Linear 232Xt Owners Manual 232XTrev1_01

2014-07-19

: Linear Linear-232Xt-Owners-Manual linear-232xt-owners-manual linear pdf

Open the PDF directly: View PDF PDF.
Page Count: 6

DownloadLinear Linear-232Xt-Owners-Manual 232XTrev1_01
Open PDF In BrowserView PDF
232xt Wiring Diagrams and Specifications
Voltage Selection Settings

Wire Xtreme Pad
color to color to the
wires on Programmer

P5*
Position

Position
1

12-24VAC

12-15VDC

(Red to Red, ect.)

1

2

3

4

5

6

15-24VDC

( White / Yellow )
( White / Black )

( Black )

7

8

9

*

0

#

P2

P3

P4

P1

P5*
RELAY

SW1
V+ V

*P5 is the Voltage Selector. With the jumper in position one, 12-15vdc only operation is
selected. With the jumper in position two 15-24vdc/12-24vac operation is selected.

Packing Checklist:
Xtreme™ Keypad
232 XT Programming Controller
Four Conductor Wire Harness (2)
Three Conductor Wire Harness (4)
Slotted Screws (4)
Plastic Anchors (4)
5/64 Allen Head Wrench (1)
Machine Screws (2)
Tech Supp. With Warranty card
ACCESS CONTROL Features and Programming Guide

NC

C

P1 -REX INPUT/DOOR POSITION INPUT
P2 -ALARM SHUNT RELAY
P3 -FORCED DOOR RELAY
P4 -DOOR AJAR RELAY
P5 -VOLTAGE SELECTOR
SW1 -PROGRAMMING SWITCH

NO

SPECIFICATIONS:
MECHANICAL:
XT CASE DIMENSIONS:
2.75”w x 4.50”h x 1.50”d

ENVIRONMENTAL:
TEMPERATURE:
-20°F TO 130°F (-28°C TO 54°C)

PROGRAMMER CASE DIMENSIONS:
2.75”w x 4.50”h x 2.50”d
ELECTRICAL:
VOLTAGE:
12-24 Volts AC/DC (selected by P5 jumper)
CURRENT:
@12-24 Volts AC/DC- 20ma typical-150ma max with all
relays energized

INTERNATIONAL

INTERNATIONAL ELECTRONICS, INC.
427 TURNPIKE STREET, CANTON, MA 02021 U.S.A.
800-343-9502, 617-821-5566 (FAX)617-821-4443

OUTPUTS:
Main relay: 8 Amp, Form-C @ 24volts-10 AMP surge
Relays 2, 3, & 4 are Form C relays-1 AMP MAXIMUM

TM

ELECTRONICS, INC

Visit our website for Access Control & Glassbreak information,
New Products, Specifications, Applications, Seminars, and Partners
@ www.ieib.com

6063170 REV 1.01

WIRING THE XTREME™
The Xtreme™ keypad is a device which you choose to place either inside or outside the door.
IEI manufactures several other devices to choose from; keypads, magnetic card readers, proximity
card readers, and touch chip readers.
Choosing the correct device for the application is important. IEI manufactures light traffic and
heavy traffic devices. If you are not sure which device to utilize, please call us at 1-800-343-9502.
Voltmeter

Electrical
Tape
ê

Electrical
Tape

BLACK
RED
BLACK/WHITE
BLACK\YELLOW

Insulator
48”

*

ì

Drain Wire
to V- on
Hub

è

- Wire harness is shown in reverse for ease of meter discription
( Black on the bottom, Red ,ect..)

Wiring the Xtreme™ keypad to the programming control unit requires a four conductor,stranded
and shielded cable to be wired between two units. Maximum lengths are as follows:
22 AWG stranded : 250 feet
20 AWG stranded : 500 feet
18 AWG stranded : 1000 feet
At the programming control unit, connect the four conductor cable to the four pin connector on the
controller relay board, as shown in the diagram above. The drain wire at the programming controller
must be attached to ground, also the foil shield should be cut back with the insulator and taped with
electrical tape. Ground is the V- terminal on TS1 if the power supply is grounded. At the
Xtreme™ keypad, the drain wire and foil shield is cut back with the insulator and taped with electrical tape. The four conductor harness connects into the four wire harness on the Xtreme™ keypad.
Both wire harnesses are connected to each other color to color.

TESTING THE Xtreme™ KEYPAD FOR GROUND POTENTIAL DIFFERENCES
If the Xtreme™ keypad is mounted to the metal door frame of the building, a ground potential
test should be run. This test is important because a potential difference between the power supply
ground and the ground on the metal frame of a building can render the system inoperable. The
Xtreme™ keypad should first be installed and the power supply grounded and turned off. Now set
up a meter to read DC voltage. At programming controller separate the black wire of the four conductor cable from the wire running to the Xtreme™ keypad and attach the meter in series with the
two wires per diagram above. If the meter shows more than one volt then the front end must either
be insulated from the frame or the ground wire of the reader must be removed. Setup meter to read
AC voltage and repeat test. On the Xtreme™ keypad you will find the grounding wire screwed to
the case at one end and plugged into the circuit board on the other end. If you have any questions
about this procedure please call IEI Technical Support, 1-800-343-9502.

Propped Door Relay
This output is utilized to inform personnel that the door is being held, or propped open, after a
valid entry. To accomplish this, the Xtreme™ programming controller comes equipped with a relay
and an internal timer circuit that is designated for this purpose. The form C relays are rated to handle one (1) amp of current at either 12 volts or 24 volts, type AC or DC, and can turn on or off one
leg of power to a warning device. Warning device not included with IEI equipment.
To incorporate this feature into your system, simply locate one of the five connectors, each one
with three (3) wires, green, blue, and gray, located in the box with the Xtreme™ programming controller. With the controller powered down, unlatch the keypad from the plastic housing and slide the
printed circuit board out of housing, exposing the connectors as shown in Diagram A.

Wiring the Propped Door Relay

Xtreme™ CONTROL RELAY BOARD

1. Connect the three conductor harness with the green,
blue, and gray wire to the propped door relay jack as
shown in diagram A.
2. Connect green wire to V+ on sounder.
3. Connect blue wire to V+ from power supply.
4. Connect V- from power supply to V- on sounder.
5. Gray wire is not used.

DIAGRAM A

Propped
Door
Relay

Programming the Propped Door Relay
To program how long the door can be propped open
before the alarm is tripped, Program as follows:
**No programming is done at the Xtreme™ keypad.**
1. Enter programming mode. Press 99 # (master code) *
2. Verify that the programmer is in programming mode.
(Yellow light should be flashing slowly.)
3. Press 44 # (time) # 0 # **, time represents how
long the door may be propped before the relay
energizes. Time must be 10 to 900 seconds

GRAY (NC) NOT USED

V+

GREEN (NO)

BLUE (C)

V+
VTo
Power Supply

Propped door time must be programmed in intervals of 10 seconds, ie. 10, 30, 60,... up to 900
seconds.
4. Press * to exit program mode, yellow light
should not be flashing.
NOTE: This feature requires that you utilize the
Normally closed door contact (input) per diagram B.

DIAGRAM B.
Normally
closed
door contact

white wire
with orange
stripe

white wire

Forced Door Relay
This output is utilized to inform personnel that the door had been opened without authorization.
To accomplish this, the Xtreme™ programming controller comes equipped with a relay and an internal timer circuit that is designated for this purpose. The form C relays are rated to handle one (1)
amp of current at either 12 volts or 24 volts, type AC or DC, and can turn on or off one leg of power
to a warning device. Warning device not included with IEI equipment.
To incorporate this feature into your system, simply locate one of the five connectors, each one
with three (3) wires, green, blue, and gray, located in the box with the Xtreme™ programming controller. With the controller powered down, unlatch the keypad from the plastic housing and slide the
printed circuit board out of housing, exposing the connectors as shown in Diagram A.

Wiring the Forced Door Relay
1. Connect the three conductor harness with the green, blue,
and gray wire to the forced door relay jack as shown in diagram A.
2. Connect green wire to V+ on siren.
3. Connect blue wire to V+ from power supply.
4. Connect V- from power supply to V- on sounder.
5. Gray wire is not used.

Xtreme™ CONTROL RELAY BOARD
DIAGRAM A.

Forced
Door
Relay

Programming the Forced Door Relay
To program the time that the forced door output
will stay energized, program as follows:
**No programming is done at the Xtreme™ keypad.**
1. Enter programming mode. Press 99 # (master
code) *

GRAY (NC) NOT USED

V+

GREEN (NO)

V2. Verify programmer is in programming mode.
Yellow light should be flashing slowly.
3. Press 45 # (time) # 0 # * *, time represents how
long the relay stays energized, 10 to 900 seconds, in Ten second intervals, or you may
press 00 for a latched output,
requiring a valid code to reset output. Forced
door time must be programmed in intervals of
10 seconds, ie. 10, 30, 60,... up to 900 seconds.

4. Press * to exit program mode, yellow light
should not be flashing.
NOTE: This feature requires that you utilize the
normally closed door contact (input) per diagram B.

V+

BLUE (C)

To
Power Supply

Normally
closed
door contact
white wire
with orange
stripe

white wire

DIAGRAM B.

Alarm Shunt Relay

Xtreme™ CONTROL RELAY BOARD

The Alarm shunt relay may be necessary to use when a
security system or other type of system has already been in
existence. The Alarm shunt relay keeps the alarm from activating when the door is opened, by keeping either a closed or
opened state on the existing alarm panels zone. The Alarm
shunt relay operates when the set of normally closed door
contacts has been opened after a valid code entry. No programming required. The time of operation follows the main
relay time.
To incorporate this feature into your system, simply locate
one of the three connectors, each one with three (3) wires,
green, blue, and gray, located in the box with the Xtreme™
programming contoller. With the controller powered down,
unlatch the keypad from the plastic housing and slide the
printed circuit board out of housing, exposing the connectors
as shown in diagram A.

Wiring the Alarm Shunt Relay
1. Connect the three conductor harness with the green, blue,
and gray wire to the alarm shunt relay jack as shown in diagram A.
2. Connect green wire to “Common” side of door contact.
3. Connect blue wire to “Normally Open” side of door contact.
4. Make a parallel connection to the green and blue wires,(as
shown in diagram A.), and run the leads to the alarm panel.
NOTE: This feature requires that you utilize the normally
closed door contact (input) per diagram B.

Auto Re-Lock

DIAGRAM A

Alarm
Shunt
Relay

gray (not used)
green
To alarm panel
blue
Pre existing
alarm panel
door contact

To alarm panel

DIAGRAM B.

Auto Re-Lock solves the problem of people
“tailgating” in behind those using valid access
protocol, allowing the programmer the opportunidoor contact
ty to set a long door open time. This feature
over-rides the main relay timer, resetting the
white wire with
orange stripe
door open time as soon as the controller sees
the door open. In many situations, you will find
white wire
yourself programming a long door open time,
this allows people carrying packages enough
time to get from the Xtreme™ to the door and
open it before the timer runs out. Other people may only require a few seconds to do the same task,
without an auto re-lock, the door would be left unlocked long enough for people to tailgate in behind
you. No programming is necessary. After a valid access or egress, the programming control monitors the door contact, sees the door switch open and drops the main relay immediately. Disengaging
the lock, which you will notice always locking behind you, whether you take three seconds to get to
the door or ten seconds. NOTE: This feature requires that you utilize the normally closed door
contact (input) per diagram B.

Basic Access Control with an Electromagnetic Lock

Normally
Open Switch

NO

Normally Closed
Door Contacts

Input Loop Common
Door Position Input
Timed Egress Input

NC NO
C

NC NO
C

Switch

-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC

TS 1
SW1

* If no contact in being used it
must be jumped closed.
(White/orange + White wire)

Normally
Open Switch

Normally Closed
Door Contacts

C

White/Orange
White
Brown
Programming

NC

Basic Access Control with an Electric Door Strike

NO

NC NO

NC NO
C

C

White/Orange
White
Brown

Input Loop Common
Door Position Input
Timed Egress Input

Switch

-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC

TS 1

Programming
* If no contact in being used it
must be jumped closed.
(White/orange + White wire)

NC
C

SW1

Electric door strike

12 or 24 volt AC/DC
power supply

12 or 24 volt AC/DC
power supply
Note: If powering the keypad and the lock with the
same power supply, Lock
voltage must match power
supply voltage

Integrated Access
Control with an
Electromagnetic Lock

Note: If powering the keypad and
the lock with the same power supply, Lock voltage must match
power supply voltage

Magnetic Door Lock
( Fail Safe )

Integrated Access
Control with an
Electric Door
Strike

To alarm
panel closed
circuit loop

Normally
Open Switch

Normally Closed

NO

NC NO
C

Input Loop Common
Door Position Input
Timed Egress Input

White/Orange
White
Brown

Programming
* If no contact in being used it
must be jumped closed.
(White/orange + White wire)

Switch

NC NO NC
C

Normally
Open Switch

Normally Closed

-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC

Input Loop Common
Door Position Input
Timed Egress Input

White/Orange
White
Brown

Programming
* If no contact in being used it
must be jumped closed.
(White/orange + White wire)

Switch

12 or 24 volt AC/DC
power supply

Magnetic door lock ( fail safe )

NC NO

NO
C

C

12 or 24 volt AC/DC
power supply
Note: If powering the keypad
and the lock with the same
power supply, Lock voltage must
match power supply voltage

To alarm
panel closed
circuit loop

Note: If powering the keypad
and the lock with the same
power supply, Lock voltage must
match power supply voltage

NC NO NC
C

C

-Jumper on 2&3 for
12-15 VDC only
-Jumper on 1&2 for
15-24 VDC
12-24 VAC

Electric door strike



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Create Date                     : 0000:01:01 00:00:00Z
Subject                         : 
Modify Date                     : 2003:05:14 11:37:30-03:00
Page Count                      : 6
Creation Date                   : 0-01-01T00:00:00Z
Author                          : Unknown
Producer                        : Acrobat PDFWriter 3.02 for Windows
Keywords                        : 
Mod Date                        : 2003:05:14 11:37:30-03:00
Metadata Date                   : 2003:05:14 11:37:30-03:00
Title                           : 232XTrev1_01.PDF
Creator                         : Unknown
Description                     : 
EXIF Metadata provided by EXIF.tools

Navigation menu