R27 LEARN TTC STOP LEARN TTC CLOSE OPEN 1 1 2 3 4 5 6 STOP CLOSE OPEN D14 LED D14 LED 2 3 4 5 6 press and release of the STOP button 4 3 Every will add 5 seconds to the Timer-to-Close. Example: 30 second TTC = 6 presses of the STOP button. The TTC can be temporarily disabled by pressing a STOP button. TTC will become enabled after the next open command. Press and release the TTC button to exit programming mode. The LED will flash once per 5 seconds of timer setting. R27 7 LEARN TTC 7 STOP CLOSE OPEN R27 1 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN 2 LEARN TTC D14 LED LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN STOP CLOSE OPEN D14 LED 3 4 5 6 7 1 2 3 4 5 6 7 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN CONTROL WIRING AUX AUX ANT ^^^^ ANT AUX ANT LEARN TTC STOP CLOSE OPEN D14 LED 1 2 3 4 5 6 7 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN The TTC will become active after completion of the next open cycle. NOTE: The LED does not indicate that timer is running. To Verify the Timer-To-Close (TCC) Setting and release the TTC button a and release the TCC and hold the LEARN 1 Press 3 Press 2 Press second time. The LED will flash once button. button (LED will light). Clear the Timer-To-Close (TCC) and hold the and release the LEARN 3 2 Press 1 Press TCC button for 6 seconds. button (LED will light). per 5 seconds of timer setting. Release the TTC button (LED will go out). The TTC will no longer be active. R27 LEARN TTC R27 LEARN TTC STOP CLOSE OPEN STOP CLOSE OPEN R27 R27 LEARN TTC D14 LED D14 LED STOP CLOSE OPEN LEARN TTC STOP CLOSE OPEN D14 LED D14 LED R27 R27 1 1 White/Black 2 3 4 5 6 2 3 4 5 6 7 LEARN TTC STOP 7 LED 1 2 1 3 4 5 6 2 3 4 6 7 1 2 3 4 5 6 7 STOP CLOSE OPEN D14 LED 7 1 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN 2 3 4 5 6 7 ANT ^^^^ AUX AUX ANT ANT ^^^^ AUX ANT LEARN TTC STOP CLOSE OPEN 2 AUX ANT LEARN TTC D14 LED 1 STOP CLOSE OPEN D14 LED 3 4 5 6 7 1 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN © 2009, The Chamberlain Group Inc. All Rights Reserved LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN AUX AUX ANT 01-34219 5 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN White LiftMaster Monitored Entrapment Protection (LMEP) LEARN TTC CLOSE OPEN D14 2 3 4 5 6 7 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23 Modify Date : 2010:12:01 14:10:44-07:00 Create Date : 2009:10:02 15:13:38-07:00 Metadata Date : 2010:12:01 14:10:44-07:00 Format : application/pdf Title : 01-34219 Creator : The Chamberlain Group, Inc. Document ID : uuid:0b6cc023-bf9d-5f46-9ed9-f2ec20a1315c Instance ID : uuid:c8660853-0dfd-8744-bf31-3e33b368b77a Page Count : 2 Page Layout : SinglePage Author : The Chamberlain Group, Inc.EXIF Metadata provided by EXIF.tools