LigoWave FWBD1401 Broadband Digital Transmission System User Manual

LigoWave LLC Broadband Digital Transmission System Users Manual

Users Manual

Download: LigoWave FWBD1401 Broadband Digital Transmission System User Manual
Mirror Download [FCC.gov]LigoWave FWBD1401 Broadband Digital Transmission System User Manual
Document ID1894674
Application IDDPjCVb2kn4zrmLIyG1y1wg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize138.47kB (1730905 bits)
Date Submitted2013-02-06 00:00:00
Date Available2013-02-06 00:00:00
Creation Date2013-02-01 09:22:18
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2013-02-01 09:22:18
Document TitleMicrosoft Word - 1-LigoPTP software manual-待完善排版.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: a

LigoPTP
User’s Guide
Revision 1.4
February 1, 2013
Copyright © 2005-2010 LigoWave www.ligowave.com
FCC Warning
CE Mark Warning
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference in a residential installation. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one of the following measures:
This is a Class A product. In a domestic environment
this product may cause radio interference in which
case the user may be required to take adequate
measures.

Reorient or relocate the receiving antenna.

Increase the separation between the equipment
and receiver.

Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV
technician for help.

This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that may
cause undesired operation.
R&TTE Compliance
Statement
This equipment complies with all the requirements of
the Directive 1999/5/EC of the European Parliament
and the Council of 9 March 1999 on Radio Equipment
and Telecommunication Terminal Equipment and the
Mutual Recognition of their Conformity (R&TTE).
The R&TTE Directive repeals and replaces in the
directive 98/13/EEC (Telecommunications Terminal
Equipment and Satellite Earth Station Equipment) As
of April 8, 2000.
Safety
FCC Caution
This equipment is designed with the utmost care for
the safety of those who install and use it. However,
special attention must be paid to the dangers of electric
shock and static electricity when working with
electrical equipment. All guidelines of this manual and
of the computer manufacturer must therefore be
allowed at all times to ensure the safe use of the
equipment.
To assure continued compliance, any changes or
modifications not expressly approved by the party
responsible for compliance could void the user's
authority to operate this equipment.
EU Countries Intended for Use
IMPORTANT NOTE:
Radiation Exposure Statement
To comply with RF exposure requirements in section
1.1307, a minimum separation distance of 3.9 feet is
required between the antenna and all occupational
persons, and a minimum separation distance of 8.7
feet is required between the antenna and all public
persons.
This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
The ETSI version of this device is intended for home
and office use in Austria, Belgium, Denmark, Finland,
France (with Frequency channel restrictions),
Germany, Greece, Ireland, Italy, Luxembourg, The
Netherlands, Portugal, Spain, Sweden and United
Kingdom. The ETSI version of this device is also
authorized for use in EFTA member states Iceland,
Liechtenstein, Norway and Switzerland.
EU Countries Not Intended for
Use
None.
LigoWave
Page 2
List of additional approval
antenna:
RSS (Category I Equipment):
1:Omni Directional (External ,black)RPSMA-J
connector 3dBi ,impedance is50ohm
This device complies with Industry Canada licenceexempt RSS standard(s). Operation is subject to the
following two conditions:
2:MCX 5GHz 23 dBi directional antenna, impedance
is50ohm
(1) This device may not cause interference, and
3:ARC EXSITETM Parabolic Dual-Pol Dish Antenna
4.94-5.875 GHz 30dBi, impedance is50ohm
(2) This device must accept any interference,
including interference that may cause undesired
operation of the device.
Antenna Installation Warning:
1, It is installer’s responsibility to ensure that when
using the authorized antennas in the United States and
Canada;
2, only those antennas certified with the product are
used;
3, the use of any antenna other than those certified
with the product is expressly forbidden in accordance
to FCC rules CFR 47 part 15.204, RSS-GEN7.1.2;
4, The Installer should configure the output power
level of antenna, according to country regulations and
per antenna type;
5, Professional installation is required of equipment
with connectors to ensure compliance with health and
safety issues.
Under Industry Canada regulations, this radio
transmitter may only operate using an antenna of a
type and maximum (or lesser) gain approved for the
transmitter by Industry Canada. To reduce potential
radio interference to other users, the antenna type and
its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than
that necessary for successful communication.
This radio transmitter (identify the device by
certification number, or model number if Category II)
has been approved by Industry Canada to operate with
the antenna types listed below with the maximum
permissible gain and required antenna impedance for
each antenna type indicated. Antenna types not
included in this list, having a gain greater than the
maximum gain indicated for that type, are strictly
prohibited for use with this device.
For Professional installation NOTE:
The 5GHz 23dBi directional antenna and ARC
EXSITETM Parabolic Dual-Pol Dish Antenna 4.945.875 GHz 30dBi are ONLY intended for fixed (nonmobile), point-to-point applications , the conducted
output power limit can without any corresponding
reduction in transmitter. Any other use is prohibited.
End Product Labeling
Canada Country Intended Use
The devices have an EIPR maximum restricted by
configuration soft ware. When the EIPR exceeds
36dBm(4W), the devices can only be used in the
Point-to-Point systems or in a remote station condition
in Point-to-Multipoint systems.
This final and product must be labeled in a visible area
with the following:
Contains FCC ID:V2V-FWBD1401
Manual Information to the End
User
The OEM integrator has to be aware not to provide
information to the end user regarding how to install or
remove this RF module in the user’s manual of the end
product which integrates this module. The end user
manual shall include all required regulatory
information/Warning as show in this manual.
LigoWave
Page 3
Contents
Warning ............................................................................................................................................... 2
FCC Caution ............................................................................................................................................... 2
IMPORTANT NOTE .................................................................................................................................... 2
CE Mark Warning ................................................................................................................................ 2
R&TTE Compliance Statement ........................................................................................................... 2
Safety .......................................................................................................................................................... 2
EU Countries Intended for Use ................................................................................................................... 2
EU Countries Not Intended for Use............................................................................................................. 2
CONTENTS ............................................................................................................................................ 4
ABOUT THIS GUIDE.............................................................................................................................. 6
Purpose ............................................................................................................................................... 6
Definitions, Acronyms and Abbreviations............................................................................................ 6
INTRODUCTION..................................................................................................................................... 7
Application Examples .......................................................................................................................... 8
Building to Building Connectivity......................................................................................................8
Backhaul ..........................................................................................................................................8
PTP Features ...................................................................................................................................... 9
Technical Features...................................................................................................................................... 9
Management ............................................................................................................................................... 9
Reliability..................................................................................................................................................... 9
ACCESSING THE PTP UNIT’S WEB MANAGEMENT....................................................................... 10
Default Settings .............................................................................................................................11
Quick Setup Guide ............................................................................................................................ 11
Verify PTP Link Connection .............................................................................................................. 16
Align Antenna .................................................................................................................................... 19
WEB MANAGEMENT........................................................................................................................... 20
General Operation............................................................................................................................. 20
Instant Changes.............................................................................................................................20
System Warnings and Errors.........................................................................................................20
Signal Indicator ..............................................................................................................................21
Status ................................................................................................................................................ 23
System ...........................................................................................................................................23
Network..........................................................................................................................................24
Wireless .........................................................................................................................................24
Statistics.........................................................................................................................................25
Graphs ...........................................................................................................................................26
Configuration ..................................................................................................................................... 30
Network..........................................................................................................................................30
Radio..............................................................................................................................................31
Instant Changes ........................................................................................................................................ 31
System ...........................................................................................................................................33
Link Settings.............................................................................................................................................. 33
System Date.............................................................................................................................................. 33
Administrative Account.............................................................................................................................. 35
System Log ............................................................................................................................................... 35
Services .........................................................................................................................................36
SNMP Configuration ................................................................................................................................. 36
WNMS Configuration ................................................................................................................................ 37
System Alerts ............................................................................................................................................ 37
Maintenance.............................................................................................................................................. 39
LigoWave
Page 4
System Functions...................................................................................................................................... 39
OLED Control............................................................................................................................................ 40
Firmware Upgrade .................................................................................................................................... 41
Tools.................................................................................................................................................. 42
Antenna Alignment ........................................................................................................................42
Site Survey.....................................................................................................................................42
Link Test ........................................................................................................................................43
Logout................................................................................................................................................ 45
APPENDIX............................................................................................................................................ 46
A) Run PTP Link in Small Distance................................................................................................... 46
B) Resetting Unit to Factory Defaults................................................................................................ 49
LigoWave
Page 5
About This Guide
Purpose
This document provides information and procedures on installation, setup, configuration, and
management of the PTP unit.
Definitions, Acronyms and Abbreviations
The following typographic conventions and symbols are used throughout this document:
Additional information that may be helpful but which is not required.
Important information that should be observed.
bold
Menu commands, buttons, input fields, links, and configuration keys are displayed in bold
italic
References to sections inside the document are displayed in italic.
code
File names, directory names, form names, system-generated output, and user typed
entries are displayed in constant-width type
LigoWave
Page 6
Introduction
The PTP link consists of two units, one on each end: Master and Slave. Master unit operates as an
access point; therefore the Slave connects to the Master and operates as a client.
Figure 1 – Point-to-Point Link Elements
From the point of view of the administrator the Local unit is the one with the direct connection to the
Web management interface and the Remote unit is the one which is connected to the Local unit in
PTP link. The concept of the Local unit and the Remote unit is not related to the operating mode
(Master or Slave). This terminology will be used throughout the manual, particularly in the description
of statistics.
LigoWave
Page 7
Application Examples
Building to Building Connectivity
Use the PTP for building to building connectivity in the private networks such as campus building
connections, corporate building connections, universities and schools that wish to own and manage
their own networks and eliminate the costly recurring charges from service providers. The same
connectivity is perfect to build backup/failover connections.
Figure 2 – Building to Building Connectivity
Backhaul
The PTP offers a cost effective solution made for WISPs, Cellular Carrier, Telco, ISPs, enabling
operators to quickly and efficiently expand their networks.
LigoWave
Page 8
Figure 3 – PTP Backhaul
PTP Features
Technical Features




High throughput;
Flexible Channel Sizes (20MHz and 40MHz);
Flexible center frequency selection (allows selecting center frequency in 5MHz step);
Robust MAC layer:
 Selective repeat ARQ with block ACK
 Only lost packets are retransmitted
 Highly efficient in noisy environments
 Low throughput loss over long distance
 Forward error correction (recovers packets with errors without retransmit)
 Dynamic TDD (see the Figure 4 – Point to Point Protocol W-jet MIMO)
 Allocates bandwidth in the direction needed in real-time
 Highly reliable and efficient over long distances
 Packet aggregation (smaller frames are collected into larger frames to increase efficiency and
throughput)
 High PPS (Packet Per Seconds) performance
 High TX power and RX Sensitivity
 PoE built-in for single cable installation
Figure 4 – Point to Point Protocol W-jet MIMO
Management






Flex based fast GUI
Command line management via SSH
WNMS server support for configuration
SNMP V1/2/3 with traps supporting MIBs: 802.1, 802.1x, MIBII
Syslog support
Reset over Ethernet on boot
Reliability





Lightening protection
Solid metal construction
IP67 rated
Proven software platform
Extensive production testing
LigoWave
Page 9
Accessing the PTP Unit’s Web Management
The default IP address of the PTP unit is 192.168.2.66 with a subnet mask of 255.255.255.0.
Step 1.
Configure your PC with a static IP address on the 192.168.2.0 subnet with mask
255.255.255.0.
Step 2.
Connect the PTP unit in to the same physical network as your PC.
Step 3.
Open the Web browser and browser, type the default IP address of the PTP unit
https://192.168.2.66/ to load the login page.
Step 4.
Enter the default administrator login settings to access the Web management page.
The default administrator login settings for PTP unit are:
Login:
admin
Password: admin01
Step 5.
LigoWave
After successful administrator log on you will see the main page of the PTP unit Web
management interface. The PTP unit now is ready for configuration. For further
instructions on configuration refer to the respective chapter Web Management.
Page 10
Default Settings
The default settings of the PTP unit configuration parameters are listed in the table below:
Parameter
Default value
IP address
192.168.2.66
Netmask
255.255.255.0
Login
admin
Password
admin01
Link ID
Link name
Encryption
None
Ethernet configuration
auto
SNMP R/O community
public
SNMP R/O user
public
SNMP R/O password
password
Quick Setup Guide
Step 1.
Login in to the PTP unit web management. To access the PTP unit Web management
interface, configure your PC with a static IP address on the 192.168.2.0 subnet with mask
255.255.255.0. Connect the PTP unit in to the same physical network as your PC. Open
the Web browser and type the default IP address of the PTP unit
https://192.168.2.66/ and the login page will be loaded. Enter default administrator
login settings:
Figure 5 – Login Page
The default administrator login settings for PTP unit are:
Login:
admin
Password: admin01
After successful administrator login you will see the main page of the PTP unit Web
management interface. The PTP unit now is ready for configuration.
Step 2.
Specify the operation mode: Master or Slave. The difference in configuration of Master
and Slave is that the frequency does not need to be specified for the Slave. The Slave
scans the air and chooses the frequency automatically after finding the Master.
LigoWave
Page 11
Figure 6 – Specify Unit's Operating Mode
Step 3.
Specify a Link ID. Link ID must be identical for each unit of the same link. For instructions
on changing this setting refer to the Radio section in the Web management chapter.
Figure 7 – Specify PTP Link ID
Step 4.
Choose the Country in which the PTP link will operate. PTP unit will automatically adjust
Radio settings to meet country/region specific regulations.
LigoWave
Page 12
Figure 8 – Specify Country
Step 5.
Set Frequency at which PTP link will operate on Master unit. Change Frequency
applies only for Master units. The Slave unit will choose the frequency automatically after
the Master unit will be found. For instructions on changing this setting refer to the Radio
section in the Web management chapter.
Figure 9 – Specify Frequency
Step 6.
Set Channel width at which PTP link will operate. For instructions on changing this
setting refer to the 错误!未找到引用源。 section in the Web management chapter.
LigoWave
Page 13
Figure 10 – Specify Channel Width
Step 7.
Set link encryption for secure data transfer between PTP units. The security settings
(encryption and passphrase) must be the same on each side of the link otherwise the link
will not establish. For instructions on changing this setting refer to the Radio section in the
Web management chapter.
Figure 11 – Set the Encryption
Step 8.
Reduce Transmit Power before testing the units placed on a table. PTP units placed in
short distance with high transmit power may not work or even damage the peer's radio’s
receiver.
LigoWave
Page 14
Step 9.
Change web management login password. This is strongly recommended for security
reasons. For instructions on changing the administrator’s password refer to the
corresponding section Administrative Account.
Figure 12 – Change Administrator's Password
Step 10.
Save configuration and Reboot the device.
Figure 13 – Save Configuration
Step 11.
LigoWave
Setup the second unit of the PTP link in the same way and check if configured units
established a Link.
Page 15
Verify PTP Link Connection
After the both units of the PTP Link are configured, verify the PTP link quality:
Step 1.
Connect to the unit’s web management interface.
Step 2.
Check the Signal Indicator bar located at the bottom of the web management interface:
Figure 14 – Signal Indicator Bar
Step 3.
LigoWave
Run the iperf tool (or use the Link Test) on server and client sides to verify the point-topoint connection:
Page 16
Figure 15 – iperf Results (TCP)
LigoWave
Page 17
Figure 16 – iperf Results (UDP)
Step 4.
LigoWave
If test results are meeting the requirement and are no configuration will be done
Transmit power should be increased, before mounting PTP units outside. Note that if
the distance between the units is short, do not set Transmit Power to the maximum
value. Observe the Signal Indicator bar – if it is red, decrease the Transmit Power.
Page 18
Align Antenna
Avoid standing directly in front of an operating antenna while aligning.
The PTP units are equipped with two signal strength feedback systems: antenna alignment tool on
the Web management interface and antenna alignment tool on the OLED screen.
Follow the steps to establish a radio link between the two PTP units and align the units for the best
signal strength.
Step 1.
Ensure that power is supplied to both PTP link units.
Step 2.
Ensure normal operation of the unit: check the OLED screen or Status page on the
Web management interface.
Step 3.
Run the Antenna Alignment tool on the selected interface (OLED or Web
management) and move the antenna in the horizontal and vertical planes until the
maximum RSSI visible on the Antenna Alignment graph is achieved.
Figure 17 – Antenna Alignment Tool on Web Management Interface
Figure 18 – Antenna Alignment Tool on OLED
For detailed instructions on Antenna Alignment tool, refer to the respective sections:
 Web management – Antenna Alignment
 OLED screen – 错误!未找到引用源。
Step 5.
LigoWave
After the maximal RSSI is reached, tighten down the unit in the optimum position.
Page 19
Web Management
PTP products are designed to provide superior performance at long range distances. With a
proprietary wireless driver that was written for the sole purpose of optimizing wireless point to point
links, one can achieve much higher throughput, especially at longer links, than standards based
products.
General Operation
This section provides information about concepts used in PTP unit’s Web management interface.
Instant Changes
Some of the PTP radio parameters do not require to reboot the device. These parameters are named
as instant changes.
Instant changes are useful for best performance parameters tuning. These parameters will take effect
as soon as the Apply button is clicked. When best configuration is founded press Save button and
reboot the device to make changes permanent. Otherwise all instant parameter changes will be lost
during PTP unit reboot.
Instant changes are on the Radio section.
System Warnings and Errors
There are 3 types of system messages that must be noted: notifications, warnings and error
messages. These messages appear at the bottom of the page and can be closed by clicking the
sign .
For example notification messages are displayed in brown color and contain information about
configuration changes:
Figure 19 – Notification Message (1)
This message has an implemented Reboot button. Simply click this button and the PTP unit will be
rebooted at once – there is no need to navigate into the Maintenance page for additional action to
reboot the unit.
Notification messages also are on Wireless page Instant changes. This message informs you about
instant changes that were made:
Figure 20 – Notification Message (2)
LigoWave
Page 20
Warning messages are displayed in red and contain PTP unit’s system cautions:
Figure 21 – Warning Message
The PTP unit contains built in validation for configuration settings in the web management interface. If
a user sets an incorrect value in the entry field, its frame turns red, and if the user tries to save such
incorrect configuration, an error message appears at the end of the page:
Figure 22 – Error Message
Signal Indicator
The PTP web management interface has a PTP link signal indicator. This indicator displays real-time
signal level in dBm of the Local and Remote units.
Figure 23 – PTP Signal Indicator
LigoWave
Page 21
The color of the Signal indicator will change according to the signal level quality of the unit. The green
color means excellent link quality while the red color of the indicator means that link quality is poor.
The red circle beside full filled red indicator switches on immediately when the signal level becomes
too high and overload is detected.
Figure 24 – PTP Signal Indicator (too Strong Signal)
This may happen on an incorrect link layout, for example, in the case when the TX power parameter
in the PTP units is set to maximum but physically the units are too close to each other (e.g. testing
units are placed on a table).
The screenshot below displays Signal indicator if there is no PTP link established between PTP units:
Figure 25 – PTP Signal Indicator (no Link Established)
LigoWave
Page 22
Status
Use the Status menu to check the current status of the PTP unit and established link (this is the
default page when accessing the device’s web management interface). The Information page displays
generic information and status of the PTP unit. The page is divided into three main categories:
System, Network and Wireless. The System section displays the identification information of the PTP
unit. The Wireless section presents main wireless settings. The Ethernet section describes the PTP
unit’s network identity and connectivity.
The information in the page can be updated using Refresh button.
Figure 26 – Status Page
System
System section displays general information of the PTP unit.
LigoWave
Page 23
Product name – displays the product name.
Link name – displays the link name which is used to identify the PTP unit on the network.
Link location – displays the link location, which is used to identify the PTP unit on the network.
Latitude – displays the latitude coordinates of the device.
Longitude – displays the longitude coordinates of the device.
Firmware version – displays the device hardware and software version.
Uptime – displays the time, expressed in days, hours and minutes since the system was last
rebooted.
Average load – displays the average load of the device processor in the period of the last 1minute, 5
minutes and 15 minutes (a larger value means a larger average load on the processor).
<1.0 – System is idle
=1.0 – Normal load
>1.0 – Processor is busy.
Total memory, kB – displays total system memory.
Free memory, kB – displays free system memory.
System time – displays current system time.
Network
Ethernet link status – displays the status of the Ethernet link. A State UP indicates that the Ethernet
link is established. A state DOWN indicates that the Ethernet link is not established.
Ethernet speed/duplex – displays the negotiated speed and duplex of the Ethernet interface
specified in Mbps. The N/A will be displayed if the Ethernet status is down. Full duplex means that
data can be transmitted in both directions on a signal carrier at the same time. Half duplex means that
data can be transmitted in both directions on a signal carrier, but not at the same time. Auto means
that the system will detect link speed and duplex mode automatically.
MAC address – displays MAC address of the device.
Local IP – displays IP address of the local unit.
Remote IP – displays IP address of the remote unit. The N/A will be displayed if there is no PTP link
established.
Wireless
Wireless link status – displays the status of the Wireless link. A State UP indicates that the Wireless
link between local and remote units is established. A state DOWN indicates that the Wireless link
between local and remote units is not established.
Operating mode – displays the operating mode of the device. The operating mode can be Master or
Slave.
Link ID – displays PTP link ID, specified by the user.
Encryption – displays encryption method: none or AES.
Peer MAC – displays MAC address of the remote unit.
Frequency, MHz – displays frequency in MHz at which the PTP link communicates.
Channel width, MHz – displays the channel width (5/10/20/40) at which the PTP link communicates.
Data rate, Mbps – displays the data rate at which the PTP link communicates.
LigoWave
Page 24
Transmit power, dBm – displays TX power value of the local PTP unit.
Remote transmit power, dBm – displays TX power value of the remote PTP unit.
Statistics
The statistics page displays detailed statistics of the PTP link performance. The Statistics page is
divided into the two sections: Networks statistics and W-Jet statistics.
Network statistics contains detailed statistics of Ethernet and Wireless interfaces:
Figure 27 – Statistics Page
RX bytes - displays the total number of received bytes by the Ethernet or Wireless interface of the
PTP link.
RX packets - displays the total number of received packets by the Ethernet or Wireless interface of
the PTP link.
RX errors - displays the total number of received corrupted packets by the Ethernet or Wireless
interface of the PTP link.
RX drops - displays the total number of dropped packets by the Ethernet or Wireless interface of the
PTP link.
TX bytes - displays the total number of sent bytes by the Ethernet or Wireless interface of the PTP
link.
TX packets - displays the total number of sent packets by the Ethernet or Wireless interface of the
PTP link.
TX errors - displays the total number of sent corrupted packets by the Ethernet or Wireless interface
of the PTP link.
TX drops - displays the total number of dropped packets by the Ethernet or Wireless interface of the
PTP link.
W-Jet statistics displays detailed statistics of PTP link communication protocol.
Figure 28 – W-Jet Statistics
Local – statistics of the Local unit.
LigoWave
Page 25
Remote – statistics of the Remote unit.
Rx bytes – number of transmitted bytes. The number in brackets (+xx) displays the data change
since the last page refresh.
Tx bytes – number of the received bytes. The number in brackets (+xx) displays the data change
since the last page refresh.
Rx packets – number of received data packets The number in brackets (+xx) displays the data
change since the last page refresh.
Tx packets – number of transmitted data packets. The number in brackets (+xx) displays the data
change since the last page refresh.
Tx packets fail – number of failed to transmit packets. The number in brackets (+xx) displays the
data change since the last page refresh.
Tx packets retry – total number of attempts to retransmit data packets. The number in brackets (+xx)
displays the data change since the last page refresh.
RX duplicated packets – the number of received duplicated packets. The number in brackets (+xx)
displays the data change since the last page refresh.
CRC errors – the total number of CRC errors. The number in brackets (+xx) displays the data change
since the last page refresh.
Graphs
The Graphs page contains device statistics in graphic diagrams and is used for device monitoring.
Select the required statistics (RSSI, Traffic, RX/TX errors, Memory, CPU load or Frequency change)
and the corresponding graphic diagrams will be displayed. The statistics in diagrams are displayed on
hourly, daily, weekly, monthly or yearly basis; hourly is chosen by default. The option Display current
time set on the system gives possibility to convert the time stamps on the diagrams in current date,
set on the administrator’s PC.
To update statistics data click Refresh button.
Point the mouse cursor on the diagram line and you will get the numeric expression of the
particular statistic.
RSSI diagram displays RSSI change of the Local and Remote PTP units at the chosen period:
LigoWave
Page 26
Figure 29 – RSSI Graph
Traffic diagram displays Incoming and Outcoming traffic statistical data:
Figure 30 – Traffic Statistics Graph
RX/TX errors diagram displays statistical data of RX drop of the Local and Remote units, TX try of the
Local and Remote units:
LigoWave
Page 27
Figure 31 – RX/TX Errors Statistics Graph
Memory diagram displays memory usage data:
Figure 32 – Memory Status Graph
CPU load diagram displays device CPU load in appropriate time basis:
Figure 33 – CPU Load Graph
LigoWave
Page 28
Frequency diagram displays device operating frequency in GHz:
Figure 34 – Frequency Graph at which PTP Link is Operating
LigoWave
Page 29
Configuration
The Configuration page is subdivided into following pages:

Network – to set main network configuration for PTP device.

Radio – to setup radio settings of the PTP link.

System – to setup system date, administrator's access settings, configure system log feature.

Services – to setup SNMP, RCMS settings and configure device alerts.

Maintenance – for device firmware update, reboot, reset device to factory defaults,
troubleshooting file download and to view system log messages.
Network
The network configuration as described below is required for PTP management purposes. Use the
Network menu to setup the network settings of the PTP unit:
Figure 35 – Network Settings
Method – specify IP configuration mode:

Static IP – choose to specify static IP of the device.

Dynamic IP – choose to use dynamic IP given by the DHCP server (running DHCP server is
required).
IP address – specify the device IP address [digit and dots]. When shipped from the factory or reset to
factory settings, device defaults to a static IP address of 192.168.2.66.
Subnet mask – specify the device subnet mask [digit and dots]. When shipped from the factory or
reset to factory settings, the device defaults to a subnet mask of 255.255.255.0.
Default gateway – specify the IP address of the device gateway [digit and dots]. When shipped from
the factory or reset to factory settings, the device defaults to a gateway IP address of 192.168.2.1.
DNS server 1 – specify the IP address of the primary DNS server [digit and dots]. The DNS (Domain
Name Service) service translates Internet host names into their IP addresses.
DNS server 2 – specify the IP address of the secondary DNS server.
Ethernet configuration - configures the Ethernet link speed and the duplex mode of the Ethernet
port. Choose "auto" for automatic detection of link speed and duplex mode.
Management VLAN ID – specify the management VLAN ID [2-4094].If a management VLAN is
enabled, all traffic received by the device must by tagged with the management VLAN ID to access
the network. All non-tagged traffic will be dropped, thus reducing the risk of unauthorized access.
LigoWave
Page 30
Restrict management to – select interfaces on which management access will be restricted.
Radio
Use the Configuration | Radio menu to set up radio settings for the PTP link:
Figure 36 – Radio Settings
Operating mode – specify the operating mode of the local device to create PTP link [Master/Slave].
The device mode depends on the network topology.


Master – in this mode local device is the controlling PTP link unit.
Slave – in this mode local device connects to the Master unit.
Instant Changes
Applying parameters in the Instant changes section does not require device reboot, therefore making
easy parameters adjustment for best performance.
Link ID – specify known network name of the remote device to establish a PTP link.
Both sides (Master and Slave units) of the link must have the same Link ID name.
Country – from drop-down list choose country in which the devices will operate. According to the
chosen country the regulatory domain settings may differ. You are not allowed to select radio
channels and RF output power values other the permitted values for your country and regulatory
domain.
Frequency – specify frequency at which the PTP link will be operating. If the device is operating in
Slave mode, it will not have the possibility to choose a frequency. The Slave scans the air and
connects to the Master automatically.
LigoWave
Page 31
The available Frequencies list varies depending on the selected Country and Channel
width.
Channel width – choose the channel width in MHz [20/40].
Both sides (Master and Slave) of a link must have the same Link ID, Channel width and
Encryption specified.
Encryption – select the security level for the PTP link:


None – means no security on link.
AES – means encryption with passphrase.
Passphrase – specify passphrase of the AES security [8-63 characters]. This parameter appears and
is mandatory when AES security is chosen.
Transmit power – set the radio transmit power at which the device will transmit data. The larger the
distance, the higher transmit power is required. To set transmit power level use the slider or enter the
value manually. The transmit power level that is actually used is limited to the maximum value allowed
by your country's regulatory agency.
Multipath protection – if checked the signal will became more robust to signal interference caused
by signal echos or reflections. However as the drawback the enabled multipath protection will lead to
reduced link capacity.
Mode – choose the PTP antenna operating mode:
SISO – single input single output. The device will use only one antenna for data transfer. The
antenna will be chosen automatically.
MIMO – multiple input multiple output. The device will use two antennas for data transfer (two
simultaneous streams). In this mode the *link capacity doubles *if compared to SISO mode.
Data rate – select the device data transmission rates in Mbps from the drop-down list.
ACK Timeout – specify the Acknowledgement timeout either in distance, or in time expression:
Distance – specify the distance between PTP units, and ACK timeout will be calculated
automatically according the indicated distance in kilometers or myles.
Time – specify the ACK timeout in time expression.
LigoWave
Page 32
System
The System page is subdivided into 4 sections:




Link settings – to specify PTP link settings.
System date – to setup system date and time of the PTP unit.
Administrative account – to change administrator's password.
System log – to configure logging of the system messages.
Link Settings
Figure 37 – Link Settings
Link name – specify name of the PTP link that is used to identify the unit on the network [maximum
255 ASCII characters].
Link location – describe the location of the PTP unit [maximum 255 ASCII characters].
Longitude – specify the longitude coordinates of the PTP unit [specific decimal format, e.q.
54.869446].
Latitude – specify the latitude coordinates of the PTP unit [specific decimal format, e.q. 23.891058].
Both coordinates helps indicate accurate location of the PTP unit's.
System Date
Use this section to manage the system time and date on the device automatically, using the Network
Time Protocol (NTP), or manually, by setting the time and date on the PTP unit.
The NTP (Network Time Protocol) client synchronizes the clock of the device with the defined time
server. Choose NTP from the configuration menu, select your location timezone and enter NTP server
in order to use the NTP service:
LigoWave
Page 33
Figure 38 – System Date: NTP Configuration
Configuration – choose the system clock configuration mode [NTP/Manual].
Timezone – select the timezone. Time zone should be specified as a difference between local time
and GMT time.
Save last known time – select to recall the timestamp that was saved on last reboot. When NTP is
enabled, this option will set system clock to last reboot time if no NTP servers are available.
NTP server – specify the trusted NTP server IP or hostname for synchronizing time with [IP address].
To adjust the clock settings manually, choose the configuration mode as Manual and specify the
following settings:
Figure 39 – System date: Manual Clock Configuration
Configuration – choose the system clock configuration mode [NTP/Manual].
Timezone – select the timezone. Time zone should be specified as a difference between local time
and GMT time.
Save last known time – select to recall the timestamp that was saved on last reboot.
Date – specify the new date value in format MM/DD/YYYY.
Time – specify the time in format hh:mm.
If the device hardware has no internal clock, the configured manual time will be reset to the
specified date and time after each device reboot.
LigoWave
Page 34
Administrative Account
We recommend changing the default administrator password as soon as possible.
The Administrative Account menu is for changing the administrator’s password.
Figure 40 – Changing the Administrator's Password
Old password – enter the old administrator password.
New password – enter the new administrator password for user authentication.
Verify password – re-enter the new password to verify its accuracy.
The only way to gain access to the web management if you forget the administrator
password is to reset the device to factory default settings.
Default administrator login settings are:
User Name: admin
Password: admin01
System Log
Use the Configuration | System menu to configure device to save log messages to the local or remote
server using standard syslog facility:
Figure 41 – System Log Configuration
LigoWave
Page 35
Message level – specify system's message tracing level. The level determines the importance of the
message and the volume of messages generated by the PTP unitThe levels are in increased
importance order [emergency, alert, critical, error, warning, notice, information, debug]. Default: info.
The PTP unit can be configured to send system log messages to a remote server:
Syslog forward – select to enable remote system logging.
Forward server – specify the remote host IP address or hostname where syslog messages will be
sent.
Forward port – specify the port to which syslog messages will be forwarded [0-65535]. Default: 514.
Forward message level – specify the message level that will be send to the remote syslog server.
The level determines the importance of the message and the volume of messages generated by the
PTP unit. The levels are in order of increasing importance
[emergency/alert/critical/error/warning/notice/information/debug]. Default: information.
Forward backup – select to enable remote syslog logging backup.
Backup server – specify the backup host IP address or hostname where syslog messages will be
send to.
Backup port – specify the port to which syslog messages will be forwarded [0-65535]. Default: 514.
To view logged system messages locally, navigate to the menu Maintenance
Services
The Services page is divided into 3 sections:



SNMP configuration – To enable SNMP and setup SNMP on the PTP unit.
RCMS configuration – to enable and setup RCMS agent on the PTP unit.
Alerts – to enable and setup system alerts.
SNMP Configuration
SNMP is the standard protocol that is widely used for remote network management over the Internet.
With the SNMP service enabled, the PTP unit can act as SNMP agent.
To communicate with SNMP manager you must configure SNMP communities and
identifiers on both ends (manager and agent).
Figure 42 – SNMP Settings Configuration
Enable SNMP – specify the SNMP service status.
LigoWave
Page 36
Name – displays an administratively assigned name.
System location – displays the physical location of the PTP unit [string].
R/O community – specify the read-only community name for SNMP version 1 and version 2c [string].
The read-only community allows a manager to read values, but denies any attempt to change values.
R/O user – specify the user name for read-only SNMPv3 access [string]. The read-only community
allows a manager to read values, but denies any attempt to change values.
R/O user password– specify the password for read-only SNMPv3 access [string].
WNMS Configuration
Wireless Network Management System (WNMS) is a centralized monitoring and management system
for wireless network equipment. The communication between managed devices and the WNMS
server is always initiated by an WNMS agent service running on every device.
Figure 43 – WNMS Agent Configuration
Enable WNMS – select to enable WNMS agent settings.
Server/Collector URL – specify the URL of the WNMS server that heartbeat notifications will be sent
to.
System Alerts
The PTP unit is able to send external alerts when there are system errors. The alerts can be sent via
SNMP Traps or/and SMTP notifications.
LigoWave
Page 37
Figure 44 – System Alerts Configuration
Enable alerts – select to enable alert notifications on the system.
System check interval, s – specify interval in seconds at which the device will send notifications of
unexpected system behavior.
System alerts:








Wireless link status change – system will send notification on Wireless link status change.
Ethernet link status change – system will send notification on Ethernet link status change.
RSSI level lower than – system will send notification when RSSI reach value lower than
specified. Default: 25.
Noise level greater than – system will send notification when signal noise will reach value
greater than specified. Default: -60 dBm.
RX drop greater than – system will send notification when the specified percent of RX dropped
packets becomes higher than specified value.
TX retry greater than – system will send notification when the specified percent of TX retries
becomes higher than specified value.
Device reboot – system will send notification about unexpected or administrator initiated device
reboot.
DFS channel change – system will send notification on DFS channel change.
SNMP Traps Settings
Manager address – specify the IP address or hostname of Trap receiver.
Manager port – specify the port number of the Trap receiver. Default port number is 162.
Trap community – specify the SNMP community string. This community string acts as password
between SNMP manager and PTP unit. by default Trap community string is "public".
LigoWave
Page 38
Use inform – select to wait for an acknowledgment from SNMP manager that trap was received.
Retry count – specifies maximum number of times to resend an inform request [1-10]. Default: 5.
Retry timeout – specifies number in seconds to wait for an acknowledgment before resending
request [1-10]. Default: 1.
SMTP Settings
Server address – specify the IP address or hostname of the networked SMTP server.
Server port – specify the SMTP Port Number is the port number used by the networked SMTP server.
By default the port number is 25.
Source e-mail – specify the e-mail address that will be used by the PTP unit.
Destination e-mail – specify the e-mail address where the PTP unit will send the alert messages.
E-mail notification interval – specify interval in seconds at which the e-mail notification will be sent
from the PTP unit [0-86400]. If 0 specified, then device will send an e-mail notification immediately
after unexpected system behavior.
Maintenance
Use Maintenance menu for device firmware update, reboot, reset device to factory defaults,
troubleshooting file download, view system log messages and control OLED.
System Functions
Figure 45 – Main System Functions
Reboot device – reboot device with the last saved configuration.
Reset device to factory defaults – click to restore unit's factory configuration values.
Resetting the device is an irreversible process. Current configuration and the administrator
password will be set back to the factory default.
Download troubleshooting file – click to download the troubleshooting file. The troubleshooting file
contains valuable information about device configuration, routes, log files, command outputs, etc.
When using the troubleshooting file, the device quickly gathers troubleshooting information
automatically, rather than requiring you to gather each piece of information manually.. This is helpful
for submitting problems to the support team.
Backup configuration file - click to save the current configuration file. The saved configuration file is
useful to restore a configuration in case of a device misconfiguration or to upload a standard
configuration to multiple devices without the need to manually configure each device through the web
interface..
LigoWave
Page 39
Restore configuration from file - click to upload an existing configuration file to the device.
View system log - click to view current trace messages. The Syslog viewer utility provides debug
information about the system services and protocols. If the device's malfunction occurs recorded
messages can help operators to locate misconfiguration and system errors. The syslog capability can
help operators to locate misconfiguration and system errors.
Figure 46 – System Log Viewer
Filter – filter content of the system messages by entering required words or symbols.
To change level of the system messages displayed in the Syslog viewer use menu System
Log.
OLED Control
Use this section under Maintenance tab to control status or assign a PIN code for the PTP unit’s
OLED:
LigoWave
Page 40
Figure 47 – OLED Control
Enable OLED – select to enable or disable OLED on the PTP unit.
PIN required – select to enable or disable OLED protection with PIN.
PIN – enter 4 digits for OLED protection.
Firmware Upgrade
To update your device firmware use the Firmware upgrade section under the Maintenance menu,
select the firmware file and click the Upload button:
Figure 48 – Firmware Upload on the System
Current version – displays version of the current firmware.
Upload firmware – click the button to select the new firmware image for uploading it to the device..
The device system firmware upgrade is compatible with all configuration settings. When the device is
upgraded with a newer version or the same version builds, all the system’s configuration will be
preserved after the upgrade.
The new firmware image is uploaded to the controller’s temporary memory. It is necessary to save the
firmware into the device permanent memory. Click the Upgrade button:
Figure 49 – Firmware Upgrade
Upgrade – upgrade device with the uploaded image and reboot the system.
Do not switch off and do not disconnect the device from the power supply during the
firmware update process as the device could be damaged.
LigoWave
Page 41
Tools
Use the Tools menu to use the following device applications:



Site survey – to view the list of wireless networks in the surrounding area.
Antenna alignment – to align device antenna.
Link test – to check quality of the established PTP link.
Antenna Alignment
The antenna alignment test measures signal quality between the Master and Slave units. For best
results during the antenna alignment test, turn off all wireless networking devices within range of the
device except the device(s) with which you are trying to align the antenna. Watch the constantly
updated display in the antenna alignment test window as you adjust the antenna.
The Antenna Alignment test results appear when you click the Start button and finishes when you
click the Stop button.
Figure 50 – Antenna Alignment Tool
Average – if this option selected, the graph will display the average RSSI of both antennas.
Site Survey
The Site Survey test shows overview information for wireless networks in a local geographic area.
Using this test, an administrator can scan for working access points, check their operating frequency,
encryption, see signal/noise levels and view whether device has enabled W-Jet or not. This feature
may be used by the administrator find unused wireless channel so that PTP unit would not
interference with adjacent working devices thus getting best possible performance.
Note that Site Survey function can take several minutes to perform.
To perform the Site Survey test, click the Start scan button:
LigoWave
Page 42
Figure 51 – Site Survey Tool
Start scan – click to perform the Site Survey test.
Show only W-Jet AP – select this option to sort Site Survey results.
Link Test
We recommend to ensure that there is no traffic on the link before running the Link Test as
results may not be completely accurate.
Use the Link test tool to check the quality of the established PTP link. This tool tests the throughput at
selected packet sizes and iterations. Link test can be run from either the Remote unit or Local unit.
Results represent the maximum, minimum and average value of the performed test.
LigoWave
Page 43
Figure 52 – Link Test Tool
Iterations – specify number of test iterations.
Packet sizes – specify packet sizes in bytes at which the test will be performed.
Start – click to start the throughput test.
Stop – click to stop the throughput test.
LigoWave
Page 44
Logout
Click the Logout link on the top right corner of the main menu to leave the Web management
interface:
Figure 53 – Logout Page
Logout – click to leave the PTP unit Web management.
When the Logout button is clicked, the administrator is redirected to the login page of the PTP unit.
LigoWave
Page 45
Appendix
A) Run PTP Link in Small Distance
Follow up the steps to run the PTP link for testing it in small distances (e.g. testing on a table) and
achieve throughput up to 70 Mbps.
Step 1.
Power-up both units: Master and Slave.
Step 2.
PTP units must be placed at least a distance of 2 meters from each other.
Step 3.
Change major Radio parameters for both units (Master and Slave):
Figure 54 – Radio Settings



LigoWave
Channel width: 40 MHz
Transmit power: 5 dBm
Multipath protection: off
Page 46



Mode: MIMO 2x2
Data rate: 300 Mbps
ACK timeout: Distance 0 km/miles
Click Apply button for configuration to take effect.
Step 4.
Observe the Signal Indicator bar at the bottom of the screen. If it is green the quality of
the link is excellent whereas the red color indicates a poor quality of the link. If results
do not meet the requirements increase or decrease the Transmit Power on Radio page
depending on the status of the Signal Indicator bar. The Signal must be approximately
25-30dBm.
Step 5.
Start the testing: start the iperf server , then iperf client:
Figure 55 – iperf Results (TCP)
LigoWave
Page 47
Figure 56 – iperf Results (UDP)
Step 6.
If the result meets the requirements, before mounting PTP units outside, increase the
Transmit Power.
LigoWave
Page 48
B) Resetting Unit to Factory Defaults
PTP units have the capability of being reset to defaults by pinging the device with a certain packet
size when the radio is booting. During the startup of the device, when the drivers of the ethernet
interfaces are loaded, the discovery daemon is started. The daemon suspends startup process for 3
seconds and waits for ICMP "echo request" packet of length 369 bytes. If the packet received, the
discoveryd resets the device to default configuration.
It is recommended to connect PC to the device via switch, as depending on PC OS
settings, the ARP table might be flushed during wired link status change (connecting the
device that will be reset).
Steps to reset to default settings:
Step 1.
Power off the device.
Step 2.
Obtain the device MAC address.
Step 3.
Connect a PC to the same physical subnet as the device.
Step 4.
Execute 'arp -s' command to assign the IP address (IP address should be from the
same subnet as PC) to the device MAC address:
arp -s  
Note that syntax of MAC address differs depending on OS:


Step 5.
Linux OS: AA:BB:CC:DD:EE:FF
Windows OS: AA-BB-CC-DD-EE-FF
Start pinging the device:
For Linux users: ping  -s 369
For Windows users: ping  -l 369 -t -w 0.2
Step 6.
Power up device and wait about 30sec or more (depending on device hardware).
Step 7.
Stop pinging the device, and let the device boot as usual. The device should start up
with factory default settings.
LigoWave
Page 49

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : a
Create Date                     : 2013:02:01 09:22:18+08:00
Modify Date                     : 2013:02:01 09:22:18+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Format                          : application/pdf
Title                           : Microsoft Word - 1-LigoPTP software manual-待完善排版.docx
Creator                         : a
Document ID                     : uuid:59c33861-7877-47dc-a6b5-4f748d0ce6fe
Instance ID                     : uuid:eebf881d-91fe-4d24-be90-e73da0bb7daa
Page Count                      : 49
EXIF Metadata provided by EXIF.tools
FCC ID Filing: V2V-FWBD1401

Navigation menu