Linear 232Xt Owners Manual 232XTrev1_01
2014-07-19
: Linear Linear-232Xt-Owners-Manual linear-232xt-owners-manual linear pdf
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
232xt Wiring Diagrams and Specifications Voltage Selection Settings Wire Xtreme Pad color to color to the wires on Programmer P5* Position Position 1 12-24VAC 12-15VDC (Red to Red, ect.) 1 2 3 4 5 6 15-24VDC ( White / Yellow ) ( White / Black ) ( Black ) 7 8 9 * 0 # P2 P3 P4 P1 P5* RELAY SW1 V+ V *P5 is the Voltage Selector. With the jumper in position one, 12-15vdc only operation is selected. With the jumper in position two 15-24vdc/12-24vac operation is selected. Packing Checklist: Xtreme™ Keypad 232 XT Programming Controller Four Conductor Wire Harness (2) Three Conductor Wire Harness (4) Slotted Screws (4) Plastic Anchors (4) 5/64 Allen Head Wrench (1) Machine Screws (2) Tech Supp. With Warranty card ACCESS CONTROL Features and Programming Guide NC C P1 -REX INPUT/DOOR POSITION INPUT P2 -ALARM SHUNT RELAY P3 -FORCED DOOR RELAY P4 -DOOR AJAR RELAY P5 -VOLTAGE SELECTOR SW1 -PROGRAMMING SWITCH NO SPECIFICATIONS: MECHANICAL: XT CASE DIMENSIONS: 2.75”w x 4.50”h x 1.50”d ENVIRONMENTAL: TEMPERATURE: -20°F TO 130°F (-28°C TO 54°C) PROGRAMMER CASE DIMENSIONS: 2.75”w x 4.50”h x 2.50”d ELECTRICAL: VOLTAGE: 12-24 Volts AC/DC (selected by P5 jumper) CURRENT: @12-24 Volts AC/DC- 20ma typical-150ma max with all relays energized INTERNATIONAL INTERNATIONAL ELECTRONICS, INC. 427 TURNPIKE STREET, CANTON, MA 02021 U.S.A. 800-343-9502, 617-821-5566 (FAX)617-821-4443 OUTPUTS: Main relay: 8 Amp, Form-C @ 24volts-10 AMP surge Relays 2, 3, & 4 are Form C relays-1 AMP MAXIMUM TM ELECTRONICS, INC Visit our website for Access Control & Glassbreak information, New Products, Specifications, Applications, Seminars, and Partners @ www.ieib.com 6063170 REV 1.01 WIRING THE XTREME™ The Xtreme™ keypad is a device which you choose to place either inside or outside the door. IEI manufactures several other devices to choose from; keypads, magnetic card readers, proximity card readers, and touch chip readers. Choosing the correct device for the application is important. IEI manufactures light traffic and heavy traffic devices. If you are not sure which device to utilize, please call us at 1-800-343-9502. Voltmeter Electrical Tape ê Electrical Tape BLACK RED BLACK/WHITE BLACK\YELLOW Insulator 48” * ì Drain Wire to V- on Hub è - Wire harness is shown in reverse for ease of meter discription ( Black on the bottom, Red ,ect..) Wiring the Xtreme™ keypad to the programming control unit requires a four conductor,stranded and shielded cable to be wired between two units. Maximum lengths are as follows: 22 AWG stranded : 250 feet 20 AWG stranded : 500 feet 18 AWG stranded : 1000 feet At the programming control unit, connect the four conductor cable to the four pin connector on the controller relay board, as shown in the diagram above. The drain wire at the programming controller must be attached to ground, also the foil shield should be cut back with the insulator and taped with electrical tape. Ground is the V- terminal on TS1 if the power supply is grounded. At the Xtreme™ keypad, the drain wire and foil shield is cut back with the insulator and taped with electrical tape. The four conductor harness connects into the four wire harness on the Xtreme™ keypad. Both wire harnesses are connected to each other color to color. TESTING THE Xtreme™ KEYPAD FOR GROUND POTENTIAL DIFFERENCES If the Xtreme™ keypad is mounted to the metal door frame of the building, a ground potential test should be run. This test is important because a potential difference between the power supply ground and the ground on the metal frame of a building can render the system inoperable. The Xtreme™ keypad should first be installed and the power supply grounded and turned off. Now set up a meter to read DC voltage. At programming controller separate the black wire of the four conductor cable from the wire running to the Xtreme™ keypad and attach the meter in series with the two wires per diagram above. If the meter shows more than one volt then the front end must either be insulated from the frame or the ground wire of the reader must be removed. Setup meter to read AC voltage and repeat test. On the Xtreme™ keypad you will find the grounding wire screwed to the case at one end and plugged into the circuit board on the other end. If you have any questions about this procedure please call IEI Technical Support, 1-800-343-9502. Propped Door Relay This output is utilized to inform personnel that the door is being held, or propped open, after a valid entry. To accomplish this, the Xtreme™ programming controller comes equipped with a relay and an internal timer circuit that is designated for this purpose. The form C relays are rated to handle one (1) amp of current at either 12 volts or 24 volts, type AC or DC, and can turn on or off one leg of power to a warning device. Warning device not included with IEI equipment. To incorporate this feature into your system, simply locate one of the five connectors, each one with three (3) wires, green, blue, and gray, located in the box with the Xtreme™ programming controller. With the controller powered down, unlatch the keypad from the plastic housing and slide the printed circuit board out of housing, exposing the connectors as shown in Diagram A. Wiring the Propped Door Relay Xtreme™ CONTROL RELAY BOARD 1. Connect the three conductor harness with the green, blue, and gray wire to the propped door relay jack as shown in diagram A. 2. Connect green wire to V+ on sounder. 3. Connect blue wire to V+ from power supply. 4. Connect V- from power supply to V- on sounder. 5. Gray wire is not used. DIAGRAM A Propped Door Relay Programming the Propped Door Relay To program how long the door can be propped open before the alarm is tripped, Program as follows: **No programming is done at the Xtreme™ keypad.** 1. Enter programming mode. Press 99 # (master code) * 2. Verify that the programmer is in programming mode. (Yellow light should be flashing slowly.) 3. Press 44 # (time) # 0 # **, time represents how long the door may be propped before the relay energizes. Time must be 10 to 900 seconds GRAY (NC) NOT USED V+ GREEN (NO) BLUE (C) V+ VTo Power Supply Propped door time must be programmed in intervals of 10 seconds, ie. 10, 30, 60,... up to 900 seconds. 4. Press * to exit program mode, yellow light should not be flashing. NOTE: This feature requires that you utilize the Normally closed door contact (input) per diagram B. DIAGRAM B. Normally closed door contact white wire with orange stripe white wire Forced Door Relay This output is utilized to inform personnel that the door had been opened without authorization. To accomplish this, the Xtreme™ programming controller comes equipped with a relay and an internal timer circuit that is designated for this purpose. The form C relays are rated to handle one (1) amp of current at either 12 volts or 24 volts, type AC or DC, and can turn on or off one leg of power to a warning device. Warning device not included with IEI equipment. To incorporate this feature into your system, simply locate one of the five connectors, each one with three (3) wires, green, blue, and gray, located in the box with the Xtreme™ programming controller. With the controller powered down, unlatch the keypad from the plastic housing and slide the printed circuit board out of housing, exposing the connectors as shown in Diagram A. Wiring the Forced Door Relay 1. Connect the three conductor harness with the green, blue, and gray wire to the forced door relay jack as shown in diagram A. 2. Connect green wire to V+ on siren. 3. Connect blue wire to V+ from power supply. 4. Connect V- from power supply to V- on sounder. 5. Gray wire is not used. Xtreme™ CONTROL RELAY BOARD DIAGRAM A. Forced Door Relay Programming the Forced Door Relay To program the time that the forced door output will stay energized, program as follows: **No programming is done at the Xtreme™ keypad.** 1. Enter programming mode. Press 99 # (master code) * GRAY (NC) NOT USED V+ GREEN (NO) V2. Verify programmer is in programming mode. Yellow light should be flashing slowly. 3. Press 45 # (time) # 0 # * *, time represents how long the relay stays energized, 10 to 900 seconds, in Ten second intervals, or you may press 00 for a latched output, requiring a valid code to reset output. Forced door time must be programmed in intervals of 10 seconds, ie. 10, 30, 60,... up to 900 seconds. 4. Press * to exit program mode, yellow light should not be flashing. NOTE: This feature requires that you utilize the normally closed door contact (input) per diagram B. V+ BLUE (C) To Power Supply Normally closed door contact white wire with orange stripe white wire DIAGRAM B. Alarm Shunt Relay Xtreme™ CONTROL RELAY BOARD The Alarm shunt relay may be necessary to use when a security system or other type of system has already been in existence. The Alarm shunt relay keeps the alarm from activating when the door is opened, by keeping either a closed or opened state on the existing alarm panels zone. The Alarm shunt relay operates when the set of normally closed door contacts has been opened after a valid code entry. No programming required. The time of operation follows the main relay time. To incorporate this feature into your system, simply locate one of the three connectors, each one with three (3) wires, green, blue, and gray, located in the box with the Xtreme™ programming contoller. With the controller powered down, unlatch the keypad from the plastic housing and slide the printed circuit board out of housing, exposing the connectors as shown in diagram A. Wiring the Alarm Shunt Relay 1. Connect the three conductor harness with the green, blue, and gray wire to the alarm shunt relay jack as shown in diagram A. 2. Connect green wire to “Common” side of door contact. 3. Connect blue wire to “Normally Open” side of door contact. 4. Make a parallel connection to the green and blue wires,(as shown in diagram A.), and run the leads to the alarm panel. NOTE: This feature requires that you utilize the normally closed door contact (input) per diagram B. Auto Re-Lock DIAGRAM A Alarm Shunt Relay gray (not used) green To alarm panel blue Pre existing alarm panel door contact To alarm panel DIAGRAM B. Auto Re-Lock solves the problem of people “tailgating” in behind those using valid access protocol, allowing the programmer the opportunidoor contact ty to set a long door open time. This feature over-rides the main relay timer, resetting the white wire with orange stripe door open time as soon as the controller sees the door open. In many situations, you will find white wire yourself programming a long door open time, this allows people carrying packages enough time to get from the Xtreme™ to the door and open it before the timer runs out. Other people may only require a few seconds to do the same task, without an auto re-lock, the door would be left unlocked long enough for people to tailgate in behind you. No programming is necessary. After a valid access or egress, the programming control monitors the door contact, sees the door switch open and drops the main relay immediately. Disengaging the lock, which you will notice always locking behind you, whether you take three seconds to get to the door or ten seconds. NOTE: This feature requires that you utilize the normally closed door contact (input) per diagram B. Basic Access Control with an Electromagnetic Lock Normally Open Switch NO Normally Closed Door Contacts Input Loop Common Door Position Input Timed Egress Input NC NO C NC NO C Switch -Jumper on 2&3 for 12-15 VDC only -Jumper on 1&2 for 15-24 VDC 12-24 VAC TS 1 SW1 * If no contact in being used it must be jumped closed. (White/orange + White wire) Normally Open Switch Normally Closed Door Contacts C White/Orange White Brown Programming NC Basic Access Control with an Electric Door Strike NO NC NO NC NO C C White/Orange White Brown Input Loop Common Door Position Input Timed Egress Input Switch -Jumper on 2&3 for 12-15 VDC only -Jumper on 1&2 for 15-24 VDC 12-24 VAC TS 1 Programming * If no contact in being used it must be jumped closed. (White/orange + White wire) NC C SW1 Electric door strike 12 or 24 volt AC/DC power supply 12 or 24 volt AC/DC power supply Note: If powering the keypad and the lock with the same power supply, Lock voltage must match power supply voltage Integrated Access Control with an Electromagnetic Lock Note: If powering the keypad and the lock with the same power supply, Lock voltage must match power supply voltage Magnetic Door Lock ( Fail Safe ) Integrated Access Control with an Electric Door Strike To alarm panel closed circuit loop Normally Open Switch Normally Closed NO NC NO C Input Loop Common Door Position Input Timed Egress Input White/Orange White Brown Programming * If no contact in being used it must be jumped closed. (White/orange + White wire) Switch NC NO NC C Normally Open Switch Normally Closed -Jumper on 2&3 for 12-15 VDC only -Jumper on 1&2 for 15-24 VDC 12-24 VAC Input Loop Common Door Position Input Timed Egress Input White/Orange White Brown Programming * If no contact in being used it must be jumped closed. (White/orange + White wire) Switch 12 or 24 volt AC/DC power supply Magnetic door lock ( fail safe ) NC NO NO C C 12 or 24 volt AC/DC power supply Note: If powering the keypad and the lock with the same power supply, Lock voltage must match power supply voltage To alarm panel closed circuit loop Note: If powering the keypad and the lock with the same power supply, Lock voltage must match power supply voltage NC NO NC C C -Jumper on 2&3 for 12-15 VDC only -Jumper on 1&2 for 15-24 VDC 12-24 VAC Electric door strike
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 0000:01:01 00:00:00Z Subject : Modify Date : 2003:05:14 11:37:30-03:00 Page Count : 6 Creation Date : 0-01-01T00:00:00Z Author : Unknown Producer : Acrobat PDFWriter 3.02 for Windows Keywords : Mod Date : 2003:05:14 11:37:30-03:00 Metadata Date : 2003:05:14 11:37:30-03:00 Title : 232XTrev1_01.PDF Creator : Unknown Description :EXIF Metadata provided by EXIF.tools